The October 2012 Trauma Roundup360 looks at: which patients die from pelvic ring fractures; monolateral distraction osteogenesis; surgical management of pelvic and peroneal blast injuries; weekend warriors at risk of going AWOL; early experience with the locking attachment plate; and fibula nailing - an alternate, and viable technique.
We undertook a retrospective analysis of 306
procedures on 233 patients, with a mean age of 12 years (1 to 21),
in order to evaluate the use of somatosensory evoked potential (SSEP)
monitoring for the early detection of nerve compromise during external
fixation procedures for limb lengthening and correction of deformity.
Significant SSEP changes were identified during 58 procedures (19%).
In 32 instances (10.5%) the changes were transient, and resolved
once the surgical cause had been removed. The remaining 26 (8.5%)
were analysed in two groups, depending on whether or not corrective
action had been performed in response to critical changes in the
SSEP recordings. In 16 cases in which no corrective action was taken,
13 (81.2%, 4.2% overall) developed a post-operative neurological
deficit, six of which were permanent and seven temporary, persisting
for five to 18 months. In the ten procedures in which corrective
action was taken, four patients (40%, 1.3% overall) had a temporary
(one to eight months) post-operative neuropathy and six had no deficit. After appropriate intervention in response to SSEP changes, the
incidence and severity of neurological deficits were significantly
reduced, with no cases of permanent neuropathy. SSEP monitoring
showed 100% sensitivity and 91% specificity for the detection of
nerve injury during external fixation. It is an excellent diagnostic
technique for identifying nerve lesions when they are still highly
reversible.
We describe a near-fatal event, probably due to air embolism, following an air arthrogram for developmental hip dysplasia in a baby aged four months. The sequence of events and the subsequent treatment are described. There is little information about this complication in the literature. The presumed mechanism and alternative methods for confirmation of placement of the needle are discussed. We no longer use air arthrography in children.
Between June 1999 and May 2003 we undertook direct primary closure of the skin wounds of 173 patients with Gustilo and Anderson grade-IIIA and grade-IIIB open fractures. These patients were selected from a consecutive group of 557 with type-III injuries presenting during this time. Strict criteria for inclusion in the study included debridement within 12 hours of injury, no sewage or organic contamination, no skin loss either primarily or secondarily during debridement, a Ganga Hospital open injury skin score of 1 or 2 with a total score of ten or less, the presence of bleeding skin margins, the ability to approximate wound edges without tension and the absence of peripheral vascular disease. In addition, patients with polytrauma were excluded. At a mean follow-up of 6.2 years (5 to 7), the outcome was excellent in 150 (86.7%), good in 11 (6.4%) and poor in 12 (6.9%). A total of 33 complications occurred in 23 patients including superficial infection in 11, deep infection in five and the requirement for a secondary skin flap in three. Six patients developed nonunion requiring further surgery, one of whom declined additional measures to treat an established infected nonunion. Immediate skin closure when performed selectively with the above indications proved to be a safe procedure.
We reviewed 27 diabetic patients who sustained a tibial fracture treated with a reamed intramedullary nail and compared them with a control group who did not have diabetes. There were 23 closed fractures and four were open. Union was delayed until after six months in 12 of the 23 (52%) diabetic patients with closed fractures and ten of the 23 (43%) control patients (p = 0.768). In two patients with diabetes (9%), closed tibial fractures failed to unite and required exchange nailing, whereas all closed fractures in the control group healed without further surgery (p = 0.489). In both the diabetic and control groups with closed fractures two patients (9%) developed superficial infections. There were two (9%) deep infections in diabetic patients with closed fractures, but none in the control group (p = 0.489). Overall, there was no significant difference in the rate of complications between the diabetic patients and the control group, but there was a tendency for more severe infections in patients with diabetes.
We report a case of fatal haemorrhage following a low-energy fracture of the pubic ramus in an 85-year-old woman.
Compartment syndrome of the foot is usually associated with trauma, and if untreated may result in deformity and loss of function. We report a case of spontaneous compartment syndrome of the foot presenting with severe unremitting pain. The diagnosis was supported by measurements of compartment pressures and the symptoms resolved after surgical decompression. Spontaneous compartment syndrome in the leg has been described in a small number of cases, but there has been no previous report involving the foot. We believe that this case highlights the importance of suspecting a spontaneous compartment syndrome of the foot if the appropriate symptoms are present but there is no clear cause. We also believe that compartment pressure measurement assists in the decision to undertake surgical decompression.
