Advertisement for orthosearch.org.uk
Results 521 - 540 of 615
Results per page:
Bone & Joint 360
Vol. 2, Issue 6 | Pages 31 - 33
1 Dec 2013

The December 2013 Children’s orthopaedics Roundup360 looks at: Long term-changes in hip morphology following osteotomy; Arthrogrypotic wrist contractures are surgically amenable; Paediatric femoral lengthening over a nail; Current management of paediatric supracondylar fractures; MRI perfusion index predictive of Perthes’ progression; Abduction bracing effective in residual acetabular deformity; Hurler syndrome in the spotlight; and the Pavlik works for femoral fractures too!


Bone & Joint 360
Vol. 2, Issue 5 | Pages 16 - 18
1 Oct 2013

The October 2013 Hip & Pelvis Roundup360 looks at: Young and impinging; Clothes, weather and femoral heads?; Go long, go cemented; Surgical repair of the abductors?; Aspirin for DVT prophylaxis?; Ceramic-on-polyethylene: a low-wear solution?; ALVAL and ASR™: the story continues….; Salvaging Legg-Calve-Perthes’ disease


Bone & Joint 360
Vol. 2, Issue 5 | Pages 2 - 7
1 Oct 2013
Penn-Barwell JG Rowlands TK

Blast and ballistic weapons used on the battlefield cause devastating injuries rarely seen outside armed conflict. These extremely high-energy injuries predominantly affect the limbs and are usually heavily contaminated with soil, foliage, clothing and even tissue from other casualties. Once life-threatening haemorrhage has been addressed, the military surgeon’s priority is to control infection.

Combining historical knowledge from previous conflicts with more recent experience has resulted in a systematic approach to these injuries. Urgent debridement of necrotic and severely contaminated tissue, irrigation and local and systemic antibiotics are the basis of management. These principles have resulted in successful healing of previously unsurvivable wounds. Healthy tissue must be retained for future reconstruction, vulnerable but viable tissue protected to allow survival and avascular tissue removed with all contamination.

While recent technological and scientific advances have offered some advantages, they must be judged in the context of a hard-won historical knowledge of these wounds. This approach is applicable to comparable civilian injury patterns. One of the few potential benefits of war is the associated improvement in our understanding of treating the severely injured; for this positive effect to be realised these experiences must be shared.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 639 - 643
1 May 2011
Burghardt RD Herzenberg JE Specht SC Paley D

Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device.

The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.


Bone & Joint 360
Vol. 2, Issue 4 | Pages 27 - 29
1 Aug 2013

The August 2013 Children’s orthopaedics Roundup360 looks at: a multilevel approach to equinus gait; whether screening leads to needless intervention; salvage of subcapital slipped epiphysis; growing prostheses for children’s oncology; flexible nailing revisited; ultrasound and the pink pulseless hand; and slipping forearm fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 68 - 75
1 Jan 2005
Miedel R Ponzer S Törnkvist H Söderqvist A Tidermark J

We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D).

The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p < 0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5Dindexscore) was significant in both groups compared with that before the fracture (p < 0.005).

Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures.

The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1280 - 1284
1 Sep 2013
Yamaguchi T Matsumine A Niimi R Nakamura T Matsubara T Asanuma K Hasegawa M Sudo A

The aim of this study was to define the incidence of venous thromboembolism (VTE) and risk factors for the development of deep-vein thrombosis (DVT) after the resection of a musculoskeletal tumour. A total of 94 patients who underwent resection of a musculoskeletal tumour between January 2003 and December 2005 were prospectively studied. There were 42 men and 52 women with a mean age of 54.4 years (18 to 86). All patients wore intermittent pneumatic compression devices and graduated compression stockings. Ultrasound examination of the lower limbs was conducted to screen for DVT between the fifth and ninth post-operative days.

DVT was detected in 21 patients (22%). Of these, two were symptomatic (2%). One patient (1%) had a fatal pulmonary embolism. Patients aged ≥ 70 years had an increased risk of DVT (p = 0.004).

The overall incidence of DVT (both symptomatic and asymptomatic) after resection of a musculoskeletal tumour with mechanical prophylaxis was high. It seems that both mechanical and anticoagulant prophylaxis is needed to prevent VTE in patients who have undergone the resection of a musculoskeletal tumour.

