Advertisement for orthosearch.org.uk
Results 101 - 120 of 618
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1312 - 1318
1 Oct 2014
Ibrahim MS Raja S Khan MA Haddad FS

We report the five year outcomes of a two-stage approach for infected total hip replacement. This is a single-surgeon experience at a tertiary centre where the more straightforward cases are treated using single-stage exchange. This study highlights the vital role of the multidisciplinary team in managing these cases. A total of 125 patients (51 male, 74 female) with a mean age of 68 years (42 to 78) were reviewed prospectively. Functional status was assessed using the Harris hip score (HHS). The mean HHS improved from 38 (6 to 78.5) pre-operatively to 81.2 (33 to 98) post-operatively. Staphylococcus species were isolated in 85 patients (68%). . The rate of control of infection was 96% at five years. In all, 19 patients died during the period of the study. This represented a one year mortality of 0.8% and an overall mortality of 15.2% at five years. No patients were lost to follow-up. . We report excellent control of infection in a series of complex patients and infections using a two-stage revision protocol supported by a multidisciplinary approach. The reason for the high rate of mortality in these patients is not known. Cite this article: Bone Joint J 2014;96-B:1312–18


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 440 - 444
1 Apr 2017
Lee KH Jo W Ha YC Lee YK Goodman SB Koo KH

Aims. Modular or custom-made femoral components have been preferred for total hip arthroplasty (THA) in patients with a history of Perthes’ disease because of the distortion in the anatomy of the proximal femur. However, it has not been established whether a monobloc cementless stem will fit the distorted proximal femur or whether the results of the procedure are satisfactory in this group of patients. Patients and Methods. We reviewed 68 consecutive patients who had undergone THA for childhood Perthes’ disease between June 2003 and December 2008. There were 35 men and 33 women with a mean age of 48 years (16 to 73) at the time of index arthroplasty. Their mean body mass index was 24.4 (18.3 to 32.9). Of the 68 hips, 32 were classified as Stulberg class III and 36 as class IV. The mean pre-operative shortening of the affected leg was 17.2 mm (5 to 34). The minimum follow-up was five years (mean 8.5 years; 5.2 to 10). Results. An intra-operative calcar fracture occurred in eight hips (11.8%) and was successfully treated by cerclage wiring. The mean stem version was 14.6° (-2.3 to 30; standard deviation (. sd. ) 7.3). The mean acetabular component abduction was 40.2° (23.7 to 56.0; . sd. 6.5) and the mean anteversion 28.3° (6.4 to 43.0; . sd. 7.6), respectively. The mean follow-up was 8.5 years (5.2 to 10). No dislocations occurred and no hips were revised during the course of the study. At final follow-up, the mean Harris Hip Score was 91 points (59 to 100) and the mean University of California, Los Angeles activity score was 3.2 (2 to 8). Conclusion. Monobloc cementless stems reliably restore the anatomy in Perthes’ disease at THA without the need for custom-made or modular implants. Cite this article: Bone Joint J 2017;99-B:440–444


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1669 - 1674
1 Dec 2005
Mullins MM Sood M Hashemi-Nejad A Catterall A

Avascular necrosis is a serious complication of slipped capital femoral epiphysis and is difficult to treat. The reported incidence varies from 3% to 47% of patients. The aims of treatment are to maintain the range of movement of the hip and to prevent collapse of the femoral head. At present there are no clear guidelines for the management of this condition and treatment can be difficult and unrewarding. We have used examination under anaesthesia and dynamic arthrography to investigate avascular necrosis and to determine the appropriate method of treatment. We present 20 consecutive cases of avascular necrosis in patients presenting with slipped capital femoral epiphysis and describe the results of treatment with a mean follow-up of over eight years (71 to 121 months). In patients who were suitable for joint preservation (14), we report a ten-year survivorship of the hip joint of 75% and a mean Harris hip score of 82 (44 to 98)


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1603 - 1609
1 Dec 2013
Chana R Facek M Tilley S Walter WK Zicat B Walter WL

We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years. Cite this article: Bone Joint J 2013;95-B:1603–9


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1178 - 1182
1 Sep 2011
Davis AM Wood AM Keenan ACM Brenkel IJ Ballantyne JA

Studies describing the effect of body mass index (BMI) on the outcome of total hip replacement have been inconclusive and contradictory. We examined the effect of BMI on medium-term outcome in a cohort of 1617 patients who underwent a primary total hip replacement for osteoarthritis. These patients were followed prospectively for five years with the outcomes of dislocation, revision, duration of surgery and deep and superficial infection studied, as well as collecting Harris hip scores (HHS) and Short-Form 36 (SF-36) questionnaires pre-operatively and at review. A multivariate analysis was performed to see whether BMI is an independent predictor of poor outcome. We found that patients with a BMI of ? 35 kg/m. 2. have a 4.42 times higher rate of dislocation than those with a BMI < 25 kg/m. 2. Increasing BMI is also associated with superficial infection and poorer HHS and SF-36 scores at five years. These trends remain significant even when multivariate analysis adjusts for age, gender, prosthesis, operating consultant, pre-operative HHS and SF-36, and comorbidities including diabetes mellitus, cardiac disease and osteoporosis. Despite the increased risks, the five-year outcome scores indicate that obese patients have much to gain from total hip replacement. Thus total hip replacement should not be withheld from patients solely on the grounds of an elevated BMI. However, longer-term follow-up of this cohort is required to establish whether adverse outcomes become more evident with time


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 726 - 731
1 Jun 2011
Ito H Tanino H Yamanaka Y Nakamura T Minami A Matsuno T

We report the mid- to long-term (mean 20.3 years, 10 to 32.5) results of the Chiari pelvic osteotomy in patients with pre- to advanced stage osteoarthritis in dysplastic hips. We followed 163 Japanese patients (173 hips) with a mean age at surgery of 20 years (9 to 54). Overall, 124 hips (72%) had satisfactory results, with Harris hip scores ≥ 80. Satisfactory results were seen in 105 of 134 hips with pre- or early osteoarthritis (78%) and 19 of 39 hips with advanced osteoarthritis (49%). A total of 15 hips (9%) underwent a total hip replacement (THR) with a mean interval between osteotomy and THR of 16.4 years. With conversion to THR as the endpoint, the 30-year survival rate was 85.9% (95% confidence interval 82.3 to 89.5). It was 91.8% for patients with pre- or early osteoarthritis and 43.6% for those with advanced osteoarthritis (p < 0.001). We now perform the Chiari osteotomy for patients with dysplastic hips showing poor joint congruency and who prefer a joint-conserving procedure to THR


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 28 - 32
1 Jan 2016
Hanna SA Somerville L McCalden RW Naudie DD MacDonald SJ

Aims. The purpose of this study was to compare the long-term results of primary total hip arthroplasty (THA) in young patients using either a conventional (CPE) or a highly cross-linked (HXLPE) polyethylene liner in terms of functional outcome, incidence of osteolysis, radiological wear and rate of revision. Methods. We included all patients between the ages of 45 and 65 years who, between January 2000 and December 2001, had undergone a primary THA for osteoarthritis at our hospital using a CPE or HXLPE acetabular liner and a 28 mm cobalt-chrome femoral head. . From a total of 160 patients, 158 (177 hips) were available for review (CPE 89; XLPE 88). The mean age, body mass index (BMI) and follow-up in each group were: CPE: 56.8 years (46 to 65); 30.7 kg/m. 2. (19 to 58); 13.2 years (2.1 to 14.7) and HXLPE: 55.6 years (45 to 65); BMI: 30 kg/m. 2. (18 to 51); 13.1 years (5.7 to 14.4). Results. The mean Harris hip score (HHS) at final follow-up was 89.3 for the CPE group and 90.9 for the HXLPE group (p = 0.078). Osteolysis was present around 15 acetabular (17%) and 16 femoral (18%) components in the CPE hips compared with none (0%) in the HXLPE hips. The mean radiological linear wear of the CPE liners was 0.11 mm/year compared with 0.035 mm/year for the HXLPE liners (p = 0.006). The cumulative implant survival, with revision for polyethylene wear as the endpoint, was 86% (95% confidence interval 78 to 94) in the CPE group and 100% in the HXLPE group at 13 years (numbers at risk at 13 years - CPE: 65, XLPE: 61). Discussion. This study shows that HXLPE liners are associated with significantly less osteolysis and a lower rate of revision THA than CPE liners at long-term follow-up. Take home message: The findings of this study highlight the clinical benefits of using HXLPE liners in THA and support the routine use of the material in order to improve implant longevity and to decrease the number of patients needing revision for aseptic osteolysis. . Cite this article: Bone Joint J 2016;98-B:28–32