Negative pressure wound therapy (NPWT) and vessel loop assisted
closure are two common methods used to assist with the closure of
fasciotomy wounds. This retrospective review compares these two
methods using a primary outcome measurement of skin graft requirement. A retrospective search was performed to identify patients who
underwent fasciotomy at our institution. Patient demographics, location
of the fasciotomy, type of assisted closure, injury characteristics,
need for skin graft, length of stay and evidence of infection within
90 days were recorded.Introduction
Methods
To assess the sensitivity and specificity of self-reported osteoporosis
compared with dual energy X-ray absorptiometry (DXA) defined osteoporosis,
and to describe medication use among participants with the condition. Data were obtained from a population-based longitudinal study
and assessed for the prevalence of osteoporosis, falls, fractures
and medication use. DXA scans were also undertaken.Objectives
Methods
The purpose of this study was to investigate
whether a gender-specific high-flexion posterior-stabilised (PS)
total knee replacement (TKR) would offer advantages over a high-flex
PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain
and satisfaction, as well as during activity. A total of 24 female
patients with bilateral osteoarthritis entered this prospective,
blind randomised trial in which they received a high-flex PS TKR
in one knee and a gender-specific high-flexion PS TKR in the other
knee. At follow-up, patients were assessed clinically measuring
ROM, and questioned about pain, satisfaction and daily ‘feel’ of
each knee. Patients underwent gait analysis pre-operatively and
at one year, which yielded kinematic, kinetic and temporospatial
parameters indicative of knee function during gait. At final follow-up
we found no statistically significant differences in ROM (p = 0.82).
The median pain score was 0 (0 to 8) in both groups (p = 0.95).
The median satisfaction score was 9 (4 to 10) in the high-flex group
and 8 (0 to 10) in the gender-specific group (p = 0.98). The median
‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to
10) in the gender-specific group (p = 0.66). Gait analysis showed
no statistically significant differences between the two prosthetic
designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with
We studied 70 consecutive patients with adolescent idiopathic scoliosis who underwent corrective surgery. They were divided into two groups. In the study group of 38 patients one or more modern blood-conservation measures was used peri-operatively. The 32 patients in the control group did not have these measures. Both groups were similar in regard to age, body-weight, the number of levels fused and the type of surgery. Only two patients in the study group were transfused with homologous blood and these transfusions were ‘off-protocol’. Wastage of autologous pre-donated units was minimal (6 of 83 units). By contrast, all patients in the control group were transfused with homologous blood. In the study group there was a significant decrease (p = 0.005) in the estimated blood loss when all the blood-conservation methods were used. The use of blood-conservation measures, the lowering of the haemoglobin trigger for transfusion and the education of the entire team involved in the care of the patient can prevent the need for homologous blood transfusion in patients undergoing surgery for adolescent idiopathic scoliosis.
The stress response to trauma is the summation of the physiological response to the injury (the ‘first hit’) and by the response to any on-going physiological disturbance or subsequent trauma surgery (the ‘second hit’). Our animal model was developed in order to allow the study of each of these components of the stress response to major trauma. High-energy, comminuted fracture of the long bones and severe soft-tissue injuries in this model resulted in a significant tropotropic (depressor) cardiovascular response, transcardiac embolism of medullary contents and activation of the coagulation system. Subsequent stabilisation of the fractures using intramedullary nails did not significantly exacerbate any of these responses.
Following arthroplasty of the knee, the patient’s
perception of improvement in symptoms is fundamental to the assessment
of outcome. Better clinical outcome may offset the inferior survival
observed for some types of implant. By examining linked National
Joint Registry (NJR) and patient-reported outcome measures (PROMs)
data, we aimed to compare PROMs collected at a minimum of six months
post-operatively for total (TKR: n = 23 393) and unicondylar knee
replacements (UKR: n = 505). Improvements in knee-specific (Oxford
knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared
and adjusted for case-mix differences using multiple regression.
Whereas the improvements in the OKS and EQ-5D were significantly
greater for TKR than for UKR, once adjustments were made for case-mix
differences and pre-operative score, the improvements in the two
scores were not significantly different. The adjusted mean differences
in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI)
-0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37),
respectively. We found no difference in the improvement of either knee-specific
or general health outcomes between TKR and UKR in a large cohort
of registry patients. With concerns about significantly higher revision
rates for UKR observed in worldwide registries, we question the
widespread use of an arthroplasty that does not confer a significant
benefit in clinical outcome.
We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (before the onset of the procedure) and ward staff. The operations were performed by a single surgeon at one hospital using a uniform surgical approach, instrumentation, technique and release sequence. The only variable in the two groups of patients was the use of single tracker pins of the imageless navigation system in the tibia and femur of the navigated group and intramedullary femoral and tibial alignment jigs in the non-navigated group. Acetabular Doppler signals were obtained in 14 patients in the computer-assisted group and nine (90%) in the conventional group, in whom high-intensity signals were detected in seven computer-assisted patients (50%) and in all of the non-navigated patients. In the computer-assisted group no patient had more than two detectable emboli, with a mean of 0.64 (SD 0.74). In the non-navigated group the number of emboli ranged from one to 43 and six patients had more than two detectable emboli, with a mean of 10.7 ( Our findings show that computer-assisted total knee arthroplasty, when compared with conventional jig-based surgery, significantly reduces systemic emboli as detected by transcranial Doppler ultrasonography.
Systemic capillary leak syndrome, or the Clarkson syndrome, is an extremely rare condition in which increased capillary permeability results in a massive shift of fluid into the extravascular space. This is followed rapidly by hypotensive shock, haemoconcentration, and, potentially, substantial oedema of the limbs resulting in an acute compartment syndrome. It is important for orthopaedic surgeons to be aware of this syndrome as our medical colleagues, who initially care for these patients, are less familiar with the diagnosis and the need for emergency management of the associated compartment syndrome should it develop. There have been fewer than 100 cases of this entity reported. This case report is the first to describe the subsequent development of a compartment syndrome in all four limbs. Clinical vigilance and continuous monitoring of intracompartmental pressure is necessary in these patients in order to help reduce limb-threatening complications.
Using a computer-based quality assurance program, we analysed peri-operative data on 160 patients undergoing one-stage bilateral hip or knee arthroplasties under regional anaesthesia with routine anaesthetic monitoring and only using peripheral intravenous access for peri-operative safety. We monitored defined intra-operative adverse events such as hypotension, myocardial ischaemia, arrhythmias, hypovolaemia, hypertension and early post-operative complications. We also determined post-operative hip and knee function, and patient satisfaction with different aspects of the anaesthetic management. Those patients undergoing one-stage bilateral arthroplasties were matched according to a cross-stratification which used three variables (American Society of Anesthesiologists’ physical status scoring system, age and joint replaced) to patients undergoing unilateral hip or knee arthroplasties. Serious intra-operative adverse events were, with the exception of intra-operative hypotension, very infrequent in patients undergoing bilateral (nine adverse events) as well as unilateral arthroplasties (five adverse events). Early post-operative complications were also infrequent in both groups. However, the risks of receiving a heterologous blood transfusion (odds ratio 2.5; 95% confidence interval (CI) 1.3 to 5.0, estimated by exact conditional logistic regression) or vasoactive drugs (odds ratio 3.9; 95% CI 2.0 to 7.8) were significantly greater for patients undergoing bilateral operations. Patient satisfaction with anaesthesia was high; all patients who underwent the one-stage bilateral operation would choose the same anaesthetic technique again.
A silver-containing hydroxyapatite (Ag-HA) coating has been developed using thermal spraying technology. We evaluated the osteoconductivity of this coating on titanium (Ti) implants in rat tibiae in relation to bacterial infection in joint replacement. At 12 weeks, the mean affinity indices of bone formation of a Ti, an HA, a 3%Ag-HA and a 50%Ag-HA coating were 97.3%, 84.9%, 81.0% and 40.5%, respectively. The mean affinity indices of bone contact of these four coatings were 18.8%, 83.7%, 77.2% and 40.5%, respectively. The indices of bone formation and bone contact around the implant of the 3%Ag-HA coating were similar to those of the HA coating, and no significant differences were found between them (bone formation, p = 0.99; bone contact, p = 0.957). However, inhibition of bone formation was observed with the 50%Ag-HA coating. These results indicate that the 3%Ag-HA coating has low toxicity and good osteoconductivity, and that the effect of silver toxicity on osteoconductivity depends on the dose.
The major advantage of hip resurfacing is the decreased amount of bone resection compared with a standard total hip replacement. Fracture of the femoral neck is the most common early complication and poor bone quality is a major risk factor. We undertook a prospective consecutive case control study examining the effect of bone mineral density changes in patients undergoing hip resurfacing surgery. A total of 423 patients were recruited with a mean age of 54 years (24 to 87). Recruitment for this study was dependent on pre-operative bilateral femoral bone mineral density results not being osteoporotic. The operated and non-operated hips were assessed. Bone mineral density studies were repeated over a two-year period. The results showed no significant deterioration in the bone mineral density in the superolateral region in the femoral neck, during that period. These findings were in the presence of a markedly increased level of physical activity, as measured by the short-form 36 health survey physical function score.
A 25-year-old male weightlifter felt increasing intractable low back pain during training but denied any acute injury. The physical examination, blood parameters, radiographs and MRI were unremarkable. He had been treated non-operatively by various means, with only temporary relief. The pressures in the lumbar paraspinal compartment were abnormally high and he was treated by surgical decompression. This gave rapid relief, he returned to training, and one year later the pain had not recurred.
Up to 20% of patients are not satisfied with the outcome following total knee replacement (TKR). This study investigated the pre- and post-operative predictors of dissatisfaction in a large cohort of patients undergoing TKR. We assessed 1217 consecutive patients between 2006 and 2008 both before operation and six months after, using the Short-form (SF)-12 health questionnaire and the Oxford Knee Score. Detailed information concerning comorbidity was also gathered. Satisfaction was measured at one year when 18.6% (226 of 1217) of patients were unsure or dissatisfied with their replacement and 81.4% (911 of 1217) were satisfied or very satisfied. Multivariate regression analysis was performed to identify independent predictors of dissatisfaction. Significant (p <
0.001) predictors at one year included the pre-operative SF-12 mental component score, depression and pain in other joints, the six-month SF-12 score and poorer improvement in the pain element of the Oxford Knee Score. Patient expectations were highly correlated with satisfaction. Satisfaction following TKR is multifactorial. Managing the expectations and mental health of the patients may reduce dissatisfaction. However, the most significant predictor of dissatisfaction is a painful total knee replacement.