Advertisement for orthosearch.org.uk
Results 101 - 120 of 8721
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims

The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results.

Methods

Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 685 - 686
1 Jun 2018
Haddad FS


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims. Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively. Patients and Methods. A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years. Results. The median age of the 238 patients was 65.0 years (interquartile range (IQR) 59.0 to 73.0), the median body mas index was 30.0 (IQR 27.5 to 33.0) and 51.7% were male. There were no intra-operative complications. There was a significant improvement in the median OKS at six weeks (34, IQR 31.0 to 37.0), one year (38, IQR 29.0 to 43.0) and five years (37, IQR 27.0 to 42.0) when compared with the pre-operative scores (16, IQR 13.0 to 19.0) (all p = < 0.01). No patient had progressive radiolucent lines or loosening. A total of 16 patients had died by five years. The cumulative survival at five years was 98.8% and the mean survival time was 5.8 years (95% confidence interval 5.6 to 5.9). A total of seven OUKAs (2.7%) were revised; three within five years and four thereafter, between 5.1 and 5.7 years post-operatively. Five (1.9%) had re-operations within five years. Conclusion. The proportion of patients requiring revision at five years is lower than that generally reported for UKA. These findings add support for the use of the cementless OUKA outside the design centre. Longer follow-up is required. Cite this article: Bone Joint J 2017;99-B:623–31


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted. Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up. Cite this article: Bone Joint J 2015; 97-B:681–8


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1559 - 1564
1 Dec 2018
McConnell JS Saunders PRJ Young SK

Aims

Cementless femoral stems must be correctly sized and well-seated to obtain satisfactory biological fixation. The change in sound that occurs during impaction of the femoral broach is said to indicate good fit, but this has not been widely studied. We set out to find whether the presence or absence of these sound changes could predict correct sizing.

Patients and Methods

We recorded the sound generated during femoral broaching for 105 cementless total hip arthroplasties using the Corail stem. Four cases were excluded, leaving 101 recordings for analysis. There were 36 male patients and 65 female patients, with a mean age of 69.9 years (sd 12.3) and median body mass index (BMI) of 29 kg/m2 (interquartile range (IQR) 26 to 32). The recordings were analyzed to identify the frequencies of the sounds produced during impaction of the femoral broach.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims. Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA. Patients and Methods. Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three. Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89). Results. The ROM of the elbow did not improve significantly. The mean EFAS and MAESS scores improved significantly six months post-operatively (18.6 points, standard deviation (. sd. ) 7.7; p = 0.03 and 28.8 points, . sd . 8.6; p = 0.006, respectively) and continued to improve slightly or reached a plateau. The mean pain scores at rest (Z = -3.2, p = 0.001) and during activity (Z = -3.2, p = 0.001), and stability (Z = -3.0, p = 0.003) improved significantly six months post-operatively. Thereafter scores continued to improve slightly or a plateau was reached. There were no signs of loosening. Conclusion. Revision surgery using the Latitude TEA results in improvement of functionality, reduced pain and better stability of the elbow. Improvement of ROM of the elbow should not be expected. Cite this article: Bone Joint J 2016;98-B:1086–92


Bone & Joint 360
Vol. 5, Issue 4 | Pages 42 - 43
1 Aug 2016
Foy MA


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 410 - 413
1 Mar 2016
Costa ML Jameson SS Reed MR

Aims. Our aim, using English Hospital Episode Statistics data before during and after the Distal Radius Acute Fracture Fixation Trial (DRAFFT), was to assess whether the results of the trial affected clinical practice. Patients and Methods. Data were grouped into six month intervals from July 2005 to December 2014. All patient episodes in the National Health Service involving emergency surgery for an isolated distal radial fracture were included. Results. Clinical practice in England had not changed in the five years before DRAFFT: 75% of patients were treated with plate fixation versus 12% with Kirschner (K)-wires. After the publication of the trial, the proportion of patients having K-wire fixation rose to 42% with a concurrent fall in the proportion having fixation with a plate to 48%. The proportion of ‘other’ procedures stayed the same. Take home message. It appears that surgeons in the United Kingdom do change their practice in response to large, pragmatic, multicentre clinical trials in musculoskeletal trauma. Cite this article: Bone Joint J 2016;98-B:410–13


Bone & Joint Research
Vol. 8, Issue 7 | Pages 288 - 289
1 Jul 2019
Mayne E Raut P Memarzadeh A Arora A Khanduja V


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 680 - 684
1 May 2018
Perry DC Wright JG Cooke S Roposch A Gaston MS Nicolaou N Theologis T

Aims. High-quality clinical research in children’s orthopaedic surgery has lagged behind other surgical subspecialties. This study used a consensus-based approach to identify research priorities for clinical trials in children’s orthopaedics. Methods. A modified Delphi technique was used, which involved an initial scoping survey, a two-round Delphi process and an expert panel formed of members of the British Society of Children’s Orthopaedic Surgery. The survey was conducted amongst orthopaedic surgeons treating children in the United Kingdom and Ireland. Results. A total of 86 clinicians contributed to both rounds of the Delphi process, scoring priorities from one (low priority) to five (high priority). Elective topics were ranked higher than those relating to trauma, with the top ten elective research questions scoring higher than the top question for trauma. Ten elective, and five trauma research priorities were identified, with the three highest ranked questions relating to the treatment of slipped capital femoral epiphysis (mean score 4.6/ 5), Perthes’ disease (4.5) and bone infection (4.5). Conclusion. This consensus-based research agenda will guide surgeons, academics and funders to improve the evidence in children’s orthopaedic surgery and encourage the development of multicentre clinical trials. Cite this article: Bone Joint J 2018;100-B:680–4


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 928 - 932
1 Jul 2007
Hand GCR Athanasou NA Matthews T Carr AJ

We treated 22 patients with a diagnosis of primary frozen shoulder resistant to conservative treatment by manipulation under anaesthetic and arthroscopic release of the rotator interval, at a mean time from onset of 15 months (3 to 36). Biopsies were taken from this site and histological and immunocytochemical analysis was performed to identify the types of cell present. The tissue was characterised by the presence of fibroblasts, proliferating fibroblasts and chronic inflammatory cells. The infiltrate of chronic inflammatory cells was predominantly made up of mast cells, with T cells, B cells and macrophages also present. The pathology of frozen shoulder includes a chronic inflammatory response with fibroblastic proliferation which may be immunomodulated



The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1359 - 1365
1 Oct 2014
Large R Tambe A Cresswell T Espag M Clark DI

Medium-term results of the Discovery elbow replacement are presented. We reviewed 51 consecutive primary Discovery total elbow replacements (TERs) implanted in 48 patients. The mean age of the patients was 69.2 years (49 to 92), there were 19 males and 32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69). A total of six patients were lost to follow-up. Statistically significant improvements in range movement and Oxford Elbow Score were found (p < 0.001). Radiolucent lines were much more common in, and aseptic loosening was exclusive to, the humeral component. Kaplan–Meier survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for aseptic loosening. In four TERs, periprosthetic infection occurred resulting in failure. A statistically significant association between infection and increased BMI was found (p = 0.0268). Triceps failure was more frequent after the Mayo surgical approach and TER performed after previous trauma surgery. No failures of the implant were noted. . Our comparison shows that the Discovery has early clinical results that are similar to other semi-constrained TERs. We found continued radiological surveillance with particular focus on humeral lucency is warranted and has not previously been reported. Despite advances in the design of total elbow replacement prostheses, rates of complication remain high. Cite this article: Bone Joint J 2014;96-B:1359–65


Bone & Joint 360
Vol. 7, Issue 3 | Pages 41 - 42
1 Jun 2018
Foy MA


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 720 - 724
1 Jun 2009
Ollivere B Darrah C Brankin RC Donnell ST Walton NP

We report the follow-up at 12 years of the use of the Elite Plus total hip replacement (THR). We have previously reported the results at a mean of 6.4 years. Of the 217 patients (234 THRs), 83 had died and nine had been lost to follow-up. The patients were reviewed radiologically and clinically using the Oxford hip score. Of the 234 THRs, 19 (8.1%) had required a revision by the final follow-up in all but one for aseptic loosening. Survivorship analysis for revision showed a survival of 93.9% (95% confidence interval (CI) 89.2 to 96.5) at ten years, and of 88.0% (95% CI 81.8 to 92.3) at 12 years. At the final follow-up survival analysis showed that 37% (95% CI 37.3 to 44.7) of the prostheses had either failed radiologically or had been revised. Patients with a radiologically loose femoral component had a significantly poorer Oxford hip score than those with a well-fixed component (p = 0.03). Radiological loosening at 6.4 years was predictive of failure at 12 years. Medium-term radiographs and clinical scores should be included in the surveillance of THR to give an early indication of the performance of specific implants


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). . In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. Cite this article: Bone Joint J 2015; 97-B:1126–31


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 188 - 194
1 Feb 2014
Gilbody J Taylor C Bartlett GE Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Impaction bone grafting for the reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. Between 1995 and 2001 we used this technique in acetabular reconstruction, in combination with a cemented component, in 304 hips in 292 patients revised for aseptic loosening. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of ten years after the index operation. Mean follow-up was 12.4 years (. sd. 1.5) (10.0 to 16.0). Kaplan–Meier survival with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared radiologically loose. . Cite this article: Bone Joint J 2014;96-B:188–94


Bone & Joint 360
Vol. 6, Issue 6 | Pages 41 - 43
1 Dec 2017
Foy MA


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 121 - 123
1 Feb 2019
Robinson AHN Johnson-Lynn SE Humphrey JA Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks. A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group. We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures