Advertisement for orthosearch.org.uk
Results 81 - 100 of 1201
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 118 - 124
1 Jan 1999
Brewster NT Gillespie WJ Howie CR Madabhushi SPG Usmani AS Fairbairn DR

In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses.

We have performed experiments in vitro using morsellised allograft bone from the femoral head which have shown that its mechanical properties improve with increasing normal load and with increasing shear strains (strain hardening). The mechanical strength also increases with increasing compaction energy, and with the addition of bioglass particles to make good the deficiency in small and very small fragments. Donor femoral heads may be milled while frozen without affecting the profile of the particle size. Osteoporotic femoral heads provide a similar grading of sizes, although fewer particles are obtained from each specimen. Our findings have implications for current practice and for the future development of materials and techniques.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 867 - 868
1 Sep 1991
Saleh M


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 179 - 179
1 Jan 1991
Graham G Dent C Jones D


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 152 - 153
1 Jan 1990
Radojevic B Zlatic M


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 332 - 336
1 Aug 1980
Heywood A

A high percentage of hips in patients with rheumatoid arthritis presenting for total joint replacement have protrusio deformity with extremely thin medial acetabular walls. Biomechanical principles suggest that, to prevent inward migration of the acetabular component, the prosthesis should be positioned laterally near the acetabular rim. To reinforce the medial wall, the femoral head is fashioned into a solid graft which is anchored against the medial wall as a plug, minimising the amount of cement used and making the use of wire mesh and restraining rings about the acetabulum unnecessary. A series of nine operations on seven patients is presented. Serial radiographs, tomograms and scintigrams taken after operation suggest satisfactory incorporation of the grafts, and no complications have been encountered in a follow-up period ranging from three months to two years.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1514 - 1520
1 Nov 2013
D’Agostino P Barbier O

The osteoinductive properties of demineralised bone matrix have been demonstrated in animal studies. However, its therapeutic efficacy has yet to be proven in humans. The clinical properties of AlloMatrix, an injectable calcium-based demineralised bone matrix allograft, were studied in a prospective randomised study of 50 patients with an isolated unstable distal radial fracture treated by reduction and Kirschner (K-) wire fixation. A total of 24 patients were randomised to the graft group (13 men and 11 women, mean age 42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18 women, mean age 45.0 years (17 to 69)).

At one, three, six and nine weeks, and six and 12 months post-operatively, patients underwent radiological evaluation, assessments for range of movement, grip and pinch strength, and also completed the Disabilities of Arm, Shoulder and Hand questionnaire. At one and six weeks and one year post-operatively, bone mineral density evaluations of both wrists were performed.

No significant difference in wrist function and speed of recovery, rate of union, complications or bone mineral density was found between the two groups. The operating time was significantly higher in the graft group (p = 0.004). Radiologically, the reduction parameters remained similar in the two groups and all AlloMatrix extraosseous leakages disappeared after nine weeks.

This prospective randomised controlled trial did not demonstrate a beneficial effect of AlloMatrix demineralised bone matrix in the treatment of this category of distal radial fractures treated by K-wire fixation.

Cite this article: Bone Joint J 2013;95-B:1514–20.


Bone & Joint Research
Vol. 3, Issue 7 | Pages 223 - 229
1 Jul 2014
Fleiter N Walter G Bösebeck H Vogt S Büchner H Hirschberger W Hoffmann R

Objective

A clinical investigation into a new bone void filler is giving first data on systemic and local exposure to the anti-infective substance after implantation.

Method

A total of 20 patients with post-traumatic/post-operative bone infections were enrolled in this open-label, prospective study. After radical surgical debridement, the bone cavity was filled with this material. The 21-day hospitalisation phase included determination of gentamicin concentrations in plasma, urine and wound exudate, assessment of wound healing, infection parameters, implant resorption, laboratory parameters, and adverse event monitoring. The follow-up period was six months.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 825 - 831
1 Aug 2002
van Doorn WJ ten Have BLEF van Biezen FC Hop WCJ Ginai AZ Verhaar JAN

We report the initial results of an ongoing randomised, prospective study on migration of the Exeter and Elite Plus femoral stems after impaction allografting, as measured by radiostereometry.

Clinically, the impaction technique gave good results for both stems. The mean subsidence in the first year was 1.30 mm and 0.20 mm for the Exeter and the Elite Plus stems, respectively. In the second year, the Exeter stem continued to subside further by a mean of 0.42 mm, while the Elite Plus stem did not do so. Subsidence of the Exeter stem correlated with deficiency of bone stock as graded on the Gustilo and Pasternak scale. This correlation was not found for the Elite Plus stem. None of the other parameters which were studied predisposed to subsidence. There was no significant association between the amount of subsidence and the radiological appearance of the graft for either stem. Our findings do not support the theory that radial compression, due to subsidence of the Exeter stem, is the essential stimulus for remodelling in impaction allografting.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 391 - 395
1 May 1998
Schreurs BW Slooff TJJH Buma P Gardeniers JWM Huiskes R

We report a long-term review of 60 acetabular components revised using impacted, morsellised bone allografts and a cemented polyethylene cup. The acetabular defects were cavitary (37) or combined (23). Follow-up was for a mean 11.8 years (10 to 15).

Further revision was needed in five hips, two for septic and three for aseptic loosening. The overall survival rate at 11.8 years was 90%; excluding the septic cases it was 94%.

Acetabular reconstruction with impacted morsellised cancellous grafts and cement gives satisfactory long-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery.

Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens.

There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 492 - 497
1 May 2004
Schreurs BW Bolder SBT Gardeniers JWM Verdonschot N Slooff TJJH Veth RPH

This study presents the clinical and radiological results of 62 consecutive acetabular revisions in 58 patients, at a mean of 16.5 years follow-up (15 to 20). The Kaplan-Meier survivorship for the cup with end-point revisions for any reason, was 79% at 15 years (95% confidence interval (CI); 67 to 91). Excluding two revisions for septic loosening at three and six years, and one revision of a well-fixed cup after 12 years in the course of a femoral revision, the survivorship was 84% at 15 years (95% CI; 73 to 95). At review there were no additional cases of loosening, although seven acetabular reconstructions showed radiolucent lines in one or two zones. Acetabular revision using impacted large morsellised bone chips (0.7 cm to 1.0 cm) and a cemented cup, is a reliable technique of reconstruction, when assessed at more than 15 years.


Bone & Joint Research
Vol. 1, Issue 1 | Pages 1 - 7
1 Jan 2012
Rosenberg N Rosenberg O

Objectives

The need for bone tissue supplementation exists in a wide range of clinical conditions involving surgical reconstruction in limbs, the spine and skull. The bone supplementation materials currently used include autografts, allografts and inorganic matrix components; but these pose potentially serious side-effects. In particular the availability of the autografts is usually limited and their harvesting causes surgical morbidity. Therefore for the purpose of supplementation of autologous bone graft, we have developed a method for autologous extracorporeal bone generation.

Methods

Human osteoblast-like cells were seeded on porous granules of tricalcium phosphate and incubated in osteogenic media while exposed to mechanical stimulation by vibration in the infrasonic range of frequencies. The generated tissue was examined microscopically following haematoxylin eosin, trichrome and immunohistochemical staining.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1007 - 1012
1 Sep 2004
Sawaizumi T Nanno M Nanbu A Ito H

A vascularised bone-graft procedure from the base of the second metacarpal was performed in 14 patients with nonunion of the scaphoid. There were 11 men and three women with a mean age of 22 years. In eight patients, who had dorsiflexed intercalated segment instability (DISI), an open wedge was formed at the site of nonunion, and the vascular pedicle was grafted from the volar side. In the six patients without DISI, transplantation was carried out through the same dorsal skin incision.

Complete bony union was obtained in all patients after a mean post-operative period of 10.2 weeks, and DISI was corrected in all affected patients. According to Cooney’s clinical scoring system, the results were excellent in five, good in six, and fair in three patients. Because of its technical simplicity and the limited dissection needed, the procedure should be considered for the primary surgical treatment of patients with nonunion of the scaphoid.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented base plates may confer fewer complications and revisions. Cite this article: Bone Joint J 2022;104-B(12):1334–1342


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were rod fractures preceded by a mean CS of 6.1 mm (2 to 18) and LA kyphotic enhancement of 10.8° (-1 to 36). IF-free survival rates were 75.8% at five years and 56.9% at ten years. The interval from TES to IF peaked at two to three years postoperatively and continued to occur over a period of time thereafter; the early IF-developing group had greater CS at one month postoperatively (CS1M) and more lumbar TES. CS1M ≥ 3 mm and sole use of frozen autografts were identified as independent risk factors for IF. Conclusion. IF is a common complication following TES. We have demonstrated that robust spinal reconstruction preventing CS, and high-quality bone grafting are necessary for successful reconstruction. Cite this article: Bone Joint J 2023;105-B(2):172–179


