header advert
Results 441 - 460 of 860
Results per page:
Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims

In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures.

Methods

This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 772 - 779
1 Jun 2016
Stihsen C Hipfl C Kubista B Funovics PT Dominkus M Giurea A Windhager R

Aim. Until now, there has been no consensus as to whether stemmed acetabular components are appropriate for use in patients undergoing revision total hip arthroplasty (THA) who have major acetabular defects or pelvic discontinuity. We wished to address this deficiency in the literature. Patients and Methods. We carried out a retrospective study of 35 patients (six men and 29 women) with a mean age of 68 years (37 to 87), with major acetabular defects who underwent revision THA between 2000 and 2012. Results. At a mean follow-up of 63 months (24 to 141), a total of 15 patients (43%) had required at least one further operation. Six implants (17%) loosened aseptically, four (11%) were further revised for infection and two (6%) for technical failure. By taking revision for any reason as the endpoint, the rate of survival of the implant was 61% after five years; by taking revision for aseptic loosening as the end point, it was 78%. The cumulative five-year survival for aseptic loosening was 94% in patients without pelvic discontinuity, and 56% in those with pelvic discontinuity. Conclusion. These results indicate a significantly worse survival in patients with pelvic discontinuity (p = 0.020) and we advise caution in the use of the pedestal component in patients with major acetabular defects and pelvic discontinuity who require revision THA. As a result of these findings we have stopped using this implant and prefer to use particulate bone grafts protected with an anti-protrusion cage and posterior column plate fixation, if necessary. Take home message: Based on these poor results, we advise caution if using the pedestal component in patients with major acetabular defects with the presence of a pelvic discontinuity. . Cite this article: Bone Joint J 2016;98-B:772–9


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1736 - 1741
1 Nov 2021
Tolk JJ Eastwood DM Hashemi-Nejad A

Aims

Perthes’ disease (PD) often results in femoral head deformity and leg length discrepancy (LLD). Our objective was to analyze femoral morphology in PD patients at skeletal maturity to assess where the LLD originates, and evaluate the effect of contralateral epiphysiodesis for length equalization on proximal and subtrochanteric femoral lengths.

Methods

All patients treated for PD in our institution between January 2013 and June 2020 were reviewed retrospectively. Patients with unilateral PD, LLD of ≥ 5 mm, and long-leg standing radiographs at skeletal maturity were included. Total leg length, femoral and tibial length, articulotrochanteric distance (ATD), and subtrochanteric femoral length were compared between PD side and the unaffected side. Furthermore, we compared leg length measurements between patients who did and who did not have a contralateral epiphysiodesis.


Bone & Joint 360
Vol. 11, Issue 1 | Pages 41 - 43
1 Feb 2022


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 320 - 325
1 Mar 2016
Gundtoft PH Pedersen AB Schønheyder HC Overgaard S

Aims. The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). Patients and Methods. We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005 and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We estimated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for PJI in the DHR alone and in the DHR when combined with microbiology databases. Results. In total, 1382 of the 37 826 primary THAs in the DHR were registered as having been revised for any cause once 26 patients with errors in registration had been excluded: 232 of these were for PJI. For this group, the sensitivity was 67%, specificity 95%, PPV 77%, and NPV 92%. Combining the data from the DHR with those from microbiology databases increased the sensitivity to 90% and also improved specificity (100%), PPV (98%) and NPV (98%). Conclusion. Only two thirds of revisions for PJI were captured in the DHR and only 77% of the PJI reported to the DHR could be confirmed to be infected. . Take home message: combining the data from the DHR with those from microbiology databases substantially improved the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320–5


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 313 - 319
1 Mar 2016
Baker P Rankin K Naisby S Agni N Brewster N Holland J

