The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 428 - 432
1 Aug 1983
Vegter J van den Broek J

A diastasis between the femoral head and the acetabulum can be achieved for a short while by the application of manual traction on the lower extremity. The intra-articular low-pressure area can be visualised radiographically and is known as a "vacuum phenomenon". The resulting arthrogram clearly outlines the shape, thickness and extent of the cartilage. In the presence of an effusion the diastasis occurs without a vacuum phenomenon. This simple, non-invasive and inoffensive method of traction radiography will not only show abnormalities of the cartilage but also demonstrate the presence or absence of an effusion of the hip


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1069 - 1073
1 Aug 2016
Stirling E Jeffery J Johnson N Dias J

Aims

The degree of displacement of a fracture of the distal radius is an important factor which can be assessed using simple radiographic measurements. Our aim was to investigate the reliability and reproducibility of these measurements and to determine if they should be used clinically.

Patients and Methods

A 10% sample was randomly generated from 3670 consecutive adult patients who had presented to University Hospitals of Leicester NHS Trust between 2007 and 2010 with a fracture of the distal radius. Radiographs of the 367 patients were assessed by two independent reviewers. Four measurements of displacement of the fracture were recorded and the inter-observer correlation assessed using the intra-class correlation coefficient.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 302 - 304
1 Mar 1988
Bobyn J Engh C Glassman A

Threaded acetabular components are widely used in cementless total hip replacement, despite a poor understanding of the nature of the bone-implant interface. We have examined one case in which the threaded titanium ring appeared to be well incorporated with no discernible radiolucency. Microradiography and histology surprisingly showed that the threads were entirely encapsulated in fibrous tissue. This raises doubt about the relevance of plain radiography to the analysis of the acetabular interface


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 757 - 760
1 Sep 1990
Mulroy R Harris W

Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of radiographic loosening on the acetabular side was 42%. Improved cementing techniques have produced a marked reduction in the rate of aseptic loosening of the femoral component, but the incidence of acetabular loosening is unchanged


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1498 - 1502
1 Nov 2014
Riis A Rathleff MS Jensen MB Simonsen O

The optimal timing of total knee replacement (TKR) in patients with osteoarthritis, in relation to the severity of disease, remains controversial. This prospective study was performed to investigate the effect of the severity of osteoarthritis and other commonly available pre- and post-operative clinical parameters on the clinical outcome in a consecutive series of cemented TKRs. A total of 176 patients who underwent unilateral TKR were included in the study. Their mean age was 68 years (39 to 91), 63 (36%) were male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence osteoarthritis scale. A total of 154 patients (87.5%) returned for clinical review 12 months post-operatively, at which time the outcome was assessed using the Knee Society score.

A low radiological severity of osteoarthritis was not associated with pain 12 months post-operatively. However, it was significantly associated with an inferior level of function (p = 0.007), implying the need for increased focus on all possible reasons for pain in the knee and the forms of conservative treatment which are available for patients with lower radiological severity of osteoarthritis.

Cite this article: Bone Joint J 2014; 96-B:1498–1502.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 458 - 464
1 Apr 2017
Abrahams JM Kim YS Callary SA De Ieso C Costi K Howie DW Solomon LB

Aims

This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria.

Patients and Methods

Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 235 - 239
1 Mar 1994
Nilsson L Frazen H Carlsson A Onnerfalt R

We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with radiographic signs of prosthetic loosening had significant reductions in function and quality of life as measured by the NHP questionnaire, but no differences in the mean Charnley hip scores. None of the eight patients had clinical signs of prosthetic loosening sufficient to recommend revision of their THR. The NHP is a relatively low-cost method of providing long-term follow-up of THR


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 706 - 713
1 May 2013
Westberry DE Davids JR Anderson JP Pugh LI Davis RB Hardin JW

At our institution surgical correction of symptomatic flat foot deformities in children has been guided by a paradigm in which radiographs and pedobarography are used in the assessment of outcome following treatment. Retrospective review of children with symptomatic flat feet who had undergone surgical correction was performed to assess the outcome and establish the relationship between the static alignment and the dynamic loading of the foot.

A total of 17 children (21 feet) were assessed before and after correction of soft-tissue contractures and lateral column lengthening, using standardised radiological and pedobarographic techniques for which normative data were available.

We found significantly improved static segmental alignment of the foot, significantly improved mediolateral dimension foot loading, and worsened fore-aft foot loading, following surgical treatment. Only four significant associations were found between radiological measures of static segmental alignment and dynamic loading of the foot.

Weakness of the plantar flexors of the ankle was a common post-operative finding. Surgeons should be judicious in the magnitude of lengthening of the plantar flexors that is undertaken and use techniques that minimise subsequent weakening of this muscle group.

Cite this article: Bone Joint J 2013;95-B:706–13.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 462 - 463
1 Apr 2000
SUTHERLAND AG BAKER AR


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 632 - 635
1 Jul 1999
Davies AP Calder DA Marshall T Glasgow MMS

We took posteroanterior weight-bearing radiographs, both with the joint fully extended and in 30° of flexion, in a consecutive series of 50 knees in 37 patients referred for the primary assessment of pain and/or stiffness. These radiographs were reported ‘blind’ both by an orthopaedic surgeon and a radiologist. Direct measurement of the joint space, together with grading of the severity of erosion according to the Ahlback criteria, was undertaken. Any other abnormality present was also documented.

The radiographs of the knees in 30° of flexion consistently showed more advanced erosion in both the medial (p = 0.001) and the lateral (p = 0.0001) tibiofemoral compartments, when compared with those of knees in full extension. The Ahlback classification of 25 joints was altered, in some cases by several grades, by the flexed position of the joint. In every case in which another abnormality was identified on the radiograph in full extension, it was also noted on that of the knee in 30° of flexion. In a further four cases, additional pathology could only be seen in the flexed knee. Every patient was able to complete the radiological examination without difficulty. Our study supports the adoption of a weight-bearing view in 30° of flexion as the standard posteroanterior radiograph for the assessment of tibiofemoral osteoarthritis in patients over 50 years of age.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 338 - 338
1 Mar 1987
Horsfield D Jones S


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 136 - 141
1 Jan 2010
Franken M Grimm B Heyligers I

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value.

Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 279 - 285
1 Feb 2013
Engesæter IØ Laborie LB Lehmann TG Fevang JM Lie SA Engesæter LB Rosendahl K

In Norway total joint replacement after hip dysplasia is reported more commonly than in neighbouring countries, implying a higher prevalence of the condition. We report on the prevalence of radiological features associated with hip dysplasia in a population of 2081 19-year-old Norwegians. The radiological measurements used to define hip dysplasia were Wiberg’s centre-edge (CE) angle at thresholds of < 20° and < 25°, femoral head extrusion index <  75%, Sharp’s angle > 45°, an acetabular depth to width ratio < 250 and the sourcil shape assessed subjectively. The whole cohort underwent clinical examination of their range of hip movement, body mass index (BMI), and Beighton hypermobility score, and were asked to complete the EuroQol (EQ-5D) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). The prevalence of hip dysplasia in the cohort varied from 1.7% to 20% depending on the radiological marker used. A Wiberg’s CE angle <  20° was seen in 3.3% of the cohort: 4.3% in women and 2.4% in men. We found no association between subjects with multiple radiological signs indicative of dysplasia and BMI, Beighton score, EQ-5D or WOMAC. Although there appears to be a high prevalence of hip dysplasia among 19-year-old Norwegians, this is dependent on the radiological parameters applied.

Cite this article: Bone Joint J 2013;95-B:279–85.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 570 - 575
1 Jul 1997
Boniforti FG Fujii G Angliss RD Benson MKD

We have evaluated the reliability of the measurement of radiological indicators in developmental dysplasia of the hip. Three observers each independently assessed 60 pelvic radiographs from infants aged from 3 to 36 months. Errors from the true value of a single measurement made by a single observer (E1), of the average of two measurements by a single observer (E2), and of the average of two single measurements by two different observers (E3) were established for the acetabular index of Hilgenreiner, for the assessment of superior and lateral femoral displacement and for indicators of pelvic alignment.

The errors for the assessment of the acetabular index were E1 ± 5°, E2 ± 5°, and E3 ± 3.5°. There was a significant correlation between the presence of an acetabular notch on the radiograph and an increased error in measurement (p = 0.01). Yamamuro’s measurement of lateral femoral displacement was more reliable than the Hilgenreiner distance. The errors of indicators of pelvic alignment showed a correlation with the age of the infant; the quotient of pelvic rotation was more reliable after seven months of age (p < 0.0001). The errors of the measurement of the symphysis os-ischium angle tended to increase with age and those of the measurement of the index of pelvic tilt decreased with skeletal maturation (p = 0.002).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 535 - 539
1 Jul 1996
Roolker W Tiel-van Buul MMC Bossuyt PMM Bakker AJ Bos KE Marti RK Broekhuizen AH

We have assessed the value of using a simple apparatus, the Carpal Box, in patients with suspected scaphoid fracture, to produce elongated and magnified radiographs of the carpus. The interobserver agreement between 60 observers of standard scaphoid radiographs and longitudinal and transverse Carpal Box radiographs (X-CB) was compared in 11 patients. Three-phase bone scanning was used as a comparative standard. If at least 75% of the observers agreed and the result was confirmed by three-phase bone scanning, the outcome was termed reliable.

Scaphoid radiographs and the longitudinal X-CB films were reliable in four patients and the transverse X-CB films in six patients. The bone scan suggested a scaphoid fracture in five of the 11 patients.

Agreement in the interpretation of the standard scaphoid radiographs was acceptable in only 36% of patients: in interpretation of transverse Carpal Box radiographs this figure increased to 55%.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 534 - 537
1 Jul 1993
Harada T Ebara S Anwar M Kajiura I Oshita S Hiroshima K Ono K

Some radiological features of the lumbar spine of 84 patients with spastic diplegia were compared with 50 control subjects. The average age of the patients was 20.1 years (3 to 39). Spondylolysis of the fifth lumbar vertebra was found in 21%, four times more frequently than in normal subjects. No patient under nine years of age had spondylolysis and the frequency increased with age. The average angle of lumbar lordosis in spastic patients in the standing position was greater than in normal subjects, and increased with age. The patients had a decreased sacrofemoral angle which caused an increase in Ferguson's angle and explained the increased angle of lumbar lordosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 963 - 964
1 Nov 1996
Krettek C Blauth M Miclau T Rudolf J Könemann B Schandelmaier P

The accuracy of templates used for the preoperative planning of the fixation of intramedullary fractures depends on radiological magnification. To study the accuracy of these templates, we randomly selected 100 femoral and 100 tibial radiographs taken after stabilisation by an intramedullary nail using a standard technique. We then compared the known nail length with the corresponding measurements on the radiographs.

The mean magnification factor for the femur was 9% and for the tibia 7%; these differ considerably from the range of magnification of the manufacturers’ templates (femur, 15% to 17%; tibia 10% to 15%). We conclude that templates are unreliable for the selection of implant length and that this should be done by intraoperative measurements.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 28 - 32
1 Jan 1992
Rubin P Leyvraz P Aubaniac J Argenson J Esteve P de Roguin B

Biological fixation of cementless femoral implants requires primary stability by optimal fit in the proximal femur. The anatomy of the bone must then be known precisely. We analysed in vitro the accuracy of bone measurements of 32 femurs and compared the dimensions obtained from radiographs and CT scans with the true anatomical dimensions. Standard radiographs gave only a rough approximation of femoral geometry (mean difference: 2.4 +/- 1.4 mm) insufficiently accurate to allow selection of the best fitting prosthesis from a range of sizes and altogether inadequate to design a custom-made prosthesis. CT scans give greater accuracy (mean difference: 0.8 +/- 0.7 mm) in our experimental conditions, but in clinical practice additional sources of error exist.