Computer-assisted frameless stereotactic image guidance allows precise preoperative planning and intraoperative localisation of the image. It has been developed and tested in the laboratory. We evaluated the efficacy, clinical results and complications of placement of a pedicle screw in the
We validated the North American Spine Society (NASS) outcome-assessment instrument for the
We have evaluated two methods of surgical treatment of adolescent idiopathic double major scoliosis in 59 patients. In group 1, 31 patients were treated by fusion of the upper curve only. In group 2, 28 patients had
A group of 109 patients with unilateral low back pain for over three months were randomised to receive one of three types of injection treatment: cortisone and local anaesthetic injected into two facet joints (28), the same mixture around two facet joints (39), or physiological saline into two facet joints (42). The effect of the treatment was evaluated in relation to work attendance, pain, disability and movements of the
Assessment of bony union after anterior fusion of the
Objectives. We performed a systematic review of the literature to determine the safety and efficacy of bone morphogenetic protein (BMP) compared with bone graft when used specifically for revision spinal fusion surgery secondary to pseudarthrosis. Methods. The MEDLINE, EMBASE and Cochrane Library databases were searched using defined search terms. The primary outcome measure was spinal fusion, assessed as success or failure in accordance with radiograph, MRI or CT scan review at 24-month follow-up. The secondary outcome measure was time to fusion. Results. A total of six studies (three prospective and three retrospective) reporting on the use of BMP2 met the inclusion criteria (203 patients). Of these, four provided a comparison of BMP2 and bone graft whereas the other two solely investigated the use of BMP2. The primary outcome was seen in 92.3% (108/117) of patients following surgery with BMP2. Although none of the studies showed superiority of BMP2 to bone graft for fusion, its use was associated with a statistically quicker time to achieving fusion. BMP2 did not appear to increase the risk of complication. Conclusion. The use of BMP2 is both safe and effective within the revision setting, ideally in cases where bone graft is unavailable or undesirable. Further research is required to define its optimum role. Cite this article: Mr P. Bodalia. Effectiveness and safety of recombinant human bone morphogenetic protein-2 for adults with
Biopsies of
The optimum timing of
We treated 137 patients with symptomatic
We studied 21 former top-class competitive javelin throwers to investigate radiological and clinical symptoms in the
We have measured the dynamic movement of the
There are few reports of the treatment of
Seventy-two posterior psoas transfer operations performed in forty-four children with
We compared a group of 46 somatised patients with a control group of 41 non-somatised patients who had undergone elective surgery to the
Low
The indications for
Reports of spondylolysis in vertebrae other than those of the lower lumbar spine are rare. We report 32 patients with upper
1. The etiology and natural progress of
The midsagittal and interpedicular diameters and the trefoil shape of