Advertisement for orthosearch.org.uk
Results 501 - 520 of 1179
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1462 - 1467
1 Nov 2008
Patel RV Apostle K Leith JM Regan WD

We have investigated the outcome of arthroscopic revision surgery for recurrent instability of the shoulder after failed primary anterior stabilisation. We identified 40 patients with failed primary open or arthroscopic anterior stabilisation of the shoulder who had been treated by revision arthroscopic capsulolabral reconstruction and followed up for a mean of 36 months (12 to 87). There were 34 men and six women with a mean age of 33.1 years (15 to 48). Details of the patients, the technique of the primary procedure, the operative findings at revision and the clinical outcome were evaluated by reviewing the medical records, physical examination and the use of the Western Ontario shoulder instability index score, the American Shoulder and Elbow Surgeons score and the health status questionnaire 12. Recurrent instability persisted in four patients after the revision arthroscopic procedure. At the final follow-up, the mean American Shoulder and Elbow Surgeons score was 81.1 (17.5 to 99.5) and the mean Western Ontario shoulder instability index score was 68.2 (20 to 98.2). Quality-of-life scoring showed good to excellent results in most patients. Arthroscopic revision capsulolabral reconstruction can provide a satisfactory outcome in selected patients for recurrent instability of the shoulder provided that no large Hill-Sachs lesion is present


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 245 - 249
1 Feb 2017
Barnes LAF Kim HM Caldwell J Buza J Ahmad CS Bigliani LU Levine WN

Aims. Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. Patients and Methods. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. Results. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (. sd. ) 1.3) in the mini-open group; 8.9 (. sd. 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (. sd. 10.5) in mini-open group; mean 82.70 (. sd. 19.8) in the arthroscopic group; p = 0.048). Conclusion. The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245–9


Bone & Joint 360
Vol. 10, Issue 4 | Pages 37 - 40
1 Aug 2021


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching. . The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising. Cite this article: Bone Joint J 2015;97-B:1662–7


Bone & Joint 360
Vol. 10, Issue 6 | Pages 35 - 39
1 Dec 2021


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 963 - 966
1 Jul 2015
Evans JP Guyver PM Smith CD

Frozen shoulder is a recognised complication following simple arthroscopic shoulder procedures, but its exact incidence has not been reported. Our aim was to analyse a single-surgeon series of patients undergoing arthroscopic subacromial decompression (ASD; group 1) or ASD in combination with arthroscopic acromioclavicular joint (ACJ) excision (group 2), to establish the incidence of frozen shoulder post-operatively. Our secondary aim was to identify associated risk factors and to compare this cohort with a group of patients with primary frozen shoulder. We undertook a retrospective analysis of 200 consecutive procedures performed between August 2011 and November 2013. Group 1 included 96 procedures and group 2 104 procedures. Frozen shoulder was diagnosed post-operatively using the British Elbow and Shoulder Society criteria. A comparative group from the same institution involved 136 patients undergoing arthroscopic capsular release for primary idiopathic frozen shoulder. . The incidence of frozen shoulder was 5.21% in group 1 and 5.71% in group 2. Age between 46 and 60 years (p = 0.002) and a previous idiopathic contralateral frozen shoulder (p < 0.001) were statistically significant risk factors for the development of secondary frozen shoulder. Comparison of baseline characteristics against the comparator groups showed no statistically significant differences for age, gender, diabetes and previous contralateral frozen shoulder. . These results suggest that the risk of frozen shoulder following simple arthroscopic procedures is just over 5%, with no increased risk if the ACJ is also excised. Patients aged between 46 and 60 years and a previous history of frozen shoulder increase the relative risk of secondary frozen shoulder by 7.8 (95% confidence interval (CI) 2.1 to 28.3)and 18.5 (95% CI 7.4 to 46.3) respectively. Cite this article: Bone Joint J 2015; 97-B:963–6


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1556 - 1560
1 Nov 2014
Canavese F Charles YP Dimeglio A Schuller S Rousset M Samba A Pereira B Steib J

