Injury to the common peroneal nerve was present in 14 of 55 patients (25%) with dislocation of the knee. All underwent ligament reconstruction. The most common presenting direction of the dislocation was anterior or anteromedial with associated disruption of both cruciate ligaments and the posterolateral structures of the knee. Palsy of the common peroneal nerve was present in 14 of 34 (41%) of these patients. Complete rupture of the nerve was seen in four patients and a lesion in continuity in ten. Three patients with lesions in continuity, but with less than 7 cm of the nerve involved, had complete recovery within six to 18 months. In the remaining seven with more extensive lesions, two regained no motor function, and one had only MRC grade-2 function. Four patients regained some weak dorsiflexion or eversion (MRC grade 3 or 4). Some sensory recovery occurred in all seven of these patients, but was incomplete. In summary, complete recovery occurred in three (21%) and partial recovery of useful motor function in four (29%). In the other seven (50%) no useful motor or sensory function returned.
Coronal plane fractures of the posterior femoral
condyle, also known as Hoffa fractures, are rare. Lateral fractures are
three times more common than medial fractures, although the reason
for this is not clear. The exact mechanism of injury is likely to
be a vertical shear force on the posterior femoral condyle with
varying degrees of knee flexion. These fractures are commonly associated
with high-energy trauma and are a diagnostic and surgical challenge. Hoffa
fractures are often associated with inter- or supracondylar distal
femoral fractures and CT scans are useful in delineating the coronal
shear component, which can easily be missed. There are few recommendations
in the literature regarding the surgical approach and methods of
fixation that may be used for this injury. Non-operative treatment
has been associated with poor outcomes. The goals of treatment are
anatomical reduction of the articular surface with rigid, stable
fixation to allow early mobilisation in order to restore function.
A surgical approach that allows access to the posterior aspect of
the femoral condyle is described and the use of postero-anterior
lag screws with or without an additional buttress plate for fixation
of these difficult fractures. Cite this article:
This retrospective study evaluated the midterm clinical and radiographic outcomes of a second-generation total knee replacement system. In a multicentre consecutive series of 1512 patients, 1970 knees were treated with the PFC Sigma knee system (Depuy, Warsaw, Indiana). The patients were reviewed for functional outcome, and underwent independent radiographic evaluation at a mean follow-up of 7.3 years (5 to 10). A total of 40 knees (2%) required revision, 17 (0.9%) for infection. The incidence of osteolysis was 2.2%. The ten-year survival with revision for any cause other than infection as the endpoint was 97.2% (95% CI 95.4 to 99.1). The PFC Sigma knee system appears to provide excellent results in the medium term.
We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p <
0.05).
We evaluated two reconstruction techniques for a simulated posterolateral corner injury on ten pairs of cadaver knees. Specimens were mounted at 30° and 90° of knee flexion to record external rotation and varus movement. Instability was created by transversely sectioning the lateral collateral ligament at its midpoint and the popliteus tendon was released at the lateral femoral condyle. The left knee was randomly assigned for reconstruction using either a combined or fibula-based treatment with the right knee receiving the other. After sectioning, laxity increased in all the specimens. Each technique restored external rotatory and varus stability at both flexion angles to levels similar to the intact condition. For the fibula-based reconstruction method, varus laxity at 30° of knee flexion did not differ from the intact state, but was significantly less than after the combined method. Both the fibula-based and combined posterolateral reconstruction techniques are equally effective in restoring stability following the simulated injury.
The biomechanical function of the anteromedial
(AM) and posterolateral (PL) bundles of the anterior cruciate ligament
(ACL) remains controversial. Some studies report that the AM bundle
stabilises the knee joint in anteroposterior (AP) translation and
rotational movement (both internal and external) to the same extent
as the PL bundle. Others conclude that the PL bundle is more important
than the AM in controlling rotational movement. The objective of this randomised cohort study involving 60 patients
(39 men and 21 women) with a mean age of 32.9 years (18 to 53) was
to evaluate the function of the AM and the PL bundles of the ACL
in both AP and rotational movements of the knee joint after single-bundle
and double-bundle ACL reconstruction using a computer navigation
system. In the double-bundle group the patients were also randomised
to have the AM or the PL bundle tensioned first, with knee laxity
measured after each stage of reconstruction. All patients had isolated
complete ACL tears, and the presence of a meniscal injury was the
only supplementary pathology permitted for inclusion in the trial.
