Advertisement for orthosearch.org.uk
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Revision for aseptic stem loosening using the cemented Charnley prosthesis. A review of 351 hips



Download PDF

Abstract

We reviewed 351 cemented revisions of femoral stems performed for aseptic loosening. At a mean of six years after the revision operation 72.1% of the patients were pain-free and 21.4% had only mild or occasional discomfort. The latest radiographs showed definite stem loosening in 10 (2.8%) and 20 hips (5.7%) had required rerevision, only nine (2.6%) of which were for mechanical failure of the stem. Survivorship analysis, taking the end point as rerevision of the stem, gave 97.0% survival at eight years and 91.6% at 11 years. Excellent results both clinically and radiologically can be achieved by cemented revision of the femoral stem for aseptic loosening.

For access options please click here