Advertisement for orthosearch.org.uk
Results 41 - 60 of 2348
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims

The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs).

Methods

We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.


Bone & Joint 360
Vol. 11, Issue 4 | Pages 17 - 21
1 Aug 2022


Bone & Joint 360
Vol. 11, Issue 3 | Pages 14 - 17
1 Jun 2022


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 205 - 211
1 Mar 2004
Henderson I Tuy B Oakes B

We have reviewed 22 patients from a total of 135 treated by autologous chondrocyte implantation (ACI) who had undergone further surgery for pain in the knee and mechanical symptoms after a mean of 10.5 months. There were 31 grafted lesions. At operation the findings included lifting (24/31) and detachment (3/31) of periosteal patches for which arthroscopic shaving was performed. Chondroplasty was undertaken on two new lesions, another required an ACI and a further patient required trimming of a meniscus. The mechanical symptoms resolved within two weeks. At the last review, two to 14 months from reoperation; 68% had improved, and 86% had normal or nearly normal IKDC scores. Of the 31 lesions, 30 (97%) had normal or nearly normal visual repair scores. Biopsy showed good integration with subchondral bone and the marginal interface in all specimens, most of which showed hyaline or hyaline-like cartilage (70%). Troublesome mechanical symptoms required surgery in 13% of ACI-treated patients and were attributed to periosteal extrusion. Simple arthroscopic debridement was curative


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 864 - 866
1 Aug 2000
Palmer SJ Parker MJ Hollingworth W

Revision operations after fracture of the hip are costly, in both monetary and personal terms. We have assessed whether these costs applied equally to all complications after the primary procedure. We studied 3154 consecutive patients with fracture of the hip and analysed the complications and financial implications related to reoperation within one year of injury. The results showed that revision surgery is not always associated with a significant increase in morbidity, financial cost or mortality, but is directly related to the underlying complication


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1363 - 1369
1 Oct 2010
Garcia-Cimbrelo E Garcia-Rey E Cruz-Pardos A Madero R

Revision surgery of the hip was performed on 114 hips using an extensively porous-coated femoral component. Of these, 95 hips (94 patients) had a mean follow-up of 10.2 years (5 to 17). No cortical struts were used and the cortical index and the femoral cortical width were measured at different levels. There were two revisions for aseptic loosening. Survivorship at 12 years for all causes of failure was 96.9% (95% confidence interval 93.5 to 100) in the best-case scenario. Fibrous or unstable fixation was associated with major bone defects. The cortical index (p = 0.045) and the lateral cortical thickness (p = 0.008) decreased at the proximal level over time while the medial cortex increased (p = 0.001) at the proximal and distal levels. An increase in the proximal medial cortex was found in patients with an extended transtrochanteric osteotomy (p = 0.026) and in those with components shorter than 25 cm (p = 0.008). The use of the extensively porous-coated femoral component can provide a solution for difficult cases in revision surgery. Radiological bony ingrowth is common. Although without clinical relevance at the end of follow-up, the thickness of the medial femoral cortex often increased while that of the lateral cortex decreased. In cases in which a shorter component was used and in those undertaken using an extended trochanteric osteotomy, there was a greater increase in thickness of the femoral cortex over time


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 899 - 901
1 Nov 1991
McMinn D Roberts P Forward G

A new approach to the hip is described that allows better exposure for difficult revision surgery without the need for trochanteric osteotomy. A V-shaped myofascial flap consisting of the proximal part of vastus lateralis and its fascia with gluteus medius and minimus, is reflected off the greater trochanter and proximal femur giving access to the entire capsule of the hip. If the leg has been significantly lengthened by the revision procedure, abductor tension can be adjusted at closure by altering the reattachment of the flap, analogous to a V-Y-plasty


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 31 - 35
1 Jan 1997
Holzer G Windhager R Kotz R

We have reviewed the results of one-stage revision surgery in 18 patients for infection of megaprostheses implanted after the resection of malignant bone and soft-tissue tumours. At a mean follow-up of 52.0 ± 35.0 months (18 to 135) infection was eliminated in 14 of the 18 patients. The infection-free patients showed no abnormal tests for inflammation and had a mean Enneking score of 20.6 ± 5.0 points (maximum 30 points). We suggest that one-stage revision without exchange of the anchorage parts is justified in patients with megaprostheses infected by antibiotic-sensitive micro-organisms


Bone & Joint 360
Vol. 11, Issue 1 | Pages 32 - 35
1 Feb 2022


Bone & Joint Open
Vol. 3, Issue 3 | Pages 245 - 251
16 Mar 2022
Lester D Barber C Sowers CB Cyrus JW Vap AR Golladay GJ Patel NK

Aims

Return to sport following undergoing total (TKA) and unicompartmental knee arthroplasty (UKA) has been researched with meta-analyses and systematic reviews of varying quality. The aim of this study is to create an umbrella review to consolidate the data into consensus guidelines for returning to sports following TKA and UKA.

Methods

Systematic reviews and meta-analyses written between 2010 and 2020 were systematically searched. Studies were independently screened by two reviewers and methodology quality was assessed. Variables for analysis included objective classification of which sports are safe to participate in postoperatively, time to return to sport, prognostic indicators of returning, and reasons patients do not.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 188 - 193
1 Feb 2011
Rudol G Wilcox R Jin Z Tsiridis E

The mechanical performance of the cement-in-cement interface in revision surgery has not been fully investigated. The quantitative effect posed by interstitial fluids and roughening of the primary mantle remains unclear. We have analysed the strength of the bilaminar cement-bone interface after exposure of the surface of the primary mantle to roughening and fluid interference. The end surfaces of cylindrical blocks of cement were machined smooth (Ra = 200 nm) or rough (Ra = 5 μm) and exposed to either different volumes of water and carboxymethylcellulose (a bone-marrow equivalent) or left dry. Secondary blocks were cast against the modelled surface. Monoblocks of cement were used as a control group. The porosity of the samples was investigated using micro-CT. Samples were exposed to a single shearing force to failure. The mean failure load of the monoblock control was 5.63 kN (95% confidence interval (CI) 5.17 to 6.08) with an estimated shear strength of 36 MPa. When small volumes of any fluid or large volumes were used, the respective values fell between 4.66 kN and 4.84 kN with no significant difference irrespective of roughening (p > 0.05). Large volumes of carboxymethylcellulose significantly weakened the interface. Roughening in this group significantly increased the strength with failure loads of 2.80 kN (95% CI 2.37 to 3.21) compared with 0.86 kN (95% CI 0.43 to 1.27) in the smooth variant. Roughening of the primary mantle may not therefore be as crucial as has been previously thought in clinically relevant circumstances


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 228 - 231
1 Feb 2008
Buttaro M Araujo GS Araujo ES Comba F Piccaluga F

Metal meshes are used in revision surgery of the hip to contain impacted bone grafts in cases with cortical or calcar defects in order to provide rotational stability to the stem. However, the viability of bone allografts under these metal meshes has been uncertain. We describe the histological appearances of biopsies obtained from impacted bone allografts to the calcar contained by a metal mesh in two femoral reconstructions which needed further surgery at 24 and 33 months after the revision procedure. A line of osteoid and viable new bone was observed on the surface of necrotic trabeculae. Active bone marrow between these trabeculae showed necrotic areas in some medullary spaces with reparative fibrous tissue and isolated reactive lymphocytes. This is interpreted as reparative changes after revascularisation of the cancellous allografts. These pathological findings are similar to those reported in allografts contained by cortical host bone and support the hypothesis that incorporation of morcellised bone under metal meshes is not affected by these devices


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 90 - 101
1 Jan 2020
Davis ET Pagkalos J Kopjar B

Aims

The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA).

Methods

Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad).


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 324 - 330
1 Mar 2018
Mahure SA Mollon B Capogna BM Zuckerman JD Kwon YW Rokito AS

Aims

The factors that predispose to recurrent instability and revision stabilization procedures after arthroscopic Bankart repair for anterior glenohumeral instability remain unclear. We sought to determine the rate and risk factors associated with ongoing instability in patients undergoing arthroscopic Bankart repair for instability of the shoulder.

Materials and Methods

We used the Statewide Planning and Research Cooperative System (SPARCS) database to identify patients with a diagnosis of anterior instability of the shoulder undergoing arthroscopic Bankart repair between 2003 and 2011. Patients were followed for a minimum of three years. Baseline demographics and subsequent further surgery to the ipsilateral shoulder were analyzed. Multivariate analysis was used to identify independent risk factors for recurrent instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1513 - 1517
1 Nov 2011
Singh JA Sperling JW Cofield RH

Our objective was to examine the rate of revision and its predictive factors in patients undergoing total shoulder arthroplasty (TSA). We used prospectively collected data from the Mayo Clinic Total Joint Registry to examine five-, ten- and 20-year revision-free survival following TSA and the predictive factors. We examined patient characteristics (age, gender, body mass index, comorbidity), implant fixation (cemented versus uncemented), American Society of Anesthesiologists class and underlying diagnosis. Univariate and multivariable adjusted hazard rates were calculated using Cox regression analysis. A total of 2207 patients underwent 2588 TSAs. Their mean age was 65.0 years (19 to 91) and 1163 (53%) were women; osteoarthritis was the underlying diagnosis in 1640 shoulders (63%). In all, 212 TSAs (8.2%) were revised during the follow-up period. At five, ten and 20 years, survival rates were 94.2% (95% confidence interval (CI) 93.2 to 95.3), 90.2% (95% CI 88.7 to 91.7) and 81.4% (95% CI 78.4 to 84.5), respectively. In multivariable analyses men had a higher hazard ratio of revision of 1.72 (95% CI 1.28 to 2.31) (p < 0.01) compared with women, and those with rotator cuff disease had a hazard ratio of 4.71 (95% CI 2.09 to 10.59) (p < 0.001) compared with patients with rheumatoid arthritis. We concluded that male gender and rotator cuff disease are independent risk factors for revision after TSA. Future studies are needed to understand the biological rationale for these differences.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 615 - 618
1 May 2012
ten Have BLEF Brouwer MD RW van Biezen FC Verhaar JAN