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 324 - 329
1 Mar 2005
Back DL Dalziel R Young D Shimmin A

We describe the experience with the first consecutive 230 Birmingham hip resurfacings at our centre. At a mean follow-up of three years (25 to 52 months) survivorship was 99.14% with revision in one patient for a loose acetabular component and one death from unrelated causes. One patient developed a fracture of the femoral neck at six weeks which united unremarkably after a period of non-weight-bearing. The Harris hip score improved from a mean of 62.54 (8 to 92) to 97.74 (61 to 100). The mean flexion improved from 91.52° (25 to 140) to 110.41° (80 to 145). Most patients (97%) considered the outcome to be good or excellent. Our preliminary experience with this implant is encouraging and the results are superior to the earlier generation of resurfacings for the same length of follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1522 - 1526
1 Nov 2010
McGrory BJ McGrory CP Barbour L Barbour B

Dislocation is a common and well-studied complication after total hip replacement. However, subluxation, which we define as a clinically recognised episode of incomplete movement of the femoral head outside the acetabulum with spontaneous reduction, has not been studied previously. Out of a total of 2521 hip replacements performed over 12 years by one surgeon, 30 patients experienced subluxations which occurred in 31 arthroplasties. Data were collected prospectively with a minimum follow-up of two years. Subluxation occurred significantly more frequently after revision than after primary hip replacement, and resolved in 19 of 31 cases (61.3%). In six of the 31 hips (19.4%) the patient subsequently dislocated the affected hip, and in six hips (19.4%) intermittent subluxation continued. Four patients had a revision operation for instability, three for recurrent dislocation and one for recurrent subluxation. Clinical and radiological comparisons with a matched group of stable total hips showed no correlation with demographic or radiological parameters. Patients with subluxing hips reported significantly more concern that their hip would dislocate, more often changed their behaviour to prevent instability and had lower postoperative Harris hip scores than patients with stable replacements


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 987 - 992
1 Jul 2017
Shohat N Gilat R Shitrit R Smorgick Y Beer Y Agar G

Aims. To assess the long-term effect of distal trochanteric transfer (DTT) on the clinical and radiographic outcomes of patients with Legg-Calvé-Perthes’ disease (LCPD) following a varus derotational osteotomy (VDRO). Patients and Methods. For this single centre cross-sectional retrospective study we analysed the data of 22 patients (24 hips) with LCPD who had greater trochanteric overgrowth (GTO), following a VDRO performed in our institution between 1959 and 1983. GTO was defined as an articular trochanteric distance (ATD) of < 5 mm. We compared the radiographic and clinical outcomes of patients who underwent DTT for GTO (ten patients, ten hips) with those who did not (12 patients, 14 hips). Age at presentation was 6.9 years (4 to 10) and 8.0 years (3.2 to 12) respectively. Symptoms associated with the hip and general quality of life were assessed using the Harris hip score (HHS) and the Short Form (SF)-36 questionnaires. Results. At long-term follow-up of the DTT group, the ATD was 21.7 mm (standard deviation (. sd. ) 9.8) and the centro-trochanteric distance (CTD) was 13.8 mm (. sd. 8.3). In the control group the ATD was -0.6 mm (. sd. 7.8) and the CTD was 32.5 mm (. sd. 10.2). These differences were statistically significant (p < 0.001). The mean HHS and SF-36 scores were 68.4 (. sd. 25.0) and 62.0 (. sd. 27.7) for the DTT group and 73.2 (. sd. 24.2) and 73.3 (. sd. 21.5) for the control group, respectively. There was no statistically significant difference in the HHS (p = 0.63) or SF-36 score (p = 0.25). There were four patients who had undergone hip arthroplasty in the DTT group (40%) and one patient (7.1%) in the control group (p = 0.07). The mean age at the time of arthroplasty was 45.3 years (42.1 to 56.5) and 43.6 years respectively. Six patients in the DTT group suffered from moderate to severe osteoarthritis (Tönnis grade 2 or 3) compared with eight patients in the control group (60% versus 57.1%, p = 0.61). Conclusion. Although DTT improved the radiographic results in the long-term follow-up of patients with GTO following VDRO, there was no clinical benefit seen in the HHS, SF-36 or incidence of osteoarthritis compared with patients who had not undergone DTT. Cite this article: Bone Joint J 2017;99-B:987–92


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1463 - 1469
1 Nov 2015
Jonsson BA Kadar T Havelin LI Haugan K Espehaug B Indrekvam K Furnes O Hallan G

We report the five-year outcome of a randomised controlled trial which used radiostereometric analysis (RSA) to assess the influence of surface oxidised zirconium (OxZr, Oxinium) on polyethylene wear in vivo. A total of 120 patients, 85 women and 35 men with a mean age of 70 years (59 to 80) who were scheduled for primary cemented total hip arthroplasty were randomly allocated to four study groups. Patients were blinded to their group assignment and received either a conventional polyethylene (CPE) or a highly cross-linked (HXL) acetabular component of identical design. On the femoral side patients received a 28 mm head made of either cobalt-chromium (CoCr) or OxZr. . The proximal head penetration (wear) was measured with repeated RSA examinations over five years. Clinical outcome was measured using the Harris hip score. . There was no difference in polyethylene wear between the two head materials when used with either of the two types of acetabular component (p = 0.3 to 0.6). When comparing the two types of polyethylene there was a significant difference in favour of HXLPE, regardless of the head material used (p < 0.001). . In conclusion, we found no advantage of OxZr over CoCr in terms of polyethylene wear after five years of follow-up. Our findings do not support laboratory results which have shown a reduced rate of wear with OxZr. They do however add to the evidence on the better resistance to wear of HXLPE over CPE. Cite this article: Bone Joint J 2015;97-B:1463–9


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 424 - 429
1 Mar 2013
Madan SS Cooper AP Davies AG Fernandes JA

We present our experience of the modified Dunn procedure in combination with a Ganz surgical dislocation of the hip to treat patients with severe slipped capital femoral epiphysis (SCFE). The aim was to prospectively investigate whether this technique is safe and reproducible. We assessed the degree of reduction, functional outcome, rate of complications, radiological changes and range of movement in the hip. There were 28 patients with a mean follow-up of 38.6 months (24 to 84). The lateral slip angle was corrected by a mean of 50.9° (95% confidence interval 44.3 to 57.5). The mean modified Harris hip score at the final follow-up was 89.1 (. sd. 9.0) and the mean Non-Arthritic Hip score was 91.3 (. sd. 9.0). Two patients had proven pre-existing avascular necrosis and two developed the condition post-operatively. There were no cases of nonunion, implant failure, infection, deep-vein thrombosis or heterotopic ossification. The range of movement at final follow-up was nearly normal. This study adds to the evidence that the technique of surgical dislocation and anatomical reduction is safe and reliable in patients with SCFE. Cite this article: Bone Joint J 2013;95-B:424–9


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1050 - 1055
1 Aug 2015
Drexler M Abolghasemian M Kuzyk PR Dwyer T Kosashvili Y Backstein D Gross AE Safir O

This study reports the clinical outcome of reconstruction of deficient abductor muscles following revision total hip arthroplasty (THA), using a fresh–frozen allograft of the extensor mechanism of the knee. A retrospective analysis was conducted of 11 consecutive patients with a severe limp because of abductor deficiency which was confirmed on MRI scans. The mean age of the patients (three men and eight women) was 66.7 years (52 to 84), with a mean follow-up of 33 months (24 to 41). . Following surgery, two patients had no limp, seven had a mild limp, and two had a persistent severe limp (p = 0.004). The mean power of the abductors improved on the Medical Research Council scale from 2.15 to 3.8 (p < 0.001). Pre-operatively, all patients required a stick or walking frame; post-operatively, four patients were able to walk without an aid. Overall, nine patients had severe or moderate pain pre-operatively; ten patients had no or mild pain post-operatively. . At final review, the Harris hip score was good in five patients, fair in two and poor in four. . We conclude that using an extensor mechanism allograft is relatively effective in the treatment of chronic abductor deficiency of the hip after THA when techniques such as local tissue transfer are not possible. . Longer-term follow-up is necessary before the technique can be broadly applied. Cite this article: Bone Joint J 2015;97-B:1050–5


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 307 - 312
1 Mar 2016
Maggs JL Smeatham A Whitehouse SL Charity J Timperley AJ Gie GA

Aims. We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). Patients and Methods. A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. Results. There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. . Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. . Conclusion. Kaplan–Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. Take home message: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty. . Cite this article: Bone Joint J 2016;98-B:307–12