The KT-1000 arthrometer was used to apply a constant load to evaluate
the AP translation and the rolimeter was used to apply a constant
rotational force. For the single-bundle group deviation was measured
before and after ACL reconstruction. In the double-bundle group
deviation was measured for the ACL-deficient, AM- or PL-reconstructed
first conditions and for the total reconstruction. We found that the AM bundle in the double-bundle group controlled
rotation as much as the single-bundle technique, and to a greater
extent than the PL bundle in the double-bundle technique. The double-bundle
technique increases AP translation and rotational stability in internal
rotation more than the single-bundle technique.
The amount of anteroposterior laxity required for a good range of movement and knee function in a cruciate-retaining total knee replacement (TKR) continues to be debated. We undertook a retrospective study to evaluate the effects of anteroposterior laxity on the range of movement and knee function in 55 patients following the e-motion cruciate-retaining TKR with a minimum follow-up of two years. The knees were divided into stable (anteroposterior translation, ≤ 10 mm, 38 patients) and unstable (anteroposterior translation, >
10 mm, 17) groups based on the anteroposterior laxity, measured using stress radiographs. We compared the Hospital for Special Surgery (HSS) scores, the Western Ontario MacMasters University Osteoarthritis (WOMAC) index, weight-bearing flexion, non-weight-bearing flexion and the reduction of flexion under weight-bearing There were no differences between the stable and unstable groups with regard to the mean HHS and WOMAC total scores, as well as weight-bearing and non-weight-bearing flexion (p = 0.277, p = 0.082, p = 0.095 and p = 0.646, respectively). However, the stable group had a better WOMAC function score and less delta flexion than the unstable group (p = 0.011 and p = 0.005, respectively). Our results suggest that stable knees with laxity ≤ 10 mm have a good functional outcome and less reduction of flexion under weight-bearing conditions than unstable knees with laxity >
10 mm following an e-motion cruciate-retaining TKR.
We have investigated iatrogenic popliteal artery
injuries (PAI) during non arthroplasty knee surgery regarding mechanism
of injury, treatment and outcomes, and to identify successful strategies
when injury occurs. In all, 21 iatrogenic popliteal artery injuries in 21 patients
during knee surgery other than knee arthroplasty were identified
from the Swedish Vascular Registry (Swedvasc) between 1987 and 2011.
Prospective registry data were supplemented with case-records, including
long-term follow-up. In total, 13 patients suffered PAI during elective surgery
and eight during urgent surgery such as fracture fixation or tumour
resection. Nine injuries were detected intra-operatively, five within
12 to 48 hours and seven >
48 hours post-operatively (two days to
23 years). There were 19 open vascular and two endovascular surgical repairs.
Two patients died within six months of surgery. One patient required
amputation. Only six patients had a complete recovery of whom had
the vascular injury detected at time of injury and repaired by a
vascular surgeon. Patients sustaining vascular injury during elective
procedures are more likely to litigate (p = 0.029). We conclude that outcomes are poorer when there is a delay of
diagnosis and treatment, and that orthopaedic surgeons should develop
strategies to detect PAI early and ensure rapid access to vascular
surgical support. Cite this article:
There has been only one limited report dating from 1941 using dissection which has described the tibiofemoral joint between 120° and 160° of flexion despite the relevance of this arc to total knee replacement. We now provide a full description having examined one living and eight cadaver knees using MRI, dissection and previously published cryosections in one knee. In the range of flexion from 120° to 160° the flexion facet centre of the medial femoral condyle moves back 5 mm and rises up on to the posterior horn of the medial meniscus. At 160° the posterior horn is compressed in a synovial recess between the femoral cortex and the tibia. This limits flexion. The lateral femoral condyle also rolls back with the posterior horn of the lateral meniscus moving with the condyle. Both move down over the posterior tibia at 160° of flexion. Neither the events between 120° and 160° nor the anatomy at 160° could result from a continuation of the kinematics up to 120°. Therefore hyperflexion is a separate arc. The anatomical and functional features of this arc suggest that it would be difficult to design an implant for total knee replacement giving physiological movement from 0° to 160°.
In posterior stabilised total knee replacement
(TKR) a larger femoral component is sometimes selected to manage the
increased flexion gap caused by resection of the posterior cruciate
ligament. However, concerns remain regarding the adverse effect
of the increased anteroposterior dimensions of the femoral component
on the patellofemoral (PF) joint. Meanwhile, the gender-specific
femoral component has a narrower and thinner anterior flange and
is expected to reduce the PF contact force. PF contact forces were
measured at 90°, 120°, 130° and 140° of flexion using the NexGen
Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system
using Standard, Upsized and Gender femoral components during TKR.
