Advertisement for orthosearch.org.uk
Results 81 - 100 of 115
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1119 - 1123
1 Aug 2014
Bali NS Harrison JO Bache CE

The aim of this study was to determine whether an osteoplasty of the femoral neck performed at the same time as an intertrochanteric Imhäuser osteotomy led to an improved functional outcome or increased morbidity. A total of 20 hips in 19 patients (12 left, 8 right, 13 male, 6 female), who underwent an Imhäuser intertrochanteric osteotomy following a slipped capital femoral epiphysis were assessed over an eight-year period. A total of 13 hips in 13 patients had an osteoplasty of the femoral neck at the same time. The remaining six patients (seven hips) had intertrochanteric osteotomy alone. The mean age was 15.3 years (13 to 20) with a mean follow-up of 57.8 months (15 to 117); 19 of the slips were severe (Southwick grade III) and one was moderate (grade II), with a mean slip angle of 65.3° (50° to 80°); 17 of the slips were stable and three unstable at initial presentation. The mean Non-Arthritic Hip Scores (NAHS) in patients who underwent osteoplasty was 91.7 (76.3 to 100) and the mean NAHS in patients who did not undergo osteoplasty was 76.6 (41.3 to 100) (p = 0.056). Two patients required a subsequent arthroplasty and neither of these patients had an osteoplasty. No hips developed osteonecrosis or chondrolysis, and there was no increase in complications related to the osteoplasty. We recommend that for patients with a slipped upper femoral epiphysis undergoing an intertrochanteric osteotomy, the addition of an osteoplasty of the femoral neck should be considered.

Cite this article: Bone Joint J 2014;96-B:1119–23.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer.

Cite this article: Bone Joint J 2015;97-B:1657–61.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 445 - 451
1 Apr 2013
Azegami S Kosuge D Ramachandran M

Slipped capital femoral epiphysis (SCFE) is relatively common in adolescents and results in a complex deformity of the hip that can lead to femoroacetabular impingement (FAI). FAI may be symptomatic and lead to the premature development of osteoarthritis (OA) of the hip. Current techniques for managing the deformity include arthroscopic femoral neck osteochondroplasty, an arthroscopically assisted limited anterior approach to the hip, surgical dislocation, and proximal femoral osteotomy. Although not a routine procedure to treat FAI secondary to SCFE deformity, peri-acetabular osteotomy has been successfully used to treat FAI caused by acetabular over-coverage. These procedures should be considered for patients with symptoms due to a deformity of the hip secondary to SCFE.

Cite this article: Bone Joint J 2013;95-B:445–51.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1316 - 1321
1 Oct 2015
Fukui K Trindade CAC Briggs KK Philippon MJ

The purpose of this study was to determine patient-reported outcomes of patients with mild to moderate developmental dysplasia of the hip (DDH) and femoroacetabular impingement (FAI) undergoing arthroscopy of the hip in the treatment of chondrolabral pathology. A total of 28 patients with a centre-edge angle between 15° and 19° were identified from an institutional database. Their mean age was 34 years (18 to 53), with 12 female and 16 male patients. All underwent labral treatment and concomitant correction of FAI. There were nine reoperations, with two patients requiring revision arthroscopy, two requiring periacetabular osteotomy and five needing total hip arthroplasty.

Patients who required further major surgery were more likely to be older, male, and to have more severe DDH with a larger alpha angle and decreased joint space.

At a mean follow-up of 42 months (24 to 89), the mean modified Harris hip score improved from 59 (20 to 98) to 82 (45 to 100; p < 0.001). The mean Western Ontario and McMaster Universities Osteoarthritis Index score improved from 30 (1 to 61) to 16 (0 to 43; p < 0.001). Median patient satisfaction was 9.0/10 (1 to 10). Patients reported excellent improvement in function following arthroscopy of the hip.

This study shows that with proper patient selection, arthroscopy of the hip can be successful in the young patient with mild to moderate DDH and FAI.

