We report the contamination rate in the Cambridge bone bank of 35 consecutive
From November 1994 to March 1997, we harvested 137 grafts of the femoral head from 125 patients for donation during total hip arthroplasty according to the guidelines of the American Associations of Tissue Banks (AATB) and the European Association of Musculo-Skeletal transplantation (EAMST). In addition to the standards recommended by these authorities, we performed histopathological examination of a core biopsy of the retrieved bone
Glenoid replacement is technically challenging. Removal of a cemented glenoid component often results in a large osseous defect which makes the immediate introduction of a revision prosthesis almost impossible. We describe a two-stage revision procedure using a reversed shoulder prosthesis. Freeze-dried
This study reports the clinical outcome of reconstruction
of deficient abductor muscles following revision total hip arthroplasty
(THA), using a fresh–frozen
Previously, radiostereometric analysis following hip revision performed using impacted morsellised
Implantation of
Several techniques have been described to reconstruct a mobile wrist joint after resection of the distal radius for tumour. We reviewed our experience of using an osteo-articular
An analysis of the cement mantle obtained with the Exeter impaction
We assessed the results of 17 limb-salvage procedures using osteoarticular
We investigated the radiographic and clinical course of 31 patients in whom a bulk acetabular
The aim of limb-salvage surgery in malignant bone tumours in children is to restore function and eradicate local disease with as little morbidity as possible. Allografts are associated with a high rate of complications, particularly malunion at the allograft-host junction. We describe a simple technique which enhances union of
This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction
The use of
We report the long-term results of revision total
hip replacement using femoral impaction
A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement.
The treatment of a chronic posterior dislocation of the shoulder is often determined by the size of the associated impression fracture of the humeral head. Our hypothesis was that patients with a chronic unreduced posterior dislocation of the shoulder and a defect in the humeral head involving between 25% to 50% of the articular surface, would do better if reconstructed with an
Five vascularised
We present the histological findings of an extensor mechanism
Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%). Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years. Acetabular reconstruction using irradiated
We compared growth in vascularised