Advertisement for orthosearch.org.uk
Results 1101 - 1120 of 1964
Results per page:
Bone & Joint Research
Vol. 5, Issue 11 | Pages 577 - 585
1 Nov 2016
Hase E Sato K Yonekura D Minamikawa T Takahashi M Yasui T

Objectives

This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing.

Materials and Methods

A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1534 - 1541
1 Nov 2016
Sprowson† AP Jensen C Chambers S Parsons NR Aradhyula NM Carluke I Inman D Reed MR

Aims

A fracture of the hip is the most common serious orthopaedic injury, and surgical site infection (SSI) is one of the most significant complications, resulting in increased mortality, prolonged hospital stay and often the need for further surgery. Our aim was to determine whether high dose dual antibiotic impregnated bone cement decreases the rate of infection.

Patients and Methods

A quasi-randomised study of 848 patients with an intracapsular fracture of the hip was conducted in one large teaching hospital on two sites. All were treated with a hemiarthroplasty. A total of 448 patients received low dose single-antibiotic impregnated cement (control group) and 400 patients received high dose dual-antibiotic impregnated cement (intervention group). The primary outcome measure was deep SSI at one year after surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1376 - 1381
1 Oct 2016
Bucknall V Rutherford D MacDonald D Shalaby H McKinley J Breusch SJ

Aims

This is the first prospective study to report the pre- and post-operative patient reported outcomes and satisfaction scores following excision of interdigital Morton’s neuroma.

Patients and Methods

Between May 2006 and April 2013, we prospectively studied 99 consecutive patients (111 feet) who were to undergo excision of a Morton’s neuroma. There were 78 women and 21 men with a mean age at the time of surgery of 56 years (22 to 78). Patients completed the Manchester-Oxford Foot Questionnaire (MOXFQ), Short Form-12 (SF-12) and a supplementary patient satisfaction survey three months pre-operatively and six months post-operatively.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 16 - 21
1 Oct 2016
Jones GG Kotti M Wiik AV Collins R Brevadt MJ Strachan RK Cobb JP

Aims

To compare the gait of unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) patients with healthy controls, using a machine-learning approach.

Patients and Methods

145 participants (121 healthy controls, 12 patients with cruciate-retaining TKA, and 12 with mobile-bearing medial UKA) were recruited. The TKA and UKA patients were a minimum of 12 months post-operative, and matched for pattern and severity of arthrosis, age, and body mass index.

Participants walked on an instrumented treadmill until their maximum walking speed was reached. Temporospatial gait parameters, and vertical ground reaction force data, were captured at each speed. Oxford knee scores (OKS) were also collected. An ensemble of trees algorithm was used to analyse the data: 27 gait variables were used to train classification trees for each speed, with a binary output prediction of whether these variables were derived from a UKA or TKA patient. Healthy control gait data was then tested by the decision trees at each speed and a final classification (UKA or TKA) reached for each subject in a majority voting manner over all gait cycles and speeds. Top walking speed was also recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 125 - 130
1 Jan 2016
Clement ND Goudie EB Brooksbank AJ Chesser TJS Robinson CM

Aims

This study identifies early risk factors for symptomatic nonunion of displaced midshaft fractures of the clavicle that aid identification of an at risk group who may benefit from surgery.

Methods

We performed a retrospective study of 88 patients aged between 16 and 60 years that were managed non-operatively.


Bone & Joint Research
Vol. 5, Issue 1 | Pages 11 - 17
1 Jan 2016
Barlow JD Morrey ME Hartzler RU Arsoy D Riester S van Wijnen AJ Morrey BF Sanchez-Sotelo J Abdel MP

Aims

Animal models have been developed that allow simulation of post-traumatic joint contracture. One such model involves contracture-forming surgery followed by surgical capsular release. This model allows testing of antifibrotic agents, such as rosiglitazone.

Methods

A total of 20 rabbits underwent contracture-forming surgery. Eight weeks later, the animals underwent a surgical capsular release. Ten animals received rosiglitazone (intramuscular initially, then orally). The animals were sacrificed following 16 weeks of free cage mobilisation. The joints were tested biomechanically, and the posterior capsule was assessed histologically and via genetic microarray analysis.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims

The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation.

Patients and Methods

We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control.

The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet.


Bone & Joint Research
Vol. 5, Issue 10 | Pages 523 - 530
1 Oct 2016
Yuan Y Zhang GQ Chai W Ni M Xu C Chen JY

Objectives

Osteoarthritis (OA) is characterised by articular cartilage degradation. MicroRNAs (miRNAs) have been identified in the development of OA. The purpose of our study was to explore the functional role and underlying mechanism of miR-138-5p in interleukin-1 beta (IL-1β)-induced extracellular matrix (ECM) degradation of OA cartilage.

Materials and Methods

Human articular cartilage was obtained from patients with and without OA, and chondrocytes were isolated and stimulated by IL-1β. The expression levels of miR-138-5p in cartilage and chondrocytes were both determined. After transfection with miR-138-5p mimics, allele-specific oligonucleotide (ASO)-miR-138-5p, or their negative controls, the messenger RNA (mRNA) levels of aggrecan (ACAN), collagen type II and alpha 1 (COL2A1), the protein levels of glycosaminoglycans (GAGs), and both the mRNA and protein levels of matrix metalloproteinase (MMP)-13 were evaluated. Luciferase reporter assay, quantitative real-time polymerase chain reaction (qRT-PCR), and Western blot were performed to explore whether Forkhead Box C1 (FOCX1) was a target of miR-138-5p. Further, we co-transfected OA chondrocytes with miR-138-5p mimics and pcDNA3.1 (+)-FOXC1 and then stimulated with IL-1β to determine whether miR-138-5p-mediated IL-1β-induced cartilage matrix degradation resulted from targeting FOXC1.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1333 - 1341
1 Oct 2016
van der Voort P Valstar ER Kaptein BL Fiocco M van der Heide HJL Nelissen RGHH

Aims

The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA).

Patients and Methods

In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36).


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1175 - 1179
1 Sep 2016
Olsen M Lewis PM Morrison Z McKee MD Waddell JP Schemitsch EH

Aims

One method of femoral head preservation following avascular necrosis (AVN) is core decompression and insertion of a tantalum rod. However, there may be a high failure rate associated with this procedure. The purpose of this study was to document the clinical and radiological outcomes following total hip arthroplasty (THA) subsequent to failed tantalum rod insertion.

Patients and Methods

A total of 37 failed tantalum rods requiring total hip arthroplasty were identified from a prospective database. There were 21 hips in 21 patients (12 men and nine women, mean age 37 years, 18 to 53) meeting minimum two year clinical and radiographic follow-up whose THAs were carried out between November 2002 and April 2013 (mean time between tantalum rod implantation and conversion to a THA was 26 months, 6 to 72). These were matched by age and gender to individuals (12 men, nine women, mean age 40 years, 18 to 58) receiving THA for AVN without prior tantalum rod insertion.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 412 - 418
1 Sep 2016
Ye S Ju B Wang H Lee K

Objectives

Interleukin 18 (IL-18) is a regulatory cytokine that degrades the disc matrix. Bone morphogenetic protein-2 (BMP-2) stimulates synthesis of the disc extracellular matrix. However, the combined effects of BMP-2 and IL-18 on human intervertebral disc degeneration have not previously been reported. The aim of this study was to investigate the effects of the anabolic cytokine BMP-2 and the catabolic cytokine IL-18 on human nucleus pulposus (NP) and annulus fibrosus (AF) cells and, therefore, to identify potential therapeutic and clinical benefits of recombinant human (rh)BMP-2 in intervertebral disc degeneration.

Methods

Levels of IL-18 were measured in the blood of patients with intervertebral disc degenerative disease and in control patients. Human NP and AF cells were cultured in a NP cell medium and treated with IL-18 or IL-18 plus BMP-2. mRNA levels of target genes were measured by real-time polymerase chain reaction, and protein levels of aggrecan, type II collagen, SOX6, and matrix metalloproteinase 13 (MMP13) were assessed by western blot analysis.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1202 - 1207
1 Sep 2016
Jeyaseelan L Chandrashekar S Mulligan A Bosman HA Watson AJS

Aims

The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus.

Patients and Methods

We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction.

The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51).


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1470 - 1474
1 Nov 2015
Selvarajah E Hooper G Grabowski K Frampton C Woodfield TBF Inglis G

Polyethylene wear debris can cause osteolysis and the failure of total hip arthroplasty. We present the five-year wear rates of a highly cross-linked polyethylene (X3) bearing surface when used in conjunction with a 36 mm ceramic femoral head.

This was a prospective study of a cohort of 100 THAs in 93 patients. Pain and activity scores were measured pre- and post-operatively. Femoral head penetration was measured at two months, one year, two years and at five years using validated edge-detecting software (PolyWare Auto).

At a mean of 5.08 years (3.93 to 6.01), 85 hips in 78 patients were available for study. The mean age of these patients was 59.08 years (42 to 73, the mean age of males (n = 34) was 59.15 years, and females (n = 44) was 59.02 years). All patients had significant improvement in their functional scores (p < 0.001). The steady state two-dimensional linear wear rate was 0.109 mm/year. The steady state volumetric wear rate was 29.61 mm3/year. No significant correlation was found between rate of wear and age (p = 0.34), acetabular component size (p = 0.12) or clinical score (p = 0.74).

Our study shows low steady state wear rates at five years in X3 highly cross-linked polyethylene in conjunction with a 36 mm ceramic femoral head. The linear wear rate was almost identical to the osteolysis threshold of 0.1 mm/year recommended in the literature.

Cite this article: Bone Joint J 2015;97-B:1470–4.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims

Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component.

Patients and Methods

A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°).


Bone & Joint Research
Vol. 5, Issue 9 | Pages 403 - 411
1 Sep 2016
Mrosek EH Chung H Fitzsimmons JS O’Driscoll SW Reinholz GG Schagemann JC

Objectives

We sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling.

Materials and Methods

Adult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1240 - 1247
1 Sep 2016
Thompson W Thakar C Rolton DJ Wilson-MacDonald J Nnadi C

Aims

We undertook a prospective non-randomised radiological study to evaluate the preliminary results of using magnetically-controlled growing rods (MAGEC System, Ellipse technology) to treat children with early-onset scoliosis.

Patients and Methods

Between January 2011 and January 2015, 19 children were treated with magnetically-controlled growing rods (MCGRs) and underwent distraction at three-monthly intervals. The mean age of our cohort was 9.1 years (4 to 14) and the mean follow-up 22.4 months (5.1 to 35.2). Of the 19 children, eight underwent conversion from traditional growing rods. Whole spine radiographs were carried out pre- and post-operatively: image intensification was used during each lengthening in the outpatient department. The measurements evaluated were Cobb angle, thoracic kyphosis, proximal junctional kyphosis and spinal growth from T1 to S1.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1675 - 1682
1 Dec 2015
Strömqvist F Strömqvist B Jönsson B Gerdhem P Karlsson MK

Lumbar disc herniation (LDH) is uncommon in youth and few cases are treated surgically. Very few outcome studies exist for LDH surgery in this age group. Our aim was to explore differences in gender in pre-operative level of disability and outcome of surgery for LDH in patients aged ≤ 20 years using prospectively collected data.

From the national Swedish SweSpine register we identified 180 patients with one-year and 108 with two-year follow-up data ≤ 20 years of age, who between the years 2000 and 2010 had a primary operation for LDH.

Both male and female patients reported pronounced impairment before the operation in all patient reported outcome measures, with female patients experiencing significantly greater back pain, having greater analgesic requirements and reporting significantly inferior scores in EuroQol (EQ-5D-index), EQ-visual analogue scale, most aspects of Short Form-36 and Oswestry Disabilities Index, when compared with male patients. Surgery conferred a statistically significant improvement in all registered parameters, with few gender discrepancies. Quality of life at one year following surgery normalised in both males and females and only eight patients (4.5%) were dissatisfied with the outcome. Virtually all parameters were stable between the one- and two-year follow-up examination.

LDH surgery leads to normal health and a favourable outcome in both male and female patients aged 20 years or younger, who failed to recover after non-operative management.

Cite this article: Bone Joint J 2015;97-B:1675–82.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1074 - 1079
1 Aug 2016
Königshausen M Coulibaly MO Nicolas V Schildhauer TA Seybold D

Aims

Our aim was to investigate the outcomes of patients with a displaced fracture of the glenoid fossa who are treated conservatively. There is little information in the literature about the treatment of these rare injuries non-operatively.

Patients and Methods

We reviewed 24 patients with a mean age of 52 years (19 to 81) at a mean of 5.6 years (11 months to 18 years) after the injury.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims

Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection.

Materials and Methods

Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 166 - 172
1 Feb 2016
Langlois J Hamadouche M

Previous standards for assessing the reliability of a measurement tool have lacked consistency. We reviewed the most current American Society for Testing and Materials and International Organisation for Standardisation (ISO) recommendations, and propose an algorithm for orthopaedic surgeons. When assessing a measurement tool, conditions of the experimental set-up and clear formulae used to compile the results should be strictly reported. According to these recent guidelines, accuracy is a confusing word with an overly broad meaning and should therefore be abandoned. Depending on the experimental conditions, one should be referring to bias (when the study protocol involves accepted reference values), and repeatability (sr, r) or reproducibility (SR, R). In the absence of accepted reference values, only repeatability (sr, r) or reproducibility (SR, R) should be provided.

Take home message: Assessing the reliability of a measurement tool involves reporting bias, repeatability and/or reproducibility depending on the defined conditions, instead of precision or accuracy.

Cite this article: Bone Joint J 2016;98-B2:166–72.