Assessment of skeletal age is important in children’s orthopaedics. We compared two simplified methods used in the assessment of skeletal age. Both methods have been described previously with one based on the appearance of the epiphysis at the olecranon and the other on the digital epiphyses. We also investigated the influence of assessor experience on applying these two methods. Our investigation was based on the anteroposterior left hand and lateral elbow radiographs of 44 boys (mean: 14.4; 12.4 to 16.1 ) and 78 girls (mean: 13.0; 11.1 to14.9) obtained during the pubertal growth spurt. A total of nine observers examined the radiographs with the observers assigned to three groups based on their experience (experienced, intermediate and novice). These raters were required to determined skeletal ages twice at six-week intervals. The correlation between the two methods was determined per assessment and per observer groups. Interclass correlation coefficients (ICC) evaluated the reproducibility of the two methods. The overall correlation between the two methods was r = 0.83 for boys and r = 0.84 for girls. The correlation was equal between first and second assessment, and between the observer groups (r ≥ 0.82). There was an equally strong ICC for the assessment effect (ICC ≤ 0.4%) and observer effect (ICC ≤ 3%) for each method. There was no significant (p < 0.05) difference between the levels of experience. The two methods are equally reliable in assessing skeletal maturity. The olecranon method offers detailed information during the pubertal growth spurt, while the digital method is as accurate but less detailed, making it more useful after the pubertal growth spurt once the olecranon has ossified. Cite this article: Bone Joint J 2014;3:1556–60


Bone & Joint 360
Vol. 10, Issue 2 | Pages 50 - 53
1 Apr 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 117 - 120
1 Jan 1998
Doi K Hattori Y Kuwata N Soo-Heong T Kawakami F Otsuka K Watanabe M

One pattern of injury to the brachial plexus shows recovery of the fifth and sixth cervical nerves but little else. These patients have useful shoulders and functional elbow flexion, but elbow and wrist extension is weak or absent. Their hand function is negligible. We restored hand function in three such patients using free functioning muscle transfer for finger flexion and transfer of the sensory rami of the intercostal nerve to the ulnar nerve for sensation. Supplementary operations to restore elbow and wrist extension were necessary in one patient


Bone & Joint Research
Vol. 2, Issue 3 | Pages 51 - 57
1 Mar 2013
Sullivan MP Torres SJ Mehta S Ahn J

Neurogenic heterotopic ossification (NHO) is a disorder of aberrant bone formation affecting one in five patients sustaining a spinal cord injury or traumatic brain injury. Ectopic bone forms around joints in characteristic patterns, causing pain and limiting movement especially around the hip and elbow. Clinical sequelae of neurogenic heterotopic ossification include urinary tract infection, pressure injuries, pneumonia and poor hygiene, making early diagnosis and treatment clinically compelling. However, diagnosis remains difficult with more investigation needed. Our pathophysiological understanding stems from mechanisms of basic bone formation enhanced by evidence of systemic influences from circulating humor factors and perhaps neurological ones. This increasing understanding guides our implementation of current prophylaxis and treatment including the use of non-steroidal anti-inflammatory drugs, bisphosphonates, radiation therapy and surgery and, importantly, should direct future, more effective ones


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 239 - 241
1 Mar 2000
Alekberov C Karatosun V Baran Ö Günal I

Patients with short congenital amputations below the elbow often function as if they have had a disarticulation of the elbow. We have reviewed the results in six patients who had lengthening of such stumps by the Ilizarov technique to improve the fitting of prostheses. The mean lengthening was 5.6 cm (3.4 to 8.4), and in two patients flexion contractures of the elbows were corrected simultaneously. Additional lateral distraction was used in one patient to provide a better surface on the stump. There were no major complications. All six patients were able to use their prosthesis at the latest follow-up after 39 to 78 months


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1745 - 1753
1 Dec 2021
Walinga AB Stornebrink T Langerhuizen DWG Struijs PAA Kerkhoffs GMMJ Janssen SJ

Aims

This study aimed to answer two questions: what are the best diagnostic methods for diagnosing bacterial arthritis of a native joint?; and what are the most commonly used definitions for bacterial arthritis of a native joint?

Methods

We performed a search of PubMed, Embase, and Cochrane libraries for relevant studies published between January 1980 and April 2020. Of 3,209 identified studies, we included 27 after full screening. Sensitivity, specificity, area under the curve, and Youden index of diagnostic tests were extracted from included studies. We grouped test characteristics per diagnostic modality. We extracted the definitions used to establish a definitive diagnosis of bacterial arthritis of a native joint per study.


Aims

To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component.

Methods

Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 2 | Pages 273 - 279
1 May 1965
El-Sharkawi AH Fattah HA

1. A method of treatment of displaced supracondylar fractures of the humerus in children by manipulative reduction and fixation in plaster in full extension of the elbow and supination of the forearm is described. 2. The method is easy, safe and requires a short period of hospitalisation. The carrying angle at the elbow can only be recorded, controlled and maintained when the elbow is extended and the forearm is fully supinated. Thus cubitus varus can be avoided. 3. The results of treatment in seventy-two displaced fractures treated by this method are reported. 4. Treatment by other methods is reviewed


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 305 - 308
1 Mar 1992
Maffulli N Chan D Aldridge M

We report overuse injuries in 14 elbows of ten elite young gymnasts. In 12 elbows of eight patients aged 11 to 15 years there was a spectrum of radiological abnormalities including widening of the olecranon physis and fragmentation of the epiphysis. The radiographs were compared with those of normal elbows matched for age and sex. The radiograph appearances were very similar to those of the Osgood-Schlatter lesion of the tibial tuberosity. Two older boys, aged 18 and 19, had stress fractures through the olecranon growth plate. Conservative management was successful in all except one case of stress fracture which required internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 234 - 239
1 Mar 1998
Kudo H

Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the bone grafts had retained most of their original size, with minimal resorption. There were no major complications such as dislocation, skin necrosis, infection or ulnar neuropathy. The study has shown that the so-called mutilans elbow can be successfully replaced using a properly selected type of non-constrained, unlinked prosthesis with bone grafting of the major defects


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 536 - 541
1 May 2001
Stiefel D Meuli M Altermatt S

The treatment of fractures of the neck of the radius in children is difficult, particularly if the angulation of the fracture exceeds 60°. Since 1994 we have used closed reduction and stabilisation with an intramedullary Kirschner wire in patients with grade-IV fractures according to the classification of Judet et al. In a retrospective analysis of a two-year period (1994 to 1996), 324 children with fractures of the elbow were treated in our department. Of these, 29 (9%) had a fracture of the neck of the radius; six were grade-IV injuries (1.9%). Five of the latter had an excellent postoperative result with normal movement of the elbow and forearm. One patient with a poor result had a concomitant dislocation of the elbow. Our results suggest that closed reduction and intramedullary pinning of grade-IV fractures allows adequate stabilisation while healing occurs


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1040 - 1044
1 Sep 2003
Ikeda M Yamashina Y Kamimoto M Oka Y

Between 1996 and 2000, we treated ten patients with severely comminuted fractures of the radial head using low-profile mini-plates. Their mean age was 42 years (24 to 71). Three fractures were Mason type III and seven were Mason-Johnston type IV. At a mean follow-up of 28.5 months (15 to 44), all fractures had united. The plates were removed in nine patients. No patient had difficulty with daily activities or symptoms of instability of the elbow. The mean range of flexion of the elbow was from 7° to 135°, with 74° of supination and 85° of pronation. According to the Broberg and Morrey functional elbow index, the mean score was 90.7 points (73 to 100), and the outcome was excellent in three patients, good in six and fair in one. These results compare favourably with those reported previously. The technique is applicable to severely comminuted fractures of the radial head which otherwise would require excision


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 430 - 439
1 Mar 2021
Geary M Gaston RG Loeffler B

Upper limb amputations, ranging from transhumeral to partial hand, can be devastating for patients, their families, and society. Modern paradigm shifts have focused on reconstructive options after upper extremity limb loss, rather than considering the amputation an ablative procedure. Surgical advancements such as targeted muscle reinnervation and regenerative peripheral nerve interface, in combination with technological development of modern prosthetics, have expanded options for patients after amputation. In the near future, advances such as osseointegration, implantable myoelectric sensors, and implantable nerve cuffs may become more widely used and may expand the options for prosthetic integration, myoelectric signal detection, and restoration of sensation. This review summarizes the current advancements in surgical techniques and prosthetics for upper limb amputees.

Cite this article: Bone Joint J 2021;103-B(3):430–439.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 297 - 299
1 Mar 1992
O'Driscoll S An K Korinek S Morrey B

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface