Advertisement for orthosearch.org.uk
Results 101 - 120 of 244
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 741 - 746
1 Nov 1985
Hardcastle P Nade S

Trendelenburg's test of function of the hip joint was first reported before radiology was available. At least four methods of performing it have since been described in the literature. We examined 50 normal subjects and 103 people with disorders affecting either the spine or the hip, in order to determine the different responses that occurred when they were asked to stand on one leg. This has enabled us to define a standard method of performing the Trendelenburg test, and to interpret the test as a method of assessing hip abductor function. The major pitfalls that result in misinterpretation, or false-positive responses, are pain, lack of cooperation from the patient, and impingement between the rib cage and the iliac crest. False-negative responses result from the patient using muscles above and below the pelvis, and from leaning beyond the hip on the standing side


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 4 | Pages 658 - 667
1 Nov 1967
Guirguis AR

1. A comparison of the results of sixty patients with Pott's paraplegia, half operated upon and half treated conservatively, showed that better results were achieved in a much shorter time in those treated surgically. 2. Extra-pleural antero-lateral decompression is the operation of choice in cases of Pott's paraplegia. 3. The operation should be done as soon as the general condition of the patient allows, and should not be left until the disease is quiescent. 4. The greatest improvement is found in those patients who are still ambulant. 5. Although the gain in patients with complete paraplegia may be small, relief from painful flexor spasms and the healing of bed-sores often justify surgical treatment. 6. Fusion of the vertebral bodies can be carried out at the same sitting using healthy ribs and sometimes cancellous bone, with satisfactory results


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 84 - 88
1 Jan 1990
Karray S Zlitni M Fowles J Zouari O Slimane N Kassab M Rosset P

We report the management of two children and 11 adults with paraplegia secondary to vertebral hydatidosis. Destruction of pedicles, posterior vertebral elements and discs as well as the vertebral bodies was common and all six patients with thoracic disease had involvement of adjacent ribs. The 13 patients had a total of 42 major surgical procedures; two patients died from postoperative complications and four from complications of the disease and paraplegia. All eight patients initially treated by laminectomy or anterior decompression alone relapsed within two years and seven required further surgery. Circumferential decompression and grafting gave the best results, six of nine patients being in remission an average of three years and six months later. The prognosis for such patients is poor; remission is the aim, rather than cure. Anthelminthic drugs may improve the prognosis, but radical surgery is likely to remain the keystone of treatment in the foreseeable future


Bone & Joint 360
Vol. 9, Issue 6 | Pages 41 - 43
1 Dec 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 167 - 174
1 May 1975
Trevor D Johns DL Fixsen JA

The results in 102 acetabuloplasties have been assessed in eighty-six patients, with a minimum follow-up of five years. Clinical and radiological assessment was carried out according to a score system very similar to that used in previous studies, and the results were expressed as excellent, good, fair and poor according to the score obtained. Any hip requiring further stabifising procedures was automatically grouped as a failure. Subtrochanteric femoral osteotomy was used when femoral anteversion was excessive. The results revealed that 73 per cent of the hips were satisfactory (excellent or good) overall, but that a steady deterioration was evident when the five-and fifteen-year groups were compared. Few of the hips were regarded as normal on radiological grounds. Homologous bone bank rib was found to be the most satisfactory graft material. Coxa magna was the most common abnormality that was consistent with a good or excellent result. Avascular necrosis of the femoral head was found in only six hips; it was more commonly present in patients subjected to previous operation. Concentric reduction of the femoral head is essential if acetabuloplasty is to maintain stability of the hip


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 148 - 156
1 Jan 2021
Tsirikos AI Carter TH

Aims

To report the surgical outcome of patients with severe Scheuermann’s kyphosis treated using a consistent technique and perioperative management.

Methods

We reviewed 88 consecutive patients with a severe Scheuermann's kyphosis who had undergone posterior spinal fusion with closing wedge osteotomies and hybrid instrumentation. There were 55 males and 33 females with a mean age of 15.9 years (12.0 to 24.7) at the time of surgery. We recorded their demographics, spinopelvic parameters, surgical correction, and perioperative data, and assessed the impact of surgical complications on outcome using the Scoliosis Research Society (SRS)-22 questionnaire.


