Advertisement for orthosearch.org.uk
Results 881 - 900 of 1356
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1436 - 1440
1 Nov 2016
Abdel MP Roth PV Harmsen WS Berry DJ

Aims

The purpose of this study was to determine the lifetime risk of revision surgery for patients undergoing Charnley cemented total hip arthroplasty (THA), with 40-year follow up, using death as a competing risk.

Materials and Methods

We retrospectively reviewed 2000 cemented Charnley THAs, with 51 living hips available at 40 years.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1493 - 1499
1 Nov 2015
Pandit H Hamilton TW Jenkins C Mellon SJ Dodd CAF Murray DW

This prospective study reports the 15-year survival and ten-year functional outcome of a consecutive series of 1000 minimally invasive Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women, 52%, mean age 66 years; 32 to 88). These were implanted by two surgeons involved with the design of the prosthesis to treat anteromedial osteoarthritis and spontaneous osteonecrosis of the knee, which are recommended indications. Patients were prospectively identified and followed up independently for a mean of 10.3 years (5.3 to 16.6).

At ten years, the mean Oxford Knee Score was 40 (standard deviation (sd) 9; 2 to 48): 79% of knees (349) had an excellent or good outcome. There were 52 implant-related re-operations at a mean of 5.5 years (0.2 to 14.7). The most common reasons for re-operation were arthritis in the lateral compartment (2.5%, 25 knees), bearing dislocation (0.7%, seven knees) and unexplained pain (0.7%, seven knees). When all implant-related re-operations were considered as failures, the ten-year rate of survival was 94% (95% confidence interval (CI) 92 to 96) and the 15-year survival rate 91% (CI 83 to 98). When failure of the implant was the endpoint the 15-year survival was 99% (CI 96 to 100).

This is the only large series of minimally invasive UKAs with 15-year survival data. The results support the continued use of minimally invasive UKA for the recommended indications.

Cite this article: Bone Joint J 2015;97-B:1493–99.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1657 - 1662
1 Dec 2014
Stambough JB Clohisy JC Barrack RL Nunley RM Keeney JA

The aims of this retrospective study were to compare the mid-term outcomes following revision total knee replacement (TKR) in 76 patients (81 knees) < 55 years of age with those of a matched group of primary TKRs based on age, BMI, gender and comorbid conditions. We report the activity levels, functional scores, rates of revision and complications. Compared with patients undergoing primary TKR, those undergoing revision TKR had less improvement in the mean Knee Society function scores (8.14 (–55 to +60) vs 23.3 points (–40 to +80), p < 0.001), a similar improvement in UCLA activity level (p = 0.52), and similar minor complication rates (16% vs 13%, p = 0.83) at a mean follow-up of 4.6 years (2 to 13.4). Further revision surgery was more common among revised TKRs (17% vs 5%, p = 0.02), with deep infection and instability being the most common reasons for failure. As many as one-third of patients aged < 55 years in the revision group had a complication or failure requiring further surgery.

Young patients undergoing revision TKR should be counselled that they can expect somewhat less improvement and a higher risk of complications than occur after primary TKR.

Cite this article: Bone Joint J 2014; 96-B:1657–62


Bone & Joint 360
Vol. 5, Issue 5 | Pages 13 - 17
1 Oct 2016


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims

Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA.

Patients and Methods

Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three.

Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89).


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 749 - 754
1 Jun 2015
Syed MA Hutt NJ Shah N Edge AJ

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged <  50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. This represents an update of previous reports of the same cohort at ten and 16 years, which were reported in 2004 and 2009, respectively. We describe the survival, radiological and functional outcomes at a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs, one underwent femoral revision for peri-prosthetic fracture after 21 years, and one patient (one hip) was lost to follow-up. Using aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular revision but none needed femoral revision, demonstrating 100% survival (95% confidence interval 89 to 100).

In young patients with high demands, the Furlong HAC–coated femoral component gives excellent long-term results.

Cite this article: Bone Joint J 2015;97-B:749–54.


Bone & Joint Research
Vol. 5, Issue 6 | Pages 206 - 214
1 Jun 2016
Malak TT Broomfield JAJ Palmer AJR Hopewell S Carr A Brown C Prieto-Alhambra D Glyn-Jones S

Objectives

High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA).

Methods

We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 13 - 15
1 Aug 2017


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims

Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known.

Patients and Methods

Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 120 - 124
1 Jan 2016
Sculco PK Abdel MP Hanssen AD Lewallen DG

The treatment of bone loss in revision total knee arthroplasty has evolved over the past decade. While the management of small to moderate sized defects has demonstrated good results with a variety of traditional techniques (cement and screws, small metal augments, impaction bone grafting or modular stems), the treatment of severe defects continues to be problematic. The use of a structural allograft has declined in recent years due to an increased failure rate with long-term follow-up and with the introduction of highly porous metal augments that emphasise biological metaphyseal fixation. Recently published mid-term results on the use of tantalum cones in patients with severe bone loss has reaffirmed the success of this treatment strategy.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):120–4.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 35 - 37
1 Jun 2017


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1333 - 1341
1 Oct 2016
van der Voort P Valstar ER Kaptein BL Fiocco M van der Heide HJL Nelissen RGHH

Aims

The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA).

