We describe the survivorship of the Exeter femoral component in a District General Hospital. Between 1994 and 1996, 230 Exeter Universal cemented femoral components were implanted in 215 patients who were reviewed at a mean of 11.2 years (10 to 13). We used one acetabular implant, the Elite Ogee component, in 218 of the 230 hips. During the period of this study 76 patients (79 hips) died. Of the remaining 139 patients (151 hips), 121 were able to attend for radiological analysis at a minimum of ten years. One patient was lost to follow-up. No femoral component was revised for aseptic loosening. Three hips were revised for deep infection and six acetabular components required revision, four for loosening and two for recurrent dislocation. Taking the ‘worst-case scenario’ including the one patient lost to follow-up, the overall survival rate was 94.4% at 13 years. Our results confirm excellent medium-term results for the Exeter Universal femoral component, implanted in a general setting. The excellent survival of this femoral component, when used in combination with the Ogee acetabular component, suggests that this is a successful pairing.
We describe the survivorship of the Medial Rotation total knee replacement (TKR) at ten years in 228 cemented primary replacements implanted between October 1994 and October 2006, with their clinical and radiological outcome. This implant has a highly congruent medial compartment, with the femoral component represented by a portion of a sphere which articulates with a matched concave surface on the medial side of the tibial insert. There were 78 men (17 bilateral TKRs) and 111 women (22 bilateral TKRs) with a mean age of 67.9 years (28 to 90). All the patients were assessed clinically and radiologically using the American Knee Society scoring systems. The mean follow-up was for six years (1 to 13) with only two patients lost to follow-up and 34 dying during the period of study, one of whom had required revision for infection. There were 11 revisions performed in total, three for aseptic loosening, six for infection, one for a periprosthetic fracture and one for a painful but well-fixed replacement performed at another centre. With revision for any cause as the endpoint, the survival at ten years was 94.5% (95% CI 85.1 to 100), and with aseptic loosening as the endpoint 98.4% (95% CI 93 to 100). The mean American Knee Society score improved from 47.6 (0 to 88) to 72.2 (26 to 100) and for function from 45.1 (0 to 100) to 93.1 (45 to 100). Radiological review failed to detect migration in any of the surviving knees. The clinical and radiological results of the Medial Rotation TKR are satisfactory at ten years. The increased congruence of the medial compartment has not led to an increased rate of loosening and continued use can be supported.
Migration of the acetabular component may give rise to oval-shaped bone defects in the acetabulum. The oblong implant is designed to fill these defects and achieve a stable cementless anchorage with no significant bone loss. We prospectively reviewed 133 oblong long oblique revision components at a mean follow-up of 9.74 years (0.6 to 14). All had been used in revisions for defects of type IIB to IIIB according to Paprosky. Aseptic loosening was the reason for revision in 11 cases (8.3%) and deep infection in seven (5.3%). The probability of implant survival over a 12-year follow-up estimated by the Kaplan-Meier method gave a survival rate of 0.85% respectively 0.90% when deep infection was excluded as the endpoint. Our study supports the use of these components in defects from IIB to IIIA. The main precondition for success is direct contact of more than half of the surface of the implant with the host acetabular bone.
We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time. At ten years after operation 238 patients (244 knees) remained for independent clinical and radiological assessment. There was a significant improvement (p <
0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% (95% CI 96 to 98) and survival using reoperation for any cause was 92% (95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees. There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score (p <
0.001). The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.
The incidence of metastatic osteosarcoma is increasing because of improved results following multi-agent chemotherapy and resection of the primary tumour. Metastases occur most commonly in the lungs, whereas bowel metastases are rare. We describe a 25-year-old female who presented with melaena six years after successful resection of an osteosarcoma of her right femur, and one year after resection of a solitary pulmonary metastasis. Imaging revealed a lesion arising within both the duodenum and the pancreas for which a Whipple’s pancreatoduodenectomy was carried out, achieving complete resection. Histological examination confirmed the diagnosis of metastatic osteosarcoma. We believe this is only the second such case reported. At 11 months post-operatively she had no detectable disease. Although rare, osteosarcoma can metastasise to the intestine. The surgeon must be aware of this complication, and that bowel metastases are potentially resectable.
We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris.
We present a series of 30 uncemented total hip replacements performed between June 1985 and January 2002 with a mean follow-up of seven years (5 to 20) in 27 patients who had previously undergone a valgus intertrochanteric osteotomy. No further osteotomy was undertaken to enable hip replacement. We used a number of uncemented modular or monoblock femoral components, acetabular components and bearings. The patients were followed up clinically and radiologically. We report 100% survival of the femoral component. One acetabular component was revised at five years post-implantation for aseptic loosening. We noted cortical hypertrophy around the tip of the monoblock stems in six patients. We believe that modular femoral components should be used when undertaking total hip replacement in patients who have previously undergone valgus femoral osteotomy.
Although the importance of sound statistical principles in the design and analysis of data has gained prominence in recent years, biostatistics, the application of statistics to the analysis of biological and medical data, is still a subject which is poorly understood and often mishandled. This review introduces, in the context of orthopaedic research, the terminology and the principles involved in simple data analysis, and outlines areas of medical statistics that have gained prominence in recent years. It also lists and provides an insight into some of the more common errors that occur in published orthopaedic journals and which are frequently encountered at the review stage in papers submitted to the
The first 325 Exeter Universal stems (309 patients) implanted at the originating centre were inserted between March 1988 and February 1990 by a group of surgeons with differing experience. In this report we describe the clinical and radiological results at a mean of 15.7 years (14.7 to 17.3) after operation with no loss to follow-up. There were 97 patients (108 hips) with replacements still in situ and 31 (31 hips) who had undergone a further procedure. With an endpoint of revision for aseptic loosening, the survivorship at 17 years was 100% and 90.4% for the femoral and acetabular component, respectively. The mean Merle D’Aubigné and Postel scores at review were 5.4 (
The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late deep infection which required a two-stage revision arthroplasty, with a good final result. The incidence of infection in HIV-positive and negative patients was thus similar. One knee in a patient with inhibitor had excessive bleeding due to a pseudoaneurysm which required embolisation. The results were excellent in 27 knees (77%), good in six (17%) and fair in two (6%). The survival rate at 7.5 years taking removal of the prosthesis for loosening or infection as the end-point was 97%. The mechanical survival of total knee replacements in haemophiliacs is very good. Our results confirm that this is a reproducible procedure in haemophilia, even in HIV-positive patients with a CD4 count >
200 mm3 and those with inhibitors. Our rate of infection was lower than previously reported. This could be due to better control of the HIV status with highly active anti-retroviral therapy and the use of antibiotic-loaded cement.
The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted trays in the contained defects is equivalent to that of an uncemented primary knee replacement. However, there is little biomechanical evidence on which to base a decision in the treatment of uncontained defects. We undertook a laboratory-based biomechanical study comparing three methods of graft containment in segmental medial tibial defects and compared them with the use of a modular metal augment to bypass the defect. Using resin models of the proximal tibia with medial defects representing either 46% or 65% of the medial cortical rim, repair of the defect was accomplished using mesh, cement or a novel bag technique, after which impaction bone grafting was used to fill the contained defects and a tibial component was cemented in place. As a control, a cemented tibial component with modular metal augments was used in identical defects. All specimens were submitted to cyclical mechanical loading, during which cyclical and permanent tray displacement were determined. The results showed satisfactory stability with all the techniques except the bone bag method. Using metal augments gave the highest initial stability, but obviously lacked any potential for bone restoration.
We investigated the use of hypoxia-inducible factor (HIF) proteins as prognostic markers in chondrosarcoma and the relationship of HIF to the biological characteristics of cartilage tumours. The expression of HIF-1α, HIF-2α, proliferating cell nuclear antigen (PCNA) and microvessel density (MVD) were measured immunohistochemically in 29 specimens of cartilage tumour. There was no HIF-1α and HIF-2α staining in any of the nine benign cartilage tumours. In 20 specimens of chondrosarcoma, the rate of HIF-1α and HIF-2α expression was 40% and 25%, respectively. The tumour size (≥ 8 cm), histological grade (grade 2 and grade 3) surgical margin (marginal and intralesional) and HIF-1α expression (positive) correlated significantly with a shorter disease-free survival. There was a significant association between HIF-1α and the MVD and a strong trend towards a correlation between HIF-1α and the PCNA index or histological grade. Our findings suggest that HIF-1α protein may be a useful objective marker in the assessment of the prognosis in chondrosarcoma, since it plays an important role in tumour angiogenesis and cell proliferation.
We investigated the pre-operative and one-year post-operative health-related quality of life (HRQoL) outcome by using a Euroqol (EQ-5D) questionnaire in 230 patients who underwent surgery for lumbar spinal stenosis. Data were obtained from the National Swedish Registry for operations on the lumbar spine between 2001 and 2002. We analysed the pre- and postoperative quality of life data, age, gender, smoking habits, pain and walking ability. The relative differences were compared to a Swedish EQ-5D population survey. The mean age of the patients was 66 years, and there were 123 females (53%). Before the operation 62 (27%) of the patients could walk more than 500 m. One year after the operation 150 (65%) were able to walk 500 m or more. The mean EQ-5D score improved from 0.36 to 0.64, and the HRQoL improved in 184 (80%) of the patients. However, they did not reach the level reported by a matched population sample (mean difference 0.18). Women had lower pre- and post-operative EQ-5D scores than men. Severe low back pain was a predictor for a poor outcome.
The medial rotation contracture caused by weak external rotation secondary to obstetric brachial plexus injury leads to deformation of the bones of the shoulder. Scapular hypoplasia, elevation and rotation deformity are accompanied by progressive dislocation of the humeral head. Between February and August 2005, 44 children underwent a new surgical procedure called the ‘triangle tilt’ operation to correct this bony shoulder deformity. Surgical levelling of the distal acromioclavicular triangle combined with tightening of the posterior glenohumeral capsule (capsulorrhaphy) improved shoulder function and corrected the glenohumeral axis in these patients. The posture of the arm at rest was improved and active external rotation increased by a mean of 53° (0° to 115°) in the 40 children who were followed up for more than one year. There was a mean improvement of 4.9 points (1.7 to 8.3) of the Mallet shoulder function score after surgical correction of the bony deformity.
We have investigated the oncological outcome of 63 patients with soft-tissue sarcomas of the hand managed at three major centres in the United Kingdom. There were 44 males and 19 females with a mean age of 45 years (11 to 92). The three most common diagnoses were synovial sarcoma, clear cell sarcoma and epithelioid sarcoma. Local excision was carried out in 45 patients (71%) and amputation in 18 (29%). All those treated by amputation had a wide margin of excision but this was only achieved in 58% of those treated by local excision. The risk of local recurrence was 6% in those treated by amputation compared with 42% for those who underwent attempted limb salvage. An inadequate margin of excision resulted in a 12 times greater risk of local recurrence when compared with those in whom a wide margin of excision had been achieved. We were unable to demonstrate any role for radiotherapy in decreasing the risk of local recurrence when there was an inadequate margin of excision. Patients with an inadequate margin of excision had a much higher risk of both local recurrence and metastasis than those with wide margins. The overall survival rate at five years was 87% and was related to the grade and size of the tumour and to the surgical margin. We have shown that a clear margin of excision is essential to achieve local control of a soft-tissue sarcoma in the hand and that failure to achieve this results in a high risk of both local recurrence and metastastic disease.
The dysplasia cup, which was devised as an adjunct to the Birmingham Hip Resurfacing system, has a hydroxyapatite-coated porous surface and two supplementary neutralisation screws to provide stable primary fixation, permit early weight-bearing, and allow incorporation of morcellised autograft without the need for structural bone grafting. A total of 110 consecutive dysplasia resurfacing arthroplasties in 103 patients (55 men and 48 women) performed between 1997 and 2000 was reviewed with a minimum follow-up of six years. The mean age at operation was 47.2 years (21 to 62) and 104 hips (94%) were Crowe grade II or III. During the mean follow-up of 7.8 years (6 to 9.6), three hips (2.7%) were converted to a total hip replacement at a mean of 3.9 years (2 months to 8.1 years), giving a cumulative survival of 95.2% at nine years (95% confidence interval 89 to 100). The revisions were due to a fracture of the femoral neck, a collapse of the femoral head and a deep infection. There was no aseptic loosening or osteolysis of the acetabular component associated with either of the revisions performed for failure of the femoral component. No patient is awaiting a revision. The median Oxford hip score in 98 patients with surviving hips at the final review was 13 and the 10th and the 90th percentiles were 12 and 23, respectively.
We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis.
The in-cement technique for revision hip arthroplasty involves retaining the original cement-bone interface. This has been proven to be a biomechanically stronger method than recementing after complete removal of the original cement mantle. This study reviewed a series of 54 consecutive revision hip arthroplasty procedures, using the in-cement technique, between November 1999 and November 2003. Clinical and radiological follow-up included functional assessment. There were 54 procedures performed in 51 patients, whose mean age at surgery was 70.3 years (45 to 85). A total of 42 were available at a mean follow-up of 29.2 months (6 to 51). There was no radiological evidence of loosening. Functional assessments were available for 40 patients who had a mean Harris hip score of 85.2 (51.9 to 98.5), a mean Oxford hip score of 19.6 (12 to 41), a mean UCLA activity profile score of 5.9 (3 to 8) and a mean SF-36 score of 78.0 (31.6 to 100). The in-cement technique provides consistent, high functional outcomes and should be considered in appropriately selected cases.