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 4 | Pages 644 - 651
1 Nov 1958
Axer A

1 . An operation for strengthening the lateral abdominal muscles in children after poliomyelitis is described. It consists of transposition of the proximal part of the gluteus maximus, the tensor fasciae latae and the ilio-tibial band ("the pelvic deltoid" of Henry) to a chosen rib. 2. The results of this operation in eight consecutive cases of paralytic scoliosis, pelvic obliquity and thoraco-pelvic instability are assessed. 3. A "strong" motor allows the child to lift the pelvis against gravity, whereas with a "weak" motor the child is unable to do so efficiently. However, even a "weak" musculotendinous tendinous unit helps invariably in restoring the thoraco-pelvic stability, just as a weak "hamstring-into-patella" transplant stabilises the knee. 4. Those motors (gluteus maximus with or without tensor fasciae latae) that contract vigorously and move the free end of the ilio-tibial band for at least three centimetres on direct faradic stimulation with a bipolar electrode during the operation become ultimately strong and most efficient. 5. The unreliability of the clinical test of tensor fasciae latae in small children is discussed, and the advantage of using the gluteus maximus as the motor for the musculo-tendinous unit is emphasised. 6. Using the proximal half (or less) of the gluteus maximus for strengthening the lateral abdominal muscles does not seem to affect appreciably the strength of hip extension. This phenomenon may be explained with reasonable probability by the existence of a twofold insertion of that muscle


Bone & Joint 360
Vol. 9, Issue 5 | Pages 44 - 46
1 Oct 2020


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1313 - 1320
1 Oct 2019
Tsuda Y Gregory JJ Fujiwara T Abudu S

Aims

The aim of this study was to report the outcomes of patients who underwent definitive surgery for secondary chondrosarcomas arising from osteochondromas.

Patients and Methods

A total of 51 patients with secondary chondrosarcomas occurring from osteochondromas were reviewed. Median age was 36 years (interquartile range (IQR) 15 to 82). Median follow-up was 6.9 years (IQR 2.8 to 10.6). The pelvis was the most commonly affected site (59%). Histological grades were grade I in 35 (69%), grade II in 13 (25%), and grade III in three patients (6%).


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1560 - 1566
2 Nov 2020
Mehdian H Haddad S Pasku D Nasto LA

Aims

To report the mid-term results of a modified self-growing rod (SGR) technique for the treatment of idiopathic and neuromuscular early-onset scoliosis (EOS).

Methods

We carried out a retrospective analysis of 16 consecutive patients with EOS treated with an SGR construct at a single hospital between September 2008 and December 2014. General demographics and deformity variables (i.e. major Cobb angle, T1 to T12 length, T1 to S1 length, pelvic obliquity, shoulder obliquity, and C7 plumb line) were recorded preoperatively, and postoperatively at yearly follow-up. Complications and revision procedures were also recorded. Only patients with a minimum follow-up of five years after surgery were included.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 20 - 21
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 13 - 18
1 Jan 1998
Ransford AO Morley T Edgar MA Webb P Passuti N Chopin D Morin C Michel F Garin C Pries D

We have evaluated the use of a synthetic porous ceramic (Triosite) as a substitute for bone graft in posterior spinal fusion for idiopathic scoliosis. In a prospective, randomised study 341 patients at five hospitals in the UK and France were randomly allocated either to autograft from the iliac crest or rib segments (171) or to receive Triosite blocks (170). All patients were assessed after operation and at 3, 6, 12 and 18 months. The two groups were similar with regard to all demographic and baseline variables, but the 184 treated in France (54%) had Cotrel-Dubouset instrumentation and the 157 treated in the UK usually had Harrington-Luque implants. In the Triosite group the average Cobb angle of the upper curve was 56°, corrected to 24° (57%). At 18 months, the average was 26° (3% loss). In the autograft group the average preoperative upper curve of 53° was corrected to 21° (60%). At 18 months the mean curve was 25° (8% loss). Pain levels after operation were similar in the two groups, being mild in most cases. In the Triosite group only three patients had problems of wound healing, but in the autograft group, 14 patients had delayed healing, infection or haematoma in the spinal wound. In addition, 15 autograft patients had pain at the donor site at three months. Seven had infections, two had haematoma and four had delayed healing. The haematological and serum biochemistry results showed no abnormal trends and no significant differences between the groups. There were no adverse events related to the graft material and no evidence of allergenicity. Our results suggest that Triosite synthetic porous ceramic is a safe and effective substitute for autograft in these patients. Histological findings on biopsy indicate that Triosite provides a favourable scaffolding for the formation of new bone and is gradually incorporated into the fusion mass


