Instability is the leading complication in the first year after primary and revision total hip arthroplasty (THA) according to the England and Wales National Joint Registry report.1 Instability is also an ongoing problem throughout the lifetime of any hip prosthesis, particularly in high-risk groups.2 Large diameter bearings, dual mobility and constrained liners are increasingly used to minimise the risk of instability after THA and revision THA.3
Bousquet and Rambert4 introduced dual mobility (DM) bearing system more than 40 years ago. Dual mobility is a combination of two brilliant ideas in total hip arthroplasty, the low friction principle from Sir John Charnley,5 and large diameter mobile component in a highly polished acetabular liner seen in the McKee-Farrar prosthesis.6 In theory, this system can provide increased stability by adding an extra articulating interface without causing significant restriction in range of movement, unlike constrained liners. Biomechanical studies confirm the stability advantage of these implants compared with other options.7
Early clinical reports, mainly from France, showed that DM can reduce dislocation rates in primary THA.8,9 This is supported by more recent data from newer DM hips.10 It seems increasingly clear that using dual mobility is likely to offer advantages to patients. This would include particularly those patients who are at higher risk of instability, either due to lack of muscle control, neuromuscular issues, soft-tissue problems, or spinopelvic balance problems.11,12
We are increasingly faced with elderly fractured neck of femur patients who require THA, and these patients would be ideal for the further study of this problem. There have been difficulties delivering such studies,13 but healthcare systems that have rotas in place to deliver THA acutely for fracture may allow us to do those studies and, ultimately, understand the safety, efficacy and the cost-effectiveness of using dual mobility in high-risk populations.14
Emerging clinical results of DM bearing systems used in revision THA show better mid-term survival and a lower dislocation rate compared with standard fixed bearings used for revision THA.3,10,15 Good short- and mid-term clinical outcomes have encouraged surgeons to use DM more frequently. In one European joint registry, DM systems have been used in two thirds of first time revision THAs for instability.16
In theory, DM bearing surface made of a large polyethylene (PE) ball articulating with a smaller size head in its core and a polished acetabular liner on its outer surface, could cause more volumetric wear compared with standard THA, and in turn, it could cause more aseptic loosening. In newer generations of DM hips, highly cross-linked PE has been used to minimise PE wear in both inner and outer bearing interfaces. Examination of retrieved PE liners used in modern DM hips has shown similar wear rates as PE liners used in standard THA.10,17,18 Reduced PE wear at the inner head/PE ball interface has also contributed to a reduction of intra-prosthetic dissociation (IPD), a complication almost specific to DM systems. IPD is disarticulation of the small head from the inner side of the large PE ball. PE wear and failure of coupling mechanism between the 22 mm head and the PE ball were the main reasons for IPD. Using larger heads (28 mm instead of 22 mm) in the newer generations of the dual mobility bearings with highly cross-linked PE liners has almost completely eliminated IPD.10
There are now multiple designs available, some cemented and some as liners to be inserted into cementless shells. Most new designs take 28 mm heads and smaller.10 Only a few have a proven track record and there is no long-term published clinical data on many designs. There are few comparative clinical studies on the expanded clinical use of DM bearing that demonstrate superior clinical outcomes compared with THA with a fixed bearing, particularly when larger diameter heads (32 or 36 mm) are used. Whilst clinical studies are rare in the literature, biomechanical studies on DM bearings conclude wider acetabular safe zone and larger jump distance for these implants.19,20 Any conclusion of these studies that suggests the biomechanical advantage of DM bearings should not create the wrong impression that it can compensate for a lack of surgical skill. It is important that surgeons still implant the components in the best possible position for each individual patient.21
Adverse soft-tissue reactions to metal debris have however become a concern, with caution regarding the release of metal ion levels in dual mobility hips,22 particularly with the increased use of these implants in cementless shells, and with our increased understanding of taper corrosion.23,24 However, Tarity et al25 reported no particular pattern of corrosion or fretting on the retrieved components from 18 dual mobility hips. Similarly, Barlow et al26 assessed metal ion levels in four different bearing systems in THA, including dual mobility (excluding metal on metal hips), and concluded that metal ion levels in modern THA systems were not significantly different, although THA with a metal head showed higher metal ion levels compared with THA with ceramic heads. Thus, it is worth considering the use of ceramic or ‘ceramicized’ metal heads in this setting.
The use of DM may also vary depending on the size of the patient. There may, for example, be limited benefits in patients with small acetabular components. In such patients, the use of a large head will probably afford similar protection.
With good reported clinical outcomes and particularly low dislocation rates, as well as improved design of the implants in order to minimise the known complications, DM bearings have become more and more popular. However, despite the increasing use of DM bearings, the English language literature is lacking robust evidence to refine clinical indications for DM in primary and revision hip arthroplasty. In a recent systematic review, almost all of the included studies on DM were retrospective case series.11
In dual mobility, we have a clever established solution that helps in both primary and revision hip arthroplasty.10 It has transitioned from a niche product to one in regular use, but requires careful scrutiny of the data on the currently available implants, high-level studies, and review of registry data in order to ensure that we are not creating new problems. It is our responsibility to embrace this technology and ensure that it is applied effectively. The need for more data should not delay its responsible introduction into clinical practice, provided surgeons continue to choose their implants judiciously, apply good surgical technique, and select implants and patients appropriately.
Open access
This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
None declared
None declared
Follow us @BoneJointRes
References
1. No authors listed. National Joint Registry: 10th Annual Report, National Joint Registry for England, Wales and Northern Ireland, 2013. http://www.njrreports.org.uk/Portals/0/PDFdownloads/NJR%2014th%20Annual%20Report%202017.pdf (date last accessed 12 May 2018). Google Scholar
2. Sheth NP , Melnic CM , Paprosky WG . Evaluation and management of chronic total hip instability. Bone Joint J2016;98-B(1 Supple A):44-49.CrossrefPubMed Google Scholar
3. De Martino I , D’Apolito R , Soranoglou VG et al. . Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review. Bone Joint J2017;99-B(1 Supple A):18-24.CrossrefPubMed Google Scholar
4. Bousquet G , Bornand F . A screw-anchored intramedullary hip prosthesis. In the cementless fixation of hip endoprostheses. Springer, Berlin, Heidelberg;1984:242-246. Google Scholar
5. Charnley J . The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg [Br]1972;54-B:61-76.PubMed Google Scholar
6. McKee GK , Watson-Farrar J . Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg [Br]1966;48-B:245-259.PubMed Google Scholar
7. Terrier A , Latypova A , Guillemin M , Parvex V , Guyen O . Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis. Int Orthop2017;41:551-556.CrossrefPubMed Google Scholar
8. Lautridou C , Lebel B , Burdin G , Vielpeau C . Survival of the cementless Bousquet dual mobility cup: minimum 15-year follow-up of 437 total hip arthroplasties. Rev Chir Orthop Reparatrice Appar Mot2008;94:731-739. Google Scholar
9. Farizon F , De Lavison R , Azoulai JJ , Bousquet G . Results with a cementless alumina-coated cup with dual mobility. Int Orthop1998;22:219-224.CrossrefPubMed Google Scholar
10. Darrith B , Courtney PM , Della Valle CJ . Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature. Bone Joint J2018;100-B:11-19.CrossrefPubMed Google Scholar
11. Ko LM , Hozack WJ . The dual mobility cup: what problems does it solve?Bone Joint J2016;98-B(1 Supple A):60-63.CrossrefPubMed Google Scholar
12. Stefl M , Lundergan W , Heckmann N et al. . Spinopelvic mobility and acetabular component position for total hip arthroplasty. Bone Joint J2017;99-B(1 Supple A):37-45.CrossrefPubMed Google Scholar
13. Griffin XL , Parsons N , Achten J , Costa ML . A randomised feasibility study comparing total hip arthroplasty with and without dual mobility acetabular component in the treatment of displaced intracapsular fractures of the proximal femur: The Warwick Hip Trauma Evaluation Two: WHiTE Two. Bone Joint J2016;98-B:1431-1435. Google Scholar
14. Huxley C , Achten J , Costa ML , Griffiths F , Griffin XL . A process evaluation of the WHiTE Two trial comparing total hip arthroplasty with and without dual mobility component in the treatment of displaced intracapsular fractures of the proximal femur: Can a trial investigating total hip arthroplasty for hip fracture be delivered in the NHS?Bone Joint Res2016;5:444-452.CrossrefPubMed Google Scholar
15. Harwin SF , Sultan AA , Khlopas A , Chughtai M , Sodhi N , Piuzzi NS , Mont MA . Mid-term outcomes of dual mobility acetabular cups for revision total hip arthroplasty. J Arthroplasty2018;3:1494-1500.CrossrefPubMed Google Scholar
16. Stucinskas J , Kalvaitis T , Smailys A , Robertsson O , Tarasevicius S . Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register. Int Orthop2018;42:1015-1020.CrossrefPubMed Google Scholar
17. Callary SA , Field JR , Campbell DG . The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used. Bone Joint J2016;98-B:1604-1610. Google Scholar
18. Adam P , Farizon F , Fessy MH . Dual mobility retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Orthop Traumatol Surg Res2014;100:85-91.CrossrefPubMed Google Scholar
19. Ohmori T , Kabata T , Maeda T et al. . Increase in safe zone area of the acetabular cup using dual mobility cups in THA. Hip Int2017;27:361-367.CrossrefPubMed Google Scholar
20. Nevelos J , Johnson A , Heffernan C et al. . What factors affect posterior dislocation distance in THA?. Clin Orthop Relat Res2013;471:519-526.CrossrefPubMed Google Scholar
21. Grammatopoulos G , Thomas GE , Pandit H et al. . The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J2015;97-B:164-172.CrossrefPubMed Google Scholar
22. Vahedi H , Makhdom AM , Parvizi J . Dual mobility acetabular cup for total hip arthroplasty: use with caution. Expert Rev Med Devices2017;14:237-243.CrossrefPubMed Google Scholar
23. Lash NJ , Whitehouse MR , Greidanus NV et al. . Delayed dislocation following metal-on-polyethylene arthroplasty of the hip due to ‘silent’trunnion corrosion. Bone Joint J2016;98-B:187-193. Google Scholar
24. Osman K , Panagiotidou AP , Khan M , Blunn G , Haddad FS . Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head–neck junctions. Bone Joint J2016;98-B:579-584. Google Scholar
25. Tarity TD , Koch CN , Burket JC , Wright TM , Westrich GH . Fretting and corrosion at the backside of modular cobalt chromium acetabular inserts: a retrieval analysis. J Arthroplasty2017;32:1033-1039.CrossrefPubMed Google Scholar
26. Barlow BT , Ortiz PA , Boles JW et al. . What are normal metal ion levels after total hip arthroplasty? a serologic analysis of four bearing surfaces. J Arthroplasty2017;32:1535-1542. Google Scholar