Results 41 - 60 of 1508
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 184 - 191
1 Feb 2017
Pierrepont J Hawdon G Miles BP Connor BO Baré J Walter LR Marel E Solomon M McMahon S Shimmin AJ

Aims. The pelvis rotates in the sagittal plane during daily activities. These rotations have a direct effect on the functional orientation of the acetabulum. The aim of this study was to quantify changes in pelvic tilt between different functional positions. Patients and Methods. Pre-operatively, pelvic tilt was measured in 1517 patients undergoing total hip arthroplasty (THA) in three functional positions – supine, standing and flexed seated (the moment when patients initiate rising from a seated position). Supine pelvic tilt was measured from CT scans, standing and flexed seated pelvic tilts were measured from standardised lateral radiographs. Anterior pelvic tilt was assigned a positive value. Results. The mean pelvic tilt was 4.2° (-20.5° to 24.5°), -1.3° (-30.2° to 27.9°) and 0.6° (-42.0° to 41.3°) in the three positions, respectively. The mean sagittal pelvic rotation from supine to standing was -5.5° (-21.8° to 8.4°), from supine to flexed seated was -3.7° (-48.3° to 38.6°) and from standing to flexed seated was 1.8° (-51.8° to 39.5°). In 259 patients (17%), the extent of sagittal pelvic rotation could lead to functional malorientation of the acetabular component. Factoring in an intra-operative delivery error of ± 5° extends this risk to 51% of patients. Conclusion. Planning and measurement of the intended position of the acetabular component in the supine position may fail to predict clinically significant changes in its orientation during functional activities, as a consequence of individual pelvic kinematics. Optimal orientation is patient-specific and requires an evaluation of functional pelvic tilt pre-operatively. Cite this article: Bone Joint J 2017;99-B:184–91


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 725 - 727
1 Sep 1994
James P Butcher I Gardner E Hamblen D

We investigated the incidence of cephalosporin-resistant bacteria in infected hip arthroplasties. Of 740 patients having hip replacement or related procedures performed over three years, 30 had positive bacteriological cultures from tissue removed at the time of surgery. In 18 of the 30 cultures Staphylococcus epidermidis was grown and 12 of these were methicillin-resistant. A prospective study of skin swabs taken from 100 consecutive patients at the time of admission for THR showed methicillin-resistant Staphylococcus epidermidis in 25. This cephalosporin-resistant organism was shown to be the commonest proven cause of infection, and its presence as a skin commensal raises important questions about current antibiotic prophylaxis for joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 289 - 296
1 Aug 1975
Jones DA Lucas HK O"Driscoll M Price CHG Wibberley B

The significance of cobalt as a cause of symptoms after McKee hip arthroplasty is discussed. Seven patients are described in whom such arthroplasties became unsatisfactory after periods varying from nine months to four years. Six of these patients were cobalt-positive but nickel-and chrome-negative on patch testing. Macroscopic and histological necrosis of bone, muscle and joint capsule around the prostheses was found in five patients whose hips were explored. The symptoms were progressive pain, a feeling of instability, and in two cases spontaneous dislocation. Radiological features included acetabular fracture, bone resorption, loosening and dislocation of the prosthesis. Increased cobalt concentrations (determined by atomic absorption spectrophotometry) in the urine of four patients and in a variety of tissues in one patient are presented. Patch testing is recommended in the investigation of patients with troublesome McKee hip arthroplasties


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1623 - 1626
1 Dec 2008
Kulkarni A Partington P Kelly D Muller S

Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 475 - 478
1 May 1993
Lieberman Huo M Schneider R Salvati E Rodi S

We reviewed the plain radiographs, bone scans and hip aspiration results of 54 patients with painful hip arthroplasties which had been explored surgically, to compare the results of the investigations with the operative findings. For acetabular loosening, the sensitivity and specificity of bone scanning were 87% and 95%, with an accuracy of 90%: for serial plain radiography sensitivity was 95%, specificity 100% and accuracy 97%. For femoral component loosening, bone scan sensitivity was 85%, specificity 100% and accuracy 89%: the sensitivity of plain radiography was 100%, with specificity 92% and accuracy 98%. Technetium bone scanning did not provide additional information with regard to loosening and is not necessary in the routine investigation of a painful hip arthroplasty. Serial pain radiography is the most effective method of detecting loosening, and bone scanning is useful only when radiography is inconclusive with regard to loosening or infection


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 618 - 622
1 May 2005
Field RE Cronin MD Singh PJ

We have used the Oxford hip score to monitor the progress of 1908 primary and 279 revision hip replacements undertaken since the start of 1995. Our review programme began in early 1999 and has generated 3900 assessments. The mean pre-operative scores for primary and revision cases were 40.95 and 40.11, respectively. The mean annual score for primary replacement at between 12 and 84 months ranged between 20.60 and 22.57. A comparison of cross-sectional and longitudinal data showed no significant differences. All post-operative reviews showed a significant improvement (p ≤ 0.0001). The 50- to 60-year-old group scored significantly better than the patients over 80 years of age up to 48 months (p < 0.01). A subgroup of 826 National Health Service (NHS) and 397 private patients, treated by the senior author (2292 Oxford assessments), had a higher (i.e. worse) mean pre-operative score for the NHS patients (p ≤ 0.001). The private patients scored better than the NHS group up to 84 months (p < 0.05). Patients treated by a surgeon performing more than 100 replacements each year had a significantly better outcome up to five years than those operated on by surgeons performing fewer than 20 replacements each year. The age of the patients at the time of operation, and their pre-operative level of disability, have both been identified as affecting the long-term outcome. Awareness of the influence of these factors should assist surgeons to provide balanced advice


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1074 - 1077
1 Aug 2009
Singh VK Kalairajah Y

An intra-operative splash is a common occurrence in elective knee and hip replacement surgery and can potentially transmit bloodborne diseases, with devastating consequences. This study aimed to quantify the risk of a splash and to assess its correlation with body mass index, duration of surgery and the volume of lavage fluid used. Between December 2007 and April 2008, 62 consecutive patients (38 women, 24 men) undergoing an elective total knee or total hip replacement (TKR, THR) were recruited into the study (32 TKRs and 30 THRs) after appropriate consent. A splash occurred in all 62 cases. A THR had a slightly higher risk of a splash than a TKR, but this was not statistically significant (p = 0.27). The correlation between body mass index, duration of surgery and the amount of pulse lavage used with a splash was r = 0.013, (non-significant), r = 0.52, (significant) and r = 0.92 (highly significant), respectively. A high number of splashes are generated during a TKR and a THR. The simple visor mask fails to protect the surgeon, the assistant or the patient from the risk of a splash and reverse splash, respectively


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1128 - 1135
14 Sep 2020
Khoshbin A Haddad FS Ward S O hEireamhoin S Wu J Nherera L Atrey A

Aims

The rate of dislocation when traditional single bearing implants are used in revision total hip arthroplasty (THA) has been reported to be between 8% and 10%. The use of dual mobility bearings can reduce this risk to between 0.5% and 2%. Dual mobility bearings are more expensive, and it is not clear if the additional clinical benefits constitute value for money for the payers. We aimed to estimate the cost-effectiveness of dual mobility compared with single bearings for patients undergoing revision THA.

Methods

We developed a Markov model to estimate the expected cost and benefits of dual mobility compared with single bearing implants in patients undergoing revision THA. The rates of revision and further revision were calculated from the National Joint Registry of England and Wales, while rates of transition from one health state to another were estimated from the literature, and the data were stratified by sex and age. Implant and healthcare costs were estimated from local procurement prices and national tariffs. Quality-adjusted life-years (QALYs) were calculated using published utility estimates for patients undergoing THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 851 - 854
1 Jul 2009
Timperley AJ Whitehouse SL

Recently the National Patient Safety Agency in the United Kingdom published a report entitled “Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur”. A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 502 - 505
1 Nov 1980
Rooker G Wilkinson J

A prospective study of allergic contact dermatitis after metal-on-plastic total hip replacement was undertaken in 69 patients, of whom 54 were available for review after operation. Before operation six patients were metal sensitive, but only one remained so afterwards; this patient had given a clear history of metal sensitivity and a titanium prosthesis had therefore been used. In all six patients the result of the operation was good and no case of loosening occurred. Sixty-three patients had negative patch tests before operation; in none of these was metal sensitivity detected after operation. Cutaneous sensitivity to various metals is well documented after the insertion of metal-on-metal prostheses and in failed prostheses. We have not found any such increased sensitivity after metal-on-plastic hip replacement. There is little evidence of a direct causal relationship between metal sensitivity and subsequent loosening. The cutaneous sensitivity may be the consequence of loosening rather than its cause. Our results suggest that, providing metal-on-plastic prostheses are used, routine patch testing before hip replacement is no longer required


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1133 - 1135
1 Sep 2018
Pairon P Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 820 - 821
1 Jun 2009
Dabasia H Kokkinakis M El-Guindi M

A 66-year-old man presented with an infected resurfacing hip replacement in the immediate post-operative period following an uneventful transurethral resection of the prostate. Prophylactic antibiotics had been administered on induction of anaesthesia. The hip prosthesis had been inserted seven years previously and had been hitherto asymptomatic. The hip was washed out and microbiological examination identified Enterococcus faecalis as the infecting micro-organism. Despite current recommendations, clinicians undertaking invasive procedures which can lead to bacteraemia in patients with prosthetic joint replacements should be aware of the risk of haematogenous seeding in such prostheses, which although low, has potentially disastrous consequences


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 84 - 90
1 Jun 2019
Charette RS Sloan M Lee G

Aims

Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNFs), especially in physiologically younger patients. While THA for osteoarthritis (OA) has demonstrated low complication rates and increased quality of life, results of THA for acute FNF are not as clear. Currently, a THA performed for FNF is included in an institutional arthroplasty bundle without adequate risk adjustment, potentially placing centres participating in fracture care at financial disadvantage. The purpose of this study is to report on perioperative complication rates after THA for FNF compared with elective THA performed for OA of the hip.

Patients and Methods

The American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database between 2008 and 2016 was queried. Patients were identified using the THA Current Procedural Terminology (CPT) code and divided into groups by diagnosis: OA in one and FNF in another. Univariate statistics were performed. Continuous variables were compared between groups using Student’s t-test, and the chi-squared test was used to compare categorical variables. Multivariate and propensity-matched logistic regression analyses were performed to control for risk factors of interest.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 229 - 231
1 Mar 1985
Southwood R Rice J McDonald P Hakendorf P Rozenbilds M

The relationship between the route of inoculation, the dose of inoculum and the development of infection after prosthetic replacement has been determined in an animal model. The rabbit hip served as the model and a Staphylococcus aureus isolated from an infected human hip arthroplasty was introduced using different protocols. The 50% infective dose (ID50) was determined for comparative purposes. Contamination of the wound site with only a few bacteria was likely to result in infection. It was considerably more difficult to induce infection when the operation was performed without inserting the prosthesis, which suggests that the implant inhibits the body's mechanism for dealing with the insult. It was difficult to produce infection by inoculating the organisms into the bloodstream: if this inoculation was delayed till three weeks after operation the animals were often grossly septicaemic by the time the arthroplasty was infected. The results emphasise the importance of minimising intra-operative contamination and the efficacy of antibiotic cover


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 869 - 871
1 Nov 1993
Lieberman Moeckel B Evans B Salvati E Ranawat C

We reviewed 19 revision hip arthroplasties in which the new femoral component had been recemented into the old, intact cement mantle. The mean time from the first operation to revision was 64 months and the average follow-up was 59 months. There were 7 excellent, 11 good, and one fair result. No femoral component had been revised for loosening and all the stems appeared radiographically stable. Complications included intraoperative perforation of the femur on two occasions and one dislocation. The use of the cement-within-cement technique requires that the old cement surface be dry and roughened to increase the surface area and that the cement be injected in the liquid phase to prevent lamination. The indications for this technique include a broken stem with an intact distal cement mantle, the removal of a femoral component for revision of a loose cup to improve exposure and/or increase offset, recurrent dislocation secondary to component malposition, and debonding of the femoral component within an intact cement mantle


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 314 - 319
1 Mar 2005
Buttaro MA Pusso R Piccaluga F

Bone allografts can store and release high levels of vancomycin. We present our results of a two-stage treatment for infected hip arthroplasty with acetabular and femoral impaction grafting using vancomycin-loaded allografts. We treated 29 patients (30 hips) by removal of the implants, meticulous debridement, parenteral antibiotic therapy and second-stage reconstruction using vancomycin-supplemented impacted bone allografts and a standard cemented Charnley femoral component. The mean follow-up was 32.4 months (24 to 60). Infection control was obtained in 29 cases (re-infection rate of 3.3%; 95% confidence interval 0.08 to 17) without evidence of progressive radiolucent lines, demarcation or graft resorption. One patient had a further infection ten months after revision caused by a different pathogen. Associated post-operative complications were one traumatic periprosthetic fracture at 14 months, a single dislocation in two hips and four displacements of the greater trochanter. Vancomycin-supplemented allografts restored bone stock and provided sound fixation with a low incidence of further infection


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1061 - 1067
1 Aug 2005
Raman R Kamath RP Parikh A Angus PD

We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d’Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6°. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components


Bone & Joint Research
Vol. 7, Issue 8 | Pages 508 - 510
1 Aug 2018
Horriat S Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 435 - 438
1 May 1990
Scher M Jakim I

We present a new method of trochanter stabilisation designed for use in difficult revision hip arthroplasties. A fixator is secured to the metaphysis of the femur, and its two malleable prongs encompass the trochanter fragment and stabilise it using the tension band principle. The fixator is versatile, simple to apply and has better mechanical properties than any technique using wires. We reviewed 49 revisions after a mean follow-up of 40 months. Patients had been mobilised early, but there were no detachments or displacements from the initial postoperative position. Although 31% of patients were osteoporotic and 16% had poor trochanter fragments, there was bony union in 46 of the 49 hips, the remaining three developing stable fibrous union


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 326 - 331
1 Aug 1980
Macnicol M McHardy R Chalmers J

In 30 elderly women awaiting hip arthroplasty on account of unilateral osteoarthritis of the hip, walking speed and oxygen consumption were measured during a 12-minute test and the power output was calculated from the stair climbing rate. The results were compared with those for a group of 30 normal women of similar age. An age-related decline in maximal walking speed was observed in both groups. After arthroplasty there was a significant increase in maximal walking speed, particularly among the more disabled patients, with the major gain occurring by three months and a further slight increase by six months. Oxygen consumption returned towards normal values, and both stride length and cadence increased by a comparable degree. Mean power output during stair climbing doubled, and both before and after arthroplasty bore a linear relationship to the maximal walking speed