Advertisement for orthosearch.org.uk
Results 541 - 560 of 7556
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 499 - 503
1 Apr 2009
Kircher J Patzer T Magosch P Lichtenberg S Habermeyer P

We describe the outcome at a mean follow-up of 8.75 years (7.6 to 9.8) of seven patients who had undergone osteochondral autologous transplantation for full-thickness cartilage defects of the shoulder between 1998 and 2000. These patients have been described previously at a mean of 32.6 months when eight were included. One patient has been lost to follow-up. The outcome was assessed by the Constant shoulder score and the Lysholm knee score to assess any donor-site morbidity. Standard radiographs and MR scores were obtained and compared with the pre-operative findings and the results from the previous review.

No patient required any further surgery on the shoulder. The mean Constant score improved significantly until the final follow-up (p = 0.018). The Lysholm score remained excellent throughout. There was a significant progression of osteoarthritic changes from the initial surgery to the first and final follow-up but this did not appear to be related to the size of the defect, the number of cylinders required or the Constant score (p = 0.016). MRI showed that all except one patient had a congruent joint surface at the defect with full bony integration of all osteochondral cylinders.

The results have remained satisfactory over a longer period with very good objective and subjective findings.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications.

We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion.

Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1551 - 1552
1 Nov 2007
Bickerstaff D


Bone & Joint Research
Vol. 3, Issue 11 | Pages 310 - 316
1 Nov 2014
Tomaszewski R Bohosiewicz J Gap A Bursig H Wysocka A

Objectives

The aim of this experimental study on New Zealand’s white rabbits was to investigate the transplantation of autogenous growth plate cells in order to treat the injured growth plate. They were assessed in terms of measurements of radiological tibial varus and histological characteristics.

Methods

An experimental model of plate growth medial partial resection of the tibia in 14 New Zealand white rabbits was created. During this surgical procedure the plate growth cells were collected and cultured. While the second surgery was being performed, the autologous cultured growth plate cells were grafted at the right tibia, whereas the left tibia was used as a control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 684 - 690
1 Jul 1997
Garcia-Elias M


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 383 - 386
1 May 1990
Heeg M Klasen H Visser J

We report a retrospective study of 54 acetabular fractures treated by open reduction and internal fixation, with an average follow-up of 9.6 years (3 to 17). Reduction leaving displacement of less than or equal to 2 mm was achieved in 36 hips (67%); good or excellent functional results were obtained in 33 patients (61%). Early complications requiring re-operation included postoperative loss of reduction in one case and an intra-articular screw in another. Arthrodesis or total hip arthroplasty had been performed in 10 patients (19%) who had late symptomatic degenerative changes. Failure to obtain accurate reduction was the most important factor leading to a poor result, but heterotopic calcification caused poor results in seven patients, five of whom had had an anatomical reduction.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 176 - 181
1 Mar 1985
Dickson R


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 231 - 232
1 May 1981
Ovesen J


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 481 - 483
1 Nov 1979
Fitton J Nevelos A

Operative correction of congenital vertical talus in nine feet in six patients is described. The operation consists of the comprehensive lengthening of the tendons in the foot and full peritalar release without excision of the navicular; it is performed through a dorsal transverse incision.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 395 - 397
1 Nov 1976
Seddon H


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 411 - 411
1 Nov 1975
Trickey EL


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 267 - 268
1 Aug 1975
Malpas JS


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 264 - 264
1 May 1975
Ratliff AHC


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 213 - 213
1 Feb 1974
Duthie RB


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 3 | Pages 436 - 437
1 Aug 1957
Capener N


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 367 - 368
1 Aug 1955
Scott JC


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 3 - 5
1 Feb 1953
Shanks W


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 4 | Pages 517 - 518
1 Nov 1953
Pennybacker JB


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 2 | Pages 335 - 336
1 May 1952
Gissane W


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated.

The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221).

The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°).

At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.