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 452 - 463
1 Aug 1983
Burwell R James N Johnson F Webb J Wilson Y

This paper reports a new method for expressing numerically asymmetry of the contour of the back in a forward-bending position. Information is given at three spinal levels (T8, T12 and L3) for 636 schoolchildren aged 8 to 15 years. Rib-hump and lumbar-hump scores were standardised to create trunk asymmetry scores (TASs) making comparison possible between children of different age, size and sex. Two groups of children were defined: those with clinically straight spines (585 children); and those with clinical evidence of lateral spinal curves (51 children). In the children with clinically straight spines the main findings were: about 1:4 had objectively detectable rib and lumbar humps; female-to-male ratios were 1.2:1 for the thoracic region and 1.4:1 for the lumbar region; right humps were about 10 times more common than left; TASs in the boys and girls at each spinal level had normal distributions about means to the right of zero (where zero represents perfect symmetry); at T8 and T12, a wider scatter of TASs in girls than in boys; at L3, larger TASs in girls than in boys; a relation between shortening of one lower limb and a contralateral hump on the back; and no relation to age (except at L3), stature (corrected for age) or handedness. The findings are discussed in relation to possible causes of back contour asymmetry, early diagnosis of scoliosis by screening, sexual dimorphism and significance for the pathogenesis of idiopathic scoliosis. Ten children with clinically straight spines and larger TASs, and 42 out of 51 children with clinical evidence of lateral spinal curves in the forward-bending position attended for radiographic examination. Twelve children had "scoliosis curves" of 11 degrees or more as defined by the Scoliosis Research Society. The results are reported in relation to TASs, spinal curve angle (Cobb) and vertebral rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 4 | Pages 718 - 725
1 Nov 1957
Bartelink DL

1. Since the publication by Bradford and Spurling in 1945 of The Intervertebral Disc, there has been argument about the figure of 1,600 pounds that they calculated as the load on each lower lumbar intervertebral disc when a person lifts a heavy load with the trunk flexed, especially since experiments have shown that intervertebral discs subjected to increasing pressures yield at values well below this figure. In the author's experiments the discs were destroyed by pressures ranging from 350 to 1,400 pounds, with a mean of 710 pounds. 2. It occurred to the writer that the spine is not necessarily the only structure in the body that can transmit pressure forces from the shoulder to the pelvis. A raised intra-abdominal pressure impacts a thrust under the diaphragm, which will be transmitted to the thoracic spine and the shoulders by means of the ribs. This thrust can take care of part of the lifted weight and thus decrease the load on the spine. 3. In experiments in which the intra-abdominal pressure was measured by means of a small balloon in the stomach it was found that the pressure rose proportionally with the amount of weight lifted. 4. It is suggested that the abdominal fluid ball can exert a longitudinal force only if there is no contraction of the longitudinal muscles (at least anteriorly). Electromyographic studies of the abdominal muscles during weight lifting showed that the transverse and possibly the oblique abdominal muscles contract, but not the recti. 5. It thus seems that the load on the intervertebral discs is not necessarily so great as Bradford and Spurling calculated, but can remain within safe limits. It is hard to give accurate figures for the amount of load that is taken off the spine in this way, but an estimate would put it at several hundred pounds. The importance of a reflex contraction of the abdominal wall during effort as a protective mechanism for the spine must therefore be appreciated. Voluntary contraction may also be called upon to increase the intra-abdominal pressure and so reduce the load on the discs. This is done by many weight lifters


Bone & Joint 360
Vol. 9, Issue 3 | Pages 5 - 7
1 Jun 2020
Lebel DE Rocos B


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 918 - 923
1 Sep 1998
Bruns J Kahrs J Kampen J Behrens P Plitz W

