The aim of this study was to report a single surgeon series of
consecutive patients with moderate hallux valgus managed with a
percutaneous extra-articular reverse-L chevron (PERC) osteotomy. A total of 38 patients underwent 45 procedures. There were 35
women and three men. The mean age of the patients was 48 years (17
to 69). An additional percutaneous Akin osteotomy was performed
in 37 feet and percutaneous lateral capsular release was performed
in 22 feet. Clinical and radiological assessments included the type
of forefoot, range of movement, the American Orthopedic Foot and
Ankle (AOFAS) score, a subjective rating and radiological parameters. The mean follow-up was 59.1 months (45.9 to 75.2). No patients
were lost to follow-up.Aims
Patients and Methods
The April 2015 Children’s orthopaedics Roundup360 looks at: Reducing the incidence of DDH – is ‘back carrying’ the answer?; Surgical approach and AVN may not be linked in DDH; First year routine radiographic follow up for scoliosis not necessary; Diagnosis of osteochondritis dessicans; Telemedicine in paediatrics; Regional anesthesia in supracondylar fractures?
The number of arthroplasties being performed
increases each year. Patients undergoing an arthroplasty are at
risk of venous thromboembolism (VTE) and appropriate prophylaxis
has been recommended. However, the optimal protocol and the best
agent to minimise VTE under these circumstances are not known. Although
many agents may be used, there is a difference in their efficacy
and the risk of bleeding. Thus, the selection of a particular agent relies
on the balance between the desire to minimise VTE and the attempt
to reduce the risk of bleeding, with its undesirable, and occasionally
fatal, consequences. Acetylsalicylic acid (aspirin) is an agent for VTE prophylaxis
following arthroplasty. Many studies have shown its efficacy in
minimising VTE under these circumstances. It is inexpensive and
well-tolerated, and its use does not require routine blood tests.
It is also a ‘milder’ agent and unlikely to result in haematoma
formation, which may increase both the risk of infection and the
need for further surgery. Aspirin is also unlikely to result in persistent
wound drainage, which has been shown to be associated with the use
of agents such as low-molecular-weight heparin (LMWH) and other
more aggressive agents. The main objective of this review was to summarise the current
evidence relating to the efficacy of aspirin as a VTE prophylaxis
following arthroplasty, and to address some of the common questions
about its use. There is convincing evidence that, taking all factors into account,
aspirin is an effective, inexpensive, and safe form of VTE following
arthroplasty in patients without a major risk factor for VTE, such
as previous VTE. Cite this article:
We compared thromboembolic events, major haemorrhage
and death after total hip replacement in patients receiving either
aspirin or low-molecular-weight heparin (LMWH). We analysed data from
the National Joint Registry for England and Wales linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 108 584 patients operated on between April 2003 and September 2008
were included and followed up for 90 days. Multivariable risk modelling
and propensity score matching were used to estimate odds ratios
(OR) adjusted for baseline risk factors. An OR <
1 indicates
that rates are lower with LMWH than with aspirin. In all, 21.1%
of patients were prescribed aspirin and 78.9% LMWH. Without adjustment, we
found no statistically significant differences. The rate of pulmonary
embolism was 0.68% in both groups and 90-day mortality was 0.65%
with aspirin and 0.61% with LMWH (OR 0.93; 95% CI 0.77 to 1.11).
With risk adjustment, the difference in mortality increased (OR
0.84; 95% CI 0.69 to 1.01). With propensity score matching the mortality difference
increased even further to 0.65% with aspirin and 0.51% with LMWH
(OR 0.77; 95% CI 0.61 to 0.98). These results should be considered
when the conflicting recommendations of existing guidelines for
thromboprophylaxis after hip replacement are being addressed.
We report a systematic review and meta-analysis of published randomised controlled trials evaluating the efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion in total hip replacement (THR). The data were evaluated using the generic evaluation tool designed by the Cochrane Bone, Joint and Muscle Trauma Group. We identified 11 clinical trials which were suitable for detailed extraction of data. There were no trials that used TXA in revision THR. A total of seven studies (comprising 350 patients) were eligible for the blood loss outcome data. The use of TXA reduced intra-operative blood loss by a mean of 104 ml (95% confidence interval (CI) −164 to −44, p = 0.0006, heterogeneity I2 0%), postoperative blood loss by a mean of 172 ml (95% CI −263 to −81, p = 0.0002, heterogeneity I2 63%) and total blood loss by a mean of 289 ml (95% CI −440 to −138, p <
0.0002, heterogeneity I2 54%). TXA led to a significant reduction in the proportion of patients requiring allogeneic blood transfusion (risk difference −0.20, 95% CI −0.29 to −0.11, p <
0.00001, I2 15%). There were no significant differences in deep-vein thrombosis, pulmonary embolism, infection rates or other complications among the study groups.
The August 2014 Oncology Roundup360 looks at: Anaesthesic modality does not affect outcomes in tumour surgery; infection predictors in orthopaedic oncology; sarcoma depth unimportant in survival; photon/proton radiotherapy surprisingly effective in chondrosarcoma control; total humerus replacement a success!; LDH simple predictor of survival in sarcoma; Denosumab again! and Oops procedures in triplicate.
We compared thromboembolic events, major haemorrhage
and death after knee replacement in patients receiving either aspirin
or low-molecular-weight heparin (LMWH). Data from the National Joint
Registry for England and Wales were linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 156 798 patients between April 2003 and September 2008
were included and followed for 90 days. Multivariable risk modelling
was used to estimate odds ratios adjusted for baseline risk factors
(AOR). An AOR <
1 indicates that risk rates are lower with LMWH
than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin
and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically
significant differences between the aspirin and LMWH groups in the
rate of pulmonary embolism (0.49% These results should be considered when the existing guidelines
for thromboprophylaxis after knee replacement are reviewed.
The place of thromboprophylaxis in arthroplasty surgery remains
controversial, with a challenging requirement to balance prevention
of potentially fatal venous thrombo-embolism with minimising wound-related
complications leading to deep infection. We compared the incidence
of fatal pulmonary embolism in patients undergoing elective primary
total hip arthroplasty (THA) between those receiving aspirin, warfarin
and low molecular weight heparin (LMWH) for the chemical component
of a multi-modal thromboprophylaxis regime. A prospective audit database was used to identify patients who
had died within 42 and 90 days of surgery respectively between April
2000 and December 2012. A case note review was performed to ascertain
the causes of death.Aims
Patients and Methods
Intra-operative, peri-articular injection of
local anaesthesia is an increasingly popular way of controlling
pain following total knee replacement. The evidence from this study suggests that it is safe to use
peri-articular injection in combination with auto-transfusion of
blood from peri-articular drains during knee replacement surgery.
We report a case of iatrogenic sciatic nerve injury caused by pre-operative intraneural injection of local anaesthetic at total hip replacement. To our knowledge, this is unreported in the orthopaedic literature. We consider sacral nerve blockade in patients undergoing total hip replacement to be undesirable and present guidelines for the management of peri-operative sciatic nerve injury.
Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss. We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.
The purpose of the study was to investigate whether closed intramedullary
(IM) nailing with percutaneous cement augmentation is better than
conventional closed nailing at relieving pain and suppressing tumours
in patients with metastases of the femur and humerus. A total of 43 patients (27 men, 16 women, mean age 63.7 years,
standard deviation (Aims
Patients and Methods
To review the current best surgical practice and detail a multi-disciplinary
approach that could further reduce joint replacement infection. Review of relevant literature indexed in PubMed.Objectives
Methods
We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
A retrospective study was performed in 18 patients
with achondroplasia, who underwent bilateral humeral lengthening
between 2001 and 2013, using monorail external fixators. The mean
age was ten years (six to 15) and the mean follow-up was 40 months
(12 to 104). The mean disabilities of the arm, shoulder and hand (DASH) score
fell from 32.3 (20 to 40)
pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A
mean lengthening of 60% (40% to 95%) was required to reach the goal
of independent perineal hygiene. One patient developed early consolidation,
and fractures occurred in the regenerate bone of four humeri in
three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with
achondroplasia and is not just a cosmetic procedure. Cite this article:
We report a new surgical technique for the treatment
of traumatic dislocation of the carpometacarpal (CMC) joint of the
thumb. This is a tenodesis which uses part of the flexor carpi radialis. Between January 2010 and August 2013, 13 patients with traumatic
instability of the CMC joint of the thumb were treated using this
technique. The mean time interval between injury and ligament reconstruction
was 13 days (0 to 42). The mean age of the patients at surgery was
38 years: all were male. At a mean final follow-up of 26 months (24 to 29), no patient
experienced any residual instability. The mean total palmar abduction
of the CMC joint of the thumb was 61° and the mean radial abduction
65° The mean measurements for the uninjured hand were 66° (60° to
73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb
opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths
of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively.
The mean Disabilities of the Arm, Shoulder, and Hand questionnaire
score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained
a mean score of 85 (75 to 95), which included four excellent, seven
good, and two fair results. Our technique offers an alternative method of treating traumatic
dislocation of the CMC joint of the thumb: it produces a stable
joint and acceptable hand function. Cite this article:
We investigated the relationship between a number of patient and management variables and mortality after surgery for fracture of the hip. Data relating to 18 817 patients were obtained from the Scottish Hip Fracture Audit database. We divided variables into two categories, depending on whether they were case-mix (age; gender; fracture type; pre-fracture residence; pre-fracture mobility and ASA scores) or management variables (time from fracture to surgery; time from admission to surgery; grade of surgical and anaesthetic staff undertaking the procedure and anaesthetic technique). Multivariate logistic regression analysis showed that all case-mix variables were strongly associated with post-operative mortality, even when controlling for the effects of the remaining variables. Inclusion of the management variables into the case-mix base regression model provided no significant improvement to the model. Patient case-mix variables have the most significant effect on post-operative mortality and unfortunately such variables cannot be modified by pre-operative medical interventions.
There are few reports of the surgical treatment for late stage Freiburg’s disease with flattening of the metatarsal head and osteoarthritis. We describe the results of the surgical treatment of ten consecutive patients with advanced stage Freiburg’s disease (Smillie’s stage V), using a technique that has not been published previously.
There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a volar locking plate for the treatment of intra-articular
distal radial fractures. In this study we compared the functional
and radiographic outcomes of fluoroscopically and arthroscopically
guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral
unstable intra-articular distal radial fractures were randomised
equally into the two groups for treatment. The mean age of these
74 patients was 64 years (24 to 92). We compared functional outcomes
including active range of movement of the wrist, grip strength and Disabilities
of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic
outcomes that included gap, step, radial inclination, volar angulation
and ulnar variance. There were no significant differences between the techniques
with regard to functional outcomes or radiographic parameters. The
mean gap and step in the fluoroscopic and arthroscopic groups were
comparable at 0.9 mm (standard deviation Arthroscopic reduction conferred no advantage over conventional
fluoroscopic guidance in achieving anatomical reduction of intra-articular
distal radial fractures when using a volar locking plate. Cite this article: