header advert
Results 701 - 720 of 1321
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 988 - 995
1 Sep 2001
Porter DE Benson MK Hosney GA

We defined the characteristics of dysplasia and coxa valga in hereditary multiple exostoses (HME) by radiological analysis of 24 hips in 12 patients. The degree and effect of the ‘osteochondroma load’ around the hip were quantified. We investigated the pathology of the labrum and the incidence of osteoarthritis and of malignant change in these patients. Coxa valga and dysplasia were common with a median neck-shaft angle of 156°, a median centre-edge angle of 23° and Sharp’s acetabular angle of 44°. There was overgrowth of the femoral neck with a significantly greater ratio of the neck/shaft diameter in HME than in the control hips (p < 0.05), as well as correlations between the proximal femoral and pelvic osteochondroma load (p < 0.05) and between the proximal femoral osteochondroma load and coxa valga (p < 0.01). Periacetabular osteochondromas are related to Sharp’s angle as an index of dysplasia (p < 0.05), but not coxa valga. No correlation was found between dysplasia and coxa valga. These data suggest that HME may cause anomalies of the hip as a reflection of a generalised inherited defect, but also support the theory that osteochondromas may themselves precipitate some of the characteristic features of HME around the hip


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1264 - 1269
1 Oct 2018
Thomas AM Simmons MJ

Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates.

In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates.

Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres.

Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection.

There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice.

Cite this article: Bone Joint J 2018;100-B:1264–9.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 37 - 39
1 Feb 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 165 - 174
1 Feb 1969
Rösingh GE James J

1. An investigation was made of the tolerance of the cells in the femoral head in rabbits for ischaemia brought about by transecting the ligament of the femoral head and applying a ligature around the femoral neck. The animals were killed two, six, twelve, twenty-four and seventy-two hours after operation. 2. In the cells of the bone marrow and in the osteoblasts distinct histological signs of disintegration were present six hours after operation. Pyknosis of the osteocyte nuclei was found after twenty-four hours' ischaemia; sometimes vacuolar clarifications could be observed in these pyknotic nuclei. After three days of ischaemia the staining affinity for Feulgen and haematoxylin of a number of osteocyte nuclei had visibly decreased. 3. The Feulgen-DNA content of the osteocyte nuclei-as measured in individual nuclei by means of an integrated microdensitometer-was significantly reduced as compared with similar nuclei from the control side as early as after six hours of ischaemia. This DNA loss was progressive with the period of ischaemia. From these facts, the conclusion was reached that in the femoral head of the rabbit the period of reversible damage for osteocytes must have ended within six hours


Bone & Joint Research
Vol. 7, Issue 7 | Pages 468 - 475
1 Jul 2018
He Q Sun H Shu L Zhu Y Xie X Zhan Y Luo C

Objectives

Researchers continue to seek easier ways to evaluate the quality of bone and screen for osteoporosis and osteopenia. Until recently, radiographic images of various parts of the body, except the distal femur, have been reappraised in the light of dual-energy X-ray absorptiometry (DXA) findings. The incidence of osteoporotic fractures around the knee joint in the elderly continues to increase. The aim of this study was to propose two new radiographic parameters of the distal femur for the assessment of bone quality.

Methods

Anteroposterior radiographs of the knee and bone mineral density (BMD) and T-scores from DXA scans of 361 healthy patients were prospectively analyzed. The mean cortical bone thickness (CBTavg) and the distal femoral cortex index (DFCI) were the two parameters that were proposed and measured. Intra- and interobserver reliabilities were assessed. Correlations between the BMD and T-score and these parameters were investigated and their value in the diagnosis of osteoporosis and osteopenia was evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1067 - 1072
1 Nov 1998
Hall RM Siney P Wroblewski BM Unsworth A

The direction of wear in the acetabular socket has implications for the amount of debris that is generated during movement, for the magnitude of eccentric loading and for the incidence of impingement of the neck. We observed the direction of penetration with respect to a global co-ordinate system in 84 acetabular components retrieved at reoperation. The mean direction of wear relative to the open face of the sockets was found to be 37° with a range from 0° to 87°. For those values determined using the inclination of the socket on the prerevision radiograph, the mean direction of penetration in the coronal plane had a lateral, rather than a medial, component. The mean angle was 84° (SD 17°) with respect to the horizontal. The angle of penetration was found to correlate significantly with the depth, in that the lateral component became larger as the wear progressed. There was also a significant correlation between the rate of penetration and the direction of wear. Despite the theoretical advantage of penetration in the superolateral direction, i.e., along the margin of the socket, in reducing the probability of impingement of the neck, no significant correlation was seen between the angle of penetration and the period of use in vivo. This may suggest that impingement of the femoral neck on the rim of the socket may not be the dominant factor in loosening of the socket but can still be important in a few cases


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 414 - 418
1 Apr 2001
Clark DI Ahmed AB Baxendale BR Moran CG

In a prospective, controlled study, we measured the effect on cardiac output of the introduction of methylmethacrylate during hemiarthroplasty for displaced fractures of the femoral neck. We treated 20 elderly patients who were similar in age, height, weight and preoperative left ventricular function with either cemented or uncemented hemiarthroplasty. Using a transoesophageal Doppler probe, we measured cardiac output before incision and at six stages of the procedure: during the surgical approach, reaming and lavage of the femoral canal, the introduction of cement, the insertion of the prosthesis, and in reduction and closure. We found that before the cement was introduced, there was no difference in stroke volume or cardiac output (p > 0.25). Cementation produced a transient but significant reduction in cardiac output of 33% (p < 0.01) and a reduction in stroke volume of 44% (p < 0.02). The introduction of cement did not affect the heart rate or mean arterial pressure. There was no significant difference in cardiac function on insertion of the prosthesis. Standard non-invasive haemodynamic monitoring did not detect the cardiovascular changes which may account for the sudden deaths that sometimes occur during cemented hemiarthroplasty. The fall in stroke volume and cardiac output may be caused by embolism occurring during cementation, but there was no similar fall during reaming or insertion of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 305 - 309
1 Mar 1985
Pini M Spadini E Carluccio L Giovanardi C Magnani E Ugolotti U Uggeri E

In a randomised trial we compared the effects of two different antithrombotic regimens on the incidence of venographically established deep venous thrombosis (DVT) in 83 patients undergoing surgery for fracture of the femoral neck. Group A received dextran 40 peroperatively plus 0.5 g aspirin a day beginning before operation and continuing for 10 days after. Group B received heparin calcium 5000 iu subcutaneously plus dihydroergotamine (DHE) 0.5 mg intramuscularly, given 8-hourly, beginning before operation and continuing for 10 days after. Two patients in Group A and three in Group B developed proximal DVT, while the incidence of all DVT was 33% in Group A and 29% in Group B, a difference which was not significant. Haemorrhagic complications were much more common in the dextran/aspirin group: the volume of drainage fluid, the number of patients transfused and quantity of blood transfused, and the drop in haemoglobin level were all significantly greater in Group A. We conclude that the DHE/heparin regime is preferable to dextran/aspirin because it is safer and no less effective


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 405 - 411
1 Aug 1983
Freeman M Bradley G

Clinical experience of the ICLH method of resurfacing the hip now spans 10 years. The first 36 arthroplasties, performed between 1972 and 1974, have been previously reported. This review covers in detail 204 such arthroplasties performed between 1975 and 1979 using a standard operative technique and prosthesis; these hips were consecutive and entirely unselected. Follow-up averaged 3.2 years (range two to six years). Successful hips are comparable to hips successfully replaced with stemmed prostheses. The rates of perioperative complications and failure due to infection, ectopic ossification, fracture of the femoral neck, and dislocation are favourably comparable to rates reported for stemmed total hip arthroplasties. The rate of aseptic loosening (17 per cent) greatly exceeded that found for stemmed total hip arthroplasties. Errors of patient selection, operative technique and prosthetic design have been identified. It is concluded that, although resurfacing arthroplasty of the hip may be an appealing procedure with theoretical advantages in certain instances, patient selection is essential, operative technique is demanding and changes in the design of the prosthesis are required. The procedure is still in evolution and therefore it should not yet be generally employed


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 303 - 310
1 Mar 2019
Kim S Lim Y Kwon S Jo W Heu J Kim Y

Aims

The purpose of this study was to examine whether leg-length discrepancy (LLD) following unilateral total hip arthroplasty (THA) affects the incidence of contralateral head collapse and subsequent THA in patients with bilateral osteonecrosis, and to determine factors associated with subsequent collapse.

Patients and Methods

We identified 121 patients with bilateral non-traumatic osteonecrosis who underwent THA between 2003 and 2011 to treat a symptomatic hip, and who also exhibited medium-to-large lesions (necrotic area ≥ 30%) in an otherwise asymptomatic non-operated hip. Of the 121 patients, 71 were male (59%) and 50 were female (41%), with a mean age of 51 years (19 to 71) at the time of initial THA. All patients were followed for at least five years and were assessed according to the presence of a LLD (non-LLD vs LLD group), as well as the LLD type (longer non-operated side vs shorter non-operated side group).


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 3 | Pages 462 - 470
1 Aug 1963
Fernandez de Valderrama JA

1. The term "observation hip" refers to a form of hip disease affecting children and adolescents, the most significant features being the transient nature of the symptoms and the absence of a bony or cartilaginous lesion on radiographic examination. 2. With a view to determining the possible sequelae of the disorder, twenty-three patients aged between two and fifteen years at the onset of the condition were studied fifteen to thirty years later. 3. Varying degrees of coxa magna, osteoarthritis or simple broadening of the femoral neck in the "observed" hip joint were found in the radiographs of twelve of the twenty-three patients studied. 4. This analysis suggests that the " observation hip" syndrome is the result ofan inflammatory process ofthejoint due to varied etiology, whether from injury or infection. The developmental and degenerative changes which may occur are a consequence of hypervascularisation of the bone. Thus changes may develop without necessarily producing the epiphysial necrosis characteristic of the first stage of ischaemia in Legg-Calvé-Perthes' disease. 5. The persistence of this stage of hypervascularity, and therefore the possible outcome of the transient synovitis, may be conditioned by the age at onset of the pathological process, the severity of the condition, and the duration of the symptoms and signs


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 190 - 203
1 May 1949
Evans EM

1. Trochanteric fractures are classified, with special emphasis on the stability or instability of the fracture. The importance of the cortical buttress of bone on the inner side of the femoral neck and shaft is stressed. 2. Three series of cases are presented: a) one hundred and one cases treated conservatively in hospital; b) twenty-five cases sent home by reason of lack of hospital beds; c) twenty-two cases treated by fixation with a Capener-Neufeld nail-plate. 3. From consideration of these three series, and from study of similar series of cases reported in the literature, it is suggested that routine operative treatment of trochanteric fractures has the advantages of greater comfort and mobility of the patient, lowered mortality, and economy of hospital beds. 4. Certain features of the operation of internal fixation by the Capener-Neufeld nail-plate are discussed. A director, for more efficient insertion of the nail-plate, is described. 5. The importance of early mobility after operation is emphasized. Only a small proportion of Patients can be allowed early weight-bearing but almost all can be got up in a chair, and most can be taught to get about with crutches, without weight-bearing on the fractured limb, within a few days of operation


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 853 - 861
1 Jul 2018
Leunig M Hutmacher JE Ricciardi BF Impellizzeri FM Rüdiger HA Naal FD

Aims

The classical longitudinal incision used for the direct anterior approach (DAA) to the hip does not follow the tension lines of the skin and can lead to impaired wound healing and poor cosmesis. The purpose of this retrospective study was to determine the satisfaction with the scar, and functional and radiographic outcomes comparing the classic longitudinal incision with a modified skin crease ‘bikini’ when the DAA is used for total hip arthroplasty (THA).

Patients and Methods

A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’) completed a follow-up questionnaire between two and four years postoperatively, including the Oxford Hip Score (OHS), the University of North Carolina ‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic appearance of the scar and symptoms of numbness. The positioning of the components, rates of heterotopic ossification (HO) and rates of revision were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 209 - 213
1 May 1981
Wientroub S Boyde A Chrispin A Lloyd-Roberts G

Stereoradiography with a base shift of the source of illumination was used to produce pairs of radiographs to be measured by stereophotogrammetric techniques. The direction of shift was parallel with the longitudinal axis of the body, so that each radiograph in the stereopair could be used for other clinical purposes. A base shift of 10 centimetres with a distance of 100 centimetres between the focus and the film gave acceptable value of stereoscopic parallax. The radiographs were measured using a Hilger and Watts medical stereometer. This method was checked with test specimens, namely an osteotomised pelvis in which one acetabulum could be rotated and an osteotomised femur in which the whole upper portion could be rotated against the shaft. Measurements made on the acetabulum and its radiographs showed a correlation coefficient of 0.9838 over the range 0 to 30 degrees of anteversion, with a mean error +2.54 degrees and a standard deviation of +/- 1.52 degrees (n = 21). For the femoral neck, over the range from 10 degrees of retroversion to 80 degrees of anteversion, the correlation coefficient was 0.9979, the mean error +2.46 and the standard deviation +/- 1.48 degrees (n = 30)


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 61 - 65
1 Feb 1978
Hosking D

Osteomalacia may be a contributory factor in some patients in the development of fractures of the femoral neck and complicate the subsequent management. The level of serum alkaline phosphatase is often valuable in the diagnosis of metabolic bone disease but rises after any uncomplicated fracture, and since such a rise may limit the diagnostic usefulness of this measurement in detecting osteomalacia its extent was assessed in 106 patients. In the majority serum levels were normal on admission, rising after seven to nine days to reach a maximum within a month after fracture. Elevated levels on admission were found in patients with osteomalacia, liver damage or where there had been a delay of several weeks between injury and admission. In a small number of patients normal levels on admission subsequently reached very high values, usually in association with comminution or instability of the fracture. Elevated levels persisted for six to twelve weeks after fracture, the major influence upon the level at this time being the maximum value achieved rather than the presence of osteomalacia. If patients are to be screened for osteomalacia, the alkaline phosphatase must be measured within the first week after a fracture to avoid the distorting influences of the fracture itself


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 551 - 562
1 Aug 1969
Rösingh GE Steendijk R Van den Hooff A Oosterhoff J

1. In two-month-old rabbits the femoral heads were made necrotic by transecting the ligament of the femoral head and applying a ligature around the femoral neck. The animals were killed at different periods, from six hours to twenty-one weeks after the operation. The changes in the femoral heads were studied histologically, microradiographically and radiographically. 2. In the first three weeks the necrotic bone marrow was penetrated by granulation tissue in which cellular differentiation gradually developed. Subsequently large quantities of new bone were deposited on the dead trabeculae. This led to an increase in the bone volume at the expense of the marrow volume; this increase coincided with an increase in the radiographic density (sclerosis) of the femoral head. The new bone tissue was attached to the necrotic trabeculae by a specific cement line and showed the features of woven bone. At a later stage lamellar bone was deposited. From six weeks on a normal bone-marrow ratio was gradually restored with concomitant radiographic loss of sclerosis. 3. It is suggested that mechanical weakening of the femoral head is the consequence of this late post-operative restoration of the normal pre-operative bone-to-marrow ratio, the new bone trabeculae being mechanically inferior because of the presence of woven bone and cement lines. This weakness may initiate collapse and deformation of the revascularised femoral head


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 170 - 177
1 Feb 2019
Puri A Gulia A Hegde P Verma V Rekhi B

Aims

The aims of this study were to evaluate the efficacy of preoperative denosumab in achieving prospectively decided intention of therapy in operable giant cell tumour of bone (GCTB) patients, and to document local recurrence-free survival (LRFS).

Patients and Methods

A total of 44 patients received preoperative denosumab: 22 to facilitate curettage, 16 to facilitate resection, and six with intent of converting resection to curettage. There were 26 male and 18 female patients. The mean age was 27 years (13 to 47).


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 842 - 845
1 Aug 2000
Wroblewski BM Siney PD Fleming PA Bobak P

The calcar femorale is a vertical plate of bone lying deep to the lesser trochanter and is formed as a result of traction of the iliopsoas which separates the femoral cortex into two distinct layers, the calcar femorale and the medial femoral cortex. They fuse together proximally to form the medial femoral neck. A stem placed centrally will abut against the calcar femorale with little or no space for cement. Clearing of the calcar will offer space for a cement layer, which will support the stem proximally on the posterior aspect. We compared two consecutive groups of Charnley low-friction arthroplasties, with and without clearing of the calcar. In 330 patients who had an arthroplasty without clearing the calcar, there were ten revisions for aseptic loosening of the stem and six other stems were considered ‘definitely loose’, giving a rate of failure of 4.8%. In 111 patients in whom the calcar was cleared there was only one revision for aseptic loosening and no stems were classed as ‘definitely loose’, giving a rate of failure of 0.9%. Survivorship analysis has again shown the need for long-term follow-up; the differences became clear after ten years but because of the relatively small numbers, statistical analysis is not yet applicable. We now clear the calcar femorale routinely and advocate optimal access to the medullary canal and insertion of the stem in the area of the piriform fossa


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 3 | Pages 576 - 589
1 Aug 1961
Garden RS

Many analyses of the geometric arrangement of trabeculae in the proximal end of the femur have accepted and perpetuated the theories of Ward (1838), Culmann (1866) and Meyer (1867), and have contributed to the belief that the structure of the femoral neck embodies mechanical principles which are foreign to bony formations elsewhere. This isolated departure from the normal pattern of skeletal behaviour is considered to be most unlikely, and an attempt has been made to show that the structure of the femoral head and neck departs but little from the normal anatomy of the long bone. From a developmental point of view, the proximal end of the human femur is believed, in its simplest interpretation, to represent an upward continuation of the original shaft which has undergone rotation and expansion. The cancellous arrangements of the internal weight-bearing system are likewise believed to represent the expanded and rotated lamellae of the neck as they are presented radiologically or on coronal section. The forces acting upon the proximal end of the femur are considered to be mainly compressive in nature, and both crane and street-lamp bracket theories have therefore been rejected. The spiral conformity of the proximal end of the femur has been related to the spiral disposition of the soft-tissue structures that surround the hip, and in the interpretation of hip joint mechanics the principle of the screw has been preferred to the principle ofthe lever


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 679 - 683
1 Jul 2000
Gautier E Ganz K Krügel N Gill T Ganz R

The primary source for the blood supply of the head of the femur is the deep branch of the medial femoral circumflex artery (MFCA). In posterior approaches to the hip and pelvis the short external rotators are often divided. This can damage the deep branch and interfere with perfusion of the head. We describe the anatomy of the MFCA and its branches based on dissections of 24 cadaver hips after injection of neoprene-latex into the femoral or internal iliac arteries. The course of the deep branch of the MFCA was constant in its extracapsular segment. In all cases there was a trochanteric branch at the proximal border of quadratus femoris spreading on to the lateral aspect of the greater trochanter. This branch marks the level of the tendon of obturator externus, which is crossed posteriorly by the deep branch of the MFCA. As the deep branch travels superiorly, it crosses anterior to the conjoint tendon of gemellus inferior, obturator internus and gemellus superior. It then perforates the joint capsule at the level of gemellus superior. In its intracapsular segment it runs along the posterosuperior aspect of the neck of the femur dividing into two to four subsynovial retinacular vessels. We demonstrated that obturator externus protected the deep branch of the MFCA from being disrupted or stretched during dislocation of the hip in any direction after serial release of all other soft-tissue attachments of the proximal femur, including a complete circumferential capsulotomy. Precise knowledge of the extracapsular anatomy of the MFCA and its surrounding structures will help to avoid iatrogenic avascular necrosis of the head of the femur in reconstructive surgery of the hip and fixation of acetabular fractures through the posterior approach