Advertisement for orthosearch.org.uk
Results 581 - 600 of 914
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures.

Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance.

There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation (sd) 0.7) and 0.7 mm (sd 0.7) and 0.6 mm (sd 0.6) and 0.4 mm (sd 0.5), respectively; p = 0.18 and p = 0.35).

Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate.

Cite this article: Bone Joint J 2015; 97-B:957–62.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1488 - 1492
1 Nov 2015
Tansey RJ Benjamin-Laing H Jassim S Liekens K Shankar A Haddad FS

Hip and groin injuries are common in athletes who take part in high level sports. Adductor muscle tendon injuries represent a small but important number of these injuries. Avulsion of the tendons attached to the symphysis pubis has previously been described: these can be managed both operatively and non-operatively. We describe an uncommon variant of this injury, namely complete avulsion of the adductor sleeve complex: this includes adductor longus, pectineus and rectus abdominis. We go on to describe a surgical technique which promotes a full return to the pre-injury level of sporting activity.

Over a period of ten years, 15 high-level athletes with an MRI-confirmed acute adductor complex avulsion injury (six to 34 days old) underwent surgical repair. The operative procedure consisted of anatomical re-attachment of the avulsed tissues in each case and mesh reinforcement of the posterior inguinal wall in seven patients. All underwent a standardised rehabilitation programme, which was then individualised to be sport-specific.

One patient developed a superficial wound infection, which was successfully treated with antibiotics. Of the 15 patients, four complained of transient local numbness which resolved in all cases. All patients (including seven elite athletes) returned to their previous level of participation in sport.

Cite this article: Bone Joint J 2015;97-B:1488–92.


Bone & Joint Research
Vol. 5, Issue 6 | Pages 269 - 275
1 Jun 2016
Ono Y Woodmass JM Nelson AA Boorman RS Thornton GM Lo IKY

Objectives

This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P).

Methods

Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1520 - 1524
1 Nov 2014
van der Zwaal P Pijls BG Thomassen BJW Lindenburg R Nelissen RGHH van de Sande MAJ

The purpose of this study was to evaluate the natural history of rheumatoid disease of the shoulder over an eight-year period. Our hypothesis was that progression of the disease is associated with a decrease in function with time.

A total of 22 patients (44 shoulders; 17 women, 5 men, (mean age 63)) with rheumatoid arthritis were followed for eight years. All shoulders were assessed using the Constant score, anteroposterior radiographs (Larsen score, Upward-Migration-Index (UMI)) and ultrasound (US). At final follow-up, the Short Form-36, disabilities of the arm, shoulder and hand (DASH) Score, erythrocyte sedimentation rate and use of anti-rheumatic medication were determined.

The mean Constant score was 72 points (50 to 88) at baseline and 69 points (25 to 100) at final follow-up. Radiological evaluation showed progressive destruction of the peri-articular structures with time. This progression of joint and rotator cuff destruction was significantly associated with the Constant score. However, at baseline only the extent of rotator cuff disease and the UMI could predict the Constant score at final follow-up.

A plain anteroposterior radiograph of the shoulder is sufficient to assess any progression of rheumatoid disease and to predict functional outcome in the long term by using the UMI as an indicator of rotator cuff degeneration.

Cite this article: Bone Joint J 2014;96-B:1520–4.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 344 - 350
1 Mar 2017
Metcalfe AJ Clark DA Kemp MA Eldridge JD

Aims

The Bereiter trochleoplasty has been used in our unit for 12 years to manage recurrent patellar instability in patients with severe trochlea dysplasia. The aim of this study was to document the outcome of a large consecutive cohort of patients who have undergone this operation.

Patients and Methods

Between June 2002 and August 2013, 214 consecutive trochleoplasties were carried out in 185 patients. There were 133 women and 52 men with a mean age of 21.3 years (14 to 38). All patients were offered yearly clinical and radiological follow-up. They completed the following patient reported outcome scores (PROMs): International Knee Documentation Committee subjective scale, the Kujala score, the Western Ontario and McMaster Universities Arthritis Index score and the short-form (SF)-12.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 204 - 210
1 Feb 2017
Xu J Jia Y Kang Q Chai Y

Aims

To present our experience of using a combination of intra-articular osteotomy and external fixation to treat different deformities of the knee.

Patients and Methods

A total of six patients with a mean age of 26.5 years (15 to 50) with an abnormal hemi-joint line convergence angle (HJLCA) and mechanical axis deviation (MAD) were included. Elevation of a tibial hemiplateau or femoral condylar advancement was performed and limb lengthening with correction of residual deformity using a circular or monolateral Ilizarov frame.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 16 - 21
1 Jan 2017
Aprato A Leunig M Massé A Slongo T Ganz R

Aims

Several studies have reported the safety and efficacy of subcapital re-alignment for patients with slipped capital femoral epiphysis (SCFE) using surgical dislocation of the hip and an extended retinacular flap. Instability of the hip and dislocation as a consequence of this surgery has only recently gained attention. We discuss this problem with some illustrative cases.

Materials and Methods

We explored the literature on the possible pathophysiological causes and surgical steps associated with the risk of post-operative instability and articular damage. In addition, we describe supplementary steps that could be used to avoid these problems.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 35 - 38
1 Aug 2014
Hammerberg EM


Bone & Joint 360
Vol. 5, Issue 6 | Pages 37 - 39
1 Dec 2016


Bone & Joint Research
Vol. 3, Issue 4 | Pages 117 - 122
1 Apr 2014
Uhthoff HK Coletta E Trudel G

Objectives

Although many clinical and experimental investigations have shed light on muscle atrophy and intramuscular accumulation of fat after rotator cuff disruption, none have reported on their onset in the absence of muscle retraction.

Methods

In 30 rabbits, we detached one supraspinatus (SSP) tendon and repaired it immediately, thus preventing muscle retraction. The animals were killed in groups of 10 at one, two and six weeks. Both shoulders of 15 non-operated rabbits served as controls. We measured the weight and volume of SSP muscles and quantified the cross-sectional area of intramuscular fat (i-fat) histologically.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 5 - 11
1 Jan 2017
Vulcano E Myerson MS

The last decade has seen a considerable increase in the use of in total ankle arthroplasty (TAA) to treat patients with end-stage arthritis of the ankle. However, the longevity of the implants is still far from that of total knee and hip arthroplasties.

The aim of this review is to outline a diagnostic and treatment algorithm for the painful TAA to be used when considering revision surgery.

Cite this article: Bone Joint J 2017;99-B:5–11.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 21 - 24
1 Dec 2016


Bone & Joint 360
Vol. 5, Issue 5 | Pages 37 - 38
1 Oct 2016
Das A


Bone & Joint 360
Vol. 4, Issue 2 | Pages 20 - 23
1 Apr 2015

The April 2015 Shoulder & Elbow Roundup360 looks at: Distal clavicular resection not indicated in cuff repair?; Platelet-rich plasma in rotator cuff repair; Radial head geometry: time to change?; Heterotopic ossification in elbow trauma; Another look at heterotopic ossification in the humerus; Triceps on for total elbow arthroplasty?; Predicting outcomes in rotator cuff repair; Deltoid fatty infiltration and reverse shoulder arthroplasty


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 21 - 27
1 Jan 2016
Basheer SZ Cooper AP Maheshwari R Balakumar B Madan S

Slipped capital femoral epiphysis (SCFE) may lead to symptomatic femoroacetabular impingement (FAI). We report our experience of arthroscopic treatment, including osteochondroplasty, for the sequelae of SCFE.

Data were prospectively collected on patients undergoing arthroscopy of the hip for the sequelae of SCFE between March 2007 and February 2013, including demographic data, radiological assessment of the deformity and other factors that may influence outcome, such as the presence of established avascular necrosis. Patients completed the modified Harris hip score (mHHS) and the non-arthritic hip score (NAHS) before and after surgery.

In total, 18 patients with a mean age of 19 years (13 to 42), were included in the study. All patients presented with pain in the hip and mechanical symptoms, and had evidence of FAI (cam or mixed impingement) on plain radiographs.

The patients underwent arthroscopic osteoplasty of the femoral neck. The mean follow-up was 29 months (23 to 56).

The mean mHHS and NAHS scores improved from 56.2 (27.5 to 100.1) and 52.1 (12.5 to 97.5) pre-operatively to 75.1 (33.8 to 96.8, p = 0.01) and 73.6 (18.8 to 100, p = 0.02) at final follow-up, respectively. Linear regression analysis demonstrated a significant association between poorer outcome scores and increased time to surgery following SCFE (p < 0.05 for all parameters except baseline MHHS).

Symptomatic FAI following (SCFE) may be addressed using arthroscopic techniques, and should be treated promptly to minimise progressive functional impairment and chondrolabral degeneration.

Take home message: Arthroscopy of the hip can be used to treat femoroacetabular impingement successfully following SCFE. However, this should be performed promptly after presentation in order to prevent irreversible progression and poorer clinical outcomes.

Cite this article: Bone Joint J 2016;98-B:21–7.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 37 - 43
1 Jan 2016
Beverland DE O’Neill CKJ Rutherford M Molloy D Hill JC

Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality.

The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):37–43.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 46 - 46
1 Feb 2014

The February 2014 Research Roundup360 looks at: blood supply to the femoral head after dislocation; diabetes and hip replacement; bone remodelling over two decades following hip replacement; sham surgery as good as arthroscopic meniscectomy; distraction in knee osteoarthritis; whether joint replacement prevent cardiac events; tranexamic acid and knee replacement haemostasis; cartilage colonisation in bipolar ankle grafts; CTs and proof of fusion; atorvastatin for muscle re-innervation after sciatic nerve transection; microfracture and short-term pain in cuff repair; promising early results from L-PRF augmented cuff repairs; and fatty degeneration in a rodent model.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results.

In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy).

The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection.

The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61.

On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching.

The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising.

Cite this article: Bone Joint J 2015;97-B:1662–7.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1533 - 1538
1 Nov 2015
Zhang X Shao X Huang W Zhu H Yu Y

We report a new surgical technique for the treatment of traumatic dislocation of the carpometacarpal (CMC) joint of the thumb. This is a tenodesis which uses part of the flexor carpi radialis.

Between January 2010 and August 2013, 13 patients with traumatic instability of the CMC joint of the thumb were treated using this technique. The mean time interval between injury and ligament reconstruction was 13 days (0 to 42). The mean age of the patients at surgery was 38 years: all were male.

At a mean final follow-up of 26 months (24 to 29), no patient experienced any residual instability. The mean total palmar abduction of the CMC joint of the thumb was 61° and the mean radial abduction 65° The mean measurements for the uninjured hand were 66° (60° to 73°) and 68° (60° to 75°), respectively. The mean Kapandji thumb opposition score was 8.5° (8° to 9°). The mean pinch and grip strengths of the hand were 6.7 kg (3.4 to 8.2) and 40 kg (25 to 49), respectively. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 3 (1 to 6). Based on the Smith and Cooney score, we obtained a mean score of 85 (75 to 95), which included four excellent, seven good, and two fair results.

Our technique offers an alternative method of treating traumatic dislocation of the CMC joint of the thumb: it produces a stable joint and acceptable hand function.

Cite this article: Bone Joint J 2015;97-B:1533–8.