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 559 - 567
1 May 2023
Aoude A Nikomarov D Perera JR Ibe IK Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims. Giant cell tumour of bone (GCTB) is a locally aggressive lesion that is difficult to treat as salvaging the joint can be associated with a high rate of local recurrence (LR). We evaluated the risk factors for tumour relapse after treatment of a GCTB of the limbs. Methods. A total of 354 consecutive patients with a GCTB underwent joint salvage by curettage and reconstruction with bone graft and/or cement or en bloc resection. Patient, tumour, and treatment factors were analyzed for their impact on LR. Patients treated with denosumab were excluded. Results. There were 53 LRs (15%) at a mean 30.5 months (5 to 116). LR was higher after curettage (18.4%) than after resection (4.6%; p = 0.008). Neither pathological fracture (p = 0.240), Campanacci grade (p = 0.734), soft-tissue extension (p = 0.297), or tumour size (p = 0.872) affected the risk of recurrence. Joint salvage was possible in 74% of patients overall (262/354), and 98% after curettage alone (262/267). Of 49 patients with LR after curettage, 44 (90%) underwent repeated curettage and joint salvage. For patients treated by curettage, only age less than 30 years (p = 0.042) and location in the distal radius (p = 0.043) predicted higher LR. The rate of LR did not differ whether cement or bone graft was used (p = 0.753), but may have been reduced by the use of hydrogen peroxide (p = 0.069). Complications occurred in 15.3% of cases (54/354) and did not differ by treatment. Conclusion. Most patients with a GCTB can undergo successful joint salvage by aggressive curettage, even in the presence of a soft-tissue mass, pathological fracture, or a large lesion, with an 18.4% risk of local recurrence. However, 90% of local relapses after curettage can be treated by repeat joint salvage. Maximizing joint salvage is important to optimize long-term function since most patients with a GCTB are young adults. Younger patients and those with distal radius tumours treated with joint-sparing procedures have a higher rate of local relapse and may require more aggressive treatment and closer follow-up. Cite this article: Bone Joint J 2023;105-B(5):559–567


Bone & Joint Open
Vol. 5, Issue 11 | Pages 999 - 1003
7 Nov 2024
Tan SHS Pei Y Chan CX Pang KC Lim AKS Hui JH Ning B

Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy. Methods. A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided based on their index surgery. Group 1 included patients who underwent excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for their index surgery. Group 2 included patients who underwent all other surgical procedures for their index surgery, including excision of hamartoma, intramedullary rodding, and/or external fixation, without cross-union of the tibia and fibula. Comparisons of the rates of union, refracture, limb length discrepancy, reoperations, and other complications were performed between the two groups. Results. A total of 36 patients were included in the study. Group 1 comprised 13 patients, while Group 2 comprised 23 patients. The mean age at index surgery was four years (1 to 13). The mean duration of follow-up was 4.85 years (1.75 to 14). All patients in Group 1 achieved bony union at a mean of three months (1.5 to 4), but ten of 23 patients in Group 2 had nonunion of the pseudarthrosis (p = 0.006). None of the patients in Group 1 had a refracture, while seven of 13 patients who achieved bony union in Group 2 suffered a refracture (p = 0.005). None of the patients in Group 1 had a limb length discrepancy of more than 2 cm, while ten of 23 patients in Group 2 have a limb length discrepancy of more than 2 cm (p = 0.006). In Group 1, four of 13 patients had a complication, while 16 of 23 patients in Group 2 had a complication (p = 0.004). Excluding removal of implants, four of 13 patients in Group 1 had to undergo additional surgery, while 18 of 23 patients in Group 2 had to undergo additional surgery following the index surgery (p = 0.011). Conclusion. A good index surgery of excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for CPT achieves union and minimizes complications such as refractures, limb length discrepancy, and need for additional surgeries


Bone & Joint 360
Vol. 13, Issue 5 | Pages 28 - 30
1 Oct 2024

The October 2024 Foot & Ankle Roundup. 360. looks at: Hemiarthroplasty for hallux rigidus; Fixed or mobile-bearing ankle arthroplasty? A meta-analysis; Bone grafting for periprosthetic bone cysts following total ankle arthroplasty; Diabetic foot ulcer after first-ray amputation; Early motion after ankle surgery: the path to faster recovery?; Are podiatrists and orthopaedic surgeons approaching zone 2 fifth metatarsal fractures in the same way?


Bone & Joint 360
Vol. 13, Issue 5 | Pages 37 - 39
1 Oct 2024

The October 2024 Spine Roundup. 360. looks at: Analysis of risk factors for non-fusion of bone graft in anterior cervical discectomy and fusion: a clinical retrospective study; Does paraspinal muscle mass predict lumbar lordosis before and after decompression for degenerative spinal stenosis?; Return to work after surgery for lumbar disk herniation: a nationwide registry-based study; Can the six-minute walking test assess ambulatory function impairment in patients with cervical spondylotic myelopathy?; Complications after adult deformity surgery: losing more than sleep; Frailty limits how good we can get in adult spine deformity surgery


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 299 - 304
1 Feb 2021
Goto E Umeda H Otsubo M Teranishi T

Aims. Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. Methods. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation. Results. Radiographs immediately after surgery showed a mean vertical distance from the centre of the hip to the teardrop line of 21.5 mm (SD 3.3; 14.5 to 30.7) and a mean cover of the acetabular component by bone graft of 46% (SD 6%; 32% to 60%). All bone grafts united without collapse, and only three acetabular components loosened. The rate of survival of the acetabular component with mechanical loosening or revision as the endpoint was 86.4% at 25 years after surgery. Conclusion. The technique of using autologous bone graft from the femoral neck and placing a cemented acetabular component in the true acetabulum can provide good long-term outcomes in patients with Crowe type III dislocated hips. Cite this article: Bone Joint J 2021;103-B(2):299–304