Advertisement for orthosearch.org.uk
Results 101 - 120 of 1985
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 839 - 846
1 Jul 2008
Geerdink CH Grimm B Vencken W Heyligers IC Tonino AJ

We have compared four computer-assisted methods to measure penetration of the femoral head into the acetabular component in total hip replacement. These were the Martell Hip Analysis suite 7.14, Rogan HyperOrtho, Rogan View Pro-X and Roman v1.70. The images used for the investigation comprised 24 anteroposterior digital radiographs and 24 conventional acetate radiographs which were scanned to provide digital images. These radiographs were acquired from 24 patients with an uncemented total hip replacement with a follow-up of approximately eight years (mean 8.1; 6.3 to 9.1). Each image was measured twice by two blinded observers. The mean annual rates of penetration of the femoral head measured in the eight-year single image analysis were: Martell, 0.24 (SD 0.19); HyperOrtho, 0.12 (SD 0.08); View Pro-X, 0.12 (SD 0.06); Roman, 0.12 (SD 0.07). In paired analysis of the six-month and eight-year radiographs: Martell, 0.35 (SD 0.22); HyperOrtho, 0.15 (SD 0.13); View Pro-X, 0.11 (SD 0.06); Roman, 0.11 (SD 0.07). The intra- and inter-observer variability for the paired analysis was best for View Pro-X and Roman software, with intraclass correlations of 0.97, 0.87 and 0.96, 0.87, respectively, and worst for HyperOrtho and Martell, with intraclass correlations of 0.46, 0.13 and 0.33, 0.39, respectively. The Roman method proved the most precise and the most easy to use in clinical practice and the software is available free of charge. The Martell method showed the lowest precision, indicating a problem with its edge detection algorithm on digital images


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 922 - 930
1 Aug 2003
Ushio K Oka† M Hyon S Yura S Toguchida J Nakamura T

The use of a composite osteochondral device for simulating partial hemiarthroplasty was examined. The device was composed of a polyvinyl alcohol hydrogel and a titanium fibre mesh, acting as artificial cartilage and as porous artificial bone, respectively. The titanium fibre mesh was designed to act as an interface material, allowing firm attachment to both the polyvinyl alcohol gel (through injection moulding) and the femoral joint surface (through bony ingrowth). We implanted 22 of these devices into canine femoral heads. Histological findings from the acetabular cartilage and synovial membrane, as well as the attachment of the prosthesis to bone, were examined up until one year after operation. No marked pathological changes were found and firm attachment of the device to the underlying bone was confirmed. The main potential application for this device is for partial surface replacement of the femoral head after osteonecrosis. Other applications could include articular resurfacing and the replacement of intervertebral discs


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 68 - 72
1 Jan 1991
Ohzono K Saito M Takaoka K Ono K Saito S Nishina T Kadowaki T

We studied the natural history of nontraumatic avascular necrosis of the femoral head (ANFH) in 115 hips in 87 patients, 69 steroid-induced, 21 related to misuse of alcohol and 25 idiopathic. The average length of follow-up was over five years. Collapse occurred most often when the focus of bone necrosis occupied the weight-bearing surface of the femoral head. Flatness of the head due to subchondral fracture was an early manifestation of collapse. Classification into six types based upon the radiographic findings provided an accurate prognosis for individual cases of ANFH which is useful in planning treatment and in assessing its outcome


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1604 - 1610
1 Dec 2016
Callary SA Field JR Campbell DG

Aims. The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-in and early wear of large (36 mm and 40 mm diameter) articulations involving a second generation X3 HXLPE liner and compared our findings with previous clinical and in vitro studies of the same material. Patients and Methods. The proximal penetration of the femoral head five years post-operatively was measured for 15 patients using radiostereometric analysis (RSA). Results. The median proximal bedding-in within the first post-operative year was 0.022 mm (interquartile range (IQR) -0.050 to 0.091). The median proximal rate of wear between one and five years was -0.004 mm/year (IQR -0.021 to 0.022). The rates of proximal, medial, 2D or 3D wear between one and five years post-operatively of the X3 HXLPE liner did not increase with larger articulations compared with our previous study of 32 mm articulations. Conclusion. Although reassuring, the use of larger articulations requires continued monitoring to determine whether the low wear observed in the short-term continues to the mid- to long-term. Cite this article: Bone Joint J 2016;98-B:1604–10


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 73 - 77
1 Jan 1994
Jasty M Bragdon C Lee K Hanson A Harris W

Fifty-four cobalt-chrome alloy femoral heads were retrieved at revision surgery or at post-mortem; 23 came from uncemented, eight from hybrid and 23 from cemented hip arthroplasties. The uncemented and hybrid implants had porous coating, metal backing and modular femoral heads; with one exception none of the cemented implants had any of these. Twenty-five of the 31 heads from uncemented and hybrid arthroplasties, and 11 of the 23 heads from cemented arthroplasties showed surface damage involving more than 25% of the surface. Scanning electron microscopy revealed multidirectional fine scratches 1 micron to 10 microns in depth and width which appeared to have been made by fine, hard particles. There was a higher rate of such damage in the uncemented and hybrid arthroplasties than in the cemented implants, suggesting that the abrasive particles were mainly released from the metal, rather than from the cement or polyethylene components of the implants


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 734 - 739
1 Sep 1992
Sugano N Takaoka K Ohzono K Matsui M Saito M Saito S

We reviewed 41 hips in 40 patients at three to 11 years (average 6.3 years) after Sugioka transtrochanteric rotational osteotomy for non-traumatic avascular necrosis of the femoral head. The clinical results were excellent or good in 23 hips (56%) and the radiological success rate was 56%. Failure was due to fracture of the femoral neck, nonunion of the osteotomy, secondary collapse, or osteoarthritis. Nonunion and femoral neck fracture were more common after the use of the large screws described by Sugioka than with AO blade plates. Secondary collapse was significantly more common when less than one-third of the posterior articular surface was intact (p = 0.002). Postoperative degenerative changes were seen in cases with stage III avascular necrosis. We conclude that success depends to a large extent on the amount and stage of necrosis of the femoral head, but that careful technique and the use of AO hip plates may increase the likelihood of a satisfactory result


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 535 - 537
1 Apr 2007
Evangelista GT Fulkerson E Kummer F Di Cesare PE

During open reduction of an irreducible anterior dislocation of a total hip replacement with an Oxinium femoral head, it was observed that the head had been significantly damaged. Gross and scanning electron microscopic examination revealed cracking, gouging, and delamination of the surface. Because of the risk which this poses for damaging the polyethylene acetabular liner, it is strongly recommended that patients with this type of prosthetic head be carefully monitored after a dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 4 | Pages 777 - 791
1 Nov 1965
Catto M

1. A study of late segmental collapse in twelve femoral heads shows that it may not develop until two and a half years after the fracture. 2. Until the articular surfaces had collapsed the patients usually had no symptoms. The fractures were united and there was no obvious radiographic evidence of ischaemic necrosis. 3. There was histological evidence that the whole of the femoral heads had been necrotic at one time. The term late segmental collapse is more appropriate than late segmental necrosis. 4. The blood vessels of the ligamentum teres played little or no part in revascularisation which, when it occurred, was almost entirely across the fracture line. 5. In only one femoral head was revascularisation approaching completion and apparently continuing. In the other eleven much of the head remained necrotic and the process appeared to have halted. 6. An increase in radiological density was caused by new bone laid down on unresorbed necrotic trabeculae and was most prominent behind the line of revascularisation when the process had halted. 7. Trabecular collapse was evident within dead bone. In ten of the femoral heads it occurred in the subchondral region and in four just beyond the junction of reossified and dead bone. 8. Osteoarthritic changes occurred in the cartilage covering revascularised bone at the periphery of the head, especially when collapse was severe


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 359 - 365
1 Apr 2004
Sakano S Hasegawa Y Torii Y Kawasaki M Ishiguro N

We reviewed the outcome of curved intertrochanteric varus osteotomy in the treatment of osteonecrosis of the femoral head in 20 hips. A mean varus angulation of 31° was obtained by the osteotomy. The ratio of intact area on the weight-bearing portion increased from 19% to 61%. The mean elevation and lateral displacement of the greater trochanter were 1.2 cm and 0.5 cm, respectively. These changes in the position of the greater trochanter were very small when compared with those after conventional varus wedge osteotomy. Nonunion or delayed union was not observed. Quantitative analyses showed aggressive bone remodelling in the medial intertrochanteric region. Eighteen hips survived without collapse after a mean follow-up of 48 months. We conclude that curved varus osteotomy can be used to preserve the hip joint in patients with osteonecrosis of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 205 - 208
1 Mar 1989
Humphreys S Spencer J Tighe Cumming R

The occurrence of osteonecrosis following renal transplantation is well recognised but its pathogenesis remains unknown. We have quantified the number of empty osteocytic lacunae in the subchondral bone of femoral heads from a control group of patients, and compared these with femoral heads from a group of renal transplant recipients without evidence of overt osteonecrosis. There is a significant increase in empty osteocytic lacunae in renal transplant patients. We conclude that loss of osteocytes precedes other manifestations of osteonecrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 875 - 880
1 Nov 1995
Koo K Kim R

In a randomised trial comparing core decompression with conservative treatment we tested the hypothesis that the extent of necrosis at the initial MRI predicts the subsequent risk of collapse of the femoral head. After the initial clinical evaluation, including plain radiography and MRI, 37 hips with early-stage osteonecrosis (ON) in 33 patients were randomly assigned to a core-decompression group or a conservatively-treated group. All were followed regularly by clinical evaluation, plain radiography and MRI at intervals of three months. The extent of ON was estimated on the basis of abnormal signal intensity in the weight-bearing portion of the femoral head as determined from a combination of coronal and sagittal MRIs. The arc of the necrotic portion in the mid-coronal image (A) and that in the mid-sagittal image (B) were used to quantify the extent of necrosis by the formula: (A/180) x (B/180) x 100. There was a strong correlation between this index and the risk of collapse before and after adjustment for age, gender, stage and treatment group. We conclude that the extent of the necrotic portion ascertain by this method is a major predictor of future collapse. We propose a systematic method of determining the index of the necrotic portion which may be clinically useful in the management of early-stage ON of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1611 - 1617
1 Dec 2012
Jameson SS Baker PN Mason J Gregg PJ Brewster N Deehan DJ Reed MR

Despite excellent results, the use of cemented total hip replacement (THR) is declining. This retrospective cohort study records survival time to revision following primary cemented THR using the most common combination of components that accounted for almost a quarter of all cemented THRs, exploring risk factors independently associated with failure. All patients with osteoarthritis who had an Exeter V40/Contemporary THR (Stryker) implanted before 31 December 2010 and recorded in the National Joint Registry for England and Wales were included in the analysis. Cox’s proportional hazard models were used to analyse the extent to which risk of revision was related to patient, surgeon and implant covariates, with a significance threshold of p < 0.01. A total of 34 721 THRs were included in the study. The overall seven-year rate of revision for any reason was 1.70% (99% confidence interval (CI) 1.28 to 2.12). In the final adjusted model the risk of revision was significantly higher in THRs with the Contemporary hooded component (hazard ratio (HR) 1.88, p < 0.001) than with the flanged version, and in smaller head sizes (< 28 mm) compared with 28 mm diameter heads (HR 1.50, p = 0.005). The seven-year revision rate was 1.16% (99% CI 0.69 to 1.63) with a 28 mm diameter head and flanged component. The overall risk of revision was independent of age, gender, American Society of Anesthesiologists grade, body mass index, surgeon volume, surgical approach, brand of cement/presence of antibiotic, femoral head material (stainless steel/alumina) and stem taper size/offset. However, the risk of revision for dislocation was significantly higher with a ‘plus’ offset head (HR 2.05, p = 0.003) and a hooded acetabular component (HR 2.34, p < 0.001). In summary, we found that there were significant differences in failure between different designs of acetabular component and sizes of femoral head after adjustment for a range of covariates


