Advertisement for orthosearch.org.uk
Results 101 - 120 of 120
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 188 - 193
1 Feb 2011
Rudol G Wilcox R Jin Z Tsiridis E

The mechanical performance of the cement-in-cement interface in revision surgery has not been fully investigated. The quantitative effect posed by interstitial fluids and roughening of the primary mantle remains unclear. We have analysed the strength of the bilaminar cement-bone interface after exposure of the surface of the primary mantle to roughening and fluid interference. The end surfaces of cylindrical blocks of cement were machined smooth (Ra = 200 nm) or rough (Ra = 5 μm) and exposed to either different volumes of water and carboxymethylcellulose (a bone-marrow equivalent) or left dry. Secondary blocks were cast against the modelled surface. Monoblocks of cement were used as a control group. The porosity of the samples was investigated using micro-CT. Samples were exposed to a single shearing force to failure. The mean failure load of the monoblock control was 5.63 kN (95% confidence interval (CI) 5.17 to 6.08) with an estimated shear strength of 36 MPa. When small volumes of any fluid or large volumes were used, the respective values fell between 4.66 kN and 4.84 kN with no significant difference irrespective of roughening (p > 0.05). Large volumes of carboxymethylcellulose significantly weakened the interface. Roughening in this group significantly increased the strength with failure loads of 2.80 kN (95% CI 2.37 to 3.21) compared with 0.86 kN (95% CI 0.43 to 1.27) in the smooth variant. Roughening of the primary mantle may not therefore be as crucial as has been previously thought in clinically relevant circumstances


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 285 - 292
1 Mar 2011
Cash DJW Jones JWM

This paper describes the presence of tenodesis effects in normal physiology and explores the uses of operative tenodesis in surgery of the upper limb.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 131 - 139
1 Jan 2011
Daugaard H Elmengaard B Andreassen TT Baas J Bechtold JE Soballe K

Impaction allograft is an established method of securing initial stability of an implant in arthroplasty. Subsequent bone integration can be prolonged, and the volume of allograft may not be maintained. Intermittent administration of parathyroid hormone has an anabolic effect on bone and may therefore improve integration of an implant.

Using a canine implant model we tested the hypothesis that administration of parathyroid hormone may improve osseointegration of implants surrounded by bone graft. In 20 dogs a cylindrical porous-coated titanium alloy implant was inserted into normal cancellous bone in the proximal humerus and surrounded by a circumferential gap of 2.5 mm. Morsellised allograft was impacted around the implant. Half of the animals were given daily injections of human parathyroid hormone (1–34) 5 μg/kg for four weeks and half received control injections. The two groups were compared by mechanical testing and histomorphometry. We observed a significant increase in new bone formation within the bone graft in the parathyroid hormone group. There were no significant differences in the volume of allograft, bone-implant contact or in the mechanical parameters.

These findings suggest that parathyroid hormone improves new bone formation in impacted morsellised allograft around an implant and retains the graft volume without significant resorption. Fixation of the implant was neither improved nor compromised at the final follow-up of four weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 315 - 319
1 Feb 2010
Lalliss SJ Branstetter JG

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7).

There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N.

FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1303 - 1305
1 Sep 2005
Kragh JF Svoboda SJ Wenke JC Ward JA Walters TJ

Our aim was to compare the biomechanical properties of suturing methods to determine a better method for the repair of lacerated skeletal muscle.

We tested Kessler stitches and the combination of Mason-Allen and perimeter stitches. Individual stitches were placed in the muscle belly of quadriceps femoris from a pig cadaver and were tensioned mechanically. The maximum loads and strains were measured and failure modes recorded. The mean load and strain for the Kessler stitches were significantly less than those for combination stitches. All five Kessler stitches tore out longitudinally from the muscle. All five combination stitches did not fail but successfully elongated.

Our study has shown that the better method of repair for suturing muscle is the use of combination stitches.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 103 - 109
1 Jan 2010
Laffosse J Espié A Bonnevialle N Mansat P Tricoire J Bonnevialle P Chiron P Puget J

We retrospectively analysed the clinical results of 30 patients with injuries of the sternoclavicular joint at a minimum of 12 months’ follow-up. A closed reduction was attempted in 14 cases. It was successful in only five of ten dislocations, and failed in all four epiphyseal disruptions. A total of 25 patients underwent surgical reduction, in 18 cases in conjunction with a stabilisation procedure.

