Advertisement for orthosearch.org.uk
Results 681 - 700 of 6223
Results per page:
Bone & Joint Open
Vol. 3, Issue 12 | Pages 977 - 990
23 Dec 2022
Latijnhouwers D Pedersen A Kristiansen E Cannegieter S Schreurs BW van den Hout W Nelissen R Gademan M

Aims. This study aimed to investigate the estimated change in primary and revision arthroplasty rate in the Netherlands and Denmark for hips, knees, and shoulders during the COVID-19 pandemic in 2020 (COVID-period). Additional points of focus included the comparison of patient characteristics and hospital type (2019 vs COVID-period), and the estimated loss of quality-adjusted life years (QALYs) and impact on waiting lists. Methods. All hip, knee, and shoulder arthroplasties (2014 to 2020) from the Dutch Arthroplasty Register, and hip and knee arthroplasties from the Danish Hip and Knee Arthroplasty Registries, were included. The expected number of arthroplasties per month in 2020 was estimated using Poisson regression, taking into account changes in age and sex distribution of the general Dutch/Danish population over time, calculating observed/expected (O/E) ratios. Country-specific proportions of patient characteristics and hospital type were calculated per indication category (osteoarthritis/other elective/acute). Waiting list outcomes including QALYs were estimated by modelling virtual waiting lists including 0%, 5% and 10% extra capacity. Results. During COVID-period, fewer arthroplasties were performed than expected (Netherlands: 20%; Denmark: 5%), with the lowest O/E in April. In the Netherlands, more acute indications were prioritized, resulting in more American Society of Anesthesiologists grade III to IV patients receiving surgery. In both countries, no other patient prioritization was present. Relatively more arthroplasties were performed in private hospitals. There were no clinically relevant differences in revision arthroplasties between pre-COVID and COVID-period. Estimated total health loss depending on extra capacity ranged from: 19,800 to 29,400 QALYs (Netherlands): 1,700 to 2,400 QALYs (Denmark). With no extra capacity it will take > 30 years to deplete the waiting lists. Conclusion. The COVID-19 pandemic had an enormous negative effect on arthroplasty rates, but more in the Netherlands than Denmark. In the Netherlands, hip and shoulder patients with acute indications were prioritized. Private hospitals filled in part of the capacity gap. QALY loss due to postponed arthroplasty surgeries is considerable. Cite this article: Bone Jt Open 2022;3(12):977–990


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 450 - 459
1 May 2024
Clement ND Galloway S Baron J Smith K Weir DJ Deehan DJ

Aims. The aim was to assess whether robotic-assisted total knee arthroplasty (rTKA) had greater knee-specific outcomes, improved fulfilment of expectations, health-related quality of life (HRQoL), and patient satisfaction when compared with manual TKA (mTKA). Methods. A randomized controlled trial was undertaken (May 2019 to December 2021), and patients were allocated to either mTKA or rTKA. A total of 100 patients were randomized, 50 to each group, of whom 43 rTKA and 38 mTKA patients were available for review at 12 months following surgery. There were no statistically significant preoperative differences between the groups. The minimal clinically important difference in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score was defined as 7.5 points. Results. There were no clinically or statistically significant differences between the knee-specific measures (WOMAC, Oxford Knee Score (OKS), Forgotten Joint Score (FJS)) or HRQoL measures (EuroQol five-dimension questionnaire (EQ-5D) and EuroQol visual analogue scale (EQ-VAS)) at 12 months between the groups. However, the rTKA group had significantly (p = 0.029) greater improvements in the WOMAC pain component (mean difference 9.7, 95% confidence interval (CI) 1.0 to 18.4) over the postoperative period (two, six, and 12 months), which was clinically meaningful. This was not observed for function (p = 0.248) or total (p = 0.147) WOMAC scores. The rTKA group was significantly (p = 0.039) more likely to have expectation of ‘Relief of daytime pain in the joint’ when compared with the mTKA group. There were no other significant differences in expectations met between the groups. There was no significant difference in patient satisfaction with their knee (p = 0.464), return to work (p = 0.464), activities (p = 0.293), or pain (p = 0.701). Conclusion. Patients undergoing rTKA had a clinically meaningful greater improvement in their knee pain over the first 12 months, and were more likely to have fulfilment of their expectation of daytime pain relief compared with patients undergoing mTKA. However, rTKA was not associated with a clinically significant greater knee-specific function or HRQoL, according to current definitions. Cite this article: Bone Joint J 2024;106-B(5):450–459


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1168 - 1176
1 Nov 2023
Yüksel Y Koster LA Kaptein BL Nelissen RGHH den Hollander P

Aims. Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods. A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months’ follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results. At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion. MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA. Cite this article: Bone Joint J 2023;105-B(11):1168–1176


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 69 - 76
1 Jan 2024
Tucker A Roffey DM Guy P Potter JM Broekhuyse HM Lefaivre KA

Aims. Acetabular fractures are associated with long-term morbidity. Our prospective cohort study sought to understand the recovery trajectory of this injury over five years. Methods. Eligible patients at a level I trauma centre were recruited into a longitudinal registry of surgical acetabular fractures between June 2004 and August 2019. Patient-reported outcome measures (PROMs), including the 36-Item Short Form Health Survey (SF-36) physical component summary (PCS), were recorded at baseline pre-injury recall and six months, one year, two years, and five years postoperatively. Comparative analyses were performed for elementary and associated fracture patterns. The proportion of patients achieving minimal clinically important difference (MCID) was determined. The rate of, and time to, conversion to total hip arthroplasty (THA) was also established. Results. We recruited 251 patients (253 fractures), with a 4:1 male to female ratio and mean age of 46.1 years (SD 16.4). Associated fracture patterns accounted for 56.5% of fractures (n = 143). Trajectory analysis showed all timepoints had significant disability versus baseline, including final follow-up (p < 0.001). Elementary fractures had higher SF-36 PCS at six months (p = 0.023) and one year (p = 0.007) compared to associated fractures, but not at two years (p = 0.135) or five years (p = 0.631). The MCID in SF-36 PCS was observed in 37.3% of patients (69/185) between six months and one year, 26.9% of patients (39/145) between one and two years, and 23.3% of patients (20/86) between two and five years, highlighting the long recovery potential of these injuries. A significant proportion of patients failed to attain the MCID after five years (38.1%; 40/105). Conversion to THA occurred in 13.1% of patients (11/110 elementary and 22/143 associated fractures). Approximately two-thirds of THAs (21/33 patients; 63.6%) were performed within two years of index surgery. Conclusion. Acetabular fractures significantly impact physical function. Recovery trajectory is often elongated beyond one year, with two-thirds of our patients displaying persistent clinically relevant long-term disability. Cite this article: Bone Joint J 2024;106-B(1):69–76


Bone & Joint Open
Vol. 4, Issue 10 | Pages 808 - 816
24 Oct 2023
Scott CEH Snowden GT Cawley W Bell KR MacDonald DJ Macpherson GJ Yapp LZ Clement ND

Aims. This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up. Methods. From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed. Results. At 15 years, 28 patients were lost to follow-up (6.1%) and 221 patients (51.9%) had died, with the mean age of the remaining cohort reducing by four years. PROMs response rates among surviving patients were: one-year 63%; five-year 72%; ten-year 94%; and 15-year 59%. OKS and SF-12 scores changed significantly over 15 years (p < 0.001). The mean improvement in OKS was 18.8 (95% confidence (CI) 16.7 to 19.0) at one year. OKS peaked at five years (median 43 years) declining thereafter (p < 0.001), though at 15 years it remained 17.5 better than preoperatively. Age and sex did not alter this trajectory. A quarter of patients experienced a clinically significant decline (≥ 7) in OKS from five to ten years and from ten to 15 years. The SF-12 physical component score displayed a similar trajectory, peaking at one year (p < 0.001). Patient satisfaction was 88% at one, five, and ten years, and 94% at 15 years. In all, 15-year Kaplan-Meier survival was 97.6% (95% CI 96.0% to 99.2%) for any revision, and 98.9% (95% CI 97.9% to 99.9%) for aseptic revision. Conclusion. Improvements in PROMs were significant and maintained following single radius TKA, with OKS peaking at five years, and generic physical health peaking at one year. Patient satisfaction remained high at 15 years, at which point 2.4% had been revised. Cite this article: Bone Jt Open 2023;4(10):808–816


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 331 - 340
1 Mar 2023
Vogt B Toporowski G Gosheger G Laufer A Frommer A Kleine-Koenig M Roedl R Antfang C

Aims. Temporary hemiepiphysiodesis (HED) is applied to children and adolescents to correct angular deformities (ADs) in long bones through guided growth. Traditional Blount staples or two-hole plates are mainly used for this indication. Despite precise surgical techniques and attentive postoperative follow-up, implant-associated complications are frequently described. To address these pitfalls, a flexible staple was developed to combine the advantages of the established implants. This study provides the first results of guided growth using the new implant and compares these with the established two-hole plates and Blount staples. Methods. Between January 2013 and December 2016, 138 patients (22 children, 116 adolescents) with genu valgum or genu varum were treated with 285 flexible staples. The minimum follow-up was 24 months. These results were compared with 98 patients treated with 205 two-hole plates and 92 patients treated with 535 Blount staples. In long-standing anteroposterior radiographs, mechanical axis deviations (MADs) were measured before and during treatment to analyze treatment efficiency. The evaluation of the new flexible staple was performed according to the idea, development, evaluation, assessment, long-term (IDEAL) study framework (Stage 2a). Results. Overall, 79% (109/138) of patients treated with flexible staples achieved sufficient deformity correction. The median treatment duration was 16 months (interquartile range (IQR) 8 to 21). The flexible staples achieved a median MAD correction of 1.2 mm/month/HED site (IQR 0.6 to 2.0) in valgus deformities and 0.6 mm/month/HED site (IQR 0.2 to 1.5) in varus deformities. Wound infections occurred in 1%, haematomas and joint effusions in 4%, and implant-associated complications in 1% of patients treated with flexible staples. Valgus AD were corrected faster using flexible staples than two-hole plates and Blount staples. Furthermore, the median MAD after treatment was lower in varus and valgus AD, fewer implant-associated complications were detected, and reduced implantation times were recorded using flexible staples. Conclusion. The flexible staple seems to be a viable option for guided growth, showing comparable or possibly better results regarding correction speed and reducing implant-associated complications. Further comparative studies are required to substantiate these findings. Cite this article: Bone Joint J 2023;105-B(3):331–340


Bone & Joint Open
Vol. 4, Issue 3 | Pages 210 - 218
28 Mar 2023
Searle HKC Rahman A Desai AP Mellon SJ Murray DW

Aims. To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics. Methods. Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSW. L. ) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%. Results. The mean age was 80.6 years (SD 8.3), with 84 females and 79 males. The mean JSW. L. was 5.6 mm (SD 1.4), and was not significantly related to age, sex, or intraoperative findings. Those with BMI > 40 kg/m. 2. had a smaller JSW. L. than those with a ‘normal’ BMI (p = 0.039). The incidence of severe and moderate lateral OA were both 4.9%. Overall, 2/142 (1.4%) of those with nil/mild lateral OA, 1/8 (13%) with moderate, and 2/8 (25%) with severe subsequently had a revision. Those with severe (mean OKS 35.6 (SD 9.3)) and moderate OA (mean OKS 35.8 (SD 10.5)) tended to have worse outcome scores than those with nil/mild (mean OKS 39.5 (SD 9.2)) but the difference was only significant for OKS-Function (p = 0.044). Conclusion. This study showed that the rate of having severe or moderate radiological lateral OA at 15 years after medial UKA was low (both 4.9%). Although patients with severe or moderate lateral OA had a lower OKS than those with nil/mild OA, their mean scores (OKS 36) would be classified as good. Cite this article: Bone Jt Open 2023;4(3):210–218


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims. Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients. Methods. A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem. Results. The design of the stem was found to have no significant influence on the rate of revision for either sex in the Young group. Uncemented collared stems had a significantly lower rate of revision compared with the other types of stem for females in the Mid-I group. There was a significantly higher rate of revision for uncemented stems in females in the Mid-II group compared with all other types of stem, while in males the rate for uncemented stems was only significantly higher than the rate for cemented stems. Cemented stems had a significantly lower revision rate compared with uncemented and short stems for both sexes in the Old cohort, as did females with collared stems. The rate of immediate postoperative mortality was similar for all types of stem in the Old age group, as were the American Society of Anesthesiologists grades. Conclusion. In patients aged > 80 years, uncemented and short stems had significantly higher revision rates compared with cemented and collared stems, especially in females. The design of the stem and type of fixation have to be analyzed in more detail than only considering cemented and uncemented fixation, in order to further improve the success of THA. Cite this article: Bone Joint J 2024;106-B(3 Supple A):130–136


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims. The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique. Methods. This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively. Results. A total of 517 patients were included in the study. Their mean age was 65.0 years (SD 10.3) and their mean BMI was 29.2 kg/m. 2. (SD 5.5). A mean of 1.2 levels (SD 0.6) were fused with LLIF, and a mean of 1.6 (SD 0.9) posterior levels were fused. Femoral neuropraxia occurred in six patients (1.2%), of which four (0.8%) were LLIF-related and two (0.4%) had persistent symptoms one year postoperatively. Non-femoral neuropraxia occurred in nine patients (1.8%), one (0.2%) was LLIF-related and five (1.0%) were persistent at one year. All LLIF-related neuropraxias resolved by one year. A total of 32 patients (6.2%) had thigh pain, 31 (6.0%) were LLIF-related and three (0.6%) were persistent at one year. Weakness of hip flexion occurred in 14 patients (2.7%), of which eight (1.6%) were LLIF-related and three (0.6%) were persistent at one year. No patients had bowel injury, three (0.6%) had an intraoperative vascular injury (not LLIF-related), and five (1.0%) had ileus. Reoperations occurred in five patients (1.0%) within 30 days, 37 (7.2%) within 90 days, and 41 (7.9%) within one year postoperatively. Conclusion. LLIF involving the L4-L5 disc level has a low rate of persistent neurological, psoas-related, and abdominal complications in patients with the appropriate indications and using a standardized surgical technique. Cite this article: Bone Joint J 2024;106-B(1):53–61


Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion. The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation. Cite this article: Bone Jt Open 2024;5(3):154–161


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 596 - 602
1 Jun 2024
Saarinen AJ Sponseller P Thompson GH White KK Emans J Cahill PJ Hwang S Helenius I

Aims. The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes. Methods. We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group. Results. Mean major curve correction per patient did not differ significantly between the dysplasia group (43%) and the control group (28%; p = 0.087). Mean annual spinal height increase was less in the dysplasia group (9.3 mm (SD 5.1) than in the control group (16 mm (SD 9.2); p < 0.001). Mean annual spinal growth adjusted to patient preoperative standing height during the distraction period was 11% in the dysplasia group and 14% in the control group (p = 0.070). The complication rate was 1.6 times higher (95% confidence interval (CI) 1.3 to 2.0) in the dysplasia group. The following complications were more frequent in the dysplasia group: neurological injury (rate ratio (RR) 5.1 (95% CI 2.3 to 11)), deep surgical site infection (RR 2.2 (95% CI 1.2 to 4.1)), implant-related complications (RR 2.0 (95% CI 1.5 to 2.7)), and unplanned revision (RR 1.8 (95% CI 1.3 to 2.5)). Final fusion did not provide additional spinal height compared with watchful waiting (p = 0.054). There were no significant differences in HRQoL scores between the groups. Conclusion. After growth-friendly EOS treatment, patients with skeletal dysplasias experienced a higher incidence of complications compared to those with other syndromes. Surgical growth-friendly treatment for skeletal dysplasia-associated EOS should be reserved for patients with severe, progressive deformities that are refractory to nonoperative treatment. Cite this article: Bone Joint J 2024;106-B(6):596–602


Bone & Joint Open
Vol. 5, Issue 8 | Pages 628 - 636
2 Aug 2024
Eachempati KK Parameswaran A Ponnala VK Sunil A Sheth NP

Aims. The aims of this study were: 1) to describe extended restricted kinematic alignment (E-rKA), a novel alignment strategy during robotic-assisted total knee arthroplasty (RA-TKA); 2) to compare residual medial compartment tightness following virtual surgical planning during RA-TKA using mechanical alignment (MA) and E-rKA, in the same set of osteoarthritic varus knees; 3) to assess the requirement of soft-tissue releases during RA-TKA using E-rKA; and 4) to compare the accuracy of surgical plan execution between knees managed with adjustments in component positioning alone, and those which require additional soft-tissue releases. Methods. Patients who underwent RA-TKA between January and December 2022 for primary varus osteoarthritis were included. Safe boundaries for E-rKA were defined. Residual medial compartment tightness was compared following virtual surgical planning using E-rKA and MA, in the same set of knees. Soft-tissue releases were documented. Errors in postoperative alignment in relation to planned alignment were compared between patients who did (group A) and did not (group B) require soft-tissue releases. Results. The use of E-rKA helped restore all knees within the predefined boundaries, with appropriate soft-tissue balancing. E-rKA compared with MA resulted in reduced residual medial tightness following surgical planning, in full extension (2.71 mm (SD 1.66) vs 5.16 mm (SD 3.10), respectively; p < 0.001), and 90° of flexion (2.52 mm (SD 1.63) vs 6.27 mm (SD 3.11), respectively; p < 0.001). Among the study population, 156 patients (78%) were managed with minor adjustments in component positioning alone, while 44 (22%) required additional soft-tissue releases. The mean errors in postoperative alignment were 0.53 mm and 0.26 mm among patients in group A and group B, respectively (p = 0.328). Conclusion. E-rKA is an effective and reproducible alignment strategy during RA-TKA, permitting a large proportion of patients to be managed without soft-tissue releases. The execution of minor alterations in component positioning within predefined multiplanar boundaries is a better starting point for gap management than soft-tissue releases. Cite this article: Bone Jt Open 2024;5(8):628–636


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body weight and SP at 0.5 to 1.0 kHz (p < 0.001). Multivariate analyses indicated that the SP at 0.5 to 1.0 kHz and 3.5 to 4.0 kHz was independently associated with the successful fixation. Conclusion. The frequency bands of 0.5 to 1.0 and 3.5 to 4.0 kHz were the key to distinguish the sound characteristics between successful and unsuccessful press-fit cup fixation. Cite this article: Bone Jt Open 2024;4(3):154–161


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims. The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results. Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion. These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids. Cite this article: Bone Joint J 2023;105-B(6):668–678


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims. Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest. Methods. A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS). Results. In the first stage, there were 36 respondents to the survey, with over 70% stating their unit treats more than 20 such cases per year. There was a 50:50 split regarding if the timing of surgery should be within 36 hours, as per the hip fracture guidelines, or 72 hours, as per the open fracture guidelines. Overall, 75% would attempt primary wound closure and 25% would utilize a local flap. There was no orthopaedic agreement on fixation, and 75% would permit weightbearing immediately. In the second stage, performed at the BLRS meeting, experts discussed the survey results and agreed upon a consensus for the management of open elderly ankle fractures. Conclusion. A mutually agreed consensus from the expert panel was reached to enable the best practice for the management of patients with frailty with an open ankle fracture: 1) all units managing lower limb fragility fractures should do so through a cohorted multidisciplinary pathway. This pathway should follow the standards laid down in the "care of the older or frail orthopaedic trauma patient" British Orthopaedic Association Standards for Trauma and Orthopaedics (BOAST) guideline. These patients have low bone density, and we should recommend full falls and bone health assessment; 2) all open lower limb fragility fractures should be treated in a single stage within 24 hours of injury if possible; 3) all patients with fragility fractures of the lower limb should be considered for mobilisation on the day following surgery; 4) all patients with lower limb open fragility fractures should be considered for tissue sparing, with judicious debridement as a default; 5) all patients with open lower limb fragility fractures should be managed by a consultant plastic surgeon with primary closure wherever possible; and 6) the method of fixation must allow for immediate unrestricted weightbearing. Cite this article: Bone Jt Open 2024;5(3):236–242


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims. The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN). Methods. The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications. Results. The mean length of time between the initial injury and surgery was 4.5 years (3 to 10). The mean operating time was 2.8 hours (2.05 to 4.4)), and the mean blood loss was 850 ml (650 to 1,020). Complications occurred in five patients (21.7%): two with wound necrosis, and three with deep vein thrombosis. The mean coronal deformity was significantly corrected from 17.78° (SD 4.62°) preoperatively to 1.35° (SD 1.72°) postoperatively (p < 0.001), and the mean sagittal deformity was significantly corrected from 20.65° (SD 5.88°) preoperatively to 1.61° (SD 1.95°; p < 0.001) postoperatively. The mean leg length discrepancy was significantly corrected from 3.57 cm (SD 1.27) preoperatively to 1.13 cm (SD 0.76) postoperatively (p < 0.001). All fractures healed at a mean of seven months (4 to 12) postoperatively. The mean Lower Extremity Functional Scale score improved significantly from 45.4 (SD 9.1) preoperatively to 66.2 (SD 5.5) postoperatively (p < 0.001). Partial cortical nonunion in the deformed segment occurred in eight patients (34.8%) and healed at a mean of 2.4 years (2 to 3) postoperatively. Conclusion. A clamshell osteotomy combined with IMN fixation in the treatment of patients with a femoral shaft fracture and a previous post-traumatic femoral malunion achieved excellent outcomes. Partial cortical nonunions in the deformed segment also healed satisfactorily. Cite this article: Bone Joint J 2023;105-B(4):449–454


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 751 - 759
1 Jul 2023
Lu V Andronic O Zhang JZ Khanduja V

Aims. Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system. Methods. A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected. Results. A total of 24 studies were included with a total of 3,198 patients (3,233 hips). Patients had significantly less improvement in PROMs if they had Outerbridge grade III and IV lesions (p = 0.012). Compared with microfracture, autologous matrix-induced chondrogenesis (AMIC) resulted in significantly reduced rates of conversion to THA (p = 0.042) and of revision arthroscopy (p = 0.038). Chondral repair procedures in these patients also did not significantly reduce the rates of conversion to THA (p = 0.931), or of revision arthroscopy (p = 0.218). However, compared with microfracture, AMIC significantly reduced the rates of conversion to THA (p = 0.001) and of revision arthroscopy (p = 0.011) in these patients. Those with Outerbridge grade III and IV lesions also had significantly increased rates of conversion to THA (p = 0.029) and of revision arthroscopy (p = 0.023) if they had associated lesions of the acetabulum and femoral head. Those who underwent labral debridement had a significantly increased rate of conversion to THA compared with those who underwent labral repair (p = 0.015). Conclusion. There is universal improvement in PROMs following HA in patients with FAI and associated chondral lesions. However, those with Outerbridge grade III and IV lesions had significantly less improvement in PROMs and a significantly increased rate of conversion to THA than those with Outerbridge grade I and II. This suggests that the outcome of HA in patients with FAI and severe articular cartilage damage may not be favourable. Cite this article: Bone Joint J 2023;105-B(7):751–759


Bone & Joint Open
Vol. 4, Issue 5 | Pages 306 - 314
3 May 2023
Rilby K Mohaddes M Kärrholm J

Aims. Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. Methods. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years. Results. At two and five years, more patients considered the hip with the CLS femoral component as superior but without a statistically significant difference. There were no differences in clinical outcome, magnitude of femoral component migration, or change of bone mineral density at five years. At three months, the Fitmore femoral component had subsided a median -0.71 mm (interquartile range (IQR) -1.67 to -0.20) and the CLS femoral component -0.70 mm (IQR -1.53 to -0.17; p = 0.742). In both groups the femoral head centre had migrated posteriorly (Fitmore -0.17 mm (IQR -0.98 to -0.04) and CLS -0.23 mm (IQR -0.87 to 0.07; p = 0.936)). After three months neither of the femoral components showed much further migration. During the first postoperative year, one Fitmore femoral component was revised due to aseptic loosening. Conclusion. Up to five years, we found no statistically significant difference in outcomes between the Fitmore and the CLS femoral components. The slightly worse outcomes, including one revised hip because of loosening, speaks against the hypothesis that the Fitmore femoral component should be advantageous compared to the CLS if more patients had been recruited to this study. Cite this article: Bone Jt Open 2023;4(5):306–314


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims. The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. Methods. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series. Results. No patients in our series had evidence of radiolucent lines on their latest radiological assessment. Only eight patients out of 454 required revision arthroplasty, and none of these revisions were indicated for aseptic loosening of the tibial baseplate. When compared to data from the NJR annual report, Kaplan-Meier estimates from our series (2.94 (95% confidence interval (CI) 1.24 to 5.87)) show a significant reduction in cumulative estimates of revision compared to all cemented (4.82 (95% CI 4.69 to 4.96)) or cementless TKA (5.65 (95% CI 5.23 to 6.10)). Our data (2.94 (95% CI 1.24 to 5.87)) also show lower cumulative revision rates compared to the most popular implant (PFC Sigma Cemented Knee implant fixation, 4.03 (95% CI 3.75 to 4.33)). The prosthesis time revision rate (PTIR) estimates for our series (2.07 (95% CI 0.95 to 3.83)) were lower than those of cemented cases (4.53 (95% CI 4.49 to 4.57)) from NJR. Conclusion. The NexGen trabecular (tantalum) cementless implant has lower revision rates in our series compared to all cemented implants and other types of cementless implants, and its use in younger patients should be encouraged. Cite this article: Bone Jt Open 2024;5(4):277–285