Aims . The highly cross-linked polyethylene Exeter RimFit flanged cemented acetabular component was introduced in the United Kingdom in 2010. This study aimed to examine the rates of emergence of radiolucent lines observed when the Rimfit acetabular component was implanted at total hip arthroplasty (THA) using two different techniques: firstly, the ‘rimcutter’ technique in which the flange sits on a pre-prepared acetabular rim; and secondly, the ‘trimmed flange’ technique in which the flange is trimmed and the acetabular component is seated inside the rim of the acetabulum. . Patients and Methods . The radiographs of 150 THAs (75 ‘rimcutter’, 75 ‘trimmed flange’) involving this component were evaluated to assess for radiolucencies at the cement/bone interface by three observers. . Results . Rimfit acetabular components implanted using the rimcutter technique had significantly higher rates of radiolucency than those introduced using the ‘trimmed flange’ technique one year post-operatively (one zone: 63/75 (84%) vs 17/75 (23%); two zones 42/75 (56%) vs 0/75 (0%); all three zones 17/75 (23%) vs 0/75 (0%):(all p < 0.001). . Conclusion . On the basis of these findings, we have stopped using the ‘rimcutter’ technique when implanting the Rimfit acetabular component and have reverted to the ‘trimmed flange’ technique. Take home message: Surgeons should be vigilant of the performance of the Rimfit acetabular component when used alongside the rim cutter device due to an observed higher rate of progressive radiolucencies with this combination of component / technique. Cite this article: Bone Joint J 2016;98-B:313–19


Bone & Joint Research
Vol. 11, Issue 1 | Pages 23 - 25
17 Jan 2022
Matar HE Platt SR Bloch BV Board TN Porter ML Cameron HU James PJ


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 475 - 482
1 Apr 2016
Maempel JF Clement ND Ballantyne JA Dunstan E

Aims. The primary aim of this study was to investigate the effect of an enhanced recovery program (ERP) on the short-term functional outcome after total hip arthroplasty (THA). Secondary outcomes included its effect on rates of dislocation and mortality. . Patients and Methods. Data were gathered on 1161 patients undergoing primary THA which included 611 patients treated with traditional rehabilitation and 550 treated with an ERP. . Results. The ERP was shown to be a significant independent factor which shortened length of stay (LOS) by a mean of 1.5 days (95% confidence interval (CI) 1.3 to 1.8, p < 0.001) after adjusting for confounding variables. The rates of dislocation (traditional 1.03% vs ERP 0.91%, p = 0.84) and mortality (1.5% vs 0.6%, p = 0.14) one year post-operatively were not significantly different. Both groups showed significant improvement in Harris Hip Score (42.8 vs 41.5) at 12 to 18 months post-operatively and there was no significant difference in the magnitude of improvement on univariate (p = 0.09) and multivariate analysis (p = 0.35). There was no significant difference in any of the eight domain scores of the Short-Form - 36 general health surveys post-operatively (p > 0.38). . Conclusion . We conclude that an ERP after THA shortens LOS by a mean of 1.5 days and does not increase the rate of complications post-operatively. It gives equivalent functional outcomes to a traditional rehabilitation pathway. Take home message: ERP reduces LOS after THA in comparison to traditional rehabilitation, without adversely affecting functional outcomes, dislocation rates or mortality. Cite this article: Bone Joint J 2016;98-B:475–82


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 303 - 309
1 Mar 2017
Beaulé PE Bleeker H Singh A Dobransky J

Aims. Joint-preserving surgery of the hip (JPSH) has evolved considerably and now includes a number of procedures, including arthroscopy, surgical dislocation, and redirectional osteotomies of the femur and acetabulum. There are a number of different factors which lead to failure of JPSH. Consequently, it is of interest to assess the various modes of failure in order to continue to identify best practice and the indications for these procedures. . Patients and Methods. Using a retrospective observational study design, we reviewed 1013 patients who had undergone JPSH by a single surgeon between 2005 and 2015. There were 509 men and 504 women with a mean age of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies, 122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO). We analysed the overall failure rates and modes of failure. Re-operations were categorised into four groups: Mode 1 was arthritis progression or organ failure leading to total hip arthroplasty (THA); Mode 2 was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4 resulted from an unintended consequence of the initial surgical intervention. Results. At a mean follow-up of 2.5 years, there had been 104 re-operations (10.2%) with a mean patient age of 35.5 years (17 to 64). There were 64 Mode 1 failures (6.3%) at a mean of 3.2 years following JPSH with a mean patient age of 46.8 years (18 to 64). There were 17 Mode 2 failures (1.7%) at a mean of 2.2 years post-JPSH with a mean patient age of 28.9 years (17 to 42) (2% scopes; 1% surgical dislocations). There were 19 Mode 3 failures (1.9%) at a mean of 2.0 years post-JPSH, with a mean patient age of 29.9 years (18 to 51) (2% scopes; 2% surgical dislocations; 5% PAO). There were 4 Mode 4 failures (0.4%) at a mean of 1.8 years post-JPSH with a mean patient age of 31.5 years (15 to 43). Using the modified Dindo-Clavien classification system, the overall complication rate among JPSHs was 4.2%. Conclusion. While defining the overall re-operation and complication rates, it is important to define the safety and effectiveness of JPSH. Standardisation of the modes of failure may help identify the best practice. Application of these modes to large clinical series, such as registries, will assist in further establishing how to improve the efficacy of JPSH. Cite this article: Bone Joint J 2017;99-B:303–9


Bone & Joint 360
Vol. 10, Issue 4 | Pages 14 - 17
1 Aug 2021


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1279 - 1283
1 Sep 2015
Mahale YJ Aga N

In this retrospective observational cohort study, we describe 17 patients out of 1775 treated for various fractures who developed mycobacterium tuberculosis (MTB) infection after surgery. The cohort comprised 15 men and two women with a mean age of 40 years (24 to 70). A total of ten fractures were open and seven were closed. Of these, seven patients underwent intramedullary nailing of a fracture of the long bone, seven had fractures fixed with plates, two with Kirschner-wires and screws, and one had a hemiarthroplasty of the hip with an Austin Moore prosthesis. All patients were followed-up for two years. In all patients, the infection resolved, and in 14 the fractures united. Nonunion was seen in two patients one of whom underwent two-stage total hip arthroplasty (THA) and the other patient was treated using excision arthoplasty. Another patient was treated using two-stage THA. With only sporadic case reports in the literature, MTB infection is rarely clinically suspected, even in underdeveloped and developing countries, where pulmonary and other forms of TB are endemic. In developed countries there is also an increased incidence among immunocompromised patients. In this paper we discuss the pathogenesis and incidence of MTB infection after surgical management of fractures and suggest protocols for early diagnosis and management. Cite this article: Bone Joint J 2015;97-B:1279–83


Bone & Joint Research
Vol. 6, Issue 8 | Pages 499 - 505
1 Aug 2017
Morrison RJM Tsang B Fishley W Harper I Joseph JC Reed MR

Objectives. We have increased the dose of tranexamic acid (TXA) in our enhanced total joint recovery protocol at our institution from 15 mg/kg to 30 mg/kg (maximum 2.5 g) as a single, intravenous (IV) dose. We report the clinical effect of this dosage change. Methods. We retrospectively compared two cohorts of consecutive patients undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA) surgery in our unit between 2008 and 2013. One group received IV TXA 15 mg/kg, maximum 1.2 g, and the other 30 mg/kg, maximum 2.5 g as a single pre-operative dose. The primary outcome for this study was the requirement for blood transfusion within 30 days of surgery. Secondary measures included length of hospital stay, critical care requirements, re-admission rate, medical complications and mortality rates. Results. A total of 1914 THA and 2537 TKA procedures were evaluated. In THA, the higher dose of TXA was associated with a significant reduction in transfusion (p = 0.02, risk ratio (RR) 0.74, 95% confidence interval (CI) 0.58 to 0.96) and rate of re-admission (p < 0.001, RR 0.50, 95% CI 0.35 to 0.71). There were reductions in the requirement for critical care (p = 0.06, RR 0.55, 95% CI 0.31 to 1.00), and in the length of stay from 4.7 to 4.3 days (p = 0.02). In TKA, transfusion requirements (p = 0.049, RR 0.64, 95% CI 0.41 to 0.99), re-admission rate (p = 0.001, RR 0.56, 95% CI 0.39 to 0.80) and critical care requirements (p < 0.003, RR 0.34, 95% CI 0.16 to 0.72) were reduced with the higher dose. Mean length of stay reduced from 4.6 days to 3.6 days (p < 0.01). There was no difference in the incidence of deep vein thrombosis, pulmonary embolism, gastrointestinal bleed, myocardial infarction, stroke or death in THA and TKA between cohorts. Conclusion. We suggest that a single pre-operative dose of TXA, 30 mg/kg, maximum 2.5g, results in a lower transfusion requirement compared with a lower dose in patients undergoing elective primary hip and knee arthroplasty. However, these findings should be interpreted in the context of the retrospective non-randomised study design. Cite this article: R. J. M. Morrison, B. Tsang, W. Fishley, I. Harper, J. C. Joseph, M. R. Reed. Dose optimisation of intravenous tranexamic acid for elective hip and knee arthroplasty: The effectiveness of a single pre-operative dose. Bone Joint Res 2017;6:499–505. DOI: 10.1302/2046-3758.68.BJR-2017-0005.R1


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 200 - 205
1 Feb 2022
Orita K Goto K Kuroda Y Kawai T Okuzu Y Matsuda S

Aims

The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA).

Methods

We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 721 - 726
1 Jun 2006
Girard J Lavigne M Vendittoli P Roy AG

We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p < 0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 321 - 330
1 Mar 2022
Brzeszczynski F Brzeszczynska J Duckworth AD Murray IR Simpson AHRW Hamilton DF

Aims

Sarcopenia is characterized by a generalized progressive loss of skeletal muscle mass, strength, and physical performance. This systematic review primarily evaluated the effects of sarcopenia on postoperative functional recovery and mortality in patients undergoing orthopaedic surgery, and secondarily assessed the methods used to diagnose and define sarcopenia in the orthopaedic literature.

Methods

A systematic search was conducted in MEDLINE, EMBASE, and Google Scholar databases according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Studies involving sarcopenic patients who underwent defined orthopaedic surgery and recorded postoperative outcomes were included. The quality of the criteria by which a diagnosis of sarcopenia was made was evaluated. The quality of the publication was assessed using Newcastle-Ottawa Scale.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 939 - 944
1 Jul 2015
McArthur BA Abdel MP Taunton MJ Osmon DR Hanssen AD

The aim of our study was to describe the characteristics, treatment, and outcomes of patients with periprosthetic joint infection (PJI) and normal inflammatory markers after total knee arthroplasty (TKA) and total hip arthroplasty (THA). . In total 538 TKAs and 414 THAs underwent surgical treatment for PJI and met the inclusion criteria. Pre-operative erythrocyte sedimentation rate (ESR) and C-reactive protein level (CRP) were reviewed to identify the seronegative cohort. An age- and gender-matched cohort was identified from the remaining patients for comparison. Overall, 4% of confirmed infections were seronegative (21 TKA and 17 THA). Of those who underwent pre-operative aspiration, cultures were positive in 76% of TKAs (n = 13) and 64% of THAs (n = 7). Cell count and differential were suggestive of infection in 85% of TKA (n = 11) and all THA aspirates (n = 5). The most common organism was coagulase-negative Staphylococcus. Seronegative infections were associated with a lower aspirate cell count and a lower incidence of Staphylococcus aureus infection. Two-stage revision was performed in 35 cases (95%). At a mean of five years (14 to 162 months) following revision, re-operation for infection occurred in two TKAs, and one THA. From our study we estimate around 4% of patients with PJI may present with normal ESR and CRP. When performed, pre-operative aspirate is useful in delivering a definitive diagnosis. When treated, similar outcomes can be obtained compared with patients with positive serology. Cite this article: Bone Joint J 2015;97-B:939–44


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 235 - 241
1 Feb 2022
Stone B Nugent M Young SW Frampton C Hooper GJ

Aims

The success of total knee arthroplasty (TKA) is usually measured using functional outcome scores and revision-free survivorship. However, reporting the lifetime risk of revision may be more meaningful to patients when gauging risks, especially in younger patients. We aimed to assess the lifetime risk of revision for patients in different age categories at the time of undergoing primary TKA.