At a mean follow-up of 60 months, four patients were lost to follow-up. The functional results in the remainder were satisfactory, and 18 patients were able to resume their usual sports activity at the same level. There was no statistically significant difference between epiphyseal disruption and sternoclavicular dislocation (p > 0.05), but the functional scores (Simple Shoulder Test, Disability of Arm, Shoulder, Hand, and Constant scores) were better when an associated stabilisation procedure had been performed rather than reduction alone (p = 0.05, p = 0.04 and p = 0.07, respectively).

We recommend meticulous pre-operative clinical assessment with CT scans. In sternoclavicular dislocation managed within the first 48 hours and with no sign of mediastinal complication, a closed reduction can be attempted, although this was unsuccessful in half of our cases. A control CT scan is mandatory. In all other cases, and particularly if epiphyseal disruption is suspected, we recommend open reduction with a stabilisation procedure by costaclavicular cerclage or tenodesis. The use of a Kirschner wire should be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 201 - 205
1 Feb 2009
Hanusch BC Goodchild L Finn P Rangan A

The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique.

The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire.

The mean Constant score improved significantly from 36 before to 68 after operation (p < 0.0001) and the mean Oxford Shoulder score from 39 to 20 (p < 0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 8 - 15
1 Jan 2009
Bardakos NV Villar RN

Advances in hip arthroscopy have renewed interest in the ligamentum teres. Considered by many to be a developmental vestige, it is now recognised as a significant potential source of pain and mechanical symptoms arising from the hip joint. Despite improvements in imaging, arthroscopy remains the optimum method of diagnosing lesions of the ligamentum teres. Several biological or mechanical roles have been proposed for the ligament. Unless these are disproved, the use of surgical procedures that sacrifice the ligamentum teres, as in surgical dislocation of the hip, should be carefully considered. This paper provides an update on the development, structure and function of the ligamentum teres, and discusses associated clinical implications.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis.

Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity.

Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01).

Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1165 - 1171
1 Sep 2007
Gohil S Annear PO Breidahl W

Animal studies have shown that implanted anterior cruciate ligament (ACL) grafts initially undergo a process of revascularisation prior to remodelling, ultimately increasing mechanical strength. We investigated whether minimal debridement of the intercondylar notch and the residual stump of the ruptured ACL leads to earlier revascularisation in ACL reconstruction in humans. We undertook a randomised controlled clinical trial in which 49 patients underwent ACL reconstruction using autologous four-strand hamstring tendon grafts. Randomised by the use of sealed envelopes, 25 patients had a conventional clearance of the intercondylar notch and 24 had a minimal debridement method. Three patients were excluded from the study. All patients underwent MR scanning postoperatively at 2, 6 and 12 months, together with clinical assessment using a KT-1000 arthrometer and International Knee Documentation Committee (IKDC) evaluation. All observations were made by investigators blinded to the surgical technique. Signal intensity was measured in 4 mm diameter regions of interest along the ACL graft and the mid-substance of the posterior cruciate ligament.

Our results indicate that minimal debridement leads to earlier revascularisation within the mid-substance of the ACL graft at two months (paired t-test, p = 0.002). There was a significant reduction of mid-substance signal six months after the minimal debridement technique (paired t-test, p = 0.00007). No statistically significant differences were found in tunnel placement, incidence of Cyclops lesions, blood loss, IKDC scores, range of movement or Lachman test between the two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 697 - 707
1 Jun 2008
Fraser-Moodie JA Shortt NL Robinson CM

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1539 - 1544
1 Nov 2006
Abu-Rajab RB Stansfield BW Nunn T Nicol AC Kelly IG

This study evaluated the effect on movement under load of three different techniques for re-attachment of the tuberosities of the humerus using test sawbones. In the first, the tuberosities were attached both to the shaft and to each other, with one cerclage suture through the anterior hole in the prosthesis. The second technique was identical except for omission of the cerclage suture and in the third the tuberosities were attached to the prosthesis and to the shaft. An orthogonal photogrammetric system allowed all segments to be tracked in a 3D axis system. The humeri were incrementally-loaded in abduction, and the 3D linear and angular movements of all segments were calculated. Displacement between the tuberosities and the shaft was measured.

The first and second techniques were the most stable constructs, with the third allowing greater separation of fragments and angular movement. Separation at the midpoint of the tuberosities was significantly greater using the latter technique (p < 0.05). The cerclage suture added no further stability to the fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 988 - 992
1 Aug 2006
Robertson A Nutton RW Keating JF


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 503 - 509
1 Apr 2007
Giannoudis PV Tzioupis C Moed BR

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulum were treated operatively using this technique.

The quality of reduction measured from three standard plain radiographs was graded as anatomical in all 29 hips. The clinical outcome at a mean follow-up of 35 months (24 to 90) was considered to be excellent in five patients (17%), very good in 16 (55%), good in six (21%) and poor in two (7%). The use of the two-level reconstruction technique appears to provide stable fixation and is associated with favourable results in terms of the incidence of post-traumatic osteoarthritis and the clinical outcome. However, poor results may occur in patients over the age of 55 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 267 - 271
1 Feb 2005
van Haaren EH Smit TH Phipps K Wuisman PIJM Blunn G Heyligers IC

Impacted morsellised allografts have been used successfully to address the problem of poor bone stock in revision surgery. However, there are concerns about the transmission of pathogens, the high cost and the shortage of supply of donor bone. Bone-graft extenders, such as tricalcium phosphate (TCP) and hydroxyapatite (HA), have been developed to minimise the use of donor bone. In a human cadaver model we have evaluated the surgical and mechanical feasibility of a TCP/HA bone-graft extender during impaction grafting revision surgery.

A TCP/HA allograft mix increased the risk of producing a fissure in the femur during the impaction procedure, but provided a higher initial mechanical stability when compared with bone graft alone. The implications of the use of this type of graft extender in impaction grafting revision surgery are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 841 - 851
1 Jul 2006
Lee EH Hui JHP


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 870 - 876
1 Jul 2009
Kosashvili Y Backstein D Safir O Lakstein D Gross AE

Pelvic discontinuity with associated bone loss is a complex challenge in acetabular revision surgery. Reconstruction using ilio-ischial cages combined with trabecular metal acetabular components and morsellised bone (the component-cage technique) is a relatively new method of treatment.

We reviewed a consecutive series of 26 cases of acetabular revision reconstructions in 24 patients with pelvic discontinuity who had been treated by the component-cage technique. The mean follow-up was 44.6 months (24 to 68). Failure was defined as migration of a component of > 5 mm.

In 23 hips (88.5%) there was no clinical or radiological evidence of loosening at the last follow-up. The mean Harris hip score improved significantly from 46.6 points (29.5 to 68.5) to 76.6 points (55.5 to 92.0) at two years (p < 0.001). In three hips (11.5%) the construct had migrated at one year after operation. The complications included two dislocations, one infection and one partial palsy of the peroneal nerve.

Our findings indicate that treatment of pelvic discontinuity using the component-cage construct is a reliable option.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 545 - 551
1 Apr 2009
Schnurr C Nessler J Meyer C Schild HH Koebke J König DP

The aim of our study was to investigate whether placing of the femoral component of a hip resurfacing in valgus protected against spontaneous fracture of the femoral neck.

We performed a hip resurfacing in 20 pairs of embalmed femora. The femoral component was implanted at the natural neck-shaft angle in the left femur and with a 10° valgus angle on the right. The bone mineral density of each femur was measured and CT was performed. Each femur was evaluated in a materials testing machine using increasing cyclical loads.

In specimens with good bone quality, the 10° valgus placement of the femoral component had a protective effect against fractures of the femoral neck. An adverse effect was detected in osteoporotic specimens.

When resurfacing the hip a valgus position of the femoral component should be achieved in order to prevent fracture of the femoral neck. Patient selection remains absolutely imperative. In borderline cases, measurement of bone mineral density may be indicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 253 - 257
1 Feb 2007
Seel EH Davies EM

We performed a biomechanical study to compare the augmentation of isolated fractured vertebral bodies using two different bone tamps. Compression fractures were created in 21 vertebral bodies harvested from red deer after determining their initial strength and stiffness, which was then assessed after standardised bipedicular vertebral augmentation using a balloon or an expandable polymer bone tamp.

The median strength and stiffness of the balloon bone tamp group was 6.71 kN (sd 2.71) and 1.885 kN/mm (sd 0.340), respectively, versus 7.36 kN (sd 3.43) and 1.882 kN/mm (sd 0.868) in the polymer bone tamp group. The strength and stiffness tended to be greater in the polymer bone tamp group than in the balloon bone tamp group, but this difference was not statistically significant (strength p > 0.8, and stiffness p = 0.4).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1158 - 1164
1 Sep 2007
Lusty PJ Watson A Tuke MA Walter WL Walter WK Zicat B

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.