header advert
Results 41 - 60 of 415
Results per page:
Bone & Joint 360
Vol. 2, Issue 1 | Pages 42 - 42
1 Feb 2013
Walker M


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year).

THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 155 - 156
1 Jan 1990
Fairhurst M McDonald I


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 463 - 464
1 Apr 2005
Shimmin AJ Back D

Between April 1999 and April 2004, 3497 Birmingham hips were inserted by 89 surgeons. Fracture of the neck of the femur occurred in 50 patients, an incidence of 1.46%. Complete data were available for 45 patients in whom the incidence was 1.91% for women and 0.98% for men. The relative risk of fracture for women vs men was 1.94961 and this was statistically significant (p < 0.01).

The mean time to fracture was 15.4 weeks. In women the fractures occurred at a mean of 18.5 weeks and were more likely to have been preceded by a pro-dromal phase of pain and limping. In men the mean time to fracture was 13.5 weeks.

Significant varus placement of the femoral component, intra-operative notching of the femoral neck and technical problems were common factors in 85% of cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 922 - 923
1 Nov 1995
Haddad F Williams R

We randomised 50 patients with extracapsular fractures of the femoral neck to receive either a bupivacaine femoral nerve block or systemic analgesia alone. A femoral nerve block was found to be an easy and effective procedure which significantly reduced perioperative analgesic requirements and postoperative morbidity.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 777 - 781
1 Nov 1989
Nilsson L Stromqvist B Thorngren K

We report a series of 640 consecutive cervical hip fractures which were followed prospectively for two years after primary internal fixation with two hook-pins. Secondary arthroplasties were performed as salvage procedures in 75 cases and the early outcome of these was studied retrospectively. The mean time in hospital was 25 days for prosthetic replacement, though 60% of the patients had other medical conditions considered as risk factors. Mortality was 5% after six months and 8% after one year. Dislocation was seen in 11% and additional surgery was required in 4%. There was one case of deep infection and one supracondylar femoral fracture. In some cases there was considerable delay between the primary and secondary operation due to lack of awareness of functional deterioration, but although many patients had poor mobility before the secondary operation this was greatly improved within six weeks of the arthroplasty. We conclude that elective secondary hip arthroplasty for failure of fracture fixation is a safe and successful procedure. Once the decision to perform an arthroplasty is taken, this should be done without delay to avoid deterioration of function.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 537 - 537
1 May 1989
Muirhead A Walsh M


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 384 - 387
1 May 1987
Ions G Stevens J

A prospective study of factors which might help to predict mortality in patients with intracapsular fractures of the femoral neck has been undertaken. A multivariate analysis technique was used to analyse the collected data, and it was found that mental ability was the most significant variable; this factor had the greatest effect on outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 537 - 540
1 Aug 1986
Leung P Lam S

Of 92 children reviewed three to five years after treatment for fractured neck of femur (Lam 1976), we have been able to reassess 41, both clinically and radiographically, at 13 to 23 years after injury. The earlier clinical results had been excellent, despite a high incidence of complications; but the new, later review shows an 83% incidence of radiographic abnormality while 24% of the patients have pain, a limp or leg shortening. We present a recommended policy for management of this rare but potentially serious childhood injury


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 520 - 527
1 Aug 1962
Stevens J Freeman PA Nordin BEC Barnett E

1. Recently described histological and radiographic methods of diagnosing osteoporosis have been applied to patients with transcervical and intertrochanteric fractures of the femur.

2. Both methods indicate a higher incidence of osteoporosis in such patients than in a control series, especially in older women with intertrochanteric fractures.

3. A discrepancy between the results of biopsy and radiographic examination was encountered, the explanation of which is not yet clear.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 406 - 412
1 Mar 2010
Leonardsson O Sernbo I Carlsson Å åkesson K Rogmark C

In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to internal fixation or replacement. Depending on age and level of activity the latter was either a total hip replacement or a hemiarthroplasty. Patients who were confused or bed-ridden were excluded, as were those with rheumatoid arthritis. At ten years there were 99 failures (45.6%) after internal fixation compared with 17 (8.8%) after replacement. The rate of mortality was high at 75% at ten years, and was the same in both groups at all times. Patient-reported pain and function were similar in both groups at five and ten years. Those with successfully healed fractures had more hip pain and reduction of mobility at four months compared with patients with an uncomplicated replacement, and they never attained a better outcome than the latter patients regarding pain or function.

Primary replacement gave reliable long-term results in patients with a displaced fracture of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 448 - 449
1 May 1993
Noordeen M Lavy C Briggs T Roos M

Screw devices used to treat fractures of the femoral neck are usually positioned under image-intensifier control, using anteroposterior and lateral views. The volume projected by these views is over 27% larger than the femoral head; the tips of screws so placed may be outside the femoral head. This can be avoided by placement within the central two-thirds of the head: we have designed a template which can confirm safe placement.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 521 - 522
1 May 1991
Schwarz N


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 530 - 532
1 Nov 1983
Scales J


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 16 - 19
1 Jan 1991
Olerud C Rehnberg L Hellquist E

In a prospective randomised study, the Hansson pin technique for internal fixation of fractures of the femoral neck was compared with the Uppsala screw technique. The series consisted of 115 consecutive patients, 97 women and 18 men, with a mean age of 80 years. There were 56 patients treated with Hansson pins and 59 with Uppsala screws. After one year 22 patients had died, eight in the Hansson pin group and 14 in the Uppsala screw group (p = 0.28). Twenty-four complications had occurred, 18 in the Hansson pin group and six in the Uppsala screw group (p = 0.008). After exclusion of those with complications, the patients in the Hansson pin group had significantly more pain, less mobility, and a smaller proportion were living in their own homes.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown.

Cite this article: Bone Joint J 2014;96-B:299–305.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 148 - 148
1 Jan 2004
KAMATH S


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 380 - 388
1 Apr 2003
Tidermark J Ponzer S Svensson O Söderqvist A Törnkvist H

The treatment algorithms for displaced fractures of the femoral neck need to be improved if we are to reduce the need for secondary surgery. We have studied 102 patients of mean age 80 years, with an acute displaced fracture of the femoral neck. They were randomly placed into two groups, treated either by internal fixation (IF) with two cannulated screws or total hip replacement (THR). None showed severe cognitive dysfunction, all were able to walk independently, and all lived in their own home. They were reviewed at four, 12 and 24 months after surgery. Outcome measurements included hip complications, revision surgery, hip function according to Charnley and the health-related quality of life (HRQoL) according to EuroQol (EQ-5D).

The failure rate after 24 months was higher in the IF group than in the THR group with regard to hip complications (36% and 4%, respectively; p < 0.001), and the number of revision procedures (42% and 4%, p < 0.001). Hip function was significantly better in the THR group at all follow-up reviews regarding pain (p < 0.005), movement (p < 0.05 except at 4 months) and walking (p < 0.05). The reduction in HRQoL (EQ-5D index score) was also significantly lower in the THR group than in the IF group, comparing the pre-fracture situation with that at all follow-up reviews (p < 0.05).

The results of our study strongly suggest that THR provides a better outcome than IF for elderly, relatively healthy, lucid patients with a displaced fracture of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 797 - 800
1 Sep 1990
Clark D Crofts C Saleh M

The rigidity of a sliding compression screw and three cannulated lag screws in the treatment of subcapital fractures was compared in five pairs of female cadaver femora. There were no significant differences between the compressive strength, bone density, cortical thickness or Singh index of the bones in each pair. A subcapital fracture was standardised using a perpendicular saw cut across the femoral neck. A uniaxial 'load test system' with force and length measurement facilities was used to mimic cyclical stressing applied in vivo at a frequency of 0.5 Hz from 0 to 3 times body-weight. There was no significant difference between the fixation afforded by the sliding compression screw and three lag screws. Bone quality was the single most important factor in the stability of the bone implant unit.