Methods

The New Zealand Joint Registry database was used to obtain revision rates, mortality, and the indications for revision for all primary TKAs performed during an 18-year period between January 1999 and December 2016. Patients were stratified into age groups at the time of the initial TKA, and the lifetime risk of revision was calculated according to age, sex, and the American Society of Anesthesiologists (ASA) grade. The most common indications for revision were also analyzed for each age group.


Bone & Joint Research
Vol. 4, Issue 8 | Pages 137 - 144
1 Aug 2015
Hamilton DF Giesinger JM Patton JT MacDonald DJ Simpson AHRW Howie CR Giesinger K

Objectives. The Oxford Hip and Knee Scores (OHS, OKS) have been demonstrated to vary according to age and gender, making it difficult to compare results in cohorts with different demographics. The aim of this paper was to calculate reference values for different patient groups and highlight the concept of normative reference data to contextualise an individual’s outcome. Methods. We accessed prospectively collected OHS and OKS data for patients undergoing lower limb joint arthroplasty at a single orthopaedic teaching hospital during a five-year period. T-scores were calculated based on the OHS and OKS distributions. . Results. Data were obtained from 3203 total hip arthroplasty (THA) patients and 2742 total knee arthroplasty (TKA) patients. The mean age of the patient was 68.0 years (. sd. 11.3, 58.4% women) in the THA group and in 70.2 (. sd. 9.4; 57.5% women) in the TKA group. T-scores were calculated for age and gender subgroups by operation. Different T-score thresholds are seen at different time points pre and post surgery. Values are further stratified by operation (THA/TKA) age and gender. Conclusions. Normative data interpretation requires a fundamental shift in the thinking as to the use of the Oxford Scores. Instead of reporting actual score points, the patient is rated by their relative position within the group of all patients undergoing the same procedure. It is proposed that this form of transformation is beneficial (a) for more appropriately comparing different patient cohorts and (b) informing an individual patient how they are progressing compared with others of their age and gender. Cite this article: Bone Joint Res 2015;4:137–144


Aims. To investigate the longevity of uncemented fixation of a femoral component in total hip arthroplasty (THA) in patients with Dorr type C proximal femoral morphology. Patients and Methods. A total of 350 consecutive uncemented THA in 320 patients were performed between 1983 and 1987, by a single surgeon using the Taperloc femoral component. The 63 patients (68 hips) with Dorr type C proximal femoral morphology were the focus of this review. The mean age of the patients was 69 years (24 to 88) and mean follow-up was 16.6 years (ten to 29). Survival analysis included eight patients (eight hips) who died without undergoing revision surgery prior to obtaining ten years follow-up. All 55 surviving patients (60 hips) were available for clinical assessment and radiographic review. As a comparator group, the survival and implant fixation in the remaining 282 THAs (257 patients) with Dorr type A and B morphology were evaluated. The mean age of these patients was 52 years (20 to 82). Results. In the Dorr C patient group the mean Harris hip score improved from 51 points (21 to 69 points) pre-operatively to 89 (74 to 100) at final follow-up. No femoral component was loose by radiological criteria and osteolysis was only identified around two stems (3.3%). There was one revision (1.6%) of a well-fixed femoral component for sepsis at 11 years. The survival of the Taperloc femoral component at 20 years with revision for any reason as the endpoint was 98% (95% confidence interval; 87 to 99). A total of ten (3.5%) of the Dorr A and B patient group of 282 THAs required revision surgery. Only one (0.4%) for aseptic loosening. A total of two hips (1%) were loose by radiographic criteria and osteolysis occurred around 12 hips (4%). Conclusion. This study demonstrates that excellent fixation can be achieved using the Taperloc stem in patients with Dorr type A and B, and Dorr type C bone. Take home message: The Taperloc stem demonstrated equivalent results in Dorr type A and B and Dorr type C bone. Cite this article: Bone Joint J 2016;98-B:595–600