Magnetically controlled growing rods (MCGRs) allow non-invasive
correction of the spinal deformity in the treatment of early-onset
scoliosis. Conventional growing rod systems (CGRS) need repeated
surgical distractions: these are associated with the effect of the
‘law of diminishing returns’. The primary aim of this study was to quantify this effect in
MCGRs over sequential distractions. A total of 35 patients with a maximum follow-up of 57 months
were included in the study. There were 17 boys and 18 girls with
a mean age of 7.4 years (2 to 14). True Distraction (TD) was determined
by measuring the expansion gap on fluoroscopy. This was compared
with Intended Distraction (ID) and expressed as the ‘T/I’ ratio.
The T/I ratio and the Cobb angle were calculated at several time
points during follow-up.Aims
Patients and Methods
We wished to examine the effectiveness of tibial lengthening
using a two ring Ilizarov frame in skeletally immature patients.
This is a potentially biomechanically unstable construct which risks
the loss of axial control. We retrospectively reviewed a consecutive series of 24 boys and
26 girls, with a mean age of 8.6 years (4 to 14), who underwent
52 tibial lengthening procedures with a mean follow-up of 4.3 years
(4.0 to 16.9). Tibial alignment was measured before and after treatment
using joint orientation lines from the knee and a calculation of
the oblique plane axis.Aims
Patients and Methods
The goal of this study is to investigate the relation between indicators of osteoporosis (i.e., bone mineral density (BMD), and Cortical Index (CI)) and the complexity of a fracture of the proximal humerus as a result of a low-energy trauma. A retrospective chart review of 168 patients (mean age 67.2 years, range 51 to 88.7) with a fracture of the proximal humerus between 2007 and 2011, whose BMD was assessed at the Fracture Liaison Service with Dual Energy X-ray Absorptiometry (DXA) measurements of the hip, femoral neck (FN) and/or lumbar spine (LS), and whose CI and complexity of fracture were assessed on plain anteroposterior radiographs of the proximal humerus.Objectives
Methods
The traditional transosseus flexor hallucis longus (FHL) tendon
transfer for patients with Achilles tendinopathy requires two incisions
to harvest a long tendon graft. The use of a bio-tenodesis screw
enables a short graft to be used and is less invasive, but lacks
supporting evidence about its biomechanical behaviour. We aimed,
in this study, to compare the strength of the traditional transosseus
tendon-to-tendon fixation with tendon-to-bone fixation using a tenodesis
screw, in cyclical loading and ultimate load testing. Tendon grafts were undertaken in 24 paired lower-leg specimens
and randomly assigned in two groups using fixation with a transosseus
suture (suture group) or a tenodesis screw (screw group). The biomechanical
behaviour was evaluated using cyclical and ultimate loading tests.
The Student’s Aims
Materials and Methods
The purpose of the present study was to evaluate the impact of
intravenous tranexamic acid on the reduction of blood loss, transfusion
rate, and early post-operative clinical outcome in total shoulder
arthroplasty. A randomised, placebo-controlled trial which included 54 patients
undergoing unilateral primary stemless anatomical or stemmed reverse
total shoulder arthroplasty was undertaken. Patients received either
100 ml saline (placebo, n = 27), or 100 ml saline together with
1000 mg of tranexamic acid (TXA, n = 27) intravenously prior to
skin incision and during wound closure. Peri-operative blood loss
via an intra-articular drain was recorded and total blood loss was
calculated. The post-operative transfusion rate was documented.
Assessment of early clinical parameters included the visual analogue
scale for pain (VAS), documentation of haematoma formation and adverse events.Aims
Patients and Methods
The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue. A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.Objectives
Methods
The aim of this study was to identify risk factors for the failure
of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with
a mean age of 36.9 years (15 to 74) were treated between January
1992 and December 2012 by exchange nailing. Of which 33 (32%) were
initially open injuries. The median time from primary fixation to
exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to
9.8 months). The main outcome measures were union, number of secondary fixation
procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify
risk factors for failure to achieve union. Aims
Patients and Methods
Morton’s neuroma is common condition of the forefoot, but its
aetiology remains unclear. Our aim was to evaluate the relationship
between the width of the forefoot and the development of a Morton’s
neuroma. Between January 2013 and May 2016, a total of 84 consecutive
patients (17 men, 67 women) with a unilateral Morton’s neuroma were
enrolled into the study. The involved and uninvolved feet of each
patient were compared. A control group of patients with symptoms
from the foot, but without a neuroma who were matched for age, gender, affected
side, and web space location, were enrolled. The first to fifth
intermetatarsal distance, intermetatarsal angle and intermetatarsal
distance of involved web space on standing radiographs were assessed.Aims
Patients and Methods
If patients could recall their physical status
before total hip (THA) or knee arthroplasty (TKA) accurately it
could have valuable applications both clinically and for research.
This study evaluated the accuracy of a patient’s recollection one
year after either THA or TKA using the Oxford hip or knee scores
(OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed
the appropriate score pre-operatively were asked to complete the
score again at a mean of 12.4 months (standard deviation ( While there were no significant differences between the actual
and recalled pre-operative scores (OHS mean difference 0.8, A patient’s recollection of pre-operative pain and function is
inaccurate one year after THA or TKA. Cite this article:
An increased tibial tubercle–trochlear groove
(TT-TG) distance is related to patellar maltracking and instability.
Tibial tubercle transfer is a common treatment option for these
patients with good short-term results, although the results can
deteriorate over time owing to the progression of osteoarthritis.
We present a ten-year follow-up study of a self-centring tibial
tubercle osteotomy in 60 knees, 30 with maltracking and 30 with
patellar instability. Inclusion criteria were a TT-TG ≥ 15 mm and
symptoms for >
one year. One patient (one knee) was lost to follow-up
and one required total knee arthroplasty because of progressive
osteoarthritis. Further patellar dislocations occurred in three
knees, all in the instability group, one of which required further
surgery. The mean visual analogue scores for pain, and Lysholm and
Kujala scores improved significantly and were maintained at the
final follow-up (repeated measures, p = 0.000, intergroup differences
p = 0.449). Signs of maltracking were found in only a minority of
patients, with no difference between groups (p >
0.05). An increase
in patellofemoral osteoarthritis was seen in 16 knees (31%) with
a maximum of grade 2 on the Kellgren–Lawrence scale. The mean increase
in grades was 0.31 (0 to 2) and 0.41 (0 to 2) in the maltracking
and instability groups respectively (p = 0.2285) This self-centring tibial tubercle osteotomy provides good results
at ten years’ follow-up without inducing progressive osteoarthritis. Cite this article:
We performed a retrospective study to determine
the effect of osteoporosis on the functional outcome of osteoporotic
distal radial fractures treated with a volar locking plate. Between
2009 and 2012 a total of 90 postmenopausal women with an unstable
fracture of the distal radius treated with a volar locking plate
were studied. Changes in the radiological parameters of 51 patients
with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 ( We found that osteoporosis does not have a negative effect on
the functional outcome and additional analysis did not show a correlation
between T-score and outcome. Cite this article:
The significance of weight in the indications
for unicompartmental knee replacement (UKR) is unclear. Our hypothesis was
that weight does not affect the long-term rate of survival of UKRs. We undertook a retrospective study of 212 UKRs at a mean follow-up
of 12 years (7 to 22). The patients were distributed according to
body mass index (BMI; <
The ten-year rates of survival were similar in the two weight
subgroups (≥ 82 kg: 93.5% (95% confidence interval (CI) 66.5 to
96.3); <
82 kg: 92.5% (95% CI 82.5 to 94.1)) and also in the
two BMI subgroups (≥ 30 kg/m2: 92% (95% CI 82.5 to 95.3);
<
30 kg/m2: 94% (95% CI 78.4 to 95.9)). Multimodal
regression analysis revealed that weight plays a part in reducing
the risk of revision with a relative risk of 0.387, although this
did not reach statistical significance (p = 0.662). The results
relating weight and BMI to the clinical outcome were not statistically
significant. Thus, this study confirms that weight does not influence
the long-term rate of survival of UKR. Cite this article:
We performed a systematic review of the literature
pertaining to the functional outcomes of the surgical management
of acetabular fractures. A total of 69 articles met our inclusion
criteria, revealing that eight generic outcome instruments were
used, along with five specific instruments. The majority of studies
reported outcomes using a version of the d’Aubigne and Postel score,
which has not been validated for use in acetabular fracture. Few validated
outcome measures were reported. No psychometric testing of outcome
instruments was performed. The current assessment of outcomes in
surgery for acetabular fractures lacks scientific rigour, and does
not give reliable outcome data for either scientific comparison
or patient counselling. Take home message: The use of non-validated functional outcome
measures is a major limitation of the current literature pertaining
to surgical management of acetabular fractures; future studies should
use validated outcome measures to ensure the legitimacy of the reported
results. Cite this article:
To examine the mid-term outcome and cost utility of the BioPro
metallic hemiarthroplasty for the treatment of hallux rigidius. We reviewed 97 consecutive BioPro metallic hemiarthroplasties
