This study evaluated whether obese patients who
lost weight before their total joint replacement and kept it off post-operatively
were at lower risk of surgical site infection (SSI) and re-admission
compared with those who remained the same weight. We reviewed 444 patients who underwent a total hip replacement
and 937 with a total knee replacement who lost weight pre-operatively
and sustained their weight loss after surgery. After adjustments,
patients who lost weight before a total hip replacement and kept
it off post-operatively had a 3.77 (95% confidence interval (CI)
1.59 to 8.95) greater likelihood of deep SSIs and those who lost
weight before a total knee replacement had a 1.63 (95% CI 1.16 to
2.28) greater likelihood of re-admission compared with the reference
group. These findings raise questions about the safety of weight management
before total replacement of the hip and knee joints. Cite this article:
The April 2013 Spine Roundup360 looks at: smuggling spinal implants; local bone graft and PLIF; predicting disability with slipped discs; mortality and spinal surgery; spondyloarthropathy; brachytherapy; and fibrin mesh and BMP.
To define Patient Acceptable Symptom State (PASS) thresholds
for the Oxford hip score (OHS) and Oxford knee score (OKS) at mid-term
follow-up. In a prospective multicentre cohort study, OHS and OKS were collected
at a mean follow-up of three years (1.5 to 6.0), combined with a
numeric rating scale (NRS) for satisfaction and an external validation
question assessing the patient’s willingness to undergo surgery
again. A total of 550 patients underwent total hip replacement (THR)
and 367 underwent total knee replacement (TKR).Objectives
Methods
Electronic forms of data collection have gained interest in recent
years. In orthopaedics, little is known about patient preference
regarding pen-and-paper or electronic questionnaires. We aimed to
determine whether patients undergoing total hip (THR) or total knee
replacement (TKR) prefer pen-and-paper or electronic questionnaires
and to identify variables that predict preference for electronic
questionnaires. We asked patients who participated in a multi-centre cohort study
investigating improvement in health-related quality of life (HRQoL)
after THR and TKR using pen-and-paper questionnaires, which mode
of questionnaire they preferred. Patient age, gender, highest completed
level of schooling, body mass index (BMI), comorbidities, indication
for joint replacement and pre-operative HRQoL were compared between
the groups preferring different modes of questionnaire. We then
performed logistic regression analyses to investigate which variables
independently predicted preference of electronic questionnaires.Objectives
Methods
The Oxford knee score (OKS) is a validated and
widely accepted disease-specific patient-reported outcome measure,
but there is limited evidence regarding any long-term trends in
the score. We reviewed 5600 individual OKS questionnaires (1547
patients) from a prospectively-collected knee replacement database,
to determine the trends in OKS over a ten-year period following
total knee replacement. The mean OKS pre-operatively was 19.5 (95%
confidence interval (CI) 18.8 to 20.2). The maximum post-operative
OKS was observed at two years (mean score 34.4 (95% CI 33.7 to 35.2)),
following which a gradual but significant decline was observed through
to the ten-year assessment (mean score 30.1 (95% CI 29.1 to 31.1))
(p <
0.001). A similar trend was observed for most of the individual
OKS components (p <
0.001). Kneeling ability initially improved
in the first year but was then followed by rapid deterioration (p
<
0.001). Pain severity exhibited the greatest improvement, although
residual pain was reported in over two-thirds of patients post-operatively,
and peak improvement in the night pain component did not occur until
year four. Post-operative OKS was lower for women (p <
0.001),
those aged <
60 years (p <
0.003) and those with a body mass
index >
35 kg/m2 (p <
0.014), although similar changes
in scores were observed. This information may assist surgeons in
advising patients of their expected outcomes, as well as providing
a comparative benchmark for evaluating longer-term outcomes following
knee replacement. Cite this article:
Techniques for fixation of fractures of the lateral
malleolus have remained essentially unchanged since the 1960s, but
are associated with complication rates of up to 30%. The fibular
nail is an alternative method of fixation requiring a minimal incision
and tissue dissection, and has the potential to reduce the incidence
of complications. We reviewed the results of 105 patients with unstable fractures
of the ankle that were fixed between 2002 and 2010 using the Acumed
fibular nail. The mean age of the patients was 64.8 years (22 to
95), and 80 (76%) had significant systemic medical comorbidities.
Various different configurations of locking screw were assessed
over the study period as experience was gained with the device.
Nailing without the use of locking screws gave satisfactory stability
in only 66% of cases (4 of 6). Initial locking screw constructs
rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable.
Overall, seven patients had loss of fixation of the fracture and
there were five post-operative wound infections related to the distal
fibula. This lead to the development of the current technique with
a screw across the syndesmosis in addition to a distal locking screw.
In 21 patients treated with this technique there have been no significant
complications and only one superficial wound infection. Good fracture
reduction was achieved in all of these patients. The mean physical
component Short-Form 12, Olerud and Molander score, and American Academy
of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean
of six years post-injury were 46 (28 to 61), 65 (35 to 100) and
83 (52 to 99), respectively. There have been no cases of fibular
nonunion. Nailing of the fibula using our current technique gives good
radiological and functional outcomes with minimal complications,
and should be considered in the management of patients with an unstable
ankle fracture.
We have previously described the short-term outcome of the use of reverse shoulder arthroplasty in the treatment of acute complex proximal humeral fractures in the elderly. We now report the clinical and radiological outcome of 36 fractures at a mean of 6.6 years (1 to 16). Previously, at a mean follow-up of 6 years (1 to 12) the mean Constant score was 58.5; this was reduced to 53 points with the further follow-up. A total of 23 patients (63%) had radiological evidence of loosening of the glenoid component. Nevertheless, only one patient had aseptic loosening of the baseplate at 12 years’ follow-up. The reduction in the mean Constant score with longer follow-up and the further development of scapular notching is worrying. New developments in design, bearing surfaces and surgical technique, and further follow-up, will determine whether reverse shoulder arthroplasty has a place in the management of complex proximal humeral fractures in the elderly.
We performed a meta-analysis of modern total
joint replacement (TJR) to determine the post-operative mortality and
the cause of death using different thromboprophylactic regimens
as follows: 1) no routine chemothromboprophylaxis (NRC); 2) Potent
anticoagulation (PA) (unfractionated or low-molecular-weight heparin, ximelagatran,
fondaparinux or rivaroxaban); 3) Potent anticoagulation combined
(PAC) with regional anaesthesia and/or pneumatic compression devices
(PCDs); 4) Warfarin (W); 5) Warfarin combined (WAC) with regional anaesthesia
and/or PCD; and 6) Multimodal (MM) prophylaxis, including regional
anaesthesia, PCDs and aspirin in low-risk patients. Cause of death
was classified as autopsy proven, clinically certain or unknown.
Deaths were grouped into cardiopulmonary excluding pulmonary embolism
(PE), PE, bleeding-related, gastrointestinal, central nervous system,
and others (miscellaneous). Meta-analysis based on fixed effects
or random effects models was used for pooling incidence data. In all, 70 studies were included (99 441 patients; 373 deaths).
The mortality was lowest in the MM (0.2%) and WC (0.2%) groups.
The most frequent cause of death was cardiopulmonary (47.9%), followed
by PE (25.4%) and bleeding (8.9%). The proportion of deaths due
to PE was not significantly affected by the thromboprophylaxis regimen (PA, 35.5%;
PAC, 28%; MM, 23.2%; and NRC, 16.3%). Fatal bleeding was higher
in groups relying on the use of anticoagulation (W, 33.8%; PA, 9.4%;
PAC, 10.8%) but the differences were not statistically significant. Our study demonstrated that the routine use of PA does not reduce
the overall mortality or the proportion of deaths due to PE.
This study was performed to review the safety and outcome of total shoulder replacements in patients who are ≥ 80 years of age. A total of 50 total shoulder replacements in 44 patients at a mean age of 82 years (80 to 89) were studied. Their health and shoulder status, the operation and post-operative course were analysed, including pain, movement, patient satisfaction, medical and surgical complications, radiographs, the need for revision surgery, and implant and patient survival. A total of 27 patients had an ASA classification of III or IV and medical abnormalities were common. Of the 13 shoulders with bony deficiency of the glenoid, nine required grafting. The duration of hospital stay was prolonged and blood transfusions were common. There were no peri-operative deaths. The mean follow-up was for 5.5 years (2 to 12). Pain was significantly reduced (p <
0.001) and movement improved in active elevation and both external and internal rotation (p <
0.001). Using the Neer scale for assessing outcome, 40 (80%) shoulders had an excellent or satisfactory result. There were medical or surgical complications in 17 cases. Four shoulders developed radiological evidence of loosened glenoid components, and three of these had a poor outcome. Three other shoulders required revision, two for instability. By the time of this review 39 of the patients had died from unrelated causes at a mean of 7.5 years (0.8 to 16.4) after surgery. Total shoulder replacement is a relatively effective treatment in this elderly group of patients. However, there is a requirement for more intense patient care in the peri-operative period, and non-fatal medical or surgical complications are common. Most of these elderly patients will have a comfortable functional shoulder for the rest of their lives.
We evaluated 535 consecutive primary cementless total knee replacements (TKR). The mean follow-up was 9.2 years (0.3 to 12.9) and information on implant survival was available for all patients. Patients were divided into two groups: 153 obese patients (BMI ≥ 30) and 382 non-obese (BMI <
30). A case-matched study was performed on the clinical and radiological outcome, comparing 50 knees in each group. We found significantly lower mean improvements in the clinical score (p = 0.044) and lower post-operative total clinical scores in the obese group (p = 0.041). There was no difference in the rate of radiological osteolysis or lucent lines, and no difference in alignment. Log rank test for survival showed no significant differences between the groups (p = 0.167), with a ten-year survival rate of 96.4% (95% confidence interval (CI) 92 to 99) in the obese and 98% (95% CI 96 to 99) in the non-obese. The mid-term survival of TKR in the obese and the non-obese are comparable, but obesity appears to have a negative effect on the clinical outcome. However, good results and high patient satisfaction are still to be expected, and it would seem unreasonable to deny patients a TKR simply on the basis of a BMI indicating obesity.
The aim of this study was to determine whether
obesity affects pain, surgical and functional outcomes following lumbar
spinal fusion for low back pain (LBP). A systematic literature review and meta-analysis was made of
those studies that compared the outcome of lumbar spinal fusion
for LBP in obese and non-obese patients. A total of 17 studies were
included in the meta-analysis. There was no difference in the pain
and functional outcomes. Lumbar spinal fusion in the obese patient resulted
in a statistically significantly greater intra-operative blood loss
(weighted mean difference: 54.04 ml; 95% confidence interval (CI)
15.08 to 93.00; n = 112; p = 0.007) more complications (odds ratio:
1.91; 95% CI 1.68 to 2.18; n = 43858; p <
0.001) and longer duration
of surgery (25.75 mins; 95% CI 15.61 to 35.90; n = 258; p <
0.001). Obese
patients have greater intra-operative blood loss, more complications
and longer duration of surgery but pain and functional outcome are
similar to non-obese patients. Based on these results, obesity is
not a contraindication to lumbar spinal fusion. Cite this article:
We describe three cases of fracture of the titanium JRI-Furlong hydroxyapatite-ceramic (HAC)-coated femoral component. We have examined previous case reports of failure of this stem and conclude that fracture may occur in two places, namely at the neck-shoulder junction and at the conical-distal cylindrical junction. These breakages are the result of fatigue in a metallurgically-proven normal femoral component. All the cases of failure of the femoral component have occurred in patients with a body mass index of more than 25 in whom a small component, either size 9 or 10, had been used. In patients with a body mass index above normal size 9 components should be avoided and the femoral canal should be reamed sufficiently to accept a large femoral component to ensure that there is adequate metaphyseal fixation.
Procedures performed at the incorrect anatomical site are commonly perceived as being relatively rare. However, they can be a devastating event for patients and doctors. Evidence from the United Kingdom and North America suggests that wrong-site, wrong-procedure and wrong-patient events occur more commonly than we think. Furthermore, their incidence may be increasing as NHS Trusts increase the volume and complexity of procedures undertaken in order to cope with increasing demands on the system. In previous studies from North America orthopaedic surgery has been found to be the worst-offending specialty. In this paper we review the existing literature on wrong-site surgery and analyse data from the National Patient Safety Agency and NHS Litigation Authority on 292 cases of wrong-site surgery in England and Wales. Orthopaedic surgery accounted for 87 (29.8%) of these cases. In the year 2006 to 2007, the rate of wrong-site surgery in England and Wales was highest in orthopaedic surgery, in which the estimated rate was 1:105 712 cases.
This review describes the development of arthroscopy of the hip over the past 15 years with reference to patient assessment and selection, the technique, the conditions for which it is likely to prove useful, the contraindications and complications related to the procedure and, finally, to discuss possible developments in the future.