Advertisement for orthosearch.org.uk
Results 61 - 80 of 1307
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 721 - 723
1 Sep 1991
Wright J Treble N Feinstein A

Long radiographs are used to measure lower limb axial alignment, to assess the progression of deformity, and to plan corrective surgery. The purpose of this study was to test the belief that jigs are necessary in order to control limb position for radiography. Above-knee amputated limbs were fixed in different positions of rotation and of knee flexion and radiographed to study the effect on the apparent alignment of the limb. If the limb was rotated no more than 10 degrees from the neutral the effect on apparent axial alignment was minimal and radiographic measurement was reliable. This suggests that standardised positioning jigs are not needed in routine clinical practice


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 999 - 1004
1 Nov 1998
Wilkinson JM Scott BW Clarke AM Bell MJ

The Sheffield Expanding Intramedullary Rod System was developed after experiencing problems with existing rod systems in the management of osteogenesis imperfecta. Between 1986 and 1996 we treated 74 bones in the lower limb in 28 children at a median follow-up of 5.25 years. We have reviewed 24 children with a total of 60 rods. Before surgery, all children had had multiple fractures of the lower limb. At review eight patients had experienced no further fractures, but three had suffered five or more subsequently. Before initial stabilisation, 15 children had never walked, and only three (13%) used walking as their main means of mobility. After surgery, half of those who showed motor arrest were able to walk (p = 0.016). The number of patients able to walk, with or without aids, increased to 17 (p = 0.0001). We have experienced no evidence of epiphyseal damage after the procedure, and complication rates requiring rod exchange have been low (7%)


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 401 - 406
1 Apr 2002
Mittermayer F Windhager R Dominkus M Krepler P Schwameis E Sluga M Kotz R Strasser G

In 251 patients over a period of 15 years an uncemented Kotz modular femoral and tibial reconstruction mega prosthesis was implanted after resection of a malignant tumour of the lower limb. Twenty-one patients (8.4%) underwent revision for aseptic loosening, again using an uncemented prosthesis, and five of these required a further revision procedure. The median follow-up time from the first revision was 60 months (11 to 168) and after a second revision, 33 months (2 to 50). The probability of a patient avoiding aseptic loosening for ten years was 96% for a proximal femoral, 76% for a distal femoral and 85% for a proximal tibial implant. At the time of follow-up all radiographs were assessed according to the International Symposium of Limb Salvage criteria. The first radiological signs of aseptic loosening were always seen at the most proximal or distal part of the anchorage stem at a mean of 12 months (4 to 23) after the first implantation. Using the Musculoskeletal Tumor Society score for evaluation, the clinical results showed a mean of 88% of normal function


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 912 - 917
1 Jul 2020
Tahir M Chaudhry EA Zimri FK Ahmed N Shaikh SA Khan S Choudry UK Aziz A Jamali AR

Aims

It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open wounds. There has been a recent shift in this paradigm towards negative pressure wound therapy (NPWT). The aim of this study was to compare the clinical outcomes in patients with open tibial fractures receiving standard dressing versus NPWT.

Methods

This multicentre randomized controlled trial was approved by the ethical review board of a public sector tertiary care institute. Wounds were graded using Gustilo-Anderson (GA) classification, and patients with GA-II to III-C were included in the study. To be eligible, the patient had to present within 72 hours of the injury. The primary outcome of the study was patient-reported Disability Rating Index (DRI) at 12 months. Secondary outcomes included quality of life assessment using 12-Item Short-Form Health Survey questionnaire (SF-12), wound infection rates at six weeks and nonunion rates at 12 months. Logistic regression analysis and independent-samples t-test were applied for secondary outcomes. Analyses of primary and secondary outcomes were performed using SPSS v. 22.0.1 and p-values of < 0.05 were considered significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 700 - 704
1 Jul 1999
Sochart DH Hardinge K

We have studied the relationship between movements of the foot and ankle and venous blood flow from the lower limb using colourflow Duplex ultrasound to determine the optimum type of exercise for promoting venous return. Studies of both active and passive movements were carried out on 40 limbs in 20 subjects (18 men; 2 women), with a median age of 27 years (20 to 54). We assessed ankle dorsiflexion and plantar flexion, subtalar inversion and eversion, and a combination of all movements. There was no difference in venous flow when comparing opposite limbs in a single subject (p > 0.5), but active exercises produced higher peak and mean velocities of blood flow than passive ones. The active combined movement produced the highest velocities with an increase of 38% in mean and of 58% in peak flow velocities, which were significantly greater than the peak and mean flow rates produced by passive movements. The active combined exercise would therefore be the most effective in eliminating stasis and could contribute to the prevention of deep-vein thrombosis


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 69 - 73
1 Jan 1988
Aldegheri R Trivella G Renzi-Brivio L Tessari G Agostini S Lavini F

We report our experience of lengthening by over 30% a total of 117 lower limbs in achondroplastic patients. We have compared four methods: transverse osteotomy, oblique osteotomy, callotasis of the shaft and chondrodiatasis of the epiphysis. Chrondrodiatasis of the femur and callotasis of the tibia are the techniques which gave fewest complications


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 812 - 815
1 Nov 1989
Bjerregaard P Hagen K Daugaard S Kofoed H

We report 12 patients with infiltrating muscular lipomas of the lower limbs all treated by wide resection. During follow-up averaging seven years, the tumour recurred in five patients. Our results and those reported by others suggest that, in order to avoid recurrence, this tumour, although benign, should be treated by total excision of the muscle or by compartmental resection. Hormonal imbalance was suspected in 9 of the patients but an oestrogen receptor analysis of the histological samples proved negative


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 1 | Pages 19 - 23
1 Jan 1983
Aronstam A Browne R Wassef M Hamad Z

The clinical features, management and outcome of 178 early bleeding episodes into the musculature of the thigh and lower limb of 37 severe haemophiliacs are reported. Ninety-five per cent of all bleeds were treated in under three hours from onset of symptoms and the mean time to complete restoration of function was 3.5 days. The most frequent site of bleeding was the quadriceps (44 per cent) followed by the calf (35 per cent), anterior tibial compartment (seven per cent), adductors of the thigh (seven per cent), hamstrings (six per cent) and sartorius (one per cent). Bleeds of the quadriceps took longest to resolve (mean, four days), significantly longer than bleeds of the calf muscle (3.1 days). The first symptom in 66 per cent of bleeds was pain on movement. When the quadriceps was involved, this rapidly progressed to pain at rest. There was a significant prolongation of recovery time when bleeds of this muscle group were treated more than two hours after the onset of symptoms. Bleeds of the calf muscle required less transfusions and no prolongation in recovery time occurred in bleeds treated up to three hours from the onset of symptoms. The results of this study contrast markedly with earlier reports based on later presentations


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 326 - 331
1 Apr 2000
Gaston P Will E McQueen MM Elton RA Court-Brown CM

We examined the recovery of power in the muscles of the lower limb after fracture of the tibial diaphysis, using a Biodex dynamometer. Recovery in all muscle groups was rapid for 15 to 20 weeks following fracture after which it slowed. Two weeks after fracture the knee flexors and extensors have about 40% of normal power, which rises to 75% to 85% after one year. The dorsiflexors and plantar flexors of the ankle and the invertors and evertors of the subtalar joint are much weaker two weeks after injury, but at one year their mean power is more than that of the knee flexors and extensors. Our findings showed that age, the mode of injury, fracture morphology, the presence of an open wound and the Tscherne grade of closed fractures correlated with muscle power. It is age, however, which mainly determines muscle recovery after fracture of the tibial diaphysis


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 787 - 797
1 Jun 2018
Shuler MS Roskosky M Kinsey T Glaser D Reisman W Ogburn C Yeoman C Wanderman NR Freedman B

Aims

The aim of this study was to evaluate near-infrared spectroscopy (NIRS) as a continuous, non-invasive monitor for acute compartment syndrome (ACS).

Patients and Methods

NIRS sensors were placed on 86 patients with, and 23 without (controls), severe leg injury. NIRS values were recorded for up to 48 hours. Longitudinal data were analyzed using summary and graphical methods, bivariate comparisons, and multivariable multilevel modelling.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 962 - 966
1 Nov 1993
Yadav S

We treated 25 patients with severely deformed and shortened lower limbs by double oblique diaphyseal osteotomy of the short deformed bone, followed by balanced skeletal traction to correct the alignment and increase the length of the limb. The technique is simple and inexpensive and does not require special equipment. It has the advantage of allowing rapid lengthening and secure healing as the overlap allows end-to-end union with no bone gap. The lengthening achieved ranged from 6 to 16 cm. No serious complications were encountered


Bone & Joint Research
Vol. 2, Issue 3 | Pages 58 - 65
1 Mar 2013
Johnson R Jameson SS Sanders RD Sargant NJ Muller SD Meek RMD Reed MR

Objectives

To review the current best surgical practice and detail a multi-disciplinary approach that could further reduce joint replacement infection.

Methods

Review of relevant literature indexed in PubMed.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1267 - 1271
1 Sep 2005
Allami MK Jamil W Fourie B Ashton V Gregg PJ

The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme in order to standardise the collection of information about infections acquired in hospital in the United Kingdom and provide national data with which hospitals could measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by the Center for Disease Control (CDC), should meet at least one of the defined criteria which would confirm the diagnosis and determine the need for specific treatment.

We have assessed the interobserver reliability of the criteria for superficial incisional infection set by the CDC in our current practice. The incisional site of 50 patients who had an elective primary arthroplasty of the hip or knee was evaluated independently by two orthopaedic clinical research fellows and two orthopaedic ward sisters for the presence or absence of surgical-site infection. Interobserver reliability was assessed by comparison of the criteria for wound infection used by the four observers using kappa reliability coefficients. Our study demonstrated that some of the components of the current CDC criteria were unreliable and we recommend their revision.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 312 - 316
1 Mar 1999
Wade RH New AMR Tselentakis G Kuiper JH Roberts A Richardson JB

Nomograms derived from mathematical analysis indicate that the level of malunion is the most important determinant of changes in the moment arm of the knee, the plane of the ankle and alterations in limb length. Testing in five patients undergoing reconstruction showed a mean error of postoperative limb length of 2.2 mm (sd 0.8 mm), knee moment arm of 4.7 mm (sd 3.3 mm) and ankle angle of 2.6° (sd 2.3°). These nomograms provide the information required when assessing whether a particular degree of angulation may be accepted.


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 788 - 789
1 Nov 1969
Lamb W


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 4 | Pages 731 - 747
1 Nov 1967
Sharrard WJW

1. The nature of paralytic deformity arising in poliomyelitis, cerebral palsy and spina bifida is considered and three types of deformity–acute contracture, postural contracture and deformity from muscle imbalance are described.

2. The place of physiotherapy, splintage and surgery in the management of these varieties of paralytic deformity is discussed and the overall results of treatment are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 512 - 512
1 May 1997


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 123 - 129
1 Jan 2010
Jameson SS Bottle A Malviya A Muller SD Reed MR

The National Institute for Clinical Excellence (NICE) produces recommendations on appropriate treatment within the National Health Service (NHS) in England and Wales. The NICE guidelines on prophylaxis for venous thromboembolism in orthopaedic surgery recommend that all patients be offered a low molecular weight heparin (LMWH). The linked hospital episode statistics of 219 602 patients were examined to determine the rates of complications following lower limb arthroplasty for the 12-month periods prior to and following the publication of these guidelines. These were compared with data from the National Joint Registry (England and Wales) regarding the use of LMWH during the same periods. There was a significant increase in the reported use of LMWH (59.5% to 67.6%, p < 0.001) following the publication of the guidelines. However, the 90-day venous thromboembolism events actually increased slightly following total hip replacement (THR, 1.69% to 1.84%, p = 0.06) and remained unchanged following total knee replacement (TKR, 1.99% to 2.04%). Return to theatre in the first 30 days for infection did not show significant changes. There was an increase in the number of patients diagnosed with thrombocytopenia, which was significant following THR (0.11% to 0.16%, p = 0.04). The recommendations from NICE are based on predicted reductions in venous thromboembolism events, reducing morbidity, mortality and costs to the NHS.

The early results in orthopaedic patients do not support these predictions, but do show an increase in complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 747 - 747
1 May 2010
MCNALLY MA