Advertisement for orthosearch.org.uk
Results 1061 - 1080 of 1492
Results per page:
Bone & Joint 360
Vol. 2, Issue 5 | Pages 16 - 18
1 Oct 2013

The October 2013 Hip & Pelvis Roundup360 looks at: Young and impinging; Clothes, weather and femoral heads?; Go long, go cemented; Surgical repair of the abductors?; Aspirin for DVT prophylaxis?; Ceramic-on-polyethylene: a low-wear solution?; ALVAL and ASR™: the story continues….; Salvaging Legg-Calve-Perthes’ disease


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1000 - 1001
1 Aug 2014
Griffin XL Haddad FS


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1699 - 1705
1 Dec 2014
Boyle MJ Gao R Frampton CMA Coleman B

Our aim was to compare the one-year post-operative outcomes following retention or removal of syndesmotic screws in adult patients with a fracture of the ankle that was treated surgically. A total of 51 patients (35 males, 16 females), with a mean age of 33.5 years (16 to 62), undergoing fibular osteosynthesis and syndesmotic screw fixation, were randomly allocated to retention of the syndesmotic screw or removal at three months post-operatively. The two groups were comparable at baseline.

One year post-operatively, there was no significant difference in the mean Olerud–Molander ankle score (82.4 retention vs 86.7 removal, p = 0.367), the mean American Orthopedic Foot and Ankle Society ankle-hindfoot score (88.6 vs 90.1, p = 0.688), the mean American Academy of Orthopedic Surgeons foot and ankle score (96.3 vs 94.0, p = 0.250), the mean visual analogue pain score (1.0 vs 0.7, p = 0.237), the mean active dorsiflexion (10.2° vs 13.0°, p = 0.194) and plantar flexion (33.6° vs 31.3°, p = 0.503) of the ankle, or the mean radiological tibiofibular clear space (5.0 mm vs 5.3 mm, p = 0.276) between the two groups. A total of 19 patients (76%) in the retention group had a loose and/or broken screw one year post-operatively.

We conclude that removal of a syndesmotic screw produces no significant functional, clinical or radiological benefit in adult patients who are treated surgically for a fracture of the ankle.

Cite this article: Bone Joint J 2014;96-B:1699–1705.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1339 - 1343
1 Oct 2014
Hamilton DF Burnett R Patton JT Howie CR Simpson AHRW

Instability is the reason for revision of a primary total knee replacement (TKR) in 20% of patients. To date, the diagnosis of instability has been based on the patient’s symptoms and a subjective clinical assessment. We assessed whether a measured standardised forced leg extension could be used to quantify instability.

A total of 25 patients (11 male/14 female, mean age 70 years; 49 to 85) who were to undergo a revision TKR for instability of a primary implant were assessed with a Nottingham rig pre-operatively and then at six and 26 weeks post-operatively. Output was quantified (in revolutions per minute (rpm)) by accelerating a stationary flywheel. A control group of 183 patients (71 male/112 female, mean age 69 years) who had undergone primary TKR were evaluated for comparison.

Pre-operatively, all 25 patients with instability exhibited a distinctive pattern of reduction in ‘mid-push’ speed. The mean reduction was 55 rpm (sd 33.2). Post-operatively, no patient exhibited this pattern and the reduction in ‘mid-push’ speed was 0 rpm. The change between pre- and post-operative assessment was significant (p < 0.001). No patients in the control group exhibited this pattern at any of the intervals assessed. The between-groups difference was also significant (p < 0.001). This suggests that a quantitative diagnostic test to assess the unstable primary TKR could be developed.

Cite this article: Bone Joint J 2014;96-B:1339–43.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 29 - 31
1 Aug 2013

The August 2013 Research Roundup360 looks at: passive smoking and bone substitutes; platelet-rich plasma and osteogenesis; plantar fasciitis and platelet-rich plasma: a match made in heaven?; MRSA decolonisation decreases infection rates; gums, bisphosphonates and orthopaedics; PRAISE and partner violence; blunt impact and post-traumatic OA; and IDEAL research and implants


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1617 - 1625
1 Dec 2013
Schmitz MWJL Timmer C Rijnen WHC Gardeniers JWM Schreurs BW

Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up.

Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival.

The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group.

Cite this article: Bone Joint J 2013;95-B:1617–25.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1385 - 1391
1 Oct 2014
Grassmann JP Hakimi M Gehrmann SV Betsch M Kröpil P Wild M Windolf J Jungbluth P

The Essex-Lopresti injury (ELI) of the forearm is a rare and serious condition which is often overlooked, leading to a poor outcome.

The purpose of this retrospective case study was to establish whether early surgery can give good medium-term results.

From a group of 295 patients with a fracture of the radial head, 12 patients were diagnosed with ELI on MRI which confirmed injury to the interosseous membrane (IOM) and ligament (IOL). They were treated by reduction and temporary Kirschner (K)-wire stabilisation of the distal radioulnar joint (DRUJ). In addition, eight patients had a radial head replacement, and two a radial head reconstruction.

All patients were examined clinically and radiologically 59 months (25 to 90) after surgery when the mean Mayo Modified Wrist Score (MMWS) was 88.4 (78 to 94), the mean Mayo Elbow Performance Scores (MEPS) 86.7 (77 to 95) and the mean disabilities of arm, shoulder and hand (DASH) score 20.5 (16 to 31): all of these indicate a good outcome.

In case of a high index of suspicion for ELI in patients with a radial head fracture, we recommend the following: confirmation of IOM and IOL injury with an early MRI scan; early surgery with reduction and temporary K-wire stabilisation of the DRUJ; preservation of the radial head if at all possible or replacement if not, and functional bracing in supination. This will increase the prospect of a good result, and avoid the complications of a missed diagnosis and the difficulties of late treatment.

Cite this article: Bone Joint J 2014;96-B:1385–91.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 12 - 16
1 Oct 2014

The October 2014 Knee Roundup360 looks at: microfracture equivalent to OATS; examination better than MRI in predicting hamstrings re-injury; a second view on return to play with hamstrings injuries; dislocation risks in the Oxford Unicompartmental Knee; what about the tibia?; getting on top of lateral facet pain post TKR; readmission in TKR; patient-specific instrumentation; treating infrapatellar saphenous neuralgia; and arthroscopy in the middle-aged.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1312 - 1318
1 Oct 2014
Ibrahim MS Raja S Khan MA Haddad FS

We report the five year outcomes of a two-stage approach for infected total hip replacement. This is a single-surgeon experience at a tertiary centre where the more straightforward cases are treated using single-stage exchange. This study highlights the vital role of the multidisciplinary team in managing these cases.

A total of 125 patients (51 male, 74 female) with a mean age of 68 years (42 to 78) were reviewed prospectively. Functional status was assessed using the Harris hip score (HHS). The mean HHS improved from 38 (6 to 78.5) pre-operatively to 81.2 (33 to 98) post-operatively. Staphylococcus species were isolated in 85 patients (68%).

The rate of control of infection was 96% at five years. In all, 19 patients died during the period of the study. This represented a one year mortality of 0.8% and an overall mortality of 15.2% at five years. No patients were lost to follow-up.

We report excellent control of infection in a series of complex patients and infections using a two-stage revision protocol supported by a multidisciplinary approach. The reason for the high rate of mortality in these patients is not known.

Cite this article: Bone Joint J 2014;96-B:1312–18


Bone & Joint 360
Vol. 2, Issue 4 | Pages 27 - 29
1 Aug 2013

The August 2013 Children’s orthopaedics Roundup360 looks at: a multilevel approach to equinus gait; whether screening leads to needless intervention; salvage of subcapital slipped epiphysis; growing prostheses for children’s oncology; flexible nailing revisited; ultrasound and the pink pulseless hand; and slipping forearm fractures.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 19 - 21
1 Aug 2014

The August 2014 Wrist & Hand Roundup360 looks at: Trapeziectomy superior to arthrodesis;Tamoxifen beneficial in the short term; Semi-occlusive dressing “the bee’s knees” even with exposed bone; “Open” a relative concept in the hand and wrist; Editorial decisions pushing up standards of reporting; Ulnar variance revisited; Traditionalists are traditional; Diabetes not so bad with carpal tunnel


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1222 - 1226
1 Sep 2014
W-Dahl A Sundberg M Lidgren L Ranstam J Robertsson O

We identified a group of patients from the Swedish Arthroplasty Register who reported no relief of pain or worse pain one year after a total knee replacement (TKR). A total of two different patient-reported pain scores were used during this process. We then evaluated how the instruments used to measure pain affected the number of patients who reported no relief of pain or worse pain, and the relative effect of potential risk factors.

Between 2008 and 2010, 2883 TKRs were performed for osteoarthritis in two Swedish arthroplasty units. After applying exclusion criteria, 2123 primary TKRs (2123 patients) were included in the study. The Knee injury and Osteoarthritis Outcome Score (KOOS) and a Visual Analogue Scale (VAS) for knee pain were used to assess patients pre-operatively and one year post-operatively.

Only 50 of the 220 patients (23%) who reported no pain relief on either the KOOS pain subscale or the VAS for knee pain did so with both of these instruments. Patients who reported no pain relief on either measure tended to have less pain pre-operatively but a higher degree of anxiety. Charnley category C was a predictor for not gaining pain relief as measured on a VAS for knee pain.

The number of patients who are not relieved of pain after a TKR differs considerably depending on the instrument used to measure pain.

Cite this article: Bone Joint J 2014;96-B:1222–6.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 28 - 30
1 Aug 2014

The August 2014 Oncology Roundup360 looks at: Anaesthesic modality does not affect outcomes in tumour surgery; infection predictors in orthopaedic oncology; sarcoma depth unimportant in survival; photon/proton radiotherapy surprisingly effective in chondrosarcoma control; total humerus replacement a success!; LDH simple predictor of survival in sarcoma; Denosumab again! and Oops procedures in triplicate.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1227 - 1233
1 Sep 2014
Phillips JRA Hopwood B Arthur C Stroud R Toms AD

A small proportion of patients have persistent pain after total knee replacement (TKR). The primary aim of this study was to record the prevalence of pain after TKR at specific intervals post-operatively and to ascertain the impact of neuropathic pain. The secondary aim was to establish any predictive factors that could be used to identify patients who were likely to have high levels of pain or neuropathic pain after TKR.

A total of 96 patients were included in the study. Their mean age was 71 years (48 to 89); 54 (56%) were female. The mean follow-up was 46 months (39 to 51). Pre-operative demographic details were recorded including a Visual Analogue Score (VAS) for pain, the Hospital Anxiety and Depression score as well as the painDETECT score for neuropathic pain. Functional outcome was assessed using the Oxford Knee score.

The mean pre-operative VAS was 5.8 (1 to 10); and it improved significantly at all time periods post-operatively (p < 0.001): (from 4.5 at day three to five (1 to 10), 3.2 at six weeks (0 to 9), 2.4 at three months (0 to 7), 2.0 at six months (0 to 9), 1.7 at nine months (0 to 9), 1.5 at one year (0 to 8) and 2.0 at mean 46 months (0 to 10)). There was a high correlation (r > 0.7; p < 0.001) between the mean VAS scores for pain and the mean painDETECT scores at three months, one year and three years post-operatively. There was no correlation between the pre-operative scores and any post-operative scores at any time point.

We report the prevalence of pain and neuropathic pain at various intervals up to three years after TKR. Neuropathic pain is an underestimated problem in patients with pain after TKR. It peaks at between six weeks and three-months post-operatively. However, from these data we were unable to predict which patients are most likely to be affected.

Cite this article: Bone Joint J 2014;96-B:1227–33.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1119 - 1123
1 Aug 2014
Bali NS Harrison JO Bache CE

The aim of this study was to determine whether an osteoplasty of the femoral neck performed at the same time as an intertrochanteric Imhäuser osteotomy led to an improved functional outcome or increased morbidity. A total of 20 hips in 19 patients (12 left, 8 right, 13 male, 6 female), who underwent an Imhäuser intertrochanteric osteotomy following a slipped capital femoral epiphysis were assessed over an eight-year period. A total of 13 hips in 13 patients had an osteoplasty of the femoral neck at the same time. The remaining six patients (seven hips) had intertrochanteric osteotomy alone. The mean age was 15.3 years (13 to 20) with a mean follow-up of 57.8 months (15 to 117); 19 of the slips were severe (Southwick grade III) and one was moderate (grade II), with a mean slip angle of 65.3° (50° to 80°); 17 of the slips were stable and three unstable at initial presentation. The mean Non-Arthritic Hip Scores (NAHS) in patients who underwent osteoplasty was 91.7 (76.3 to 100) and the mean NAHS in patients who did not undergo osteoplasty was 76.6 (41.3 to 100) (p = 0.056). Two patients required a subsequent arthroplasty and neither of these patients had an osteoplasty. No hips developed osteonecrosis or chondrolysis, and there was no increase in complications related to the osteoplasty. We recommend that for patients with a slipped upper femoral epiphysis undergoing an intertrochanteric osteotomy, the addition of an osteoplasty of the femoral neck should be considered.

Cite this article: Bone Joint J 2014;96-B:1119–23.


Bone & Joint Research
Vol. 1, Issue 5 | Pages 93 - 98
1 May 2012
Gill TK Taylor AW Hill CL Phillips PJ

Objectives

To assess the sensitivity and specificity of self-reported osteoporosis compared with dual energy X-ray absorptiometry (DXA) defined osteoporosis, and to describe medication use among participants with the condition.

Methods

Data were obtained from a population-based longitudinal study and assessed for the prevalence of osteoporosis, falls, fractures and medication use. DXA scans were also undertaken.


Bone & Joint Research
Vol. 3, Issue 10 | Pages 289 - 296
1 Oct 2014
van IJsseldijk EA Harman MK Luetzner J Valstar ER Stoel BC Nelissen RGHH Kaptein BL

Introduction

Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts.

Method

Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision.


Bone & Joint Research
Vol. 2, Issue 8 | Pages 155 - 161
1 Aug 2013
Mathew SE Madhuri V

Objectives

The development of tibiofemoral angle in children has shown ethnic variations. However this data is unavailable for our population.

Methods

We measured the tibiofemoral angle (TFA) and intercondylar and intermalleolar distances in 360 children aged between two and 18 years, dividing them into six interrupted age group intervals: two to three years; five to six years; eight to nine years; 11 to 12 years; 14 to 15Â years; and 17 to 18 years. Each age group comprised 30 boys and 30 girls. Other variables recorded included standing height, sitting height, weight, thigh length, leg length and length of the lower limb.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1600 - 1609
1 Dec 2014
Matharu GS Pynsent PB Sumathi VP Mittal S Buckley CD Dunlop DJ Revell PA Revell MP

We undertook a retrospective cohort study to determine clinical outcomes following the revision of metal-on-metal (MoM) hip replacements for adverse reaction to metal debris (ARMD), and to identify predictors of time to revision and outcomes following revision. Between 1998 and 2012 a total of 64 MoM hips (mean age at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings and 18 (28%) total hip replacements) were revised for ARMD at one specialist centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision for ARMD there were 13 hips (20.3%) with post-operative complications and eight (12.5%) requiring re-revision.

The Kaplan–Meier five-year survival rate for ARMD revision was 87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding re-revisions, the median absolute Oxford hip score (OHS) following ARMD revision using the percentage method (0% best outcome and 100% worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%), which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using the modified OHS. Histopathological response did not affect time to revision for ARMD (p = 0.334) or the subsequent risk of re-revision (p = 0.879). Similarly, the presence or absence of a contralateral MoM hip bearing did not affect time to revision for ARMD (p = 0.066) or the subsequent risk of re-revision (p = 0.178).

Patients revised to MoM bearings had higher rates of re-revision (five of 16 MoM hips re-revised; p = 0.046), but those not requiring re-revision had good functional results (median absolute OHS 14.6% or 41.0/48). Short-term morbidity following revision for ARMD was comparable with previous reports. Caution should be exercised when choosing bearing surfaces for ARMD revisions.

Cite this article: Bone Joint J 2014;96-B:1600–9.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 111 - 117
1 Jun 2012
von Recum J Matschke S Jupiter JB Ring D Souer J Huber M Audigé L

Objectives

To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type.

Methods

A total of 136 patients who received either a 2.4 mm (n = 61) or 3.5 mm (n = 75) distal radius locking compression plate (LCP DR) using a volar approach were followed over two years. The main outcome measurements included motion, grip strength, pain, and the scores of Gartland and Werley, the Short-Form 36 (SF-36) and the Disabilities of the Arm, Shoulder, and Hand (DASH). Differences between the treatment groups were evaluated using regression analysis and the likelihood ratio test with significance based on the Bonferroni corrected p-value of < 0.003.