Cite this article: Bone Joint J 2015;97-B:1316–21.


The repair of chondral lesions associated with femoroacetabular impingement requires specific treatment in addition to that of the impingement. In this single-centre retrospective analysis of a consecutive series of patients we compared treatment with microfracture (MFx) with a technique of enhanced microfracture autologous matrix-induced chondrogenesis (AMIC).

Acetabular grade III and IV chondral lesions measuring between 2 cm2 and 8 cm2 in 147 patients were treated by MFx in 77 and AMIC in 70. The outcome was assessed using the modified Harris hip score at six months and one, two, three, four and five years post-operatively. The outcome in both groups was significantly improved at six months and one year post-operatively. During the subsequent four years the outcome in the MFx group slowly deteriorated, whereas that in the AMIC group remained stable. Six patients in the MFx group subsequently required total hip arthroplasty, compared with none in the AMIC group

We conclude that the short-term clinical outcome improves in patients with acetabular chondral damage following both MFx and AMIC. However, the AMIC group had better and more durable improvement, particularly in patients with large (≥ 4 cm2) lesions.

Cite this article: Bone Joint J 2015; 97-B:628–35.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 827 - 832
1 Jul 2008
Rees JL

This review discusses the pathogenesis and surgical treatment of tears of the rotator cuff.


Bone & Joint Research
Vol. 4, Issue 3 | Pages 29 - 37
1 Mar 2015
Halim T Clarke IC Burgett-Moreno MD Donaldson TK Savisaar C Bowsher JG

Objectives

Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt–chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA).

Methods

Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1441 - 1448
1 Nov 2014
Bali K Railton P Kiefer GN Powell JN

We report the clinical and radiological outcome of subcapital osteotomy of the femoral neck in the management of symptomatic femoroacetabular impingement (FAI) resulting from a healed slipped capital femoral epiphysis (SCFE). We believe this is only the second such study in the literature.

We studied eight patients (eight hips) with symptomatic FAI after a moderate to severe healed SCFE. There were six male and two female patients, with a mean age of 17.8 years (13 to 29).

All patients underwent a subcapital intracapsular osteotomy of the femoral neck after surgical hip dislocation and creation of an extended retinacular soft-tissue flap. The mean follow-up was 41 months (20 to 84). Clinical assessment included measurement of range of movement, Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis score (WOMAC). Radiological assessment included pre- and post-operative calculation of the anterior slip angle (ASA) and lateral slip angle (LSA), the anterior offset angle (AOA) and centre head–trochanteric distance (CTD). The mean HHS at final follow-up was 92.5 (85 to 100), and the mean WOMAC scores for pain, stiffness and function were 1.3 (0 to 4), 1.4 (0 to 6) and 3.6 (0 to 19) respectively. There was a statistically significant improvement in all the radiological measurements post-operatively. The mean ASA improved from 36.6° (29° to 44°) to 10.3° (5° to 17°) (p <  0.01). The mean LSA improved from 36.6° (31° to 43°) to 15.4° (8° to 21°) (p < 0.01). The mean AOA decreased from 64.4° (50° to 78°) 32.0° (25° to 39°) post-operatively (p < 0.01). The mean CTD improved from -8.2 mm (-13.8 to +3.1) to +2.8 mm (-7.6 to +11.0) (p < 0.01). Two patients underwent further surgery for nonunion. No patient suffered avascular necrosis of the femoral head.

Subcapital osteotomy for patients with a healed SCFE is more challenging than subcapital re-orientation in those with an acute or sub-acute SCFE and an open physis. An effective correction of the deformity, however, can be achieved with relief of symptoms related to impingement.

Cite this article: Bone Joint J 2014;96-B:1441–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 793 - 800
1 Jun 2011
Yalçin N Öztürk A Özkan Y Çelimli N Özocak E Erdogan A Sahin N Ilgezdi S

We studied the effects of hyperbaric oxygen (HBO) and zoledronic acid (ZA) on posterior lumbar fusion using a validated animal model. A total of 40 New Zealand white rabbits underwent posterior lumbar fusion at L5–6 with autogenous iliac bone grafting. They were divided randomly into four groups as follows: group 1, control; group 2, HBO (2.4 atm for two hours daily); group 3, local ZA (20 μg of ZA mixed with bone graft); and group 4, combined HBO and local ZA. All the animals were killed six weeks after surgery and the fusion segments were subjected to radiological analysis, manual palpation, biomechanical testing and histological examination.

Five rabbits died within two weeks of operation. Thus, 35 rabbits (eight in group 1 and nine in groups 2, 3 and 4) completed the study. The rates of fusion in groups 3 and 4 (p = 0.015) were higher than in group 1 (p < 0.001) in terms of radiological analysis and in group 4 was higher than in group 1 with regard to manual palpation (p = 0.015). We found a statistically significant difference in the biomechanical analysis between groups 1 and 4 (p = 0.024). Histological examination also showed a statistically significant difference between groups 1 and 4 (p = 0.036).

Our results suggest that local ZA combined with HBO may improve the success rate in posterior lumbar spinal fusion.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 449 - 454
1 Apr 2014
Laborie LB Lehmann TG Engesæter IØ Sera F Engesæter LB Rosendahl K

We report on gender-specific reference intervals of the alpha angle and its association with other qualitative cam-type findings in femoroacetabular impingement at the hip, according to a population-based cohort of 2038 19-year-olds, 1186 of which were women (58%). The alpha angle was measured on standardised frog-leg lateral and anteroposterior (AP) views using digital measurement software, and qualitative cam-type findings were assessed subjectively on both views by independent observers. In all, 2005 participants (837 men, 1168 women, mean age 18.6 years (17.2 to 20.1) were included in the analysis. For the frog-leg view, the mean alpha angle (right hip) was 47° (26 to 79) in men and 42° (29 to 76) in women, with 97.5 percentiles of 68° and 56°, respectively. For the AP view, the mean values were 62° (40 to 105) and 52° (36 to 103) for men and women, respectively, with 97.5 percentiles of 93° and 94°. Associations between higher alpha angles and all qualitative cam-type findings were seen for both genders on both views. The reference intervals presented for the alpha angle in this cross-sectional study are wide, especially for the AP view, with higher mean values for men than women on both views.

Cite this article: Bone Joint J 2014;96-B:449–54.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1249 - 1255
1 Sep 2008
Nishida H Tsuchiya H Tomita K

We evaluated the possible induction of a systemic immune response to increase anti-tumour activity by the re-implantation of destructive tumour tissue treated by liquid nitrogen in a murine osteosarcoma (LM8) model. The tumours were randomised to treatment by excision alone or by cryotreatment after excision. Tissue from the tumour was frozen in liquid nitrogen, thawed in distilled water and then re-implanted in the same animal. In addition, some mice received an immunological response modifier of OK-432 after treatment. We measured the levels of interferon-gamma and interleukin-12 cytokines and the cytotoxicity activity of splenocytes against murine LM8 osteosarcoma cells. The number of lung and the size of abdominal metastases were also measured.

Re-implantation of tumour tissue after cryotreatment activated immune responses and inhibited metastatic tumour growth. OK-432 synergistically enhanced the anti-tumour effect. Our results suggest that the treatment of malignant bone tumours by reconstruction using autografts containing tumours which have been treated by liquid nitrogen may be of clinical value.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 5 - 18
1 Jan 2014
Leunig M Ganz R

The use of joint-preserving surgery of the hip has been largely abandoned since the introduction of total hip replacement. However, with the modification of such techniques as pelvic osteotomy, and the introduction of intracapsular procedures such as surgical hip dislocation and arthroscopy, previously unexpected options for the surgical treatment of sequelae of childhood conditions, including developmental dysplasia of the hip, slipped upper femoral epiphysis and Perthes’ disease, have become available. Moreover, femoroacetabular impingement has been identified as a significant aetiological factor in the development of osteoarthritis in many hips previously considered to suffer from primary osteoarthritis.

As mechanical causes of degenerative joint disease are now recognised earlier in the disease process, these techniques may be used to decelerate or even prevent progression to osteoarthritis. We review the recent development of these concepts and the associated surgical techniques.

Cite this article: Bone Joint J 2014;96-B:5–18.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 424 - 429
1 Mar 2013
Madan SS Cooper AP Davies AG Fernandes JA

We present our experience of the modified Dunn procedure in combination with a Ganz surgical dislocation of the hip to treat patients with severe slipped capital femoral epiphysis (SCFE). The aim was to prospectively investigate whether this technique is safe and reproducible. We assessed the degree of reduction, functional outcome, rate of complications, radiological changes and range of movement in the hip. There were 28 patients with a mean follow-up of 38.6 months (24 to 84). The lateral slip angle was corrected by a mean of 50.9° (95% confidence interval 44.3 to 57.5). The mean modified Harris hip score at the final follow-up was 89.1 (sd 9.0) and the mean Non-Arthritic Hip score was 91.3 (sd 9.0). Two patients had proven pre-existing avascular necrosis and two developed the condition post-operatively. There were no cases of nonunion, implant failure, infection, deep-vein thrombosis or heterotopic ossification. The range of movement at final follow-up was nearly normal. This study adds to the evidence that the technique of surgical dislocation and anatomical reduction is safe and reliable in patients with SCFE.

Cite this article: Bone Joint J 2013;95-B:424–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 697 - 707
1 Jun 2008
Fraser-Moodie JA Shortt NL Robinson CM

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 10 - 19
1 Jan 2013
Bedi A Kelly BT Khanduja V

The technical advances in arthroscopic surgery of the hip, including the improved ability to manage the capsule and gain extensile exposure, have been paralleled by a growth in the number of conditions that can be addressed. This expanding list includes symptomatic labral tears, chondral lesions, injuries of the ligamentum teres, femoroacetabular impingement (FAI), capsular laxity and instability, and various extra-articular disorders, including snapping hip syndromes. With a careful diagnostic evaluation and technical execution of well-indicated procedures, arthroscopic surgery of the hip can achieve successful clinical outcomes, with predictable improvements in function and pre-injury levels of physical activity for many patients.

This paper reviews the current position in relation to the use of arthroscopy in the treatment of disorders of the hip.

Cite this article: Bone Joint J 2013;95-B:10–19.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 290 - 296
1 Mar 2012
Jayakumar P Ramachandran M Youm T Achan P

Hip arthroscopy is particularly attractive in children as it confers advantages over arthrotomy or open surgery, such as shorter recovery time and earlier return to activity. Developments in surgical technique and arthroscopic instrumentation have enabled extension of arthroscopy of the hip to this age group. Potential challenges in paediatric and adolescent hip arthroscopy include variability in size, normal developmental change from childhood to adolescence, and conditions specific to children and adolescents and their various consequences. Treatable disorders include the sequelae of traumatic and sports-related hip joint injuries, Legg–Calve–Perthes’ disease and slipped capital femoral epiphysis, and the arthritic and septic hip. Intra-articular abnormalities are rarely isolated and are often associated with underlying morphological changes.

This review presents the current concepts of hip arthroscopy in the paediatric and adolescent patient, covering clinical assessment and investigation, indications and results of the experience to date, as well as technical challenges and future directions.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 326 - 331
1 Mar 2011
Javed A O’Donnell JM

We reviewed the clinical outcome of arthroscopic femoral osteochondroplasty for cam femoroacetabular impingement performed between August 2005 and March 2009 in a series of 40 patients over 60 years of age. The group comprised 26 men and 14 women with a mean age of 65 years (60 to 82). The mean follow-up was 30 months (12 to 54).

The mean modified Harris hip score improved by 19.2 points (95% confidence interval 13.6 to 24.9; p < 0.001) while the mean non-arthritic hip score improved by 15.0 points (95% confidence interval 10.9 to 19.1, p < 0.001). Seven patients underwent total hip replacement after a mean interval of 12 months (6 to 24 months) at a mean age of 63 years (60 to 70). The overall level of satisfaction was high with most patients indicating that they would undergo similar surgery in the future to the contralateral hip, if indicated. No serious complications occurred.

Arthroscopic femoral osteochondroplasty performed in selected patients over 60 years of age, who have hip pain and mechanical symptoms resulting from cam femoroacetabular impingement, is beneficial with a minimal risk of complications at a mean follow-up of 30 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 517 - 524
1 Apr 2011
Cox G McGonagle D Boxall SA Buckley CT Jones E Giannoudis PV

The scarcity of mesenchymal stem cells (MSCs) in iliac crest bone marrow aspirate (ICBMA), and the expense and time in culturing cells, has led to the search for alternative harvest sites. The reamer-irrigation-aspirator (RIA) provides continuous irrigation and suction during reaming of long bones. The aspirated contents pass via a filter, trapping bony fragments, before moving into a ‘waste’ bag from which MSCs have been previously isolated. We examined the liquid and solid phases, performed a novel digestion of the solid phase, and made a comparative assessment in terms of number, phenotype and differentiation capacity with matched ICBMA.

The solid fraction from the filtrate was digested for 60 minutes at 37°C with collagenase. Enumeration was performed via the colony-forming unit fibroblast (CFU-F) assay. Passage (P2) cells were differentiated towards osteogenic, adipogenic and chondrogenic lineages, and their phenotypes assessed using flow cytometry (CD33, CD34, CD45, CD73, CD90, and CD105).

MSCs from the RIA phases were able to differentiate at least as well as those from ICBMA, and all fractions had phenotypes consistent with other established sources. The median number of colonies for the three groups was: ICBMA = 8.5 (2 to 86), RIA-liquid = 19.5 (4 to 90), RIA-solid = 109 (67 to 200) per 200 μl. The mean total yield of cells for the three groups was: ICBMA = 920 (0 to 4275), RIA-liquid = 114 983 (16 500 to 477 750), RIA-solid = 12 785 (7210 to 28 475).

The RIA filtrate contains large numbers of MSCs that could potentially be extracted without enzymatic digestion and used for bone repair without prior cell expansion.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 47 - 50
1 Jan 2010
Konan S Rayan F Haddad FS

The radiological evaluation of the anterolateral femoral head is an essential tool for the assessment of the cam type of femoroacetabular impingement. CT, MRI and frog lateral plain radiographs have all been suggested as imaging options for this type of lesion. The alpha angle is accepted as a reliable indicator of the cam type of impingement and may also be used as an assessment for the successful operative correction of the cam lesion.

We studied the alpha angles of 32 consecutive patients with femoroacetabular impingement. The angle measured on frog lateral radiographs using templating tools was compared with that measured on CT scans in order to assess the reliability of the frog lateral view in analysing the alpha angle in cam impingement.

A high interobserver reliability was noted for the assessment of the alpha angle on the frog lateral view with an intraclass correlation coefficient of 0.83. The mean alpha angle measured on the frog lateral view was 58.71° (32° to 83.3°) and that by CT was 65.11° (30° to 102°). A poor intraclass correlation coefficient (0.08) was noted between the measurements using the two systems.

The frog lateral plain radiograph is not reliable for measuring the alpha angle. Various factors may be responsible for this such as the projection of the radiograph, the positioning of the patient and the quality of the image. CT may be necessary for accurate measurement of the alpha angle.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 544 - 544
1 Apr 2008
Fixsen J