Advertisement for orthosearch.org.uk
Results 1001 - 1020 of 2522
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 614 - 619
1 Jul 1998
Baksi DP

From 1984 to 1995, 68 ankylosed elbows and 11 which were unstable after trauma were replaced in India by Baksi sloppy hinge prostheses. The mean age of the patients was 28.6 years (17 to 70) and the mean follow-up 9.6 years (2 to 13.5). Of the 68 ankylosed elbows, 59 (87%) regained a mean arc of painless movement of 88.5° (27 to 115). The mean improvement of supination was 24° and of pronation 16.5°. There were 54 good results (80%), eight fair and three poor. There were two complete failures due to infection, and one due to a broken humeral stem. Of the 11 unstable elbows, the nine with good results had a mean arc of 125° (15 to 140) of painless stable movement, with a mean improvement in supination of 26° and of pronation of 19.5°. There was one fair result and one failure due to loosening with subsequent late infection. There were significant complications in 14 cases with infection in seven and aseptic loosening in four. Patients with loosening or late removal of the prosthesis often retained reasonably stable elbow movement because periprosthetic fibrosis had connected the approximated bone ends, and muscle balance had been restored


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 377 - 381
1 May 1998
Ilchmann T Markovic L Joshi A Hardinge K Murphy J Wingstrand H

We analysed in-vivo migration and wear over a long period of all-polyethylene acetabular cups which had not been affected by mechanical loosening. The selection criteria of regular radiological follow-up, good clinical outcome (Charnley score of 5 or 6), continued walking without crutches and no radiological signs of loosening of the acetabular cups were fulfilled by 25 Charnley total hip arthroplasties. Mean migration, measured by the Nunn method, was 0.6 mm in the medial and 0.2 mm in the cranial direction. The mean yearly rate of wear was 0.05 mm and 0.04 mm, with six and two cups having no detectable wear, as measured by the Livermore and Charnley-Cupic methods, respectively. The maximal detected wear was 3.7 mm. There were no changes in the rate of wear with time. Computerised Ein Bild Röntgen Analyse (single-image radiological analysis) measurements of 20 hips indicated plastic deformation of the cups. We conclude that long-term successful cups do not migrate and have a very low rate of wear which was not affected by ageing of the polyethylene. There was no evidence that polyethylene wear alone caused mechanical loosening of the cup but high rates of wear seem to have an adverse prognostic value in terms of the long-term survival of the prosthesis


Bone & Joint Research
Vol. 8, Issue 11 | Pages 570 - 572
1 Nov 2019
Ahmed SS Haddad FS


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 759 - 764
1 Jun 2014
Tibrewal S Malagelada F Jeyaseelan L Posch F Scott G

Peri-prosthetic infection is amongst the most common causes of failure following total knee replacement (TKR). In the presence of established infection, thorough joint debridement and removal of all components is necessary following which new components may be implanted. This can be performed in one or two stages; two-stage revision with placement of an interim antibiotic-loaded spacer is regarded by many to be the standard procedure for eradication of peri-prosthetic joint infection. . We present our experience of a consecutive series of 50 single-stage revision TKRs for established deep infection performed between 1979 and 2010. There were 33 women and 17 men with a mean age at revision of 66.8 years (42 to 84) and a mean follow-up of 10.5 years (2 to 24). The mean time between the primary TKR and the revision procedure was 2.05 years (1 to 8). Only one patient required a further revision for recurrent infection, representing a success rate of 98%. Nine patients required further revision for aseptic loosening, according to microbiological testing of biopsies taken at the subsequent surgery. Three other patients developed a further septic episode but none required another revision. These results suggest that a single-stage revision can produce comparable results to a two-stage revision. Single-stage revision offers a reduction in costs as well as less morbidity and inconvenience for patients. Cite this article: Bone Joint J 2014;96-B:759–64


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1280 - 1284
1 Oct 2019
Kang JR Logli AL Tagliero AJ Sperling JW

Aims

A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty.

Patients and Methods

Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for surgery, and method of extraction were collected.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1151 - 1155
1 Nov 2000
Radl R Aigner C Hungerford M Pascher A Windhager R

We performed a retrospective analysis of the clinical and radiological outcomes of total hip replacement using an uncemented femoral component proximally coated with hydroxyapatite. Of 136 patients, 118 who had undergone 124 primary total hip replacements were available for study. Their mean age was 66.5 years (19 to 90) and the mean follow-up was 5.6 years (4.25 to 7.25). At the final follow-up the mean Harris hip score was 92 (47.7 to 100). Periprosthetic femoral fractures, which occurred in seven patients (5.6%), were treated by osteosynthesis in six and conservatively in one. We had to revise five femoral components, one because of aseptic loosening, one because of septic loosening and three because of periprosthetic fracture. At the final follow-up there were definite signs of aseptic loosening in two patients. Radiologically, proximal femoral bone loss in Gruen zones I and VI was evident in 96.8% of hips, while bone hypertrophy in zones III and V was seen in 64.7%. In 24 hips (20.2%) the mean subsidence of the stem was 3.7 mm which occurred within the first 12 postoperative weeks. This indicated poor initial stability, which might have been aggravated by early weight-bearing. The high rate of failure in our study suggests that proximal femoral bone loss affects the long-term survival of the replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1001 - 1004
1 Aug 2011
Fisher J

Bioengineering reasons for increased wear and failure of metal-on-metal (MoM) bearings in hip prostheses have been described. Low wear occurs in MoM hips when the centre of the femoral head is concentric with the centre of the acetabular component and the implants are correctly positioned. Translational or rotational malpositioning of the components can lead to the contact-patch of the femoral component being displaced to the rim of the acetabular component, resulting in a ten- to 100-fold increase in wear and metal ion levels. This may cause adverse tissue reactions, loosening of components and failure of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 128 - 136
1 Jan 2002
Böhler M Kanz F Schwarz B Steffan I Walter A Plenk H Knahr K

We revised seven alumina-blasted cementless hip prostheses (Ti-alloy stems, cp Ti threaded sockets) with low- or high-carbon Co-alloy bearings at a mean of 20.1 months after implantation because of pain and loosening. Histological examination of the retrieved periprosthetic tissues from two cases in which the implant was stable and three in which the socket was loose showed macrophages with basophilic granules containing metal and alumina wear particles and lymph-cell infiltrates. In one of the two cases of stem loosening the thickened neocapsule also contained definite lymphatic follicles and gross lymphocyte/plasma-cell infiltrates. Spectrometric determination of the concentration of elements in periprosthetic tissues from six cases was compared with that of joint capsules from five control patients undergoing primary hip surgery. In the revisions the mean concentration of implant-relevant elements was 693.85 μg/g dry tissue. In addition to Cr (15.2%), Co (4.3%), and Ti (10.3%), Al was predominant (68.1%) and all concentrations were significantly higher (p < 0.001) than those in the control tissues. The annual rates of linear wear were calculated for six implants. The mean value was 11.1 μm (heads 6.25 μm, inserts 4.82 μm). SEM/EDXA showed numerous fine scratches and deep furrows containing alumina particles in loosened sockets, and stems showed contamination with adhering or impacted alumina particles of between 2 and 50 μm in size


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 168 - 173
1 May 1980
Dobbs H

The survivorship of total hip replacements in patients operated on at the Royal National Orthopaedic Hospital has been analysed using standard actuarial methods. Between 1963 and 1972 173 metal-on-metal prostheses of various developmental designs were inserted. Between 1969 and 1972 248 prostheses of one design using a metal femoral component and plastic cup were used. The patients were surveyed retrospectively and for each the actual follow-up period was determined as well as the eventual outcome. The criterion of "survival" was that the prosthesis was still in situ and all such prostheses were regarded as "survivors", regardless of whether the patients experienced pain or loss of function. The survivorship was then determined by constructing life tables. The results indicate that for metal-on-metal prostheses the overall probability of survival was only 53 per cent after 11 years and the average annual probability of removal, irrespective of cause, was 5.5 per cent. The results were better for metal-on-plastic prostheses with figures of 88 per cent after eight years and 1.5 per cent respectively. For both prostheses the predominant reason for failure was loosening and the annual rate of removal for loosening increased as the follow-up time increased, suggesting that loosening was a wearing out process. The advantages of the survivorship method of analysis as compared with conventional methods are discussed


Aims

Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement.

Patients and Methods

A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (sd 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (sd 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 701 - 710
1 Jul 1998
Imai S Konttinen YT Jumppanen M Lindy O Čeponis A Kemppinen P Sorsa T Santavirta S Xu J Lopéz-Otín C

A foreign-body-type host response can contribute to the induction and release of collagenolytic tissue-destructive enzymes of pathogenetic significance. Our aim was to analyse collagenase-3 in two conditions with putative involvement of foreign-body reactions. Synovial membrane-like tissue samples were obtained from cases of aseptic loosening of a total hip replacement (THR) and osteoarthritis (OA). The reverse transcription polymerase chain reaction (RT-PCR) disclosed that all the samples from patients contained collagenase-3 mRNA compared with only three out of ten control samples. The identity of the RT-PCR amplification product was confirmed by nucleotide sequencing. Immunohistochemical staining showed that collagenase-3 was present in endothelial cells, macrophages and fibroblasts, including those found in the synovial lining. This finding was confirmed by avidin-biotin-peroxidase complex-alkaline phosphatase-anti-alkaline phosphatase double staining and the specificity of the staining by antigen preabsorption using recombinant human collagenase-3. Collagenase-3 was released into the extracellular space and thus found in the synovial fluid in all patient samples as shown by Western blotting. The similar extent of collagenase-3 expression in aseptic loosening and OA compared with the low expression in control synovial membrane suggests involvement of a similar, foreign-body-based pathogenetic component in both. Comparative analysis of collagenase-3 and of foreign particles indicates that paracrine factors rather than phagocytosis per se are responsible for the induction of collagenase-3. We suggest that due to its localisation and substrate specificity, collagenase-3 may play a significant pathogenetic role in accelerating tissue destruction in OA and in aseptic loosening of a THR


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1045 - 1051
1 Aug 2013
Arthroplasty Society C

The purpose of this study was twofold: first, to determine whether the five-year results of hip resurfacing arthroplasty (HRA) in Canada justified the continued use of HRA; and second, to identify whether greater refinement of patient selection was warranted. This was a retrospective cohort study that involved a review of 2773 HRAs performed between January 2001 and December 2008 at 11 Canadian centres. Cox’s proportional hazards models were used to analyse the predictors of failure of HRA. Kaplan–Meier survival analysis was performed to predict the cumulative survival rate at five years. The factors analysed included age, gender, body mass index, pre-operative hip pathology, surgeon’s experience, surgical approach, implant sizes and implant types. The most common modes of failure were also analysed. The 2773 HRAs were undertaken in 2450 patients: 2127 in men and 646 in women. The mean age at operation was 50.5 years (. sd. 8.72; 18 to 82) and mean follow-up was 3.4 years (. sd. 2.1; 2.0 to 10.1). At the last follow-up a total of 101 HRAs (3.6%) required revision. Using revision for all causes of failure as the endpoint, Kaplan–Meier survival analysis showed a cumulative survival of 96.4% (95% confidence interval (CI) 96.1 to 96.9) at five years. With regard to gender, the five-year overall survival was 97.4% in men (95% CI 97.1 to 97.7) and 93.6% in women (95% CI 92.6 to 94.6). Female gender, smaller femoral components, specific implant types and a diagnosis of childhood hip problems were associated with higher rates of failure. The most common cause of failure was fracture of the femoral neck, followed by loosening of the femoral component. The failure rates of HRA at five years justify the ongoing use of this technique in men. Female gender is an independent predictor of failure, and a higher failure rate at five years in women leads the authors to recommend this technique only in exceptional circumstances for women. . Cite this article: Bone Joint J 2013;95-B:1044–50


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 40 - 47
1 Jul 2019
Sporer S MacLean L Burger A Moric M

Aims

Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone.

