We used a biodegradable mesh to convert an acetabular defect into a contained defect in six patients at total hip replacement. Their mean age was 61 years (46 to 69). The mean follow-up was 32 months (19 to 50). Before clinical use, the strength retention and hydrolytic in vitro degradation properties of the implants were studied in the laboratory over a two-year period. A successful clinical outcome was determined by the radiological findings and the Harris hip score. All the patients had a satisfactory outcome and no
We reviewed ten patients with metastatic carcinoma and impending pathological fractures of the subtrochanteric region of the femur who had prophylactic insertion of the Russell-Taylor reconstruction nail. There were no operative complications or long-term
Cement-in-cement revision of the femoral component represents a widely practised technique for a variety of indications in revision total hip arthroplasty. In this study, we compare the clinical and radiological outcomes of two polished tapered femoral components. From our prospectively collated database, we identified all patients undergoing cement-in-cement revision from January 2005 to January 2013 who had a minimum of two years' follow-up. All cases were performed by the senior author using either an Exeter short revision stem or the C-Stem AMT high offset No. 1 prosthesis. Patients were followed-up annually with clinical and radiological assessment.Aims
Methods
The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes. A total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m2 (21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24).Aims
Methods
1. The results of twenty-eight "hinge" arthroplasties of the knee are described. 2. Failure was most often due to breaking of the prosthesis. 3. The design of the prosthesis has been modified as a result of experience in cases of
Use of the direct anterior approach (DAA) for total hip arthroplasty (THA) has increased in recent years due to proposed benefits, including a lower risk of dislocation and improved early functional recovery. This study investigates the dislocation rate in a non-selective, consecutive cohort undergoing THA via the DAA without any exclusion or bias in patient selection based on habitus, deformity, age, sex, or fixation method. We retrospectively reviewed all patients undergoing THA via the DAA between 2011 and 2017 at our institution. Primary outcome was dislocation at minimum two-year follow-up. Patients were stratified by demographic details and risk factors for dislocation, and an in-depth analysis of dislocations was performed.Aims
Methods
We describe the use of intramedullary reconstruction nails in the treatment of 14 patients with pathological subtrochanteric fractures and coexisting metastases in the femoral shaft. After nailing, all patients were free from pain and regained mobility. They were followed up clinically and radiologically until death from the primary disease. There were no
We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of
We compared the mechanical properties of carbon fibre composite bone plates with those of stainless steel and titanium. The composite plates have less stiffness with good fatigue properties. Tissue culture and small animal implantation confirmed the biocompatibility of the material. We also present a preliminary report on the use of the carbon fibre composite plates in 40 forearm fractures. All fractures united, 67% of them showing radiological remodelling within six months. There were no refractures or
The causes of
We have carried out a retrospective review of 11 Souter-Strathclyde primary total elbow arthroplasties in ten patients with osteoarthritis, over a period of nine years. The diagnosis was primary osteoarthritis in nine elbows and post-traumatic arthritis in two. The mean follow-up was 68 months (15 to 117). Although no patient was symptomatic, radiological review revealed evidence of loosening affecting three humeral and two ulnar components, one of which subsequently failed and was revised at 97 months. There were no dislocations, deep infections or
The Stanmore hinged total knee replacement was introduced in 1969 for severe destructive arthropathy of the knee, and the results of one hundred consecutive operations are presented after an average interval of two and a half years. Insertion of the prosthesis relieved pain in 94 per cent, improved the range of movement in 67 per cent, invariably restored stability and corrected valgus or varus deformity. Gross flexion contractures were improved but not always fully corrected. Serious complications were few, though of three cases of deep infection two came to amputation and one to fibrous ankylosis. There were no
1. A series of 100 intracapsular fractures of the femoral neck treated with the Charnley compression screw is reported. 2. There were six deaths, and in patients reviewed long enough (seventy-five) there were eleven undisplaced fractures, with successful union in 8l·8 per cent, and sixty-four displaced fractures, with a union rate of 59·6 per cent. 3. If we exclude six failures of operative technique, there remain fifty-eight patients in whom the fracture was judged radiologically to have united in 65·5 per cent. 4. The Charnley compression screw is an effective method of internal fixation in such fractures, and non-union with this method is usually due to causes other than
We reviewed the clinical and radiological results of 131 patients who underwent acetabular revision for aseptic loosening with impacted bone allograft and a cemented acetabular component. The mean follow-up was 51.7 months (24 to 156). The mean post-operative Merle D’Aubigné and Postel scores were 5.7 points (4 to 6) for pain, 5.2 (3 to 6) for gait and 4.5 (2 to 6) for mobility. Radiological evaluation revealed migration greater than 5 mm in four acetabular components. Radiological failure matched clinical failure. Asymptomatic radiolucent lines were observed in 31 of 426 areas assessed (7%). Further revision was required in six patients (4.5%), this was due to infection in three and
We reviewed 351 cemented revisions of femoral stems performed for aseptic loosening. At a mean of six years after the revision operation 72.1% of the patients were pain-free and 21.4% had only mild or occasional discomfort. The latest radiographs showed definite stem loosening in 10 (2.8%) and 20 hips (5.7%) had required rerevision, only nine (2.6%) of which were for
We studied 100 patients who had undergone endoprosthetic replacement of the proximal humerus between 1976 and 1998. The outcome was assessed with regard to the survivorship of the patients, the salvaged limbs and the prostheses. Function was determined in the 47 surviving patients, of whom 30 were assessed using the Musculo-Skeletal Tumour Society (MSTS) rating scale and 38 completed the Toronto Extremity Salvage Score (TESS) questionnaire. The median age of the patients was 34 years (10 to 80). The mean follow-up period for surviving patients was nine years (2 to 20). The mean MSTS score at follow-up was 79% and the mean TESS score was 72%. The length of bone which was resected influenced the functional outcome. Abduction of the shoulder was to 45° in most patients. The overall survival was 42% at ten years and that of the limb without amputation 93%. The survival of the prostheses using
Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or
Of 135 consecutive patients admitted with subtrochanteric fractures of the femur, 104 were studied; half had internal fixation with a Zickel nail and half had a nail-plate device. Fractures treated with a Zickel nail had significantly less blood loss during operation and took less time to walk with full weight-bearing, but the incidence of technical error at operation was higher. Errors included malalignment of the cross-pin, penetration of the femoral cortex and comminution of the greater trochanter. There was
1. Two hundred and seventeen low-friction arthroplasties performed between November 1962 and April 1969 in 203 patients with failed previous operations have been analysed. 2. The technical details of operation in relation to these conversion problems have been outlined. 3. The quality of the results in relation to pain, mobility and ability to walk has been assessed before operation and one year afterwards, with small numbers at three and five years. 4. Pain was completely relieved or was minimal in 96·3 per cent of the patients, and in no case was the pain worse. 5. The total range of movement was 100 degrees or more in 98·5 per cent. No hip lost movement after conversion. 6. The failures were principally due to infection and to technical difficulties. There were no