Since September 1964, neonates born in New Plymouth have undergone clinical examination for instability of the hip in a structured clinical screening programme. Of the 41 563 babies born during this period, 1639 were diagnosed as having unstable hips and 663 (1.6%) with persisting instability were splinted, five of which failed. Also, three unsplinted hips progressed to congenital dislocation, and there were four late-presenting (walking) cases, giving an overall failure rate of 0.29 per 1000 live births, with an incidence of late-walking congenital dislocation of the hip of 0.1 per 1000 live births. This study confirms that clinical screening for neonatal instability of the hip by experienced orthopaedic examiners significantly reduces the incidence of late-presenting (walking) congenital dislocation of the hip.
The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of >
5 mm and an angulation of >
30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily. Re-displacement of fragments or migration of Kirschner wires was seen in five cases. Necrosis of the humeral head developed in four patients. In three patients a secondary arthroplasty had to be performed, in two because of re-displacement and in one for necrosis of the head. There was one case of deep infection which required a further operation and one of delayed healing. The mean Constant score of the patients with a three-part fracture was 61.2 points (35 to 87) which was 84.9% of the score for the non-injured arm. In four-part fractures it was 49.5 points (18 to 87) or 68.5% of the score for the non-injured arm. The Humerusblock technique can provide a comfortable and mobile shoulder in elderly patients and is a satisfactory alternative to replacement and traditional techniques of internal fixation.
We undertook a retrospective review of 33 patients who underwent total femoral endoprosthetic replacement as limb salvage following excision of a malignant bone tumour. In 22 patients this was performed as a primary procedure following total femoral resection for malignant disease. Revision to a total femoral replacement was required in 11 patients following failed segmental endoprosthetic or allograft reconstruction. There were 33 patients with primary malignant tumours, and three had metastatic lesions. The mean age of the patients was 31 years (5 to 68). The mean follow-up was 4.2 years (9 months to 16.4 years). At five years the survival of the implants was 100%, with removal as the endpoint and 56% where the endpoint was another surgical intervention. At five years the patient survival was 32%. Complications included dislocation of the hip in six patients (18%), local recurrence in three (9%), peri-prosthetic fracture in two and infection in one. One patient subsequently developed pulmonary metastases. There were no cases of aseptic loosening or amputation. Four patients required a change of bushings. The mean Musculoskeletal Tumour Society functional outcome score was 67%, the mean Harris Hip Score was 70, and the mean Oxford Knee Score was 34. Total femoral endoprosthetic replacement can provide good functional outcome without compromising patient survival, and in selected cases provides an effective alternative to amputation.
Heterotopic ossification occurring after the use of commercially available bone morphogenetic proteins has not been widely reported. We describe four cases of heterotopic ossification in patients treated with either recombinant bone morphogenetic protein 2 or recombinant bone morphogenetic protein 7. We found that while some patients were asymptomatic, heterotopic ossification which had occurred around a joint often required operative excision with good results.
A single antegrade Rush nail was used to treat 37 fractures of the distal humerus extending to the olecranon fossa and up to 6.5 cm proximal to it. In order to stabilise the fracture, the bent tip of the Rush nail was directed into the lateral epicondylar ridge. This gave immediate stability. All the fractures united without residual stiffness of the shoulder or elbow.
We reviewed the results at nine to 13 years of 125 total hip replacements in 113 patients using the monoblock uncemented Morscher press-fit acetabular component. The mean age at the time of operation was 56.9 years (36 to 74). The mean clinical follow-up was 11 years (9.7 to 13.5) and the mean radiological follow-up was 9.4 years (7.7 to 13.1). Three hips were revised, one immediately for instability, one for excessive wear and one for deep infection. No revisions were required for aseptic loosening. A total of eight hips (7.0%) had osteolytic lesions greater than 1 cm, in four around the acetabular component (3.5%). One required bone grafting behind a well-fixed implant. The mean wear rate was 0.11 mm/year (0.06 to 0.78) and was significantly higher in components with a steeper abduction angle. Kaplan-Meier survival curves at 13 years showed survival of 96.8% (95% confidence interval 90.2 to 99.0) for revision for any cause and of 95.7% (95% confidence interval 88.6 to 98.4) for any acetabular re-operation.
The management of closed fractures of the humerus with an associated nerve palsy remains controversial. With very little written about this injury in children, we present the case of a three-year-old child with a closed humeral shaft fracture in whom surgical exploration and reconstruction of the radial nerve with a sural nerve graft was performed three months after injury. The child regained full function. To the best of our knowledge, this is the first such case to be reported in the English literature.
We describe a near-fatal event, probably due to air embolism, following an air arthrogram for developmental hip dysplasia in a baby aged four months. The sequence of events and the subsequent treatment are described. There is little information about this complication in the literature. The presumed mechanism and alternative methods for confirmation of placement of the needle are discussed. We no longer use air arthrography in children.
We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips). The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris.
We have studied the natural history of a first episode of dislocation after primary total hip replacement (THR) to clarify the incidence of recurrent dislocation, the need for subsequent revision and the quality of life of these patients. Over a six-year period, 99 patients (101 hips) presented with a first dislocation of a primary THR. A total of 61 hips (60.4%) had dislocated more than once. After a minimum follow-up of one year, seven patients had died. Of the remaining 94 hips (92 patients), 47 underwent a revision for instability and one awaits operation (51% in total). Of these, seven re-dislocated and four needed further surgery. The quality of life of the patients was studied using the Oxford Hip Score and the EuroQol-5 Dimension (EQ-5D) questionnaire. A control group of patients who had not dislocated was also studied. At a mean follow-up of 4.5 years (1 to 20), the mean Oxford Hip Score was 26.7 (15 to 47) after one episode of dislocation, 27.2 (12 to 45) after recurrent dislocation, 34.5 (12 to 54) after successful revision surgery, 42 (29 to 55) after failed revision surgery and 17.4 (12 to 32) in the control group. The EuroQol-5 dimension questionnaire revealed more health problems in patients undergoing revision surgery.
We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study. Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality. We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip.
We reviewed 44 consecutive revision hip replacements in 38 patients performed using the cement-in-cement technique. All were performed for acetabular loosening in the presence of a well-fixed femoral component. The mean follow-up was 5.1 years (2 to 10.1). Radiological analysis at final follow-up indicated no loosening of the femoral component, except for one case with a continuous radiolucent line in all zones and peri-prosthetic fracture which required further revision. Peri-operative complications included nine proximal femoral fractures (20.4%) and perforation of the proximal femur in one hip. In five hips wiring or fixation with a braided suture was undertaken but no additional augmentation was required. There was an improvement in the mean Japanese Orthopaedic Association score from 55.5 (28 to 81) pre-operatively to 77.8 (40 to 95) at final follow-up (p <
0.001). Revision using a cement-in-cement technique allows increased exposure for acetabular revision and is effective in the medium term. Further follow-up is required to assess the long-term results in the light of in vitro studies which have questioned the quality of the cement-in-cement bond.
The Salter innominate osteotomy has been used successfully for many years in the treatment of developmental dysplasia of the hip. One of its main drawbacks is the need for internal fixation with pins and their subsequent removal. We describe a modification of this osteotomy that does not require pin fixation and secondary removal. We retrospectively reviewed 114 hips in 94 patients who had been operated on by a single surgeon. An oblique rather than the original horizontal osteotomy was used without internal fixation. There were 80 female and 14 male patients. The mean age at operation was 25 months (18 to 84) and the mean follow-up was 30 months (12 to 88). Most patients required additional open reduction and capsuloplasty. The mean pre-operative acetabular index was 37.9° (24° to 54°), which decreased to 19.9° (7° to 29°) in the immediate post-operative period, and improved to 14.6° (5° to 25°) at the final follow-up (student’s We believe that by changing the direction of the osteotomy line, it is possible to avoid pin fixation. The radiological outcomes are comparable to those of the original technique, but longer follow-up will be necessary.
We report the long-term outcome of a modified second-generation cementing technique for fixation of the acetabular component of total hip replacement. An earlier report has shown the superiority of this technique assessed by improved survival compared with first-generation cementing. The acetabular preparation involved reaming only to the subchondral plate, followed by impaction of the bone in the anchorage holes. Between 1978 and 1993, 287 total hip replacements were undertaken in 244 patients with a mean age of 65.3 years (21 to 90) using a hemispherical Weber acetabular component with this modified technique for cementing and a cemented femoral component. The survival with acetabular revision for aseptic loosening as the endpoint was 99.1% (95% confidence interval 97.9 to 100 after ten years and 85.5% (95% confidence interval 74.7 to 96.2) at 20 years. Apart from contributing to a long-lasting fixation of the component, this technique also preserved bone, facilitating revision surgery when necessary.
Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96). A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device
We treated 98 patients with peri-acetabular tumours by resection and reconstruction with a custom-made pelvic endoprosthesis. The overall survival of the patients was 67% at five years, 54% at ten years and 51% at 30 years. One or more complications occurred in 58.1% of patients (54), of which infection was the most common, affecting 30% (28 patients). The rate of local recurrence was 31% (29 patients) after a mean follow-up of 71 months (11 to 147). Dislocation occurred in 20% of patients (19). Before 1996 the rate was 40.5% (17 patients) but this was reduced to 3.9% (two patients) with the introduction of a larger femoral head. There were six cases of palsy of the femoral nerve with recovery in only two. Revision or excision arthroplasty was performed in 23.7% of patients (22), principally for uncontrolled infection or aseptic loosening. Higher rates of death, infection and revision occurred in men. This method of treatment is still associated with high morbidity. Patients should be carefully selected and informed of this pre-operatively.
We have managed 27 patients (16 women and 11 men) with a mean age of 68.4 years (50 to 84), with failed total hip replacement and severe proximal femoral bone loss by revision using a distal fix/proximal wrap prosthesis. The mean follow-up was for 55.3 months (25 to 126). The mean number of previous operations was 2.2 (1 to 4). The mean Oxford hip score decreased from 46.2 (38 to 60) to 28.5 (17 to 42) (paired t-test, p <
0.001) and the mean Harris Hip score increased from 30.4 (3 to 57.7) to 71.7 (44 to 99.7) (paired t-test, p <
0.001). There were two dislocations, and in three patients we failed to eradicate previous infection. None required revision of the femoral stem. This technique allows instant distal fixation while promoting biological integration and restoration of bone stock. In the short term, the functional outcome is encouraging and the complication rates acceptable in this difficult group of patients.
Ultra-high-molecular-weight polyethylene sterilised in the absence of air and highly cross-linked polyethylene have been used to avoid osteolysis and loosening in total hip replacement. Our prospective randomised study has assessed the results using two different polyethylenes associated with the same prosthetic design. We assessed 45 Allofit acetabular components with a Sulene-polyethylene liner of conventional polyethylene gamma sterilised with nitrogen and 45 Allofit acetabular components with a Durasul-polyethylene liner sterilised in ethylene oxide, both matched with an Alloclassic stem with a 28 mm modular femoral head. The prostheses were implanted between May 1999 and December 2001. The mean follow-up was for 66.3 months (60 to 92). The linear penetration of the femoral head was estimated at 6 weeks, at 6 and 12 months and annually thereafter from standardised digitised radiographs using image-analysis software. There was no loosening of any prosthetic component. There were no radiolucent lines or osteolysis. The mean rate of penetration calculated from regression analysis during the first five years was 38 μm/year (
The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p <
0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.