Cite this article: Bone Joint J 2013;95-B:1280–4.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 145 - 145
1 Feb 2013
Villar RN


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1556 - 1559
1 Nov 2005
John VZ Alagappan M Devadoss S Devadoss A

Despite advances in reconstructive surgery, salvage of mangled extremities still requires long periods of treatment with many operations that can be taxing both to the surgeon and the patient. Attempts at reconstruction of severely shattered limbs necessitate counselling with regard to the protracted course of treatment and associated morbidity as well as problems which may require abandoning of the procedure and secondary amputation. We report the successful salvage of a severely comminuted and open fracture of the tibia in a 32-year-old man.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 1001 - 1006
1 Jul 2013
Esteban J Alvarez-Alvarez B Blanco A Fernández-Roblas R Gadea I Garcia-Cañete J Sandoval E Valdazo M

We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.

Cite this article: Bone Joint J 2013;95-B:1001–6.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 42 - 43
1 Feb 2013
Moran CG


Bone & Joint Research
Vol. 2, Issue 5 | Pages 79 - 83
1 May 2013
Goffin JM Pankaj P Simpson AHRW Seil R Gerich TG

Objectives

Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA).

Methods

We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients.


Bone & Joint 360
Vol. 1, Issue 6 | Pages 1 - 1
1 Dec 2012
Ollivere BJ


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 141 - 148
1 Feb 2006
Sarmiento A Latta L


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 875 - 879
1 Jun 2010
Puri A Gulia A Agarwal MG Reddy K

Between June 2005 and March 2008, 14 patients with a Campanacci grade-3 giant-cell tumour of the distal radius were treated by en bloc resection and reconstruction by ulnar translocation with arthrodesis of the wrist. The mean length of radius resected was 7.9 cm (5.5 to 15). All the patients were followed to bony union and 12 were available at a mean follow-up of 26 months (10 to 49).

The mean time to union was four months (3 to 7) at the ulnocarpal junction and five months (3 to 8) at the ulnoradial junction. All except one patient had an excellent range of pronation and supination. The remaining patient developed a radio-ulnar synostosis. The mean Musculoskeletal Tumor Society score was 26 (87%, range 20 to 28). Three patients had a soft-tissue recurrence, but with no bony involvement. They underwent a further excision and are currently well and free from disease.

Ulnar translocation provides a local vascularised bone graft to reconstruct the defect left after excision of the distal radius for giant cell tumour. It avoids the need for a microvascular procedure while retaining rotation of the forearm and good function of the hand.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 22 - 25
1 Nov 2012
Haidukewych GJ

Many tumors metastasise to bone, therefore, pathologic fracture and impending pathologic fractures are common reasons for orthopedic consultation. Having effective treatment strategies is important to avoid complications, and relieve pain and preserve function. Thorough pre-operative evaluation is recommended for medical optimization and to ensure that the lesion is in fact a metastasis and not a primary bone malignancy. For impending fractures, various scoring systems have been proposed to determine the risk of fracture, and therefore the need for prophylactic stabilisation. Lower score lesions can often be treated with radiation, while more problematic lesions may require internal fixation. Intramedullary fixation is generally preferred due to favorable biomechanics. Arthroplasty may be required for lesions with massive bony destruction where internal fixation attempts are likely to fail. Radiation may also be useful postoperatively to minimise construct failure due to tumor progression.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 843 - 844
1 Jun 2009
Clarke NMP


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 116 - 118
1 Jan 2006
Fabeck L Ghafil D Gerroudj M Baillon R Delincé P

We describe a 13-year-old boy with atrophic tibial pseudarthrosis associated with neurofibromatosis who had undergone nine unsuccessful operations. Eventually, union was obtained by the use of bone morphogenetic protein 7 in conjunction with intramedullary stabilisation and autologous bone graft.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 101 - 105
1 Jan 2013
Penn-Barwell JG Bennett PM Fries CA Kendrew JM Midwinter MJ Rickard RF

The aim of this study was to report the pattern of severe open diaphyseal tibial fractures sustained by military personnel, and their orthopaedic–plastic surgical management.The United Kingdom Military Trauma Registry was searched for all such fractures sustained between 2006 and 2010. Data were gathered on demographics, injury, management and preliminary outcome, with 49 patients with 57 severe open tibial fractures identified for in-depth study. The median total number of orthopaedic and plastic surgical procedures per limb was three (2 to 8). Follow-up for 12 months was complete in 52 tibiae (91%), and half the fractures (n = 26) either had united or in the opinion of the treating surgeon were progressing towards union. The relationship between healing without further intervention was examined for multiple variables. Neither the New Injury Severity Score, the method of internal fixation, the requirement for vascularised soft-tissue cover nor the degree of bone loss was associated with poor bony healing. Infection occurred in 12 of 52 tibiae (23%) and was associated with poor bony healing (p = 0.008). This series characterises the complex orthopaedic–plastic surgical management of severe open tibial fractures sustained in combat and defines the importance of aggressive prevention of infection.

Cite this article: Bone Joint J 2013;95-B:101–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty.