header advert
Results 521 - 540 of 4128
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 784 - 786
1 Nov 1988
Mitsou A Vallianatos P Piskopakis N Nicolaou P

In 30 rabbits, the medial meniscus was used to replace the anterior or posterior cruciate ligament. The changes that took place were followed in histological sections, obtained both from the area of insertion into bone and from the intra-articular part of the graft. There was a gradual differentiation to chondroid tissue, with subsequent calcific deposition and no appearance of normal ligamentous tissue. The strength of the graft after 52 weeks was only one-quarter of that of the normal ligament. Our results do not justify the use of the meniscus to replace a torn cruciate ligament.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 358 - 363
1 May 1988
Shelley P Wroblewski B

An experimental evaluation was made of the efficacy of an unflanged cup, an ogee-flanged cup and the Exeter pressuriser in the pressurisation of acetabular cement. Only a very modest injection pressure could be generated through an unflanged socket and even this was readily lost as the socket "bottomed out". The ogee-flanged socket gave a consistently high injection pressure which could be maintained throughout the process of polymerisation. The Exeter pressuriser gave marginally better results. Of the two cements tested, Palacos with gentamicin showed better intrusion than CMW Type 1 cement, but it also allowed greater extrusion once pressure was released. The importance of maintaining a continuous pressure on the cement throughout polymerisation is emphasised.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 312 - 316
1 Mar 1987
Thomas N Turner I Jones C

Four types of prosthetic replacement for the anterior cruciate ligament (carbon fibre, carbon fibre and Dacron composite, Dacron alone and bovine xenograft) were assessed at three, six and 12 months after implantation in the knees of New Zealand white rabbits. The synovium and both intra-articular and intra-osseous portions of the ligaments were examined macroscopically, by light microscopy and by scanning electron microscopy. All the knees showed mild synovitis, and there was no significant growth into the intra-articular part of any ligament. Carbon fibre and xenograft did not appear to be suitable materials in this animal model. The composite ligament showed short-term ingrowth of fibrous tissue only into the periphery of the sheath in its intra-osseous portion, whereas the Dacron ligament showed progressive fibrous tissue ingrowth with some bony incorporation of its outer fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 116 - 120
1 Jan 1987
Tsuge K Murakami T Yasunaga Y Kanaujia R

We report the use of a new approach for elbow arthroplasty in 58 cases over a 20-year period. A wide exposure, obtained by elevating the triceps attachment and dividing the radial collateral ligament, allows the excision of diseased tissue, articular irregularities and osteophytes. Normal anatomy is restored and active mobilisation can be started 10 days after operation. Good or fair results, with over 70 degrees of joint movement, were achieved in 88% of cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 566 - 569
1 Aug 1986
Roper B Tuke M O'Riordan S Bulstrode C

Sixty unconstrained elbow replacements of a new design have been followed prospectively for three to nine years. Review showed that 50% had excellent relief of pain and return of function, 27% had had major complications requiring removal or revision of the prosthesis and 23% had minor complications which marred the result. Further research in this field seems worthwhile.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 3 | Pages 362 - 365
1 Aug 1979
Pho R

An operation is described in which a microvascular technique was used to transfer a living fibula, with its vascular pedicle intact, to replace the lower end of the radius after massive resection for giant-cell tumour. Angiography carried out six weeks later showed that the grafted bone was viable. Six months after operation the transplanted fibula showed no osteoporosis or bone resorption and bony union at the junction of host and graft.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1271 - 1276
1 Sep 2012
Luyckx T Peeters T Vandenneucker H Victor J Bellemans J

Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an ‘adapted’ measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan.

Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (sd 2.5) in the gap-balancing group and 1.7° (sd 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our ‘adapted’ measured resection technique was much lower than reported in the literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 310 - 315
1 Mar 2009
Olsen M Davis ET Waddell JP Schemitsch EH

We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip.

The mean neck-shaft angle determined before operation was 132.7° (118° to 160°). The mean planned stem-shaft angle was a relative valgus alignment of 9.7° (sd 2.6). The stem-shaft angle after operation differed from that planned by a mean of 2.8° (sd 2.0) and in 86% of cases the final angle measured within ± 5° of that planned. We had no instances of notching of the neck or varus alignment of the implant in our series. A learning curve was observed in the time taken for navigation, but not for accurate placement of the implant.

Navigation in hip resurfacing may afford the surgeon a reliable and accurate method of placement of the femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 459 - 465
1 Apr 2012
Nikolaou VS Edwards MR Bogoch E Schemitsch EH Waddell JP

The ideal bearing surface for young patients undergoing total hip replacement (THR) remains controversial. We report the five-year results of a randomised controlled trial comparing the clinical and radiological outcomes of 102 THRs in 91 patients who were <  65 years of age. These patients were randomised to receive a cobalt–chrome on ultra-high-molecular-weight polyethylene, cobalt–chrome on highly cross-linked polyethylene, or a ceramic-on-ceramic bearing. In all, 97 hip replacements in 87 patients were available for review at five years. Two hips had been revised, one for infection and one for peri-prosthetic fracture.

At the final follow-up there were no significant differences between the groups for the mean Western Ontario and McMaster Universities osteoarthritis index (pain, p = 0.543; function, p = 0.10; stiffness, p = 0.99), Short Form-12 (physical component, p = 0.878; mental component, p = 0.818) or Harris hip scores (p = 0.22). Radiological outcomes revealed no significant wear in the ceramic group.

Comparison of standard and highly cross-linked polyethylene, however, revealed an almost threefold difference in the mean annual linear wear rates (0.151 mm/year versus 0.059 mm/year, respectively) (p < 0.001).


Bone & Joint Open
Vol. 3, Issue 12 | Pages 977 - 990
23 Dec 2022
Latijnhouwers D Pedersen A Kristiansen E Cannegieter S Schreurs BW van den Hout W Nelissen R Gademan M

Aims. This study aimed to investigate the estimated change in primary and revision arthroplasty rate in the Netherlands and Denmark for hips, knees, and shoulders during the COVID-19 pandemic in 2020 (COVID-period). Additional points of focus included the comparison of patient characteristics and hospital type (2019 vs COVID-period), and the estimated loss of quality-adjusted life years (QALYs) and impact on waiting lists. Methods. All hip, knee, and shoulder arthroplasties (2014 to 2020) from the Dutch Arthroplasty Register, and hip and knee arthroplasties from the Danish Hip and Knee Arthroplasty Registries, were included. The expected number of arthroplasties per month in 2020 was estimated using Poisson regression, taking into account changes in age and sex distribution of the general Dutch/Danish population over time, calculating observed/expected (O/E) ratios. Country-specific proportions of patient characteristics and hospital type were calculated per indication category (osteoarthritis/other elective/acute). Waiting list outcomes including QALYs were estimated by modelling virtual waiting lists including 0%, 5% and 10% extra capacity. Results. During COVID-period, fewer arthroplasties were performed than expected (Netherlands: 20%; Denmark: 5%), with the lowest O/E in April. In the Netherlands, more acute indications were prioritized, resulting in more American Society of Anesthesiologists grade III to IV patients receiving surgery. In both countries, no other patient prioritization was present. Relatively more arthroplasties were performed in private hospitals. There were no clinically relevant differences in revision arthroplasties between pre-COVID and COVID-period. Estimated total health loss depending on extra capacity ranged from: 19,800 to 29,400 QALYs (Netherlands): 1,700 to 2,400 QALYs (Denmark). With no extra capacity it will take > 30 years to deplete the waiting lists. Conclusion. The COVID-19 pandemic had an enormous negative effect on arthroplasty rates, but more in the Netherlands than Denmark. In the Netherlands, hip and shoulder patients with acute indications were prioritized. Private hospitals filled in part of the capacity gap. QALY loss due to postponed arthroplasty surgeries is considerable. Cite this article: Bone Jt Open 2022;3(12):977–990


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 145 - 148
1 Feb 2008
Stockley I Mockford BJ Hoad-Reddick A Norman P

We present a series of 114 patients with microbiologically-proven chronically-infected total hip replacement, treated between 1991 and 2004 by a two-stage exchange procedure with antibiotic-loaded cement, but without the use of a prolonged course of antibiotic therapy. The mean follow-up for all patients was 74 months (2 to 175) with all surviving patients having a minimum follow-up of two years. Infection was successfully eradicated in 100 patients (87.7%), a rate which is similar to that reported by others, but where prolonged adjuvant antibiotic therapy has been used. Using the technique described, a prolonged course of systemic antibiotics does not appear to be essential and the high cost of the administration of antibiotics can be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 50 - 54
1 Jan 2001
Oostenbroek HJ van Roermund PM

We treated 15 patients by arthrodesis of the knee after removal of an infected total knee arthroplasty, using an Ilizarov ring fixator. Eight had a failed arthrodesis by another technique. The mean age of the patients was 75 years, the mean duration of retention of the frame was 28 weeks, the mean treatment time 51 weeks, and the mean follow-up 52 months. All but one knee fused at the first attempt, a rate of union of 93%. The incidence of complications related to treatment was 80%. The length of treatment and rates of complication were attributed to advanced age and the adverse local clinical factors in these patients. The Ilizarov method is a promising technique for achieving arthrodesis under these circumstances.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 521 - 522
1 Jul 1997
Sandhu SS Lowry JC Morton ME Reuben SF


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 550 - 555
1 Aug 1988
Linder L Carlsson A Marsal L Bjursten L Branemark P

In an experimental clinical study, 25 implants of pure titanium were inserted into the proximal tibia of 11 volunteer patients, four with rheumatoid arthritis and seven with osteoarthritis. The implants were removed from five weeks to 24 months later and detailed histological analysis was performed. The implants generally healed with direct bone-metal contact, showing so-called osseointegration. Only one of the 21 implants which had been in place for over five months did not show osseointegration, probably because of inadequate primary contact with bone. The presence of rheumatoid disease did not prevent osseointegration, but accompanying osteoporosis seemed to be a risk factor.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 367 - 372
1 May 1988
Samuelson K Freeman M Levack B Rassmussen G Revell P

Thirty-seven patients with extensive acetabular defects due to loose implants had revisions with uncemented components, the acetabulum being augmented with homograft bone. In six of these, a histological study of graft incorporation was made. At a mean follow-up of 1.5 years 34 patients were free of pain and 35 could walk for 30 minutes or longer. No graft had obviously sequestrated. Two components had radiological evidence of migration but remain asymptomatic. We conclude that cementless revision surgery with homograft supplementation of the acetabulum is clinically successful in the short-term. The long-term outcome is unknown.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 308 - 309
1 May 1983
Rushton N Dandy D Naylor C

Thirty-nine patients underwent reconstruction of the anterior cruciate ligament with carbon-fibre and a MacIntosh repair; all had a negative pivot shift test after operation. Some patients had persistent pain, mild effusion and synovial thickening; in 10 of these patients the symptoms warranted arthroscopic examination and biopsy at a mean of 16.9 months after the repair. Arthroscopy revealed that the carbon-fibre had not induced the formation of a "new ligament" and that the repair was merely covered by a thin, fibrous sheath. Histological investigations confirmed this finding, with only a suggestion of a fibroblastic response to carbon-fibre found in two patients. Particles of carbon-fibre were found scattered through the knees. Synovitis and breakdown of the skin over subcutaneous carbon-fibre complicated treatment. Failure of the carbon-fibre to bond to bone was detected radiographically.


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 61 - 76
1 Feb 1972
Charnley J

1. The results have been reported of total hip replacement by a low-friction technique using high-density polyethylene for the acetabular component in 379 primary interventions, performed between November 1962 and December 1965 and followed for between four and seven years.

2. Apart from failures due to infection, the rate of which in the era under review was 3·8 per cent, late failures from mechanical causes were unusual after total hip replacement by this technique. When the socket was cemented in position, which is now routine, the late mechanical failure from all causes was only 1·3 per cent in 210 cases.

3. As regards the quality of the results and their maintenance over the years, the results were so good (Table X) that it was unnecessary to distinguish an intermediate class of "improvement" between success and failure.

4. As regards relief of pain and ability to walk, the average final rating, on a scale numbered 1 to 6, was 5·9 for both, indicating 90 per cent of patients in Grade 6 (excellent) and only 10 per cent in Grade 5 (good).

5. The average recovery of movement was not as spectacular and was influenced considerably by the pre-operative range, but in all cases that range was improved on. Even starting with the stiffest of hips about one patient in four regained a right angle of flexion movement. There was no tendency to lose movement with the passage of time.

6. As regards late infection (2·2 per cent out of a total of 3·8 per cent), the various findings tend to exonerate cement as a cause.

7. The mechanical details of the technique became stabilised in the period 1959 to 1962 in the Teflon era, and with the exception of improved methods of reattachment of the greater trochanter, they are identical with our current practice in 1971.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode.

Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening.

The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 535 - 541
1 Apr 2008
Pendegrass CJ Sundar S Oddy MJ Cannon SR Briggs T Blunn GW

We used an in vivo model to assess the use of an autogenous cancellous bone block and marrow graft for augmenting tendon reattachment to metallic implants. We hypothesised that augmentation of the tendon-implant interface with a bone block would enable retention of the graft on the implant surface, enhance biological integration, and result in more consistent functional outcomes compared with previously reported morcellised graft augmentation techniques.

A significant improvement in functional weight-bearing was observed between six and 12 weeks. The significant increase in ground reaction force through the operated limb between six and 12 weeks was greater than that reported previously with morcellised graft augmented reconstructions. Histological appearance and collagen fibre orientation with bone block augmentation more closely resembled that of an intact enthesis compared with the morcellised grafting technique. Bone block augmentation of tendon-implant interfaces results in more reliable functional and histological outcomes, with a return to pre-operative levels of weight-bearing by 24 weeks.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 746 - 751
1 Nov 1987
Saito M Saito S Ohzono K Ono K

We have followed up a series of total hip arthroplasties performed for secondary osteoarthritis and analysed the results in relation to the osteoblastic response to the disease. This was assessed pre-operatively from the radiographic appearance, according to Bombelli's criteria (1983). Of 63 hips in 55 patients followed up for five to 13 years, 17 were hypertrophic, 24 normotrophic and 22 atrophic in type. The atrophic-type hips showed a high incidence of acetabular loosening, leading to unsatisfactory clinical results in 32%. By contrast, the hypertrophic-type hips had a low incidence of acetabular loosening, while the normotrophic type showed intermediate results. It was concluded that the osteoblastic response to osteoarthritis is closely related to acetabular loosening and to late clinical failure.