The purpose of this study was to determine the sensitivity, specificity
and predictive values of previously reported thresholds of proximal
translation and sagittal rotation of cementless acetabular components
used for revision total hip arthroplasty (THA) at various times
during early follow-up. Migration of cementless acetabular components was measured retrospectively
in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup)
in two groups of patients. In Group A, components were recorded
as not being loose intra-operatively at re-revision THA (52 components/48
patients) and Group B components were recorded to be loose at re-revision
(42 components/36 patients).Aims
Patients and Methods
Few reconstructive techniques are available for patients requiring
complex acetabular revisions such as those involving Paprosky type
2C, 3A and 3B deficiencies and pelvic discontinuity. Our aim was
to describe the development of the patient specific Triflange acetabular
component for use in these patients, the surgical technique and
mid-term results. We include a description of the pre-operative
CT scanning, the construction of a model, operative planning, and
surgical technique. All implants were coated with porous plasma
spray and hydroxyapatite if desired. A multicentre, retrospective review of 95 complex acetabular
reconstructions in 94 patients was performed. A total of 61 (64.2%)
were female. The mean age of the patients was 66 (38 to 85). The
mean body mass index was 29 kg/m2 (18 to 51). Outcome
was reported using the Harris Hip Score (HHS), complications, failures
and survival.Aims
Patients and Methods
Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems. We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).Aims
Patients and Methods
It may not be possible to undertake revision total hip arthroplasty
(THA) in the presence of massive loss of acetabular bone stock using
standard cementless hemispherical acetabular components and metal
augments, as satisfactory stability cannot always be achieved. We
aimed to study the outcome using a reconstruction cage and a porous
metal augment in these patients. A total of 22 acetabular revisions in 19 patients were performed
using a combination of a reconstruction cage and porous metal augments.
The augments were used in place of structural allografts. The mean
age of the patients at the time of surgery was 70 years (27 to 85)
and the mean follow-up was 39 months (27 to 58). The mean number
of previous THAs was 1.9 (1 to 3). All patients had segmental defects
involving more than 50% of the acetabulum and seven hips had an
associated pelvic discontinuity. Aims
Patients and Methods
Pelvic reconstruction after the resection of a tumour around
the acetabulum is a challenging procedure due to the complex anatomy
and biomechanics. Several pelvic endoprostheses have been introduced,
but the rates of complication remain high. Our aim was to review
the use of a stemmed acetabular pedestal cup in the management of
these patients. The study involved 48 patients who underwent periacetabular reconstruction
using a stemmed pedestal cup (Schoellner cup; Zimmer Biomet Inc.,
Warsaw, Indiana) between 2000 and 2013. The indications for treatment included
a primary bone tumour in 27 patients and metastatic disease in 21
patients. The mean age of the patients at the time of surgery was
52 years (16 to 83).Aims
Patients and Methods
The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (Aims
Patients and Methods
The custom triflange is a patient-specific implant
for the treatment of severe bone loss in revision total hip arthroplasty
(THA). Through a process of three-dimensional modelling and prototyping,
a hydroxyapatite-coated component is created for acetabular reconstruction.
