Advertisement for orthosearch.org.uk
Results 761 - 780 of 804
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 777 - 780
1 Jun 2010
Contreras MEK Dani WS Endges WK De Araujo LCT Berral FJ

We undertook a prospective pilot study to determine whether arthroscopic surgery through the central compartment of the hip was effective in the management of a snapping iliopsoas tendon. Seven patients were assessed pre-operatively and at three, six, 12 and 24 months after operation. This included the assessment of pain on a visual analogue scale (VAS) and function using the modified Harris hip score.

All the patients had resolution of snapping post-operatively and this persisted at follow-up at two years. The mean VAS score for pain fell from 7.7 (6 to 10) pre-operatively to 4.3 (0 to 10) by three months (p = 0.051), and to 3.6 (1 to 8) (p = 0.015), 2.4 (0 to 8) (p = 0.011) and 2.4 (0 to 8) (p = 0.011) by six, 12 and 24 months, respectively. The mean modified Harris hip score increased from 56.1 (13.2 to 84.7) pre-operatively to 88.4 (57.2 to 100) at one year (p = 0.018) and to 87.9 (49.5 to 100) at two years (p = 0.02). There were no complications and no weakness occurred in the musculature around the hip.

Our findings suggest that this treatment is effective and would support the undertaking of a larger study comparing this procedure with other methods of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 827 - 832
1 Jul 2008
Rees JL

This review discusses the pathogenesis and surgical treatment of tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1186 - 1192
1 Sep 2008
Lyu S

The outcome of arthroscopic medial release of 255 knees in 173 patients for varying grades of osteoarthritis involving the medial compartment is reported. All operations were performed by a single surgeon between January 2001 and May 2003. The Knee Society score for pain and the patient’s subjective satisfaction were used for the outcome evaluation. Overall, satisfactory outcome was reported for 197 knees (77.3%) and the mean Knee Society score for pain improved from 17.6 (95% confidence interval, 16.7 to 18.5), pre-operatively to 39.4 (95% confidence interval, 37.9 to 41.1) (p < 0.001). There were minor manageable complications of persistent effusion in 16 knees and prolonged wound discomfort in 11. In total, 15 of the 21 knees with poor results were converted to total knee replacements and two other patients (three knees) were offered this option after a mean period of 16 months. Based on these observations arthroscopic medial release is an effective treatment for osteoarthritis of the medial compartment of the knee joint and can be expected to reduce the pain in the majority of patients for at least four years post-operatively


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 738 - 744
1 Jun 2008
Pang H Lo N Yang K Chong H Yeo S

We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar knee replacement. We randomised 90 patients into two equal groups. The study group received an injection of triamcinolone acetonide, bupivacaine, and epinephrine into the peri-articular tissues at the end of the operation. The control group received the same injection mixture but without the addition of triamcinolone. The peri-operative analgesic regimen was standardised.

The study group reported a significant reduction in pain (p = 0.014 at 12 hours, p = 0.031 at 18 hours and p = 0.031 at 24 hours) and had a better range of movement (p = 0.023 at three months). There was no significant difference in the rate of infection and no incidence of tendon rupture in either group.

The addition of corticosteroid to the peri-articular injection after unicondylar knee replacement had both immediate and short-term benefits in terms of relief from pain, and rehabilitation with no increased risk of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1462 - 1465
1 Nov 2007
Roberts VI Mereddy PKR Donnachie NJ Hakkalamani S

The emergence of minimally-invasive total knee replacement (TKR) has led to the refinement of several surgical approaches, including the quadriceps-sparing and sub-vastus. There is some disagreement as to the precise definition of the term ‘minimally-invasive’, especially in regard to the preservation of vastus medialis obliquus (VMO). It is known that the termination of VMO is variable and may make these approaches difficult. We have attempted to assess the factors influencing the insertion of VMO and the impact which they have on the approach for TKR.

The MR scans of 198 knees were examined to assess the variation in the insertion of VMO in relation to the patella and the effect of variables such as age, gender and the presence of concurrent osteoarthritis of the knee on the insertion.

Our findings showed that both age and the presence of osteoarthritis were contributing factors to changes in the level of insertion of VMO. Therefore, not all capsular incisions which extend proximal to the midpole of the patella will violate the quadriceps tendon.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1214 - 1221
1 Sep 2008
Egol K Walsh M Tejwani N McLaurin T Wynn C Paksima N

We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable fractures of the distal radius. A total of 280 consecutive patients were enrolled in a prospective database and 88 identified who met the inclusion criteria for surgery. They were randomised to receive either bridging external fixation with supplementary Kirschner-wire fixation or volar-locked plating with screws. Both groups were similar in terms of age, gender, hand dominance, fracture pattern, socio-economic status and medical co-morbidities.

Although the patients treated by volar plating had a statistically significant early improvement in the range of movement of the wrist, this advantage diminished with time and in absolute terms the difference in range of movement was clinically unimportant. Radiologically, there were no clinically significant differences in the reductions, although more patients with AO/OTA (Orthopaedic Trauma Association) type C fractures were allocated to the external fixation group. The function at one year was similar in the two groups.

No clear advantage could be demonstrated with either treatment but fewer re-operations were required in the external fixation group.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 23 - 26
1 Jan 2008
Okano K Enomoto H Osaki M Shindo H

We evaluated the results of rotational acetabular osteotomy in 44 hips (42 patients) with advanced osteoarthritis secondary to developmental dysplasia. The mean age of the patients at surgery was 43.4 years (30 to 59) and the mean follow-up was 12.1 years (8 to 19).

The mean Merle d’Aubigné clinical score improved from 10.8 points (8 to 15) pre-operatively to 13.5 points (6 to 18) at follow-up. Radiologically, this procedure produced adequate improvement regarding cover of the femoral head. At follow-up, the osteoarthritic stage assessed using the Japanese Orthopaedic Association grading, was improved in 11 hips (25%), unchanged in 22 (50%) and had progressed in 11 (25%). The mean pre-operative roundness index of the femoral head was significantly different in the 33 hips which had improved or maintained their osteoarthritic stage compared with the 11 which had progressed (53.7% vs 63.7%; p < 0.001).

Osteoarthritis with a round femoral head is considered to be an indication for rotational acetabular osteotomy, even in advanced stages of the disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 925 - 927
1 Jul 2007
Jackson WFM Tryfonidis M Cooke PH Sharp RJ

Correction of valgus deformity of the hindfoot using a medial approach for a triple fusion has only recently been described for patients with tight lateral soft tissues which would be compromised using the traditional lateral approach. We present a series of eight patients with fixed valgus deformity of the hindfoot who had correction by hindfoot fusion using this approach.

In addition, we further extended the indications to allow concomitant ankle fusion. The medial approach allowed us to excise medial ulcers caused by the prominent medial bony structures, giving simultaneous correction of the deformity and successful internal fixation.

We had no problems with primary wound healing and experienced no subsequent infection or wound breakdown. From a mean fixed valgus deformity of 58.8° (45° to 66°) pre-operatively, we achieved a mean post-operative valgus angulation of 13.6° (7° to 23°). All the feet were subsequently accommodated in shoes. The mean time to arthrodesis was 5.25 months (3 to 9).

We therefore recommend the medial approach for the correction of severe fixed valgus hindfoot deformities.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 343 - 348
1 Mar 2008
Prasad N Dent C

We analysed the outcome of the Coonrad-Morrey total elbow replacement used for fracture of the distal humerus in elderly patients with no evidence of inflammatory arthritis and compared the results for early versus delayed treatment. We studied a total of 32 patients with 15 in the early treatment group and 17 in the delayed treatment group. The mean follow-up was 56.1 months (18 to 88). The percentage of excellent to good results based on the Mayo elbow performance score was not significantly different, 84% in the early group and 79% in the delayed group. Subjective satisfaction was 92% in both the groups.

One patient in the early group developed chronic regional pain syndrome and another type 4 aseptic loosening. Two elbows in the early group also showed type 1 radiological loosening.

Two patients in the delayed group had an infection, two an ulnar nerve palsy, one developed heterotopic ossification and one type 4 aseptic loosening. Two elbows in this group also showed type 1 radiological loosening. The Kaplan-Meier survivorship analysis for the early and delayed treatment groups was 93% at 88 months and 76% at 84 months, respectively.

No significant difference was found between the two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation.

Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 615 - 619
1 May 2007
Smith R Wood PLR

A consecutive series of 23 patients (25 ankles) with osteoarthritis of the ankle and severe varus or valgus deformity were treated by open arthrodesis using compression screws. Primary union was achieved in 24 ankles one required further surgery to obtain a solid fusion. The high level of satisfaction in this group of patients reinforces the view that open arthrodesis, as opposed to ankle replacement or arthroscopic arthrodesis, continues to be the treatment of choice when there is severe varus or valgus deformity associated with the arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1031 - 1035
1 Aug 2007
Dora C Houweling M Koch P Sierra RJ

We have reviewed a group of patients with iliopsoas impingement after total hip replacement with radiological evidence of a well-fixed malpositioned or oversized acetabular component. A consecutive series of 29 patients (30 hips) was assessed. All had undergone a trial of conservative management with no improvement in their symptoms. Eight patients (eight hips) preferred continued conservative management (group 1), and 22 hips had either an iliopsoas tenotomy (group 2) or revision of the acetabular component and debridement of the tendon (group 3), based on clinical and radiological findings. Patients were followed clinically for at least two years, and 19 of the 22 patients (86.4%) who had surgery were contacted by phone at a mean of 7.8 years (5 to 9) post-operatively. Conservative management failed in all eight hips. At the final follow-up, operative treatment resulted in relief of pain in 18 of 22 hips (81.8%), with one hip in group 2 and three in group 3 with continuing symptoms. The Harris Hip Score was significantly better in the combined groups 2 and 3 than in group 1. There was a significant rate of complications in group 3. This group initially had better functional scores, but at final follow-up these were no different from those in group 2.

Tenotomy of the iliopsoas and revision of the acetabular component are both successful surgical options. Iliopsoas tenotomy provided the same functional results as revision of the acetabular component and avoided the risks of the latter procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 604 - 608
1 May 2007
Park KK Chang CB Kang YG Seong SC Kim TK

This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year postoperatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1° (60° to 160°) to 133.0° (105° to 150°). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120°, we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9 vs 47.3, p = 0.031). Knees with a maximum flexion of more than 135° had a better functional Western Ontario McMasters Universities Osteoarthritis index score than knees with maximum flexion of 135° or less (17.5 vs 14.3, p = 0.031). We found only weak correlation between the postoperative maximum flexion and the clinical parameters for pain relief, function and quality of life, even in Korean patients. Efforts to increase post-operative maximum flexion should be exercised with caution until concerns relating to high-flexion activities are sufficiently resolved.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 516 - 520
1 Apr 2007
Bufquin T Hersan A Hubert L Massin P

We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58).

The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 471 - 476
1 Apr 2007
Kim Y Kim J Yoon S

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3).

The operating and tourniquet times were significantly longer in the navigation group (p < 0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920).

In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 662 - 665
1 May 2009
Brinker MR Loncarich DP Melissinos EG O’Connor DP

We report a case in which Ilizarov distraction osteogenesis was used to lengthen the portion of calcaneum that remained after a radical debridement for osteomyelitis. The patient was able to walk normally in unmodified shoes at the end of his treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 925 - 927
1 Jul 2006
Kalra KP Dhar SB Shetty G Dhariwal Q

We studied 15 patients with healed tuberculosis of the spine and a resultant kyphosis. We selected only those with no neurological deficit and performed a wedge resection of the vertebra using a transpedicular approach. The wedge was removed from the apex of the deformity. For those with a neurological deficit, we chose the conventional anterior debridement and decompression with 360° circumferential fusion. At a mean follow-up of 26.8 months (8 to 46) the outcome was good with an increase in the mean Oswestry Disability Index from 56.26 (48 to 62) pre-operatively to 11.2 (6 to 16) at the latest follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1448 - 1453
1 Nov 2006
Chen AF Alan RK Redziniak DE Tria AJ

The aim of this study was to compare the results in patients having a quadriceps sparing total knee replacement (TKR) with those undergoing a standard TKR at a minimum follow-up of two years.

All patients who had a TKR with a high-flex posterior-stabilised prosthesis prior to December 2002 were reviewed retrospectively. There were 57 patients available for follow-up. Those with a quadriceps sparing TKR had less pain peri-operatively with a greater degree of flexion at all the post-operative visits and at the final follow-up, but their operations took longer, with less accurate radiological alignment. There was no difference in the complications and in the Knee Society scores between the two groups at the final follow-up.

Total knee replacement through a quadriceps sparing approach has some peri-operative advantages over the standard incision. At a minimum follow-up of two years the clinical results were similar to those with a standard incision, but the radiological outcomes of the quadriceps sparing group were inferior.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1321 - 1326
1 Oct 2006
Amin AK Clayton RAE Patton JT Gaston M Cook RE Brenkel IJ

The results of 41 consecutive total knee replacements performed on morbidly obese patients with a body mass index > 40 kg/m2, were compared with a matched group of 41 similar procedures carried out in non-obese patients (body mass index < 30 kg/m2). The groups were matched for age, gender, diagnosis, type of prosthesis, laterality and pre-operative Knee Society Score. We prospectively followed up the patients for a mean of 38.5 months (6 to 66). No patients were lost to follow-up. At less than four years after operation, the results were worse in the morbidly obese group compared with the non-obese, as demonstrated by inferior Knee Society Scores (mean knee score 85.7 and 90.5 respectively, p = 0.08; mean function score 75.6 and 83.4, p = 0.01), a higher incidence of radiolucent lines on post-operative radiographs (29% and 7%, respectively, p = 0.02), a higher rate of complications (32% and 0%, respectively, p = 0.001) and inferior survivorship using revision and pain as end-points (72.3% and 97.6%, respectively, p = 0.02).

Patients with a body mass index > 40 kg/m2 should be advised to lose weight prior to total knee replacement and to maintain weight reduction. They should also be counselled regarding the inferior results which may occur if they do not lose weight before surgery.