Fifty-nine cases of trochanteric wire revision following hip arthroplasty with trochanteric osteotomy and reattachment were identified and their outcome was studied. Two were infected and were excluded. Five were revised for instability: four became stable while one continued to have persistent dislocation. Fifty-two were revised for pain, 36 by removal of the trochanteric wire and 16 by reattachment of the greater trochanter. Successful relief of pain was obtained in less than half the cases. There was no difference in the incidence of back pain, wiring technique, trochanteric advancement, previous surgery to the same hip, trochanteric size or the pattern of wire breakage in the successfully treated group and the unsuccessful group. Neither was the removal of intact wire from a united trochanter any more certain of relieving pain than removal of broken wire from an un-united trochanter. Six patients later required revision for loosening or infection. These results indicate the need for full radiological and haematological investigation before exploration of the greater trochanter. At exploration for pain the wires should simply be removed as we could show no successful union after late reattachment of the trochanter in the absence of instability.
We examined 59 cemented high density polyethylene sockets removed at revision hip arthroplasty. Of these 19 showed areas of wear between the outside of the socket and the acetabular bone. This was associated with lack of acrylic cement in those areas and was also related to the depth of the wear on the articulating surface of the socket. It is suggested that, in some cases, changes at the bone-cement junction are secondary to socket loosening and abrasion against the bone of the acetabulum, rather than to particles migrating from the metal-polyethylene interface. It is therefore important that impingement of the neck of the femoral stem on the edge of the cup be avoided and that, when the socket is inserted, it is not in direct contact with the bone.
We report two cases of aneurysm of the external iliac artery after arthroplasty of the hip. In each case the patients suffered from severe, seropositive, rheumatoid arthritis, had been treated with oral corticosteroids and had defects in the acetabular floor which were complicated by sepsis. In these circumstances bleeding from the wound in the hip should be investigated by immediate arteriography with anteroposterior and lateral views. Though vascular injury during operations on the hip is rare, recognition is important as safe and satisfactory treatment can be achieved. In the surgical management of these cases the following points should be noted: an alternative blood supply to the limb must be established using separate surgical incisions; to reduce the risk of sepsis these incisions should be closed and dressed before exploring the aneurysm; the aneurysmal vessel must be isolated and ligated, no attempt being made at primary repair; the aneurysm should be opened longitudinally to avoid damaging the femoral nerve which overlies it; and all foreign material should be removed from the hip.
One thousand and forty-two McKee-Farrar prostheses of the present design inserted in Norwich from January 1965 to December 1972 have been reviewed retrospectively to determine the incidence of complications needing revision. Of prostheses implanted for more than two years, 6.6 per cent needed revision for loosening (cup 35 per cent; stem 2.2 per cent; both components 0.9 per cent). Of the total number, 2.3 per cent became infected and 1.9 per cent dislocated. Most dislocations needed only a single closed reduction but 08 per cent were revised. The outcome of revision operations was also assessed. Of revisions for loosening, 40 per cent needed no further operation but 23 per cent required excision; pelvic fracture or bone destruction around the components made success unlikely. Revisions for dislocation were disappointing. Of all revisions 17 per cent became infected. Excision arthroplasty is better than a series of failed revisions in an elderly patient.
The February 2024 Trauma Roundup. 360. looks at: Posterior malleolus fractures: what about medium-sized fragments?; Acute or delayed
The February 2024 Children’s orthopaedics Roundup. 360. looks at: Hip impingement after in situ pinning causes decreased flexion and forced external rotation in flexion on 3D-CT; Triplane ankle fracture patterns in paediatric patients; Improved forearm rotation even after early conversion to below-elbow; Selective dorsal rhizotomy and cerebral palsy (CP) hip displacement; Abduction bracing following anterior open reduction for developmental dysplasia of the hip does not improve residual dysplasia or reduce secondary surgery; 40% risk of later
The April 2024 Oncology Roundup. 360. looks at: Midterm outcomes of
Aims. The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a
Our aim was to determine if the height of the cup, lateralisation or the abduction angle correlated with functional outcome or survivorship in revision total hip replacement in patients with a previous diagnosis of developmental dysplasia of the hip. A retrospective investigation of 51 patients (63 hips) who had undergone revision total hip replacement was performed. The mean duration of follow-up was 119 months. Forty-one patients (52 hips) were available for both determination of functional outcome and survivorship analysis. Ten patients (11 hips) were only available for survivorship analysis. The height of the cup was found to have a statistically significant correlation with functional outcome and a high hip centre correlated with a worse outcome score. Patients with a hip centre of less than 3.5 cm above the anatomical level had a statistically better survivorship of the cup than those with centres higher than this. Restoration of the height of the centre of the hip to as near the anatomical position as possible improved functional outcome and survivorship of the cup.
We conducted a retrospective study to assess
the prevalence of adverse reactions to metal debris (ARMD) in patients
operated on at our institution with metal-on-metal (MoM) total hip
replacements with 36 mm heads using a Pinnacle acetabular shell.
A total of 326 patients (150 males, 175 hips; 176 females, 203 hips)
with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5
years (0.1 to 10.8) participating in our in-depth modern MoM follow-up
programme were included in the study, which involved recording whole
blood cobalt and chromium ion measurements, Oxford hip scores (OHS)
and plain radiographs of the hip and targeted cross-sectional imaging. Elevated
blood metal ion levels (>
5 parts per billion) were seen in 32 (16.1%)
of the 199 patients who underwent unilateral replacement. At 23
months after the start of our modern MoM follow-up programme, 29
new cases of ARMD had been revealed. Hence, the nine-year survival
of this cohort declined from 96% (95% CI 95 to 98) with the old
surveillance routine to 86% (95% CI 82 to 90) following the new
protocol. Although ARMD may not be as common in 36 mm MoM THRs as
in those with larger heads, these results support the Medicines
and Healthcare Products Regulatory Agency guidelines on regular
reviews and further investigations, and emphasise the need for specific
a follow-up programme for patients with MoM THRs. Cite this article:
We analysed follow-up data from 18 486 primary total hip arthroplasties performed between 1967 and 2001 to assess the validity of clinical procedures in diagnosing loosening of prosthetic components. Sensitivity, specificity and predictive values were estimated with the radiological definition of loose or not loose as the ‘gold standard’. The prevalence of acetabular loosening increased from 0.6% to 13.9% during the period of the study and that of femoral loosening from 0.9% to 12.1%. Sensitivities and positive predictive values were low, suggesting that clinical procedures could not replace radiological assessment in the identification of loose prostheses. Specificities and negative predictive values were constantly above 0.86. The possibility of there being a prosthesis which is not loose in asymptomatic patients was consequently very high, particularly during the first five to six years after operation. The necessity of periodic clinical and radiological follow-up examinations of asymptomatic patients during the first five to six years after operation remains questionable. Symptomatic patients, however, require radiological assessment.
Aims. The COVID-19 pandemic has caused unprecedented disruption to elective orthopaedic services. The primary objective of this study was to examine changes in functional scores in patients awaiting
Aims. Hyaline cartilage has a low capacity for regeneration. Untreated osteochondral lesions of the femoral head can lead to progressive and symptomatic osteoarthritis of the hip. The purpose of this study is to analyze the clinical and radiological long-term outcome of patients treated with osteochondral autograft transfer. To our knowledge, this study represents a series of osteochondral autograft transfer of the hip with the longest follow-up. Methods. We retrospectively evaluated 11 hips in 11 patients who underwent osteochondral autograft transfer in our institution between 1996 and 2012. The mean age at the time of surgery was 28.6 years (8 to 45). Outcome measurement included standardized scores and conventional radiographs. Kaplan-Meier survival curve was used to determine the failure of the procedures, with conversion to
Aims. Although there are various pelvic osteotomies for acetabular dysplasia of the hip, shelf operations offer effective and minimally invasive osteotomy. Our study aimed to assess outcomes following modified Spitzy shelf acetabuloplasty. Methods. Between November 2000 and December 2016, we retrospectively evaluated 144 consecutive hip procedures in 122 patients a minimum of five years after undergoing modified Spitzy shelf acetabuloplasty for acetabular dysplasia including osteoarthritis (OA). Our follow-up rate was 92%. The mean age at time of surgery was 37 years (13 to 58), with a mean follow-up of 11 years (5 to 21). Advanced OA (Tönnis grade ≥ 2) was present preoperatively in 16 hips (11%). The preoperative lateral centre-edge angle ranged from -28° to 25°. Survival was determined by Kaplan-Meier analysis, using conversions to
We evaluated all cases involving the combined use of a subtrochanteric derotational femoral shortening osteotomy with a cemented Exeter stem performed at our institution. With severe developmental dysplasia of the hip an osteotomy is often necessary to achieve shortening and derotation of the proximal femur. Reduction can be maintained with a 3.5 mm compression plate while the implant is cemented into place. Such a plate was used to stabilise the osteotomy in all cases. Intramedullary autograft helps to prevent cement interposition at the osteotomy site and promotes healing. There were 15 female patients (18 hips) with a mean age of 51 years (33 to 75) who had a Crowe IV dysplasia of the hip and were followed up for a mean of 114 months (52 to 168). None was lost to follow-up. All clinical scores were collected prospectively. The Charnley modification of the Merle D’Aubigné-Postel scores for pain, function and range of movement showed a statistically significant improvement from a mean of 2.4 (1 to 4), 2.3 (1 to 4), 3.4 (1 to 6) to 5.2 (3 to 6), 4.4 (3 to 6), 5.2 (4 to 6), respectively. Three acetabular revisions were required for aseptic loosening; one required femoral revision for access. One osteotomy failed to unite at 14 months and was revised successfully. No other case required a femoral revision. No postoperative sciatic nerve palsy was observed. Cemented Exeter femoral components perform well in the treatment of Crowe IV dysplasia with this procedure.
We assessed 100 patients with a primary total hip replacement using the Harris hip score and the Nottingham Health Profile at one, three and five years after operation. They were derived from two prospective randomised series of cemented and uncemented replacements. Both scoring systems correlated highly and were each heavily influenced by the system of functional classification defined by Charnley. After five years both reflected the function of the implant and the general state of the patient. A higher degree of sensitivity is needed to show differences in the performance of an implant in the short and medium term. We do not yet have an ideal system of clinical assessment and the overall function must always be properly assessed.