Patients and Methods

A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 438 - 442
1 Apr 2004
Ritter MA Thong A Davis K Berend ME Meding JB Faris PM

We investigated the long-term changes in the Harris Hip and Knee Society scores (HSS and KSS) to determine whether they result from overall functional decline rather than actual changes in the condition of the prosthesis. The HHS for 106 total hip arthroplasties with a minimum follow-up of ten years, no medical complications after operation and no evidence of radiological loosening, and the KSS for 264 total knee arthroplasties with a minimum follow-up of 12 years and no medical complications after operation or signs of radiographical loosening were evaluated. There were statistically significant drops in the functional scoring components of the joint evaluation systems despite no loosening of the prostheses or other significant medical complications. The HHS declined at an average of 0.67 points per year from between three and ten years after operation (p < 0.0001). Contributing to this were deterioration in gait and limp (p < 0.0004), the use of support aids (p < 0.0001), the distance walked (p < 0.0001) and the ability to climb stairs (p < 0.0455). The functional component of the KSS declined significantly at an average 0.88 points per year betwen the third and 12th years (p < 0.0001). There were significant declines in every component of the functional score including the distance walked (p < 0.0001), the ability to climb stairs (p < 0.0001) and the use of support aids (p < 0.0001). The knee score component of the KSS did not decline significantly (p < 0.9750). The combination of functional and pain scores within the HHS system leads to an inaccurate decline in the entire score. The decline of HHS and Knee Society functional scores in total joint arthroplasties, in the absence of implant-related problems, suggests that deterioration in the functional capacity of ageing patients is an important factor in longitudinal studies using these scoring systems


Bone & Joint 360
Vol. 9, Issue 1 | Pages 28 - 32
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 889 - 894
1 Jul 2012
Burston BJ Barnett AJ Amirfeyz R Yates PJ Bannister GC

We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21 patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1107 - 1114
1 Sep 2019
Uy M Wang J Horner NS Bedi A Leroux T Alolabi B Khan M

Aims

The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA).

Materials and Methods

A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 432 - 438
1 May 1994
Freeman M Plante-Bordeneuve P

The vertical migration of four configurations of a proximal femoral prosthesis, followed for up to nine years, was measured on standard radiographs. The same implant was used without cement (group 1) and with cement (group 2). The migration of both groups was linear from six months onwards. The mean migration rate and the incidence of late aseptic loosening were both greater in group 1. Survival analysis of the two groups, however, showed no statistically significant difference. In both groups, hips later destined for revision migrated more rapidly from the initial postoperative period onwards, than did the remainder. A threshold migration of 1.2 mm/year during the first two years after implantation detected hips likely to fail with a specificity of 86% and a sensitivity of 78%. This 'migration test' was applied to the results in two further groups of patients in which a modified femoral prosthesis had been implanted without hydroxyapatite coating (group 3) and with hydroxyapatite coating (group 4). The test distinguished between the four groups and suggested that at least two fixation procedures should be abandoned. We conclude that vertical migration measured on standard radiographs in the first two years after implantation can be used to predict late aseptic loosening. New prosthetic configurations should be evaluated by migration measurements before their general release. Our observations support the view that one cause of late aseptic loosening is imperfect initial fixation


Bone & Joint 360
Vol. 8, Issue 4 | Pages 16 - 19
1 Aug 2019


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 261 - 267
1 Feb 2020
Tøndevold N Lastikka M Andersen T Gehrchen M Helenius I

Aims

It is uncertain whether instrumented spinal fixation in nonambulatory children with neuromuscular scoliosis should finish at L5 or be extended to the pelvis. Pelvic fixation has been shown to be associated with up to 30% complication rates, but is regarded by some as the standard for correction of deformity in these conditions. The incidence of failure when comparing the most caudal level of instrumentation, either L5 or the pelvis, using all-pedicle screw instrumentation has not previously been reported. In this retrospective study, we compared nonambulatory patients undergoing surgery at two centres: one that routinely instrumented to L5 and the other to the pelvis.

Methods

In all, 91 nonambulatory patients with neuromuscular scoliosis were included. All underwent surgery using bilateral, segmental, pedicle screw instrumentation. A total of 40 patients underwent fusion to L5 and 51 had their fixation extended to the pelvis. The two groups were assessed for differences in terms of clinical and radiological findings, as well as complications.