Advertisement for orthosearch.org.uk
Results 41 - 60 of 956
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 170 - 176
1 Feb 2020
Bernthal NM Burke ZDC Hegde V Upfill-Brown A Chen CJ Hwang R Eckardt JJ

Aims. We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction. Methods. This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with all-polyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up. Results. A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 all-polyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Age-stratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%). Conclusion. The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients. Cite this article: Bone Joint J. 2020;102-B(2):170–176


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims. The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery. Methods. A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA. Results. Survivorship at ten years was 97% in both the ACL-deficient and ACL-intact groups. The mean survival was 16.1 years (95% confidence interval (CI) 15.3 to 16.8) for the ACL-deficient group and 15.6 years (95% CI 14.8 to 16.361) for the ACL-intact group (p = 0.878). At a mean of nine years (SD 3.5) in the ACL-deficient group, 32 patients (87%) reached the PASS for the KOOS ADL. In the ACL-intact group, at a mean of 8.6 years (SD 3) follow-up, 63 patients (85%) reached PASS for the KOOS ADL. There was no significant difference in the percentage of patients who reached PASS for all KOOS subscales and Lysholm between the two groups. Conclusion. PASS was achieved in 85% of all UKAs for KOOS ADL, similar to reports for TKA. Fixed-bearing, medial, non-robotically-assisted UKA resulted in 97% survival at ten years in both the ACL-deficient and ACL-intact groups. There was no significant difference in all outcomes between the two groups. Understanding PASS will allow better communication between surgeons and patients to improve the surgical management of patients with single compartment OA of the knee. This study provides mid- to long-term data supporting the use of PASS to document outcomes following UKA. PASS was met in more than 85% of patients with no differences between ACL-deficient and ACL-intact knees at a mean follow-up of nine years. Cite this article: Bone Joint J 2021;103-B(8):1367–1372


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 121 - 129
1 Mar 2024
Orce Rodríguez A Smith PN Johnson P O'Sullivan M Holder C Shimmin A

Aims

In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA).

Methods

Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups.


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 16 - 22
1 Jun 2019
Livermore AT Anderson LA Anderson MB Erickson JA Peters CL

Aims. The aim of this study was to compare patient-reported outcome measures (PROMs), radiological measurements, and total hip arthroplasty (THA)-free survival in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip. Patients and Methods. We performed a retrospective study involving 336 patients (420 hips) who underwent PAO by a single surgeon at an academic centre. After exclusions, 124 patients (149 hips) were included. The preoperative lateral centre-edge angle (LCEA) was used to classify the severity of dysplasia: 18° to 25° was considered mild (n = 20), 10° to 17° moderate (n = 66), and < 10° severe (n = 63). There was no difference in patient characteristics between the groups (all, p > 0.05). Pre- and postoperative radiological measurements were made. The National Institute of Health’s Patient Reported Outcomes Measurement Information System (PROMIS) outcome measures (physical function computerized adaptive test (PF CAT), Global Physical and Mental Health Scores) were collected. Failure was defined as conversion to THA or PF CAT scores < 40, and was assessed with Kaplan–Meier analysis. The mean follow-up was five years (2 to 10) ending in either failure or the latest contact with the patient. Results. There was no significant difference in PROMs for moderate (p = 0.167) or severe (p = 0.708) groups compared with the mild dysplasia group. The numerical pain scores were between 2 and 3 units in all groups at the final follow-up (all, p > 0.05). There was no significant difference (all, p > 0.05) in the proportion of patients achieving target correction for the LCEA between groups. The mean correction was 12° in the mild, 15° in the moderate (p = 0.135), and 23° in the severe group (p < 0.001). Failure-free survival at five years was 100% for mild, 79% for moderate, and 92% for severely dysplastic hips (p = 0.225). Conclusion. Although requiring less correction than hips with moderate or severe dysplasia, we found PAO for mild dysplasia to be associated with promising PROMs, consistent with that of the general United States population, and excellent survivorship at five years. Future studies should compare these results with the outcome after arthroscopy of the hip in patients with mild dysplasia. Cite this article: Bone Joint J 2019;101-B(6 Supple B):16–22


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims. Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. Materials and Methods. A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties. Results. A total of 28 studies were eligible for inclusion. This included 5322 hips in 4657 patients with a mean age of 59 years (13 to 94). The mean follow-up was 6.1 years (0.5 to 20). The mean Harris Hip Score improved from 46 (0 to 100) to 92 (39 to 100). The mean Oxford Hip Score improved from 25 (2 to 42.5) to 35 (12.4 to 48). The mean Western Ontario & McMaster Universities Osteoarthritis Index improved from 54 (2 to 95) to 22 (0 to 98). Components were aligned in a neutral coronal alignment in up to 90.9% of cases. A total of 15 studies reported component survivorship, which was 98.6% (92% to 100%) at a mean follow-up of 12.1 years. Conclusion. Short-stemmed femoral implants show similar improvement in clinical and radiological outcomes compared with conventional length implants. Only mid-term survivorship, however, is known. An abundance of short components have been developed and used commercially without staged clinical trials. Long-term survival is still unknown for many of these components. There remains tension between innovation and the moral duty to ensure that the introduction of new implants is controlled until safety and patient benefit are demonstrated. Implant innovation and subsequent use should be driven by proven clinical outcomes, rather than market and financial forces, and ethical practice must be ensured. Cite this article: Bone Joint J 2019;101-B:502–511


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 946 - 949
1 Jul 2005
Talwalkar SC Givissis PK Trail IA Nuttall D Stanley JK

We divided 309 patients with an inflammatory arthritis who had undergone primary elbow replacement using the Souter-Strathclyde implant into two groups according to their age. The mean follow-up in the older group (mean age 64 years) was 7.3 years while in the younger patients (mean age 42 years) it was 12 years. Survivorship for three different failure end-points (revision, revision because of aseptic loosening of the humeral component, and gross loosening of the humeral implant), was compared in both groups. Our findings showed that there was no significant difference in the incidence of loosening when young rheumatoid patients were compared with an older age group


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 276 - 284
1 Mar 1987
Bradish C Kemp H Scales J Wilson J

We report the long-term clinical follow-up and survivorship analysis of 40 distal femoral replacements performed between 1964 and 1980 for traumatic, locally aggressive and malignant conditions. Custom-made prostheses with fully-constrained knee joints were used to replace a mean of 42% of the length of the femur. Survivorship analysis showed a cumulative success rate of 80% at eight years, with no subsequent deterioration at 18 years. Clinical assessment revealed 78% excellent or good results. Failure was due to infection in three cases, and in two to fracture of a now-outmoded femoral stem


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 790 - 795
1 Jun 2006
Ahlmann ER Menendez LR Kermani C Gotha H

We reviewed retrospectively the results in 211 consecutive patients who had undergone limb salvage for bone neoplasia with endoprosthetic reconstruction of the proximal femur (96), distal femur (78), proximal tibia (30) and total femur (7). Their mean age was 50 years (11 to 86) and the mean follow-up period was 37.3 months (1 to 204). A total of 35 (16.6%) prostheses failed. Overall, implant survival was 78% (95% confidence interval (CI) 0.29 to 0.54) at five years, 60% (95% CI 0.93 to 2.35) at ten years and 60% (95% CI 1.27 to 3.88) at 15 years. Survivorship of the limb was 97.6% (95% CI 1.73 to 3.35) at ten years. The gender, age, diagnosis and location of the tumour were not prognostic variables for failure. Modular endoprosthetic replacement in the lower limb is a durable long-term reconstructive option, with the implants generally outlasting the patient


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 724 - 731
1 Jun 2017
Mei-Dan O Jewell D Garabekyan T Brockwell J Young DA McBryde CW O’Hara JN

Aims. The aim of this study was to evaluate the long-term clinical and radiographic outcomes of the Birmingham Interlocking Pelvic Osteotomy (BIPO). Patients and Methods. In this prospective study, we report the mid- to long-term clinical outcomes of the first 100 consecutive patients (116 hips; 88 in women, 28 in men) undergoing BIPO, reflecting the surgeon’s learning curve. Failure was defined as conversion to hip arthroplasty. The mean age at operation was 31 years (7 to 57). Three patients (three hips) were lost to follow-up. Results. Survivorship was 76% at ten years and 57% at a mean of 17 years. Younger patients (< 20 years) had the best survivorship (20 hips at risk; 90% at 17 years; 95% confidence interval 65 to 97). Post-operative complications occurred after 12 operations (10.4%) over the duration of the study. Increasing patient age and hip arthritis grade were primary determinants of surgical failure. Conclusion. BIPO provides good to excellent survivorship in appropriately selected patients, with a relatively low rate of complications. Our results are comparable with other established methods of periacetabular osteotomy (PAO), such as the Bernese PAO, even during the surgeon’s initial learning curve. Cite this article: Bone Joint J 2017;99-B:724–31


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 798 - 803
1 Nov 1989
Scuderi G Insall J Windsor R Moran M

The survivorship method of analysis has been used to compare the failure rate and overall success of 1,430 cemented primary total knee arthroplasties performed at The Hospital for Special Surgery over a 15-year period. There were 224 total condylar prostheses with a polyethylene tibia, 289 of the posterior stabilised type with an all polyethylene tibia, and 917 posterior stabilised with a metal-backed tibial component. There were 12 failures in the total condylar series, giving an average annual failure rate of 0.65% and a 15-year success rate of 90.56%. The posterior stabilised prosthesis with a polyethylene tibia showed an average annual failure rate of 0.27% and a 10-year success rate of 97.34%, and this prosthesis with a metal-backed tibial component gave an annual failure rate of 0.19% and a seven-year success rate of 98.75%. The overall survival rate was not influenced by sex or age, diagnosis or the percentage of ideal body weight. No metal-backed tibial components have yet needed revision for loosening. It seems that infection will be the major cause of failure


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 414 - 422
1 Apr 2020
Gwynne-Jones DP Gray AR

Aims. To compare long-term survival of all-cemented and hybrid total hip arthroplasty (THA) using the Exeter Universal stem. Methods. Details of 1,086 THAs performed between 1999 and 2005 using the Exeter stem and either a cemented (632) or uncemented acetabular component (454) were collected from local records and the New Zealand Joint Registry. A competing risks regression survival analysis was performed with death as the competing risk with adjustments made for age, sex, approach, and bearing. Results. There were 61 revisions (9.7%; 0.82 revisions/100 observed component years, (OCYs)) in the all-cemented group and 18 (4.0%; 0.30/100 OCYs) in the hybrid group. The cumulative incidence of revision at 18 years was 12.1% for cemented and 5.2% for hybrids. There was a significantly greater risk of revision for all-cemented compared with hybrids (unadjusted sub-hazard ratio (SHR) 2.44; p = 0.001), and of revision for loosening, wear, or osteolysis (unadjusted SHR 3.77; p < 0.001). After adjustment, the increased risk of all-cause revision did not reach significance at age 70 years and above. The advantage for revision for loosening, wear, and osteolysis remained at all ages. Conclusion. This study supports the use of uncemented acetabular fixation when used in combination with the Exeter stem with improved survivorship for revision for aseptic loosening, wear, and osteolysis at all ages and for all-cause revision in patients less than 70 years. Cite this article: Bone Joint J 2020;102-B(4):414–422


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 875 - 881
1 Jul 2018
Newman JM Khlopas A Sodhi N Curtis GL Sultan AA George J Higuera CA Mont MA

Aims. This study compared multiple sclerosis (MS) patients who underwent primary total hip arthroplasty (THA) with a matched cohort. Specifically, we evaluated: 1) implant survivorship; 2) functional outcomes (modified Harris Hip Scores (mHHS), Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS JR), and modified Multiple Sclerosis Impact Scale (mMSIS) scores (with the MS cohort also evaluated based on the disease phenotype)); 3) physical therapy duration and return to function; 4) radiographic outcomes; and 5) complications. Patients and Methods. We reviewed our institution’s database to identify MS patients who underwent THA between January 2008 and June 2016. A total of 34 MS patients (41 hips) were matched in a 1:2 ratio to a cohort of THA patients who did not have MS, based on age, body mass index (BMI), and Charlson/Deyo score. Patient records were reviewed for complications, and their functional outcomes and radiographs were reviewed at their most recent follow-up. Results. Compared with the matched cohort, MS patients had lower all-cause implant survivorship at eight years (91.5% (95% confidence interval (CI) 82.7 to 100) vs 98.7% (95% CI 96.2 to 100)) (p = 0.033), lower mHHS scores (66 vs 80, p < 0.001), and HOOS JR scores (79 vs 88, p = 0.009). Multiple sclerosis patients also required more physiotherapy (five weeks vs three weeks, p = 0.002) and took longer to return to baseline (seven weeks vs five weeks, p = 0.010) than the matched cohort. Furthermore, MS patients had more complications than the non-MS patients (six vs zero, p < 0.001). The worse outcomes of the MS group can potentially be explained by predisposition of these patients to mechanical complications and progression of their disease during the period of this study, as demonstrated by worsening of the mMSIS scores (2.9 vs 3.4; p = 0.008). Conclusion. MS patients had lower implant survivorship, lower functional outcome scores, and increased complication rates; in addition, MS patients took longer to return to their baseline functional level after THA. Cite this article: Bone Joint J 2018;100-B:875–81


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1010 - 1013
1 Nov 1990
Werners R Vincent B Bulstrode C

We have reviewed 368 osteotomies carried out for osteoarthritis of the hip at the Nuffield Orthopaedic Centre. Survivorship analysis showed that 10 years after osteotomy 47% had required no further surgery, and even after 20 years 23% had still not had a hip replacement. Hips with moderate arthritic change showed significantly better results than those with more severe degeneration. Osteotomies with varus angulation as well as medial displacement showed longer survival


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 160 - 163
1 Feb 2015
Biemond JE Venkatesan S van Hellemondt GG

The long-term survival of the cementless Spotorno CLS femoral component in patients aged > 50 years at the time of arthroplasty was investigated. Survivorship analysis of a consecutive series of 85 patients (100 hips; under 50 years of age at a mean follow-up of 18.4 years (16.3 to 20.8)) was performed. The clinical and radiographic outcomes were satisfactory. The overall rate of survival of the femoral component was 93.5% (95% confidence interval (CI), 90.9 to 96.1) after 19 years. Survival with revision for aseptic loosening as the end point was 95.7% (95% CI 93.6 to 97.8%) at 19 years. . This study demonstrates an excellent long-term survival of the Spotorno CLS femoral component after 16 to 20 years in young patients undergoing total hip arthroplasty. . Cite this article: Bone Joint J 2015;97-B:160–3


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1002 - 1006
1 Sep 2004
Trail IA Martin JA Nuttall D Stanley JK

We reviewed the records and radiographs of 381 patients with rheumatoid arthritis who had undergone silastic metacarpophalangeal joint replacement during the past 17 years. The number of implants was 1336 in the course of 404 operations. Implant failure was defined as either revision or fracture of the implant as seen on radiography. At 17 years, the survivorship was 63%, although on radiographs two-thirds of the implants were seen to be broken. Factors which improved survival included soft-tissue balancing, crossed intrinsic transfer and realignment of the wrist. Surgery to the thumb and proximal interphalangeal joint had a deleterious effect and the use of grommets did not protect the implant from fracture


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims

Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up.

Methods

We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 658 - 663
1 Jul 1990
Sedel L Kerboull L Christel P Meunier A Witvoet J

Total hip replacement using an alumina head and socket and a titanium alloy stem is evaluated in a series of patients under 50 years of age. Between April 1977 and December 1986, 86 such replacements were performed in 75 patients, but mainly because patients had difficulty travelling from Africa, only 71 hips were followed up adequately; of these, 56 were primary procedures and 15 revisions. Survivorship analysis showed that 98% of the prostheses were retained for 10 years. On clinical and radiological examination 51 of the 71 hips were stable and acceptable, 15 had radiological changes on the acetabular side, and one on the femoral side; four other cases had clinical and radiological changes suggesting impending failure, possibly because fixation of the socket was inadequate. There were no differences between the results of the primary procedures and those of revisions. In these young patients, the results seem better with alumina-on-alumina hips than with other varieties, possibly because of their remarkably low wear


Bone & Joint Open
Vol. 3, Issue 11 | Pages 867 - 876
10 Nov 2022
Winther SS Petersen M Yilmaz M Kaltoft NS Stürup J Winther NS

Aims

Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS).

Methods

Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims

When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR).

Methods

A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 733 - 739
1 Jun 2018
DeDeugd CM Perry KI Trousdale WH Taunton MJ Lewallen DG Abdel MP

Aims. The aims of this study were to determine the clinical and radiographic outcomes, implant survivorship, and complications of patients with a history of poliomyelitis undergoing total hip arthroplasty (THA) in affected limbs and unaffected limbs of this same population. Patients and Methods. A retrospective review identified 51 patients (27 male and 24 female, 59 hips) with a mean age of 66 years (38 to 88) and with the history of poliomyelitis who underwent THA for degenerative arthritis between 1970 and 2012. Immigrant status, clinical outcomes, radiographic results, implant survival, and complications were recorded. Results. In all, 32 THAs (63%) were performed on an affected limb, while 27 (37%) were performed on an unaffected limb. The overall ten-year survivorship free from aseptic loosening, any revision, or any reoperation were 91% (95% CI 0.76 to 0.99), 91% (95% CI 0.64 to 0.97) and 87% (95% CI 0.61 to 0.95), respectively. There were no revisions for prosthetic joint infection. There were no significant differences in any of the above parameters if THA was on the affected or unaffected control limbs. Conclusion. Patients with a history of poliomyelitis who undergo THA on the affected or unaffected limbs have similar results with overall survivorship and complication rates to those reported results in patients undergoing THA for osteoarthritis. At long-term follow-up, previous clinical concerns about increased hip instability due to post-polio abductor weakness were not observed. Cite this article: Bone Joint J 2018;100-B:733–9