Advertisement for orthosearch.org.uk
Results 1161 - 1180 of 2715
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 226 - 235
1 May 1960
Harrold AJ

The hypothesis provides a theoretical justification for, and re-emphasises the practical importance of, close reduction and strict immobilisation in the treatment of fractures of the neck of the femur. It does not support the view that failure of union is caused by vascular damage at the time of the original injury. Unexpected failure of union after nailing is more likely caused by unrecognised imperfection of reduction and the acknowledged deficiencies of internal fixation. Attempts to improve results by passing the sartorius muscle around the fracture (Adams 1956), or by attaching muscle or joint capsule to the proximal fragment, have failed, because such soft tissues are swept off by the acetabular rim when the hip is flexed or medially rotated. Further work is required, both on the more detailed biochemistry of haemarthroses and on the practical and wider implications of the hypothesis


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 458 - 461
1 May 1997
Rossouw DJ McElroy BJ Amis AA Emery RJH

Repair of the rotator cuff requires secure reattachment, but large chronic defects cause osteoporosis of the greater tuberosity which may then have insufficient strength to allow proper fixation of the tendon. Recently, suture anchors have been introduced, but have not been fully evaluated. We have investigated the strength of suture-to-anchor attachment, and the use of suture anchors in repairs of the rotator cuff either to the greater tuberosity or the lateral cortex of the humerus. The second method gave a significant increase in the strength of the repair (p = 0.014). The repairs were loaded cyclically and failed at low loads by cutting into bone and tendon, casting doubt on the integrity of the repair in early mobilisation after surgery. Repairs with suture anchors did not perform better than those with conventional transosseous attachment


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims

The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair.

Patients and Methods

All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair.


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 19 - 24
1 Jan 2019
Thakrar RR Horriat S Kayani B Haddad FS

Aims

Prosthetic joint infections (PJIs) of the hip and knee are associated with significant morbidity and socioeconomic burden. We undertook a systematic review of the current literature with the aim of proposing criteria for the selection of patients for a single-stage exchange arthroplasty in the management of a PJI.

Material and Methods

A comprehensive review of the current literature was performed using the OVID-MEDLINE, EMBASE, and Cochrane Library databases and the search terms: infection and knee arthroplasty OR knee revision OR hip arthroplasty OR hip revision, and one stage OR single stage OR direct exchange. All studies involving fewer than ten patients and follow-up of less than two years in the study group were excluded as also were systematic reviews, surgical techniques, and expert opinions.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 227 - 231
1 Mar 2002
van Arkel ERA de Boer HH

We describe a prospective survival analysis of 63 consecutive meniscal allografts transplanted into 57 patients. The lateral meniscus was transplanted in 34, the medial meniscus in 17, and both menisci (combined) in the same knee in six. For survival analysis we used persistent pain or mechanical damage as clinical criteria of failure. A total of 13 allografts failed (5 lateral, 7 medial, 1 medial and lateral). A significant negative correlation (p = 0.003) was found between rupture of the anterior cruciate ligament (ACL) and successful meniscal transplantation. A significant difference (p = 0.004) in the clinical results was found between lateral and medial meniscal transplants. The cumulative survival rate of the lateral, medial and combined allografts in the same knee, based on the life-table method and the Kaplan-Meier calculation, was 76%, 50% and 67%, respectively. The survival of medial meniscal allografts may improve when reconstruction of the ACL is carried out at the same time as meniscal transplantation in an ACL-deficient knee


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 796 - 801
1 Sep 1996
Kiss J Murray DW Turner-Smith AR Bithell JF Bulstrode CJ

We studied the migration of 58 cemented Hinek femoral components for total hip replacement,using roentgen stereophotogrammetric analysis over four years. The implants migrated faster during the first year than subsequently, and the pattern of migration in the second period was very different. During the first year they subsided, tilted into varus and internally rotated. After this there was slow distal migration with no change in orientation. None of the prostheses has yet failed. The early migration is probably caused by resorption of bone damaged by surgical trauma or the heat generated by the polymerisation of bone cement. Later migration may be due to creep in the bone cement or the surrounding fibrous membrane. The prosthesis which we studied allows the preservation of some of the femoral neck, and comparison with published migration studies of the Charnley stem suggests that this decreases rotation and may help to prevent loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 530 - 534
1 Jul 1996
Daly K Gill P Magnussen PA Simonis RB

We reviewed 26 consecutive men of mean age 28 years who had had wedge bone grafting and Herbert screw fixation for symptomatic established nonunion of the waist of the scaphoid. The period between injury and operation averaged 30 months (10 to 96), and 11 of the 26 patients had had previous operations, seven with bone grafts. At a mean follow-up of 14 months (6 to 42) 25 fractures (95%) had united at a median time of four months. Symptoms were improved in all patients. The outcome was not related to the time between injury and surgery or to pre-existing degenerative changes. Previous surgery carried a worse prognosis. The technique is difficult but can achieve union even when previous surgery and bone grafting have failed. The usual result is improved function and some relief of pain


Bone & Joint 360
Vol. 7, Issue 6 | Pages 1 - 1
1 Dec 2018
Ollivere B


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 116 - 118
1 Jan 2000
Best AJ Williams S Crozier A Bhatt R Gregg PJ Hui ACW

We recruited 89 patients who had hip or knee replacements to assess the performance of below-knee graded compression stockings. The pressure gradients generated by the stockings were measured and all patients had venography of the ipsilateral leg. We found that 98% of stockings failed to produce the ‘ideal’ pressure gradient (± 20%) of 18, 14 and 8 mmHg from the ankle to the knee, while 54% produced a ‘reversed gradient’ on at least one occasion during the course of the study. The overall rate of deep-venous thrombosis was 16.7%. Stockings which produced reversed gradients were associated with a significantly higher incidence of deep-venous thrombosis (p = 0.026) than those with the correct gradient (25.6% v 6.1%). This suggests that the performance of graded compression stockings can be improved if reversed pressure gradients are detected and prevented


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1330 - 1335
1 Oct 2018
Ponzio DY Weitzler L deMeireles A Esposito CI Wright TM Padgett DE

Aims

The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts.

Materials and Methods

A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces.


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 4 | Pages 629 - 643
1 Nov 1970
Gibson DA Carroll N

1. Thirteen cases of congenital pseudarthrosis of the clavicle conforming to the classical picture are presented, together with five cases of pseudarthrosis occurring for various other reasons, and nine cases of congenital pseudarthrosis that form a special group because there was a strong family history. 2. Treatment, if desired by the patient, is easy, but should be deferred until the age of four or five years. 3. The etiology remains obscure. Our embryological study does not support the theory that the clavicle normally develops from two ossification centres that may fail to coalesce. Although in thirteen of our patients there was no family history of pseudarthrosis, there was another group of nine patients who presented a strong family history, and it seems certain that in some instances congenital pseudarthrosis of the clavicle can be transmitted genetically


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 253 - 263
1 May 1960
Esteve R

1. The "frame" or traction method of reduction of congenital dislocation of the hip is, from the evidence collected in this hospital, both more effective and safer than the manipulative method of reduction. The traction method caused less frequent and less severe lesions of the femoral head than the manipulative method. 2. In cases in which closed reduction failed, open reduction was attempted; the quality of the results depended mainly on the time of operation, the best being in patients operated upon a few weeks after the initiation of the frame treatment. 3. Even with its improved results, still about 40 per cent of cases treated by the frame method showed insufficient reduction or structural changes of the femoral head. 4. Arthrography may help in indicating those cases in which open reduction is desirable


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 130 - 134
1 Jan 1999
Alfaro-Adrián J Gill HS Murray DW

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for the way in which implants function and fail. Using RSA we compared for two years the migration of the tip of the stem with that of the cement restrictor for two different designs of THR, the Exeter and Charnley Elite. We have assumed that if the cement restrictor migrates, then at least part of the cement mantle also migrates. Our results have shown that the Exeter migrates distally three times faster than the Charnley Elite and at different interfaces. With the Exeter migration was at the cement-implant interface whereas with the Charnley Elite there was migration at both the cement-bone and the cement-implant interfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 93 - 96
1 Jan 1999
Bokor DJ Conboy VB Olson C

We studied retrospectively a consecutive series of 547 shoulders in 529 patients undergoing operation for instability. In 41, the cause of instability was considered to be lateral avulsion of the capsule, including the inferior glenohumeral ligament, from the neck of the humerus, the HAGL lesion. In 35, the lesion was found at first exploration, whereas in six it was noted at revision of a previous failed procedure. In both groups, the patients were older on average than those with instability from other causes. Of the primary cases, in 33 (94.3%) the cause of the first dislocation was a violent injury; six (17.4%) had evidence of damage to the rotator cuff and/or the subscapularis. Only four (11.4%) had a Bankart lesion. In patients undergoing a primary operation in whom the cause of the first dislocation was a violent injury, who did not have a Bankart lesion and had no suggestion of multidirectional laxity, the incidence of HAGL was 39%


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 593 - 597
1 May 2001
Kamikawa K Harada Y Nagata K Moriya H

Sterilisation by gamma irradiation in the presence of air causes free radicals generated in polyethylene (PE) to react with oxygen, which could lead to loss of physical properties and reduction in fatigue strength. Tissue retrieved from failed total hip replacements often has large quantities of particulate PE and most particles associated with peri-implant osteolysis are oxidised. Consequently, an understanding of the cellular responses of oxidised PE particles may lead to clarification of the pathogenesis of osteolysis and aseptic loosening. We have used the agarose system to demonstrate the differential effects of oxidised and non-oxidised PE particles on the release of proinflammatory products such as interleukin-1β (IL-1β), IL-6, and tumour necrosis factor-α (TNF-α) from monocytes/ macrophages (M/M). Oxidised PE particles were shown to stimulate human M/M to phagocytose and to release cytokines. Oxidation may alter the surface chemistry of the particles and enhance the response to specific membrane receptors on macrophages, such as scavenger-type receptors


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 322 - 327
1 Mar 1993
Seror P

Twenty-two patients with ulnar nerve palsy at the elbow, confirmed by electromyography, were treated by a night splint which prevented flexion of the elbow beyond 60 degrees. The splint was worn all night regularly for at least six months. At a mean follow-up of 11.3 months, 17 patients had clinical and electromyographic assessment and five were contacted by telephone. There was improvement in the symptoms in every patient, including three who had failed to respond to surgical decompression. There was electromyographic improvement in 16 of the 17 patients re-examined at follow-up. The mean improvement in motor nerve conduction velocity was 6.5 m/s and in sensory nerve conduction velocity 9.5 m/s. The efficacy of this treatment suggests that nocturnal elbow flexion is an important cause of ulnar nerve lesions at the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1116 - 1120
1 Nov 2002
Sanchez-Sotelo J Morrey BF

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63). One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 695 - 700
1 Sep 1992
Poul J Bajerova J Sommernitz M Straka M Pokorny M Wong F

In this prospective study, 35,550 neonates were examined shortly after birth by a team of orthopaedic surgeons. They diagnosed 775 unstable or dislocated hips in 656 babies; there were two teratological dislocations. Treatment was first with a Frejka pillow and, if this failed to give a normal hip, a Pavlik harness at three months. Early clinical examination did not identify 21 infants who were found to have subluxation or dislocation of the hip at the three-month review. The number of missed cases declined during the study, however, reflecting the increasing experience of the examiners. One case of avascular necrosis occurred in the group treated from birth and one in the late-diagnosed group. Open reduction was necessary only in the two teratological dislocations. Experienced examiners are needed for accurate clinical diagnosis; and treatment should be started before the baby is discharged from the maternity ward


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 976 - 982
1 Nov 1998
Psychoyios V Crawford RW Murray DW O’Connor JJ

Many designs of unicompartmental knee replacement show early and mid-term failure due to polyethylene wear. We studied the wear rate of congruent polyethylene meniscal bearings retrieved from failed Oxford unicompartmental knee replacements. We examined 16 bearings, 0.8 to 12.8 years after implantation, measuring their thickness and comparing it with that of 14 unused bearings. The mean rate of penetration, which included the effects of wear at both upper and lower surfaces, was 0.036 mm per year (maximum 0.08). Bearings as thin as 3.5 mm wore no faster than thicker models, but ten with evidence of impingement had greater wear. The six bearings with no impingement showed a mean rate of penetration of 0.01 mm per year. In unicompartmental knee replacement, careful implantation of fully congruous meniscal bearings can avoid failure due to polyethylene wear


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 640 - 643
1 Jul 1991
Floman Y Kaplan L Elidan J Umansky F

We report four children aged two to nine years with traumatic tears of the transverse ligament of the atlas and atlanto-axial subluxation. This is extremely rare in this age group since trauma usually causes a skeletal rather than a ligamentous injury. The injuries resulted from falls or motor vehicle accidents, with considerable delay in diagnosis. Flexion radiographs showed atlas-dens intervals (ADI) of 6, 7, 8 and 13 mm; all four patients were treated by posterior fusion at C1-C2 after the failure of conservative treatment. In one child with quadriparesis and a fixed ADI of 13 mm, transoral anterior resection of the odontoid was performed before the fusion. Diagnosis of this traumatic lesion requires a high level of suspicion. Conservative treatment is likely to fail; surgical stabilisation is indicated