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1338 - 1344
1 Oct 2015
te Stroet MAJ Keurentjes JC Rijnen WHC Gardeniers JWM Verdonschot N Slooff TJJH Schreurs BW

We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). . We performed Kaplan–Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. . A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint ‘re-revision for any reason’ was 58.0% (95% confidence interval (CI) 38 to 73) and for ‘re-revision for aseptic loosening’ 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. Cite this article: Bone Joint J 2015;97-B:1338–44


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 770 - 776
1 Jun 2010
Sakai T Ohzono K Nishii T Miki H Takao M Sugano N

We compared a modular neck system with a non-modular system in a cementless anatomical total hip replacement (THR). Each group consisted of 74 hips with developmental hip dysplasia. Both groups had the same cementless acetabular component and the same articulation, which consisted of a conventional polyethylene liner and a 28 mm alumina head. The mean follow-up was 14.5 years (13 to 15), at which point there were significant differences in the mean total Harris hip score (modular/non-modular: 98.6 (64 to 100)/93.8 (68 to 100)), the mean range of abduction (32° (15° to 40°)/28 (0° to 40°)), use of a 10° elevated liner (31%/100%), the incidence of osteolysis (27%/79.7%) and the incidence of equal leg lengths (≥ 6 mm, 92%/61%). There was no disassociation or fracture of the modular neck. The modular system reduces the need for an elevated liner, thereby reducing the incidence of osteolysis. It gives a better range of movement and allows the surgeon to make an accurate adjustment of leg length


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 299 - 305
1 Mar 2008
Kim Y

This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 560 - 564
1 Apr 2005
Disch AC Matziolis G Perka C

Bone-marrow oedema can occur both in isolation and in association with necrosis of bone, but it has not been shown whether each respond to the same methods of treatment. We treated 16 patients with isolated oedema and 17, in which it was associated with necrosis of the proximal femur, with the prostacyclin derivative iloprost, which has been shown to be effective in the idiopathic form. The Harris hip score, the range of movement, the extent of the oedema as measured by MRI, pain on a visual analogue scale and patient satisfaction were recorded before and subsequent to treatment. In both groups, we were able to show a significant improvement (p < 0.001) in these observations during the period of follow-up indicating that iloprost will produce clinical improvement in both circumstances


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1309 - 1315
1 Oct 2006
Shetty N Hamer AJ Stockley I Eastell R Willkinson JM

Bisphosphonates reduce peri-prosthetic bone loss in the short term after total hip replacement but the mid- and longer term effects are not known. The aims of this randomised trial were to examine the effect of a single dose of 90 mg of pamidronate on the clinical and radiological outcome and peri-prosthetic bone mineral density in 50 patients (56 hips) over a five-year period, following total hip replacement. At five years, 37 patients (42 hips) returned for assessment. The Harris hip scores were similar in the pamidronate and placebo groups throughout the study. Also at five years, four patients, two from each group had osteolytic lesions on plain radiography. These were located around the acetabular component in three patients and in the femoral calcar in one. The femoral and acetabular peri-prosthetic bone mineral density in the pamidronate group and the control group was similar at five years. Pamidronate given as a single post-operative dose does not appear to influence the clinical outcome or prevent the development of osteolytic lesions at five years after total hip replacement


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1455 - 1458
1 Nov 2014
Amanatullah DF Rachala SR Trousdale RT Sierra RJ

Dysplasia of the hip, hypotonia, osteopenia, ligamentous laxity, and mental retardation increase the complexity of performing and managing patients with Down syndrome who require total hip replacement (THR). We identified 14 patients (six males, eight females, 21 hips) with Down syndrome and degenerative disease of the hip who underwent THR, with a minimum follow-up of two years from 1969 to 2009. In seven patients, bilateral THRs were performed while the rest had unilateral THRs. The mean clinical follow-up was 5.8 years (standard deviation (. sd. ) 4.7; 2 to 17). The mean Harris hip score was 37.9 points (. sd. 7.8) pre-operatively and increased to 89.2 (. sd. 12.3) at final follow-up (p = 1x10. -9. ). No patient suffered a post-operative dislocation. In three patients, four hips had revision THR for aseptic loosening at a mean follow-up of 7.7 years (. sd. 6.3; 3 to 17). This rate of revision THR was higher than expected. Our patients with Down syndrome benefitted clinically from THR at mid-term follow-up. Cite this article: Bone Joint J 2014;96-B:1455–8