Our aim was to examine the potential of autologous perichondral tissue to form a meniscal replacement. In 18 mature sheep we performed a complete medial meniscectomy. The animals were then divided into two groups: 12 had a meniscal replacement using strips of autologous perichondral tissue explanted from the lower rib (group G) and six (group C) served as a control group without a meniscal replacement. In all animals restriction from weight-bearing was achieved by means of transection and partial resection of tendo Achillis. Six animals (four from group G and two from group C) were each killed at 3, 6 and 12 months. The grafts and the underlying articular cartilage were removed and studied by gross macroscopic examination, light microscopy, SEM, polarised light examination, and by biomechanical tests. In all the transplanted animals a new perichondral meniscus developed. After three months the transplants resembled normal menisci in size and thickness, while in the control animals only small rims of spontaneously grown tissue were seen. Microscopically, the perichondral menisci showed a normal orientation of collagen fibres and normal cellular characteristics, but in the central region, areas of calcification disturbed the regular tissue differentiation. Healing tissue in control animals lacked the normal fibre orientation and cellularity. SEM of perichondral menisci showed surface characteristics similar to those of normal sheep menisci without fissures and lacerations; the control specimens had these defects. The femoral and tibial cartilage in contact with the new menisci had normal surface characteristics apart from one animal with slight surface irregularities. Control animals showed superficial lesions after three months which increased at six to 12 months postoperatively. Microangiography of the newly grown tissue demonstrated a less intense vascularisation after three months when compared with normal menisci. The failure stress and tensile modulus of perichondral menisci were significantly lower than those of normal contralateral menisci, and spontaneously regenerated tissue in meniscectomised animals had even lower values. There were no significant differences in values between newly grown perichondral menisci and spontaneously grown tissue


Bone & Joint Open
Vol. 1, Issue 7 | Pages 405 - 414
15 Jul 2020
Abdelaal A Munigangaiah S Trivedi J Davidson N

Aims

Magnetically controlled growing rods (MCGR) have been gaining popularity in the management of early-onset scoliosis (EOS) over the past decade. We present our experience with the first 44 MCGR consecutive cases treated at our institution.

Methods

This is a retrospective review of consecutive cases of MCGR performed in our institution between 2012 and 2018. This cohort consisted of 44 children (25 females and 19 males), with a mean age of 7.9 years (3.7 to 13.6). There were 41 primary cases and three revisions from other rod systems. The majority (38 children) had dual rods. The group represents a mixed aetiology including idiopathic (20), neuromuscular (13), syndromic (9), and congenital (2). The mean follow-up was 4.1 years, with a minimum of two years. Nine children graduated to definitive fusion. We evaluated radiological parameters of deformity correction (Cobb angle), and spinal growth (T1-T12 and T1-S1 heights), as well as complications during the course of treatment.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 37 - 39
1 Apr 2020


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims

We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed.

Methods

All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.


Bone & Joint Research
Vol. 9, Issue 5 | Pages 211 - 218
1 May 2020
Hashimoto A Miyamoto H Kobatake T Nakashima T Shobuike T Ueno M Murakami T Noda I Sonohata M Mawatari M

Aims

Biofilm formation is intrinsic to prosthetic joint infection (PJI). In the current study, we evaluated the effects of silver-containing hydroxyapatite (Ag-HA) coating and vancomycin (VCM) on methicillin-resistant Staphylococcus aureus (MRSA) biofilm formation.

Methods

Pure titanium discs (Ti discs), Ti discs coated with HA (HA discs), and 3% Ag-HA discs developed using a thermal spraying were inoculated with MRSA suspensions containing a mean in vitro 4.3 (SD 0.8) x 106 or 43.0 (SD 8.4) x 105 colony-forming units (CFUs). Immediately after MRSA inoculation, sterile phosphate-buffered saline or VCM (20 µg/ml) was added, and the discs were incubated for 24 hours at 37°C. Viable cell counting, 3D confocal laser scanning microscopy with Airyscan, and scanning electron microscopy were then performed. HA discs and Ag HA discs were implanted subcutaneously in vivo in the dorsum of rats, and MRSA suspensions containing a mean in vivo 7.2 (SD 0.4) x 106  or 72.0 (SD 4.2) x 105  CFUs were inoculated on the discs. VCM was injected subcutaneously daily every 12 hours followed by viable cell counting.