There are seven level IV studies describing the clinical results
of triflange components. The most common complications include dislocation
and infection, although the rates of implant removal are low. Clinical
results are promising given the challenging problem. We describe
the design, manufacture and implantation process and review the
clinical results, contrasting them to other methods of acetabular
reconstruction in revision THA. Cite this article:
The aims of this study were to measure sagittal standing and sitting lumbar-pelvic-femoral alignment in patients before and following total hip arthroplasty (THA), and to consider what preoperative factors may influence a change in postoperative pelvic position. A total of 161 patients were considered for inclusion. Patients had a mean age of the remaining 61 years (Aims
Patients and Methods
Osteosarcoma of the pelvis is a particularly difficult tumour
to treat as it often presents late, may be of considerable size
and/or associated with metastases when it presents, and is frequently
chondroid in origin and resistant to chemotherapy. The aim of this study was to review our experience of managing
this group of patients and to identify features predictive of a
poor outcome. Between 1983 and 2014, 121 patients, (74 females and 47 males)
were treated at a single hospital: 74 (61.2%) patients had a primary
osteosarcoma and 47 (38.8%) had an osteosarcoma which was secondary
either to Paget’s disease (22; 18.2%) or to previous pelvic irradiation
(25; 20.7%). The mean age of those with a primary osteosarcoma was 29.3 years
(nine to 76) and their mean follow-up 2.9 years (0 to 29). The mean
age of those with a secondary sarcoma was 61.9 years (15 to 85)
and their mean follow-up was one year (0 to 14). A total of 22 patients with a primary sarcoma (52.4%) and 20
of those with a secondary sarcoma (47.6%) had metastases at the
time of presentation. Aims
Patients and Methods
This study aimed to evaluate implant survival of reverse hybrid
total hip arthroplasty (THA) at medium-term follow-up. A consecutive series of 1082 THAs in 982 patients with mean follow-up
of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21
to 94). Of these, 194 (17.9%) were in patients under 60 years, 663
(61.3%) in female patients and 348 (32.2%) performed by a trainee.
Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%).
Survival analysis was performed and subgroups compared using log
rank tests.Aims
Patients and Methods
To validate the precision of digitally reconstructed radiograph (DRR) radiostereometric analysis (RSA) and the model-based method (MBM) RSA with respect to benchmark marker-based (MM) RSA for evaluation of kinematics in the native hip joint. Seven human cadaveric hemipelves were CT scanned and bone models were segmented. Tantalum beads were placed in the pelvis and proximal femoral bone. RSA recordings of the hips were performed during flexion, adduction and internal rotation. Stereoradiographic recordings were all analyzed with DRR, MBM and MM. Migration results for the MBM and DRR with respect to MM were compared. Precision was assessed as systematic bias (mean difference) and random variation (Pitman’s test for equal variance).Objectives
Methods
An uncemented hemispherical acetabular component
is the mainstay of acetabular revision and gives excellent long-term
results. Occasionally, the degree of acetabular bone loss means that a
hemispherical component will be unstable when sited in the correct
anatomical location or there is minimal bleeding host bone left
for biological fixation. On these occasions an alternative method
of reconstruction has to be used. A major column structural allograft has been shown to restore
the deficient bone stock to some degree, but it needs to be off-loaded
with a reconstruction cage to prevent collapse of the graft. The
use of porous metal augments is a promising method of overcoming
some of the problems associated with structural allograft. If the defect
is large, the augment needs to be protected by a cage to allow ingrowth
to occur. Cup-cage reconstruction is an effective method of treating
chronic pelvic discontinuity and large contained or uncontained
bone defects. This paper presents the indications, surgical techniques and
outcomes of various methods which use acetabular reconstruction
cages for revision total hip arthroplasty. Cite this article:
In order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined. A total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm augment. Each acetabular component and augment was affixed to the bone using two screws, while the method of fixation between the acetabular component and augment varied for the three groups of six hemipelvises: group S, screw fixation only; group SC, screw plus cement fixation; group C, cement fixation only. The implanted hemipelvises were cyclically loaded to three different loading maxima (0.5 kN, 0.9 kN, and 1.8 kN).Objectives
Methods
Peri-acetabular tumour resections and their subsequent
reconstruction are among the most challenging procedures in orthopaedic
oncology. Despite the fact that a number of different pelvic endoprostheses
have been introduced, rates of complication remain high and long-term
results are mostly lacking. In this retrospective study, we aimed to evaluate the outcome
of reconstructing a peri-acetabular defect with a pedestal cup endoprosthesis
after a type 2 or type 2/3 internal hemipelvectomy. A total of 19 patients (11M:8F) with a mean age of 48 years (14
to 72) were included, most of whom had been treated for a primary
bone tumour (n = 16) between 2003 and 2009. After a mean follow-up
of 39 months (28 days to 8.7 years) seven patients had died. After
a mean follow-up of 7.9 years (4.3 to 10.5), 12 patients were alive,
of whom 11 were disease-free. Complications occurred in 15 patients.
Three had recurrent dislocations and three experienced aseptic loosening.
There were no mechanical failures. Infection occurred in nine patients,
six of whom required removal of the prosthesis. Two patients underwent
hindquarter amputation for local recurrence. The implant survival rate at five years was 50% for all reasons,
and 61% for non-oncological reasons. The mean Musculoskeletal Tumor
Society score at final follow-up was 49% (13 to 87). Based on these poor results, we advise caution if using the pedestal
cup for reconstruction of a peri-acetabular tumour resection. Cite this article:
We report the clinical results of glenoid osteotomy in patients
with atraumatic posteroinferior instability associated with glenoid
dysplasia. The study reports results in 211 patients (249 shoulders) with
atraumatic posteroinferior instability. The patients comprised 63
men and 148 women with a mean age of 20 years. The posteroinferior
glenoid surface was elevated by osteotomy at the scapular neck.
A body spica was applied to maintain the arm perpendicular to the
glenoid for two weeks postoperatively. Clinical results were evaluated
using the Rowe score and Japan Shoulder Society Shoulder Instability
Score (JSS-SIS); bone union, osteoarthrosis, and articular congruity
were examined on plain radiographs.Aims
Patients and Methods
The best method of treating unstable pelvic fractures that involve
the obturator ring is still a matter for debate. This study compared
three methods of treatment: nonoperative, isolated posterior fixation
and combined anteroposterior stabilization. The study used data from the German Pelvic Trauma Registry and
compared patients undergoing conservative management (n = 2394),
surgical treatment (n = 1345) and transpubic surgery, including
posterior stabilization (n = 730) with isolated posterior osteosynthesis
(n = 405) in non-complex Type B and C fractures that only involved the
obturator ring anteriorly. Calculated odds ratios were adjusted
for potential confounders. Outcome criteria were intraoperative
and general short-term complications, the incidence of nerve injuries,
and mortality.Aims
Patients and Methods
Until now, there has been no consensus as to whether stemmed
acetabular components are appropriate for use in patients undergoing
revision total hip arthroplasty (THA) who have major acetabular
defects or pelvic discontinuity. We wished to address this deficiency
in the literature. We carried out a retrospective study of 35 patients (six men
and 29 women) with a mean age of 68 years (37 to 87), with major
acetabular defects who underwent revision THA between 2000 and 2012.Aim
Patients and Methods
The aim of this study was to evaluate the functional
and oncological outcome of extracorporeally irradiated autografts
used to reconstruct the pelvis after a P1/2 internal hemipelvectomy. The study included 18 patients with a primary malignant bone
tumour of the pelvis. There were 13 males and five females with
a mean age of 24.8 years (8 to 62). Of these, seven had an osteogenic
sarcoma, six a Ewing’s sarcoma, and five a chondrosarcoma. At a
mean follow-up of 51.6 months (4 to 185), nine patients had died
with metastatic disease while nine were free from disease. Local
recurrence occurred in three patients all of whom eventually died of
their disease. Deep infection occurred in three patients and required
removal of their graft in two while the third underwent a hindquarter
amputation for extensive flap necrosis. The mean Musculoskeletal Tumor Society functional score of the
16 patients who could be followed-up for at least 12 months was
77% (50 to 90). Those 15 patients who completed the Toronto Extremity
Salvage Score questionnaire had a mean score of 71% (53 to 85). Extracorporeal irradiation and re-implantation of bone is a valid
method of reconstruction after an internal hemipelvectomy. It has
an acceptable morbidity and a functional outcome that compares favourably
with other available reconstructive techniques. Cite this article: