We investigated the incidence of soft-tissue
lesions after small head metal-on-metal total hip replacement (MoM THR).
Between December 1993 and May 1999, 149 patients (195 hips) underwent
primary cementless MoM THR. During the follow-up period, three patients (five THRs) died
and eight patients (14 THRs) were lost to follow-up. We requested
that all patients undergo CT evaluation. After exclusion of five
patients (six THRs) who had undergone a revision procedure, and
22 (28 THRs) who were unwilling to take part in this study, 111
patients (142 THRs) were evaluated. There were 63 men (88 THRs)
and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56)
at the time of surgery. The mean follow-up was 15.4 years (13 to
19). A soft-tissue lesion was defined as an abnormal peri-prosthetic
collection of fluid, solid lesion or asymmetrical soft-tissue mass. At final follow-up, soft-tissue lesions were found in relation
to 28 THRs (19.7%), including 25 solid and three cystic lesions.
They were found in 20 men and eight women; 26 lesions were asymptomatic
and two were symptomatic. The mean maximal diameter of the soft-tissue
lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions
observed with small head MoM THR remains a concern. Cite this article:
The traditional techniques involving an oblique
tunnel or triangular wedge resection to approach a central or mixed-type
physeal bar are hindered by poor visualisation of the bar. This
may be overcome by a complete transverse osteotomy at the metaphysis
near the growth plate or a direct vertical approach to the bar.
Ilizarov external fixation using small wires allows firm fixation
of the short physis-bearing fragment, and can also correct an associated angular
deformity and permit limb lengthening. We accurately approached and successfully excised ten central-
or mixed-type bars; six in the distal femur, two in the proximal
tibia and two in the distal tibia, without damaging the uninvolved
physis, and corrected the associated angular deformity and leg-length
discrepancy. Callus formation was slightly delayed because of periosteal
elevation and stretching during resection of the bar. The resultant
resection of the bar was satisfactory in seven patients and fair
in three as assessed using a by a modified Williamson–Staheli classification. Cite this article:
Large femoral heads have become popular in total
hip replacement (THR) as a method of reducing the risk of dislocation.
However, if large heads are used in ceramic-on-ceramic THR, the
liner must be thinner, which may increase the risk of fracture.
To compare the rates of ceramic fracture and dislocation between
28 mm and 32 mm ceramic heads, 120 hips in 109 patients (51 men
and 58 women, mean age 49.2 years) were randomised to THR with either
a 28 mm or a 32 mm ceramic articulation. A total of 57/60 hips assigned
to the 28 mm group and 55/60 hips assigned to the 32 mm group were
followed for at least five years. No ceramic component fractures
occured in any patient in either group. There was one dislocation
in the 32 mm group and none in the 28 mm group (p = 0.464). No hip
had detectable wear, focal osteolysis or prosthetic loosening. In
our small study the 32 mm ceramic articulation appeared to be safe
in terms of ceramic liner fracture. Cite this article:
We assessed the orientation of the acetabular
component in 1070 primary total hip arthroplasties with hard-on-soft, small
diameter bearings, aiming to determine the size and site of the
target zone that optimises outcome. Outcome measures included complications,
dislocations, revisions and ΔOHS (the difference between the Oxford
Hip Scores pre-operatively and five years post-operatively). A wide
scatter of orientation was observed (2 This study demonstrated that with traditional technology surgeons
can only reliably achieve a target zone of ±15°. As the optimal
zone to diminish the risk of dislocation is also ±15°, surgeons
should be able to achieve this. This is the first study to demonstrate
that optimal orientation of the acetabular component improves the
functional outcome. However, the target zone is small (± 5°) and
cannot, with current technology, be consistently achieved. Cite this article:
The most common reasons for revision of unicompartmental
knee arthroplasty (UKA) are loosening and pain. Cementless components
may reduce the revision rate. The aim of this study was to compare
the fixation and clinical outcome of cementless and cemented Oxford
UKAs. A total of 43 patients were randomised to receive either a cemented
or a cementless Oxford UKA and were followed for two years with
radiostereometric analysis (RSA), radiographs aligned with the bone–implant
interfaces and clinical scores. The femoral components migrated significantly during the first
year (mean 0.2 mm) but not during the second. There was no significant
difference in the extent of migration between cemented and cementless
femoral components in either the first or the second year. In the
first year the cementless tibial components subsided significantly
more than the cemented components (mean 0.28 mm ( As second-year migration is predictive of subsequent loosening,
and as radiolucency is suggestive of reduced implant–bone contact,
these data suggest that fixation of the cementless components is
at least as good as, if not better than, that of cemented devices. Cite this article:
A modular femoral head–neck junction has practical
advantages in total hip replacement. Taper fretting and corrosion
have so far been an infrequent cause of revision. The role of design
and manufacturing variables continues to be debated. Over the past
decade several changes in technology and clinical practice might
result in an increase in clinically significant taper fretting and
corrosion. Those factors include an increased usage of large diameter
(36 mm) heads, reduced femoral neck and taper dimensions, greater
variability in taper assembly with smaller incision surgery, and
higher taper stresses due to increased patient weight and/or physical
activity. Additional studies are needed to determine the role of
taper assembly compared with design, manufacturing and other implant
variables. Cite this article:
Unicompartmental knee arthroplasty (UKA) has
advantages over total knee arthroplasty but national joint registries report
a significantly higher revision rate for UKA. As a result, most
surgeons are highly selective, offering UKA only to a small proportion
(up to 5%) of patients requiring arthroplasty of the knee, and consequently
performing few each year. However, surgeons with large UKA practices
have the lowest rates of revision. The overall size of the practice
is often beyond the surgeon’s control, therefore case volume may
only be increased by broadening the indications for surgery, and
offering UKA to a greater proportion of patients requiring arthroplasty
of the knee. The aim of this study was to determine the optimal UKA usage
(defined as the percentage of knee arthroplasty practice comprised
by UKA) to minimise the rate of revision in a sample of 41 986 records
from the for National Joint Registry for England and Wales (NJR). UKA usage has a complex, non-linear relationship with the rate
of revision. Acceptable results are achieved with the use of 20%
or more. Optimal results are achieved with usage between 40% and
60%. Surgeons with the lowest usage (up to 5%) have the highest
rates of revision. With optimal usage, using the most commonly used
implant, five-year survival is 96% (95% confidence interval (CI)
94.9 to 96.0), compared with 90% (95% CI 88.4 to 91.6) with low
usage (5%) previously considered ideal. The rate of revision of UKA is highest with low usage, implying
the use of narrow, and perhaps inappropriate, indications. The widespread
use of broad indications, using appropriate implants, would give
patients the advantages of UKA, without the high rate of revision. Cite this article:
Macrodactyly of the foot is a rare but disabling
condition. We present the results of surgery on 18 feet of 16 patients, who
underwent ray amputation and were followed-up for more than two
years at a mean of 80 months (25 to 198). We radiologically measured the intermetatarsal width and forefoot
area pre-operatively and at six weeks and two years after surgery.
We also evaluated the clinical results using the Oxford Ankle Foot
Questionnaire for children (OxAFQ-C) and the Questionnaire for Foot
Macrodactyly. The intermetatarsal width and forefoot area ratios were significantly
decreased after surgery. The mean OxAFQ-C score was 42 (16 to 57)
pre-operatively, improving to 47 (5 to 60) at two years post-operatively
(p = 0.021). The mean questionnaire for Foot Macrodactyly score
two years after surgery was 8 (6 to 10). Ray amputation gave a measurable reduction in foot size with
excellent functional results. For patients with metatarsal involvement,
a motionless toe, or involvement of multiple digits, ray amputation
is a clinically effective option which is acceptable to patients. Cite this article:
An ongoing prospective study to investigate failing metal-on-metal
hip prostheses was commenced at our centre in 2008. We report on
the results of the analysis of the first consecutive 126 failed
mated total hip prostheses from a single manufacturer. Analysis was carried out using highly accurate coordinate measuring
to calculate volumetric and linear rates of the articular bearing
surfaces and also the surfaces of the taper junctions. The relationship
between taper wear rates and a number of variables, including bearing
diameter and orientation of the acetabular component, was investigated.Objectives
Methods
This study compared the outcome of total knee
replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses
during the first post-operative year and at five years’ follow-up,
using gait parameters as a new objective measure. This double-blind
randomised controlled clinical trial included 55 patients with mobile-bearing (n
= 26) and fixed-bearing (n = 29) prostheses of the same design,
evaluated pre-operatively and post-operatively at six weeks, three
months, six months, one year and five years. Each participant undertook
two walking trials of 30 m and completed the EuroQol questionnaire,
Western Ontario and McMaster Universities osteoarthritis index,
Knee Society score, and visual analogue scales for pain and stiffness.
Gait analysis was performed using five miniature angular rate sensors
mounted on the trunk (sacrum), each thigh and calf. The study population
was divided into two groups according to age (≤ 70 years Improvements in most gait parameters at five years’ follow-up
were greater for fixed-bearing TKRs in older patients (>
70 years),
and greater for mobile-bearing TKRs in younger patients (≤ 70 years).
These findings should be confirmed by an extended age controlled
study, as the ideal choice of prosthesis might depend on the age
of the patient at the time of surgery.
Since the Oxford knee was first used unicompartmentally
in 1982, a small number of bearings have fractured. Of 14 retrieved
bearings, we examined ten samples with known durations
The purpose of this study was to evaluate the
change in sagittal tibiotalar alignment after total ankle arthroplasty (TAA)
for osteoarthritis and to investigate factors affecting the restoration
of alignment. This retrospective study included 119 patients (120 ankles) who
underwent three component TAA using the Hintegra prosthesis. A total
of 63 ankles had anterior displacement of the talus before surgery
(group A), 49 had alignment in the normal range (group B), and eight
had posterior displacement of the talus (group C). Ankles in group
A were further sub-divided into those in whom normal alignment was
restored following TAA (41 ankles) and those with persistent displacement
(22 ankles). Radiographic and clinical results were assessed. Pre-operatively, the alignment in group A was significantly more
varus than that in group B, and the posterior slope of the tibial
plafond was greater (p <
0.01 in both cases). The posterior slope
of the tibial component was strongly associated with restoration
of alignment: ankles in which the alignment was restored had significantly
less posterior slope (p <
0.001). An anteriorly translated talus was restored to a normal position
after TAA in most patients. We suggest that surgeons performing
TAA using the Hintegra prosthesis should aim to insert the tibial
component at close to 90° relative to the axis of the tibia, hence
reducing posterior soft-tissue tension and allowing restoration
of normal tibiotalar alignment following surgery. Cite this article:
The August 2015 Foot &
Ankle Roundup360 looks at: Is orthosis more important than physio in tibialis posterior deficiency?; Radiographic evaluation of ankle injury; Sciatic catheter quite enough!; A fresh look at avascular necrosis of the talus; Total ankle and VTE; Outcomes of posterior malleolar fracture; Absorbable sutures in the Achilles tendon; Lisfranc injuries under the spotlight
The August 2015 Spine Roundup360 looks at: Steroids may be useful in avoiding dysphagia in anterior cervical discectomy and fusion (ACDF); Perhaps X-Stop ought to stop?; Is cervical plexus block in ACDF the gateway to day case spinal surgery?; Epidural past its heyday?; Steroids in lumbar back pain; Lumbar disc replacement improving; Post-discectomy arthritis
This study reports the clinical outcome of reconstruction
of deficient abductor muscles following revision total hip arthroplasty
(THA), using a fresh–frozen allograft of the extensor mechanism
of the knee. A retrospective analysis was conducted of 11 consecutive
patients with a severe limp because of abductor deficiency which
was confirmed on MRI scans. The mean age of the patients (three
men and eight women) was 66.7 years (52 to 84), with a mean follow-up
of 33 months (24 to 41). Following surgery, two patients had no limp, seven had a mild
limp, and two had a persistent severe limp (p = 0.004). The mean
power of the abductors improved on the Medical Research Council
scale from 2.15 to 3.8 (p <
0.001). Pre-operatively, all patients
required a stick or walking frame; post-operatively, four patients
were able to walk without an aid. Overall, nine patients had severe
or moderate pain pre-operatively; ten patients had no or mild pain
post-operatively. At final review, the Harris hip score was good in five patients,
fair in two and poor in four. We conclude that using an extensor mechanism allograft is relatively
effective in the treatment of chronic abductor deficiency of the
hip after THA when techniques such as local tissue transfer are
not possible. Longer-term follow-up is necessary before the technique can be
broadly applied. Cite this article:
The August 2015 Hip &
Pelvis Roundup360 looks at: The well-fixed acetabular revision; Predicting complications in revision arthroplasty; Is infection associated with fixation?; Front or back? An enduring question in hip surgery; Muscle-sparing approaches?; Gabapentin as a post-operative analgesic adjunct; An Indian take on AVN of the hip; Weight loss and arthroplasty
The August 2015 Trauma Roundup360 looks at: Thromboprophylaxis not required in lower limb fractures; Subclinical thyroid dysfunction and fracture risk: moving the boundaries in fracture; Posterior wall fractures refined; Neurological injury and acetabular fracture surgery; Posterior tibial plateau fixation; Tibial plateau fractures in the longer term; Comprehensive orthogeriatric care and hip fracture; Compartment syndrome: in the eye of the beholder?
The aims of this piece of work were to: 1) record the background
concentrations of blood chromium (Cr) and cobalt (Co) concentrations
in a large group of subjects; 2) to compare blood/serum Cr and Co
concentrations with retrieved metal-on-metal (MoM) hip resurfacings;
3) to examine the distribution of Co and Cr in the serum and whole
blood of patients with MoM hip arthroplasties; and 4) to further
understand the partitioning of metal ions between the serum and
whole blood fractions. A total of 3042 blood samples donated to the local transfusion
centre were analysed to record Co and Cr concentrations. Also, 91
hip resurfacing devices from patients who had given pre-revision
blood/serum samples for metal ion analysis underwent volumetric
wear assessment using a coordinate measuring machine. Linear regression analysis
was carried out and receiver operating characteristic curves were
constructed to assess the reliability of metal ions to identify
abnormally wearing implants. The relationship between serum and
whole blood concentrations of Cr and Co in 1048 patients was analysed
using Bland-Altman charts. This relationship was further investigated
in an Objectives
Methods