performed in 80 patients for end-stage hallux rigidus, with a minimum
follow-up of five years. There were 19 men and 61 women; their mean
age was 55 years (22 to 74). No patient was lost to follow-up.Aims
Patients and Methods
The aims of our study were to provide long-term information on
the behaviour of the thoracolumbar/lumbar (TL/L) curve after thoracic
anterior correction and fusion (ASF) and to determine the impact
of ASF on pulmonary function. A total of 41 patients (four males, 37 females) with main thoracic
(MT) adolescent idiopathic scoliosis (AIS) treated with ASF were
included. Mean age at surgery was 15.2 years (11 to 27). Mean follow-up
period was 13.5 years (10 to 18).Aims
Patients and Methods
The purpose of this study was to develop an accurate, reliable and easily applicable method for determining the anatomical location of the joint line during revision knee arthroplasty. The transepicondylar width (TEW), the perpendicular distance between the medial and lateral epicondyles and the distal articular surfaces (DMAD, DLAD) and the distance between the medial and lateral epicondyles and the posterior articular surfaces (PMAD, DLAD) were measured in 40 knees from 20 formalin-fixed adult cadavers (11 male and nine female; mean age at death 56.9 years, Objectives
Methods
We assessed the effect of mental disability on
the outcome of total knee replacement (TKR) and investigated whether
mental health improves post-operatively. Outcome data were prospectively
recorded over a three-year period for 962 patients undergoing primary
TKR for osteoarthritis. Pre-operative and one year Short-Form (SF)-12 scores
and Oxford knee scores (OKS) were obtained. The mental component
of the SF-12 was stratified into four groups according to level
of mental disability (none ≥ 50, mild 40 to 49, moderate 30 to 39,
severe <
30). Patients with any degree of mental disability had
a significantly greater subjective physical disability according
to the SF-12 (p = 0.06) and OKS (p <
0.001). The improvement
in the disease-specific score (OKS) was not affected by a patient’s
mental health (p = 0.33). In contrast, patients with mental disability
had less of an improvement in their global physical health (SF-12)
(p <
0.001). However, patients with any degree of mental disability
had a significant improvement in their mental health post-operatively
(p <
0.001). Despite a similar improvement in their disease-specific scores
and improvement in their mental health, patients with mental disability
were significantly more likely to be dissatisfied with their TKR
at one year (p = 0.001). Patients with poor mental health do benefit
from improvements in their mental health and knee function after
TKR, but also have a higher rate of dissatisfaction. Cite this article:
We measured the tension in the interosseous membrane
in six cadaveric forearms using an Cite this article:
The primary aim of this study was to investigate the effect of
an enhanced recovery program (ERP) on the short-term functional
outcome after total hip arthroplasty (THA). Secondary outcomes included
its effect on rates of dislocation and mortality. Data were gathered on 1161 patients undergoing primary THA which
included 611 patients treated with traditional rehabilitation and
550 treated with an ERP. Aims
Patients and Methods
We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Metasul articulation or bearing and a titanium plasma-sprayed coating for fixation of the acetabular component. Although significantly higher blood ion levels of Cr and Co were observed at three months in the resurfaced group than in total hip replacement, no significant difference was found at two years post-operatively for Cr, 1.58 μg/L and 1.62 μg/L respectively (p = 0.819) and for Co, 0.67 μg/L and 0.94 μg/L respectively (p = 0.207). A steady state was reached at one year in the resurfaced group and after three months in the total hip replacement group. Interestingly, Ti, which is not part of the bearing surfaces with its release resulting from metal corrosion, had significantly elevated ion levels after implantation in both groups. The hip resurfacing group had significantly higher Ti levels than the total hip replacement group for all periods of follow-up. At two years the mean blood levels of Ti ions were 1.87 μg/L in hip resurfacing and and 1.30 μg/L in total hip replacement (p = 0.001). The study confirms even with different bearing diameters and clearances, hip replacement and 28 mm metal-on-metal total hip replacement produced similar Cr and Co metal ion levels in this randomised controlled trial study design, but apart from wear on bearing surfaces, passive corrosion of exposed metallic surfaces is a factor which influences ion concentrations. Ti plasma spray coating the acetabular components for hip resurfacing produces significantly higher release of Ti than Ti grit-blasted surfaces in total hip replacement.