The primary aim of this study was to define the standard minimum
follow-up required to produce a reliable estimate of the rate of
re-operation after radial head arthroplasty (RHA). The secondary
objective was to define the leading reasons for re-operation. Four electronic databases, between January 2000 and March 2017
were searched. Articles reporting reasons for re-operation (Group
I) and results (Group II) after RHA were included. In Group I, a
meta-analysis was performed to obtain the standard minimum follow-up,
the mean time to re-operation and the reason for failure. In Group
II, the minimum follow-up for each study was compared with the standard
minimum follow-up.Aims
Materials and Methods
Little is known about employment following total knee arthroplasty
(TKA). This study aims to identify factors which predict return
to work following TKA in patients of working age in the United Kingdom. We prospectively assessed 289 patients (289 TKAs) aged ≤ 65 years
who underwent TKA between 2010 and 2013. There were 148 women. The
following were recorded pre-operatively: age, gender, body mass
index, social deprivation, comorbidities, indication for surgery,
work status and nature of employment, activity level as assessed by
the University of California, Los Angeles (UCLA) activity score
and Oxford Knee Score (OKS). The intention of patients to return
to work or to retire was not assessed pre-operatively. At a mean
of 3.4 years (2 to 4) post-operatively, the return to work status,
OKS, the EuroQol-5 dimensions (EQ-5D) score, UCLA activity score
and Work, Osteoarthritis and joint-Replacement (WORQ) score were
obtained. Univariate and multivariate analyses were performed.Aims
Patients &
Methods
Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions. Validated finite element models for varus and valgus malalignment by 3° and 5° were developed to evaluate the effect of malalignment on the tibial component in TKA. Maximum contact stress and contact area on a polyethylene insert, maximum contact stress on patellar button and the collateral ligament force were investigated.Objectives
Methods
The aim of this paper is to review the evidence relating to the
anatomy of the proximal femur, the geometry of the fracture and
the characteristics of implants and methods of fixation of intertrochanteric
fractures of the hip. Relevant papers were identified from appropriate clinical databases
and a narrative review was undertaken.Aims
Materials and Methods
A possible solution for the management of proximal femoral bone
loss is a modular femoral endoprosthesis (EPR). Although the outcome
of EPRs in tumour surgery has been well described, the outcome of
their use in revision hip surgery has received less attention. The
aim of this study was to describe the outcome of using EPR for non-neoplastic
indications. A retrospective review of 79 patients who underwent 80 EPRs for
non-neoplastic indications was performed, including the rates of
complication and survival and the mean Oxford Hip Scores (OHS),
at a mean of five years post-operatively. The mean age at the time
of surgery was 69 years (28 to 93) and the mean number of previous operations
on the hip was 2.4 (0 to 17). The most common indications for EPR
implantation were periprosthetic joint infection (PJI) (n = 40),
periprosthetic fracture (n = 12) and failed osteosynthesis of a
proximal femoral fracture or complex trauma (n = 11).Objectives
Methods
The optimal method of tibial component fixation remains uncertain
in total knee arthroplasty (TKA). Hydroxyapatite coatings have been
applied to improve bone ingrowth in uncemented designs, but may
only coat the directly accessible surface. As peri-apatite (PA)
is solution deposited, this may increase the coverage of the implant
surface and thereby fixation. We assessed the tibial component fixation
of uncemented PA-coated TKAs Patients were randomised to PA-coated or cemented TKAs. In 60
patients (30 in each group), radiostereometric analysis of tibial
component migration was evaluated as the primary outcome at baseline,
three months post-operatively and at one, two and five years. A
linear mixed-effects model was used to analyse the repeated measurements.Aims
Patients and Methods
The aims of this retrospective study were to report the feasibility
of using 3D-printing technology for patients with a pelvic tumour
who underwent reconstruction. A total of 35 patients underwent resection of a pelvic tumour
and reconstruction using 3D-printed endoprostheses between September
2013 and December 2015. According to Enneking’s classification of
bone defects, there were three Type I lesions, 12 Type II+III lesions,
five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV
lesions and three type I+II+III+IV lesions. A total of three patients
underwent reconstruction using an iliac prosthesis, 12 using a standard
hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic
prosthesis.Aims
Patients and Methods
To synthesise the literature and perform a meta-analysis detailing
the longitudinal recovery in the first two years following a distal
radius fracture (DRF) managed with volar plate fixation. Three databases were searched to identify relevant articles.
Following eligibility screening and quality assessment, data were
extracted and outcomes were assimilated at the post-operative time
points of interest. A state-of-the-art longitudinal mixed-effects
meta-analysis model was employed to analyse the data.Aims
Materials and Methods
To assess the accuracy of patient-specific instruments (PSIs) CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s Objectives
Methods
Anatomical total knee arthroplasty alignment
Multimodal infiltration of local anaesthetic provides effective
control of pain in patients undergoing total knee arthroplasty (TKA).
There is little information about the added benefits of posterior
capsular infiltration (PCI) using different combinations of local
anaesthetic agents. Our aim was to investigate the effectiveness
of the control of pain using multimodal infiltration with and without
infiltration of the posterior capsule of the knee. In a double-blind, randomised controlled trial of patients scheduled
for unilateral primary TKA, 86 were assigned to be treated with
multimodal infiltration with (Group I) or without (Group II) PCI.
Routine associated analgesia included the use of bupivacaine, morphine,
ketorolac and epinephrine. All patients had spinal anaesthesia and patient-controlled
analgesia (PCA) post-operatively. A visual analogue scale (VAS)
for pain and the use of morphine were recorded 24 hours post-operatively.
Side effects of the infiltration, blood loss, and length of stay
in hospital were recorded.Aims
Patients and Methods
To compare the outcomes for trochanteric fractures treated with
a sliding hip screw (SHS) or a cephalomedullary nail. A total of 400 patients with a trochanteric hip fracture were
randomised to receive a SHS or a cephalomedullary nail (Targon PFT).
All surviving patients were followed up to one year from injury.
Functional outcome was assessed by a research nurse blinded to the
implant used.Aims
Patients and Methods
The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed.Objectives
Methods
Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.Objectives
Methods
We aimed to characterise the effect of expeditious hip fracture
surgery in elderly patients within 24 hours of admission on short-term
post-operative outcomes. Patients age 65 or older that underwent surgery for closed femoral
neck and intertrochanteric hip fractures were identified from the
American College of Surgeons National Surgical Quality Improvement
Program between 2011 and 2014. Multivariable propensity-adjusted
logistic regressions were performed to determine associations between early
surgery within 24 hours and post-operative complications, controlling
for selection bias in patients undergoing early surgery based on
observable characteristics.Aims
Patients and Methods