Increasing the size of the femoral component significantly increased
mean PF forces at 120°, 130° and 140° of flexion (p = 0.005, p <
0.001 and p <
0.001, respectively). No difference was found in
contact force between the Gender and the Standard components. Among
the patients who had overhang of the Standard component, mean contact
forces with the Gender component were slightly lower than those
of the Standard component, but no statistical difference was found
at 90°, 120°, 130° or 140° of flexion (p = 0.689, 0.615, 0.253 and
0.248, respectively). Upsized femoral components would increase PF forces in deep knee
flexion. Gender-specific implants would not reduce PF forces.
The aim of this study was to examine the functional
outcome at ten years following lateral closing wedge high tibial osteotomy
for medial compartment osteoarthritis of the knee and to define
pre-operative predictors of survival and determinants of functional
outcome. 164 consecutive patients underwent high tibial osteotomy between
2000 and 2002. A total of 100 patients (100 knees) met the inclusion
criteria and 95 were available for review at ten years. Data were
collected prospectively and included patient demographics, surgical
details, long leg alignment radiographs, Western Ontario and McMaster Universities
osteoarthritis index (WOMAC) and Knee Society scores (KSS) pre-operatively
and at five and ten years follow-up. At ten years, 21 patients had been revised at a mean of five
years. Overall Kaplan–Meier survival was 87% (95% confidence interval
(CI) 81 to 94) and 79% (95% CI 71 to 87) at five and ten years,
respectively. When compared with unrevised patients, those who had
been revised had significantly lower mean pre-operative WOMAC Scores
(47 (21 to 85) This study has shown that improved survival is associated with
age <
55 years, pre-operative WOMAC scores >
45 and, a BMI <
30. In patients over 55 years of age with adequate pre-operative
functional scores, survival can be good and functional outcomes
can be significantly better than their younger counterparts. We
recommend the routine use of pre-operative functional outcome scores
to guide decision-making when considering suitability for high tibial osteotomy. Cite this article:
We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5°; 2° to 17°), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.
The role of computer-assisted surgery in maintaining the level of the joint in primary knee joint replacement (TKR) has not been well defined. We undertook a blinded randomised controlled trial comparing joint-line maintenance, functional outcomes, and quality-of-life outcomes between patients undergoing computer-assisted and conventional TKR. A total of 115 patients were randomised (computer-assisted, n = 55; conventional, n = 60). Two years post-operatively no significant correlation was found between computer-assisted and conventional surgery in terms of maintaining the joint line. Those TKRs where the joint line was depressed post-operatively improved the least in terms of functional scores. No difference was detected in terms of quality-of-life outcomes. Change in joint line was found to be related to change in alignment. Change in alignment significantly affects change in joint line and functional scores.
This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 ( The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100). This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR.
The treatment of osteochondral lesions and osteoarthritis
remains an ongoing clinical challenge in orthopaedics. This review
examines the current research in the fields of cartilage regeneration,
osteochondral defect treatment, and biological joint resurfacing, and
reports on the results of clinical and pre-clinical studies. We
also report on novel treatment strategies and discuss their potential
promise or pitfalls. Current focus involves the use of a scaffold
providing mechanical support with the addition of chondrocytes or mesenchymal
stem cells (MSCs), or the use of cell homing to differentiate the
organism’s own endogenous cell sources into cartilage. This method
is usually performed with scaffolds that have been coated with a
chemotactic agent or with structures that support the sustained
release of growth factors or other chondroinductive agents. We also
discuss unique methods and designs for cell homing and scaffold
production, and improvements in biological joint resurfacing. There
have been a number of exciting new studies and techniques developed
that aim to repair or restore osteochondral lesions and to treat
larger defects or the entire articular surface. The concept of a
biological total joint replacement appears to have much potential. Cite this article:
The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating.
Fixed flexion deformities are common in osteoarthritic
knees that are indicated for total knee arthroplasty. The lack of
full extension at the knee results in a greater force of quadriceps
contracture and energy expenditure. It also results in slower walking
velocity and abnormal gait mechanics, overloading the contralateral
limb. Residual flexion contractures after TKA have been associated
with poorer functional scores and outcomes. Although some flexion contractures may resolve with time after
surgery, a substantial percentage will become permanent. Therefore,
it is essential to correct fixed flexion deformities at the time
of TKA, and be vigilant in the post-operative course to maintain
the correction. Surgical techniques to address pre-operative flexion contractures
include: adequate bone resection, ligament releases, removal of
posterior osteophytes, and posterior capsular releases. Post-operatively,
extension can be maintained with focused physiotherapy, a specially
modified continuous passive motion machine, a contralateral heel
lift, and splinting.