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 404 - 408
1 Apr 2000
Aktas S Wheeler D Sussman MD

Cleidocranial dysplasia (CCD) is inherited as an autosomal dominant disorder characterised by failure of membranous ossification. The condition is due to a mutation of the cbfa1 gene on chromosome 6 which has a role in the development of osteoblasts from the mesenchymal cells. In their growing years, these patients have an unusual shape of the femoral head reminiscent of a ‘chef’s hat’. In order to confirm the consistency of this sign, we have reviewed the radiographs of 28 patients with CCD. All except three had this appearance. The sign was also seen in patients with coxa vara associated with a variety of other conditions. The chef’s hat sign may occur secondary to the particular mechanical environment created by coxa vara as well as abnormal cellular function in patients with CCD. Although coxa vara has some influence on the shape of the femoral head, it is not entirely responsible for its morphology since it was present in only six of the 28 patients with CCD


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 3 | Pages 442 - 461
1 Aug 1953
Trueta J Harrison MHM

1. The form and distribution of the blood vessels within the adult human femoral head are described. 2. It has been found possible to delimit the proximal femoral epiphysis in mature years by reference to arterial form alone. 3. Two morphologically different sets of vessels are described interposed between the arterioles and venules of the bone marrow. One, a true capillary bed, lies mainly within the fat marrow; the other, constituted by sinusoids, lies within the red marrow. The departure of these findings from current views is noted. 4. A capillary system is described in relationship to the calcified zone of the articular cartilage. 5. No evidence has been found in support of the common belief that the circulation within the femoral head decreases quantitatively with advancing age


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 241 - 245
1 Mar 1991
Baksi D

Sixty-one patients with 68 osteonecrotic femoral heads, at different stages of development, were treated surgically; their average age was 36 years. Necrosis followed a fracture in 43 hips and traumatic dislocation in three. It was idiopathic in 14, cortisone-induced in seven and associated with gout in one. The operation of multiple drilling, curettage of the necrotic bone and muscle pedicle bone grafting was performed in all. Cheilectomy of the superolateral part of the femoral head and adductor tenotomy were added in cases of advanced necrosis. Of the several types of muscle pedicle used, tensor fasciae latae anteriorly and quadratus femoris posteriorly were preferred. Full weight-bearing was not permitted for five to six months. The follow-up period varied from three to 12 years. Hip pain was regularly relieved and abduction and rotation of the joints were improved. Those with post-traumatic or idiopathic necrosis did better than those with cortisone-induced necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 1 | Pages 82 - 93
1 Feb 1949
Tucker FR

1. The arterial supply of the upper end of the femur has been studied in twenty-four children and twenty adults. 2. The arterial system was demonstrated by injection of radio-opaque material, with Spalteholz' method of clarification, and histological section of the neck and ligamentum teres. 3. The upper end of the femur is supplied by the nutrient artery of the shaft, the retinacular vessels of the capsule, and the foveolar artery of the ligamentum teres. 4. The retinacular vessels consist of three separate groups: postero-superior, posteroinferior, and anterior. These vessels are the chief supply to the epiphysis and femoral head at all ages. 5. The foveolar artery constitutes a small and subsidiary blood supply to the femoral epiphysis. In this series, it penetrated the cartilaginous or osseous head in 33 per cent. of young specimens and 70 per cent. of adult specimens. The foveolar vessels increase in size with age. 6. The site of the vascular pathology in various lesions of the femoral head is considered