The purpose of this prospective study was to evaluate the long-term clinical and radiological outcomes of revision of the femoral component of a total hip replacement using impaction bone grafting. Femoral revision with an impacted allograft was performed on 29 patients (31 hips). In all, 21 hips (68%) had grade III or IV femoral defects according to the Endo-Klinik classification. A total of 11 patients (12 hips) died before the ten-year follow-up period. Of the remaining patients, 18 patients (19 hips) were followed for 10 to 15 years; three further patients died during this time. None of the 31 stems underwent further revision of their stem. However, four stems showed extensive subsidence (> 15 mm). One of these patients had a femoral fracture that required fixation. Three other patients had a femoral fracture, two of which required fixation and the other was treated conservatively. Patients with a femoral fracture and/or severe subsidence had significantly more grade IV defects (six of seven hips; p = 0.004). One patient needed a closed reduction for dislocation.

Impaction allografting in revision hip surgery gives good long-term results for femora with grades I, II and III Endo-Klinik-classified defects. Extensive subsidence and femoral fractures were seen mainly in patients with grade IV damaged femora.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 56 - 59
1 Nov 2014
Konan S Garbuz DS Masri BA Duncan CP

Non-modular tapered fluted, titanium stems are available for use in femoral revision. The combination of taper and flutes on the stem provides axial and rotational stability, respectively. The material and surface properties of the stem promotes bone on-growth. If the surgeon is confident and reasonably experienced in the surgical use of this sort of design and the case is relatively straightforward, a non-modular design is effective. It also potentially reduces implant inventory, and circumvents the potential problems of taper junction corrosion and fatigue fracture. There are reports of excellent survival, good clinical and functional results and evidence of subsequent increase in proximal bone stock.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):56–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1411 - 1415
1 Oct 2011
Wainwright C Theis J Garneti N Melloh M

We compared revision and mortality rates of 4668 patients undergoing primary total hip and knee replacement between 1989 and 2007 at a University Hospital in New Zealand. The mean age at the time of surgery was 69 years (16 to 100). A total of 1175 patients (25%) had died at follow-up at a mean of ten years post-operatively. The mean age of those who died within ten years of surgery was 74.4 years (29 to 97) at time of surgery. No change in comorbidity score or age of the patients receiving joint replacement was noted during the study period. No association of revision or death could be proven with higher comorbidity scoring, grade of surgeon, or patient gender.

We found that patients younger than 50 years at the time of surgery have a greater chance of requiring a revision than of dying, those around 58 years of age have a 50:50 chance of needing a revision, and in those older than 62 years the prosthesis will normally outlast the patient. Patients over 77 years old have a greater than 90% chance of dying than requiring a revision whereas those around 47 years are on average twice as likely to require a revision than die. This information can be used to rationalise the need for long-term surveillance and during the informed consent process.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1457 - 1464
1 Nov 2011
Garcia-Cimbrelo E Garcia-Rey E Cruz-Pardos A

We report the results of 79 patients (81 hips) who underwent impaction grafting at revision hip replacement using the Exeter femoral stem. Their mean age was 64 years (31 to 83). According to the Endoklinik classification, 20 hips had a type 2 bone defect, 40 had type 3, and 21 had type 4. The mean follow-up for unrevised stems was 10.4 years (5 to 17).

There were 12 re-operations due to intra- and post-operative fractures, infection (one hip) and aseptic loosening (one hip). All re-operations affected type 3 (6 hips) and 4 (6 hips) bone defects. The survival rate for re-operation for any cause was 100% for type 2, 81.2% (95% confidence interval (CI) 67.1 to 95.3) for type 3, and 70.8% (95% CI 51.1 to 90.5) for type 4 defects at 14 years. The survival rate with further revision for aseptic loosening as the end point was 98.6% (95% CI 95.8 to 100). The final clinical score was higher for patients with type 2 bone defects than type 4 regarding pain, function and range of movement. Limp was most frequent in the type 4 group (p < 0.001). The mean subsidence of the stem was 2.3 mm (sd 3.7) for hips with a type 2 defect, 4.3 mm (sd 7.2) for type 3 and 9.6 mm (sd 10.8) for type 4 (p = 0.022).

The impacted bone grafting technique has good clinical results in femoral revision. However, major bone defects affect clinical outcome and also result in more operative complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1107 - 1110
1 Aug 2005
Ali A Douglas H Stanley D

Sixteen patients who underwent a revision operation for nonunion of fractures of the distal humerus following previous internal fixation were reviewed at a mean follow-up of 39 months (8 to 69).

The Mayo elbow performance score was excellent in 11, good in two, fair in two and poor in one. In 15 patients union was achieved and in one with an infected nonunion a subsequent bone graft was necessary in order to obtain union.

Age, gender, a history of smoking, mechanism of the injury and the AO classification of the initial fracture did not correlate with the development of nonunion. In 12 patients (75%), the initial fixation was assessed as being suboptimal. The primary surgery was regarded as adequate in only three patients. Our findings suggest that the most important determinant of nonunion of a distal humeral fracture after surgery is the adequacy of fixation.