Patients and Methods

In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36).


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1436 - 1440
1 Nov 2014
Henderson ER O’Connor MI Ruggieri P Windhager R Funovics PT Gibbons CL Guo W Hornicek FJ Temple HT Letson GD

Previous classification systems of failure of limb salvage focused primarily on endoprosthetic failures and lacked sufficient depth for the effective study of the causes of failure. In order to address these inadequacies, the International Society of Limb Salvage (ISOLS) formed a committee to recommend revisions of the previous systems. The purpose of this study was to report on their recommendations. The modifications were prepared using an earlier, evidence-based model with subclassification based on the existing medical literature. Subclassification for all five primary types of failure of limb salvage following endoprosthetic reconstruction were formulated and a complementary system was derived for the failure of biological reconstruction. An additional classification of failure in paediatric patients was also described.

Limb salvage surgery presents a complex array of potential mechanisms of failure, and a complete and precise classification of types of failure is required. Earlier classification systems lacked specificity, and the evidence-based system outlined here is designed to correct these weaknesses and to provide a means of reporting failures of limb salvage in order to allow the interpretation of outcome following reconstructive surgery.

Cite this article: Bone Joint J 2014;96-B:1436–40.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 160 - 163
1 Feb 2015
Biemond JE Venkatesan S van Hellemondt GG

The long-term survival of the cementless Spotorno CLS femoral component in patients aged > 50 years at the time of arthroplasty was investigated. Survivorship analysis of a consecutive series of 85 patients (100 hips; under 50 years of age at a mean follow-up of 18.4 years (16.3 to 20.8)) was performed. The clinical and radiographic outcomes were satisfactory. The overall rate of survival of the femoral component was 93.5% (95% confidence interval (CI), 90.9 to 96.1) after 19 years. Survival with revision for aseptic loosening as the end point was 95.7% (95% CI 93.6 to 97.8%) at 19 years.

This study demonstrates an excellent long-term survival of the Spotorno CLS femoral component after 16 to 20 years in young patients undergoing total hip arthroplasty.

Cite this article: Bone Joint J 2015;97-B:160–3.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 58 - 64
1 Jan 2016
Ahmed I Salmon LJ Waller A Watanabe H Roe JP Pinczewski LA

Aims

Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known.

Methods

We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis.

The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome.


Bone & Joint 360
Vol. 6, Issue 2 | Pages 37 - 39
1 Apr 2017
Khan T


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1359 - 1365
1 Oct 2014
Large R Tambe A Cresswell T Espag M Clark DI

Medium-term results of the Discovery elbow replacement are presented. We reviewed 51 consecutive primary Discovery total elbow replacements (TERs) implanted in 48 patients. The mean age of the patients was 69.2 years (49 to 92), there were 19 males and 32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69). A total of six patients were lost to follow-up. Statistically significant improvements in range movement and Oxford Elbow Score were found (p < 0.001). Radiolucent lines were much more common in, and aseptic loosening was exclusive to, the humeral component. Kaplan–Meier survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for aseptic loosening. In four TERs, periprosthetic infection occurred resulting in failure. A statistically significant association between infection and increased BMI was found (p = 0.0268). Triceps failure was more frequent after the Mayo surgical approach and TER performed after previous trauma surgery. No failures of the implant were noted.

Our comparison shows that the Discovery has early clinical results that are similar to other semi-constrained TERs. We found continued radiological surveillance with particular focus on humeral lucency is warranted and has not previously been reported. Despite advances in the design of total elbow replacement prostheses, rates of complication remain high.

Cite this article: Bone Joint J 2014;96-B:1359–65


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1267 - 1279
1 Oct 2017
Chughtai M Piuzzi NS Khlopas A Jones LC Goodman SB Mont MA

Non-traumatic osteonecrosis of the femoral head is a potentially devastating condition, the prevalence of which is increasing. Many joint-preserving forms of treatment, both medical and surgical, have been developed in an attempt to slow or reverse its progression, as it usually affects young patients.

However, it is important to evaluate the best evidence that is available for the many forms of treatment considering the variation in the demographics of the patients, the methodology and the outcomes in the studies that have been published, so that it can be used effectively.

The purpose of this review, therefore, was to provide an up-to-date, evidence-based guide to the management, both non-operative and operative, of non-traumatic osteonecrosis of the femoral head.

Cite this article: Bone Joint J 2017;99-B:1267–79.