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1309 - 1316
1 Oct 2007
Gosvig KK Jacobsen S Palm H Sonne-Holm S Magnusson E

Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip. The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (α) angle and the triangular index, a new measure of asphericity of the femoral head. In addition, the α-angle and the triangular index were assessed on the AP and lateral hip radiographs of 82 men and 82 women randomly selected from patients scheduled for total hip replacement (THR). The influence of varying femoral rotation on the α angle and the triangular index was also determined in femoral specimens under experimental conditions. From the 2803 radiographs the mean AP α-angle was 55° (30° to 100°) in men and 45° (34° to 108°) in women. Approximately 6% of men and 2% of women had cam malformation. The α-angle and triangular index were highly inter-related. Of those patients scheduled for THR, 36 men (44%) and 28 women (35%) had cam malformation identifiable on the AP radiographs. The triangular index proved to be more reliable in detecting cam malformation when the hip was held in varying degrees of rotation. The combination of the α-angle and the triangular index will allow examination of historical radiographs for epidemiological purposes in following the natural history of the cam deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 969 - 974
1 Nov 1999
Ito H Kaneda K Matsuno T

We present the long-term results of simple varus intertrochanteric osteotomy for osteonecrosis of the femoral head. We followed 26 hips in 20 patients, with a mean age at the time of surgery of 36 years, for a mean of 12.5 years. The mean varus angulation was 23°. The outcome in 19 of the hips (73%) was good or excellent; seven (27%) had a fair or poor result, with four needing some form of prosthetic arthroplasty. Simple varus intertrochanteric osteotomy is indicated, even if the extent of the capital infarct comprises more than 50% of the diameter of maximum radial distance from the circumference, provided that after operation the medial necrotic lesion measures less than two-thirds of the weight-bearing area, and the superolateral bone is normal


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 213 - 219
1 Mar 1997
Sakamoto M Shimizu K Iida S Akita T Moriya H Nawata Y

We performed a prospective study using MRI to evaluate early necrosis of the femoral head in 48 patients receiving high-dose corticosteroids for the treatment of various autoimmune-related disorders. The mean interval from the initiation of corticosteroid therapy to the first MRI examination was 2 months (0.5 to 6). MRI was repeated, and the mean period of follow-up was 31 months (24 to 69). Abnormalities were found on MRI in 31 hips (32%). The initial changes showed well-demarcated, band-like zones which were seen at a mean of 3.6 months after initiation of treatment with steroids. In 14 of these hips (45%) there was a spontaneous reduction in the size of the lesions about one year after treatment had started, but there was no further change in size with a longer follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 278 - 288
1 Mar 1986
Roberts S Weightman B Urban J Chappell D

We studied the mechanical and biochemical properties of articular cartilage from 22 osteoarthritic femoral heads obtained at operation and 97 femoral heads obtained at autopsy. Cartilage from the zenith and from the antero-inferior aspect of each head was tested both in tension and in compression. Water content, swelling ability and proteoglycan content were measured, the cartilage was examined histologically and the density of the underlying bone was assessed. Fifty-five of the autopsy specimens were defined as macroscopically normal because they exhibited no progressive fibrillation patterns on staining with Indian ink; but significant changes in water content, bone density and tensile strength related to age were seen in this group. In 20 pairs of femoral heads which were both macroscopically normal, we found, surprisingly, that cartilage from the left and right sides of the same patient was sometimes very different. Compared with the normal autopsy specimens the osteoarthritic specimens had a significantly increased swelling ability, a lower proteoglycan content and impaired mechanical properties, being both weaker in tension and softer in compression. Abnormal autopsy specimens had values intermediate between those of osteoarthritic and normal groups. Results from this abnormal group suggest that there is no primary loss of proteoglycan in early osteoarthritis