The April 2015 Shoulder &
Elbow Roundup360 looks at: Distal clavicular resection not indicated in cuff repair?; Platelet-rich plasma in rotator cuff repair; Radial head geometry: time to change?; Heterotopic ossification in elbow trauma; Another look at heterotopic ossification in the humerus; Triceps on for total elbow arthroplasty?; Predicting outcomes in rotator cuff repair; Deltoid fatty infiltration and reverse shoulder arthroplasty
Local corticosteroid infiltration is a common practice of treatment
for lateral epicondylitis. In recent studies no statistically significant
or clinically relevant results in favour of corticosteroid injections
were found. The injection of autologous blood has been reported
to be effective for both intermediate and long-term outcomes. It
is hypothesised that blood contains growth factors, which induce
the healing cascade. A total of 60 patients were included in this prospective randomised
study: 30 patients received 2 ml autologous blood drawn from contralateral
upper limb vein + 1 ml 0.5% bupivacaine, and 30 patients received
2 ml local corticosteroid + 1 ml 0.5% bupivacaine at the lateral
epicondyle. Outcome was measured using a pain score and Nirschl
staging of lateral epicondylitis. Follow-up was continued for total
of six months, with assessment at one week, four weeks, 12 weeks
and six months.Objectives
Methods
The April 2013 Research Roundup360 looks at: when the ‘residency cake’ is done; steroids, stem cells and tendons; what exactly is osteoarthritis; platelet-rich plasma; CRPS; d-Dimer for DVT; reducing bacterial adhesion; and fin or limb?
We reviewed the records of 107 consecutive patients who had undergone surgery for disruption of the knee extensor mechanism to test whether an association existed between rupture of the quadriceps tendon and the presence of a patellar spur. The available standard pre-operative lateral radiographs were examined to see if a patellar spur was an indicator for rupture of the quadriceps tendon in this group of patients. Of the 107 patients, 12 underwent repair of a
Peri-tendinous injection of local anaesthetic,
both alone and in combination with corticosteroids, is commonly performed
in the treatment of tendinopathies. Previous studies have shown
that local anaesthetics and corticosteroids are chondrotoxic, but
their effect on tenocytes remains unknown. We compared the effects
of lidocaine and ropivacaine, alone or combined with dexamethasone,
on the viability of cultured bovine tenocytes. Tenocytes were exposed
to ten different conditions: 1) normal saline; 2) 1% lidocaine;
3) 2% lidocaine; 4) 0.2% ropivacaine; 5) 0.5% ropivacaine; 6) dexamethasone
(dex); 7) 1% lidocaine+dex; 8) 2% lidocaine+dex; 9) 0.2% ropivacaine+dex;
and 10) 0.5% ropivacaine+dex, for 30 minutes. After a 24-hour recovery
period, the viability of the tenocytes was quantified using the
CellTiter-Glo viability assay and fluorescence-activated cell sorting
(FACS) for live/dead cell counts. A 30-minute exposure to lidocaine
alone was significantly toxic to the tenocytes in a dose-dependent
manner, but a 30-minute exposure to ropivacaine or dexamethasone
alone was not significantly toxic. Dexamethasone potentiated ropivacaine tenocyte toxicity at higher
doses of ropivacaine, but did not potentiate lidocaine tenocyte
toxicity. As seen in other cell types, lidocaine has a dose-dependent
toxicity to tenocytes but ropivacaine is not significantly toxic.
Although dexamethasone alone is not toxic, its combination with
0.5% ropivacaine significantly increased its toxicity to tenocytes.
These findings might be relevant to clinical practice and warrant
further investigation.
Drug therapy forms an integral part of the management
of many orthopaedic conditions. However, many medicines can produce
serious adverse reactions if prescribed inappropriately, either
alone or in combination with other drugs. Often these hazards are
not appreciated. In response to this, the European Union recently
issued legislation regarding safety measures which member states
must adopt to minimise the risk of errors of medication. In March 2014 the Medicines and Healthcare products Regulatory
Agency and NHS England released a Patient Safety Alert initiative
focussed on errors of medication. There have been similar initiatives
in the United States under the auspices of The National Coordinating
Council for Medication Error and The Joint Commission on the Accreditation
of Healthcare Organizations. These initiatives have highlighted
the importance of informing and educating clinicians. Here, we discuss common drug interactions and contra-indications
in orthopaedic practice. This is germane to safe and effective clinical
care. Cite this article:
We performed two independent, randomised, controlled trials in order to assess the potential benefits of immediate weight-bearing mobilisation after rupture of the tendo Achillis. The first trial, on operatively-treated patients showed an improved functional outcome for patients mobilised fully weight-bearing after surgical repair. Two cases of re-rupture in the treatment group suggested that careful patient selection is required as patients need to follow a structured rehabilitation regimen. The second trial, on conservatively-treated patients, provided no evidence of a functional benefit from immediate weight-bearing mobilisation. However, the practical advantages of immediate weight-bearing did not predispose the patients to a higher complication rate. In particular, there was no evidence of tendon lengthening or a higher re-rupture rate. We would advocate immediate weight-bearing mobilisation for the rehabilitation of all patients with rupture of the tendo Achillis.
In patients with a tumour affecting the distal
ulna it is difficult to preserve the function of the wrist following extensive
local resection. We report the outcome of 12 patients (nine female,
three male) who underwent excision of the distal ulna without local
soft-tissue reconstruction. In six patients, an aggressive benign
tumour was present and six had a malignant tumour. At a mean follow-up
of 64 months (15 to 132) the mean Musculoskeletal Tumour score was
64% (40% to 93%) and the mean DASH score was 35 (10 to 80). The
radiological appearances were satisfactory in most patients. Local
recurrence occurred in one patient with benign disease and two with
malignant disease. The functional outcome was thus satisfactory
at a mean follow-up in excess of five years, with a relatively low
rate of complications. The authors conclude that complex reconstructive
soft-tissue procedures may not be needed in these patients. Cite this article:
We investigated the effect of mitomycin-C on the reduction of the formation of peritendinous fibrous adhesions after tendon repair. In 20 Wistar albino rats the tendo Achillis was cut and repaired using a modified Kessler technique. The rats were divided into two equal groups. In group 1, an injection of mitomycin-C was placed between the tendon and skin of the right leg. In group 2, an identical volume of sterile normal saline was injected on the left side in a similar fashion. All the rats received mitomycin-C or saline for four weeks starting from the day of operation. The animals were killed after 30 days. The formation of peritendinous fibrous tissue, the inflammatory reaction and tendon healing were evaluated. The tensile strength of the repaired tendons was measured biomechanically. Microscopic evidence of the formation of adhesions and inflammation was less in group 1. There was no significant difference in the tensile load required to rupture the repaired tendons in the two groups. Mitomycin-C may therefore provide a simple and inexpensive means of preventing of post-operative adhesions.
The use of ultrasound in the diagnosis and management of disorders of the tendo Achillis is discussed. Some of the pathological processes which occur in Achilles tendinopathy can be identified by ultrasound, which may also be used to direct local treatment.
We present a review of claims made to the NHS
Litigation Authority (NHSLA) by patients with conditions affecting the
shoulder and elbow, and identify areas of dissatisfaction and potential
improvement. Between 1995 and 2012, the NHSLA recorded 811 claims
related to the shoulder and elbow, 581 of which were settled. This
comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total
of £18.2 million was paid out in settled claims. Overall diagnosis,
mismanagement and intra-operative nerve injury were the most common
reasons for litigation. The highest cost paid out resulted from
claims dealing with incorrect, missed or delayed diagnosis, with
just under £6 million paid out overall. Fractures and dislocations
around the shoulder and elbow were common injuries in this category.
All 11 claims following wrong-site surgery that were settled led
to successful payouts. This study highlights the diagnoses and procedures that need
to be treated with particular vigilance. Having an awareness of
the areas that lead to litigation in shoulder and elbow surgery
will help to reduce inadvertent risks to patients and prevent dissatisfaction
and possible litigation. Cite this article:
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a fracture of the distal radius. Cite this article:
The October 2013 Wrist &
Hand Roundup360 looks at: Cost effectiveness of Dupuytren’s surgery; A 'new horizon' in distal radius imaging; Undisplaced means undisplaced; The mystery of the distal radial fracture continues; How thick is thick enough?: articular cartilage step off revisited; Is the midcarpal joint more important than we think?; Plates and Kirschner wires; Better early results with an IM nail?
We reviewed the outcome of 69 uncemented, custom-made,
distal femoral endoprosthetic replacements performed in 69 patients
between 1994 and 2006. There were 31 women and 38 men with a mean
age at implantation of 16.5 years (5 to 37). All procedures were
performed for primary malignant bone tumours of the distal femur.
At a mean follow-up of 124.2 months (4 to 212), 53 patients were
alive, with one patient lost to follow-up. All nine implants (13.0%)
were revised due to aseptic loosening at a mean of 52 months (8
to 91); three implants (4.3%) were revised due to fracture of the
shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic
fracture. Bone remodelling associated with periosteal cortical thinning
adjacent to the uncemented intramedullary stem was seen in 24 patients
but this did not predispose to failure. All aseptically loose implants
in this series were diagnosed to be loose within the first five
years. The results from this study suggest that custom-made uncemented
distal femur replacements have a higher rate of aseptic loosening
compared to published results for this design when used with cemented
fixation. Loosening of uncemented replacements occurs early indicating
that initial fixation of the implant is crucial. Cite this article:
Tendinopathy is a debilitating musculoskeletal
condition which can cause significant pain and lead to complete rupture
of the tendon, which often requires surgical repair. Due in part
to the large spectrum of tendon pathologies, these disorders continue
to be a clinical challenge. Animal models are often used in this
field of research as they offer an attractive framework to examine
the cascade of processes that occur throughout both tendon pathology and
repair. This review discusses the structural, mechanical, and biological
changes that occur throughout tendon pathology in animal models,
as well as strategies for the improvement of tendon healing. Cite this article:
The role of inflammatory cells and their products in tendinopathy is not completely understood. Pro-inflammatory cytokines are upregulated after oxidative and other forms of stress. Based on observations that increased cytokine expression has been demonstrated in cyclically-loaded tendon cells we hypothesised that because of their role in oxidative stress and apoptosis, pro-inflammatory cytokines may be present in rodent and human models of tendinopathy. A rat supraspinatus tendinopathy model produced by running overuse was investigated at the genetic level by custom micro-arrays. Additionally, samples of torn supraspinatus tendon and matched intact subscapularis tendon were collected from patients undergoing arthroscopic shoulder surgery for rotator-cuff tears and control samples of subscapularis tendon from ten patients with normal rotator cuffs undergoing arthroscopic stabilisation of the shoulder were also obtained. These were all evaluated using semiquantitative reverse transcription polymerase chain-reaction and immunohistochemistry. We identified significant upregulation of pro-inflammatory cytokines and apoptotic genes in the rodent model (p = 0.005). We further confirmed significantly increased levels of cytokine and apoptotic genes in human supraspinatus and subscapularis tendon harvested from patients with rotator cuff tears (p = 0.0008). These findings suggest that pro-inflammatory cytokines may play a role in tendinopathy and may provide a target for preventing tendinopathies.
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article:
The February 2013 Trauma Roundup360 looks at: the risk of ankle fractures; absorbable implants; minimally invasive heel fracture fixation; pertrochanteric fractures; arthroplasty and intracapsular hip fractures; and extensor mechanism disruption.
We reviewed 5086 patients with a mean age of
30 years (9 to 69) undergoing primary reconstruction of the anterior cruciate
ligament (ACL) in order to determine the incidence of secondary
pathology with respect to the time between injury and reconstruction.
There was an increasing incidence of medial meniscal tears and chondral damage,
but not lateral meniscal tears, with increasing intervals before
surgery. The chances of requiring medial meniscal surgery was increased
by a factor of two if ACL reconstruction was delayed more than five
months, and increased by a factor of six if surgery was delayed
by >
12 months. The effect of delaying surgery on medial meniscal injury
was also pronounced in the patients aged <
17 years, where a
delay of five to 12 months doubled the odds of medial meniscal surgery
(odds ratio (OR) 2.0, p = 0.001) and a delay of >
12 months quadrupled
the odds (OR 4.3, p = 0.001). Increasing age was associated with
a greater odds of chondral damage (OR 4.6, p = 0.001) and medial meniscal
injury (OR 2.9, p = 0.001), but not lateral meniscal injury. The
gender split (3251 men, 1835 women) revealed that males had a greater
incidence of both lateral (34% (n = 1114) Cite this article: