The aim of this independent multicentre study was to assess the
mid-term results of mobile bearing unicondylar knee arthroplasty
(UKA) for isolated lateral osteoarthritis of the knee joint. We retrospectively evaluated 363 consecutive, lateral UKAs (346
patients) performed using the Oxford domed lateral prosthesis undertaken
in three high-volume knee arthroplasty centres between 2006 and
2014. Mean age of the patients at surgery was 65 years (36 to 88)
with a mean final follow-up of 37 months (12 to 93)Aims
Patients and Methods
The aims of this study were to examine the rate at which the
positioning of the acetabular component, leg length discrepancy
and femoral offset are outside an acceptable range in total hip
arthroplasties (THAs) which either do or do not involve the use
of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients
before and 50 patients after the integration of an intra-operative
digital imaging system in THA. The demographics of the two groups
were comparable for body mass index, age, laterality and the indication
for surgery. The digital imaging group had more men than the group without.
Surgical data and radiographic parameters, including the inclination
and anteversion of the acetabular component, leg length discrepancy,
and the difference in femoral offset compared with the contralateral
hip were collected and compared, as well as the incidence of altering
the position of a component based on the intra-operative image.Aims
Patients and Methods
We present the ten-year data of a cohort of patients, aged between
18 and 65 years (mean age 52.7 years; 19 to 64), who underwent total
hip arthroplasty. Patients were randomised to be treated with a
cobalt-chrome (CoCr) femoral head with an ultra-high molecular weight
polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE) or
ceramic-on-ceramic (CoC) bearing surface. A total of 102 hips (91 patients) were randomised into the three
groups. At ten years, 97 hips were available for radiological and
functional follow-up. Two hips (two patients) had been revised (one
with deep infection and one for periprosthetic fracture) and three
were lost to follow-up. Radiological analysis was performed using
a validated digital assessment programme to give linear, directional
and volumetric wear of the two polyethylene groups.Aims
Patients and Methods
To determine the incidence and timing of post-operative fevers
following shoulder arthroplasty and the resulting investigations
performed. A retrospective review was conducted of all patients undergoing
shoulder arthroplasty over a nine-year period. The charts of all
patients with a post-operative fever (≥ 38.6°C) were reviewed and
the results of all investigations were analysed.Aims
Patients and Methods
We conducted a study to identify factors that are prognostic
of the outcome of extracorporeal shockwave therapy (ESWT) for calcific
tendinitis of the shoulder. Since 1998, patients with symptomatic calcific tendinitis of
the rotator cuff have been treated with ESWT using an electrohydraulic
mode shockwave device. One year after ESWT, patients were grouped
according to the level of resorption of calcification.Aims
Patients and Methods
The aims of this study were to determine the cumulative ten-year
survivorship of hips treated for acetabular fractures using surgical
hip dislocation and to identify factors predictive of an unfavourable
outcome. We followed up 60 consecutive patients (61 hips; mean age 36.3
years, standard deviation (Aims
Patients and Methods
Several studies have reported the safety and efficacy of subcapital
re-alignment for patients with slipped capital femoral epiphysis
(SCFE) using surgical dislocation of the hip and an extended retinacular
flap. Instability of the hip and dislocation as a consequence of
this surgery has only recently gained attention. We discuss this
problem with some illustrative cases. We explored the literature on the possible pathophysiological
causes and surgical steps associated with the risk of post-operative
instability and articular damage. In addition, we describe supplementary
steps that could be used to avoid these problems.Aims
Materials and Methods
Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical strength of bone treated with BP (oral alendronate), and correlate data with the microarchitecture and density of microcracks in comparison with untreated controls. Trabecular bone from hip fracture patients treated with BP (n = 10) was compared with naïve fractured (n = 14) and non-fractured controls (n = 6). Trabecular cores were synchrotron scanned and micro-CT scanned for microstructural analysis, including quantification of bone volume fraction, microarchitecture and microcracks. The specimens were then mechanically tested in compression.Objectives
Methods
The primary aim of this independent prospective randomised trial
was to compare serum metal ion levels for ceramic-on-metal (CoM)
and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty
(THA). Our one-year results demonstrated elevation in metal ion
levels above baseline with no significant difference between the
CoM and MoM groups. This paper reviews the five-year data. The implants used in each patient differed only in respect to
the type of femoral head (ceramic or metal). At five-year follow-up
of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available
for comparison.Aims
Patients and Methods
The aim of this study was to examine the efficacy and safety
of multiple boluses of intravenous (IV) tranexamic acid (TXA) on
the hidden blood loss (HBL) and inflammatory response following
primary total hip arthroplasty (THA). A total of 150 patients were allocated randomly to receive a
single bolus of 20 mg/kg IV TXA before the incision (group A), a
single bolus followed by a second bolus of 1 g IV-TXA three hours
later (group B) or a single bolus followed by two boluses of 1 g
IV-TXA three and six hours later (group C). All patients were treated
using a standard peri-operative enhanced recovery protocol. Primary
outcomes were HBL and the level of haemoglobin (Hb) as well as the
levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers
of inflammation. Secondary outcomes included the length of stay
in hospital and the incidence of venous thromboembolism (VTE).Aims
Patients and Methods
The primary purpose of this meta-analysis was to determine whether statin usage could reduce the risk of glucocorticoid-related osteonecrosis in animal models. A systematic literature search up to May 2015 was carried out using the PubMed, Ovid, EBM reviews, ISI Web of Science, EBSCO, CBM, CNKI databases with the term and boolean operators: statins and osteonecrosis in all fields. Risk ratio (RR), as the risk estimate of specific outcome, was calculated along with 95% confidence intervals (CI). The methodological quality of individual studies was assessed using a quantitative tool based on the updated Stroke Therapy Academic Industry Roundtable (STAIR) recommendations.Objectives
Methods
Despite the presence of screening programmes, infants continue
to present with late developmental dysplasia of the hip (DDH), the
impact of which is significant. The aim of this study was to assess
infants with late presenting dislocation of the hip despite universal
clinical neonatal and selective ultrasound screening. Between 01 January 1997 to 31 December 2011, a prospective, longitudinal
study was undertaken of a cohort of 64 670 live births. Late presenting
dislocation was defined as presentation after three months of age.
Diagnosis was confirmed by ultrasound and plain radiography. Patient
demographics, referral type, reason for referral, risk factors (breech
presentation/strong family history) and clinical and radiological
findings were recorded.Aims
Patients and Methods
To compare the outcomes for trochanteric fractures treated with
a sliding hip screw (SHS) or a cephalomedullary nail. A total of 400 patients with a trochanteric hip fracture were
randomised to receive a SHS or a cephalomedullary nail (Targon PFT).
All surviving patients were followed up to one year from injury.
Functional outcome was assessed by a research nurse blinded to the
implant used.Aims
Patients and Methods
The purpose of this current multicentre study is to analyse the
presence of alpha-defensin proteins in synovial fluid using the
Synovasure lateral flow device and to determine its diagnostic reliability
and accuracy compared with the prosthetic joint infection (PJI)
criteria produced by the Musculoskeletal Infection Society (MSIS). A cohort of 121 patients comprising 85 total knee arthroplasties
and 36 total hip arthroplasties was prospectively evaluated between
May 2015 and June 2016 in three different orthopaedic centres. The
tests were performed on patients with a chronically painful prosthesis
undergoing a joint aspiration in a diagnostic pathway or during revision
surgery.Aims
Patients and Methods
Our aim was to evaluate the radiographic characteristics of patients
undergoing total hip arthroplasty (THA) for the potential of posterior
bony impingement using CT simulations. Virtual CT data from 112 patients who underwent THA were analysed.
There were 40 men and 72 women. Their mean age was 59.1 years (41
to 76). Associations between radiographic characteristics and posterior
bony impingement and the range of external rotation of the hip were
evaluated. In addition, we investigated the effects of pelvic tilt
and the neck/shaft angle and femoral offset on posterior bony impingement.Aims
Patients and Methods