There is a large amount of evidence available
about the relative merits of unicompartmental and total knee arthroplasty
(UKA and TKA). Based on the same evidence, different people draw
different conclusions and as a result, there is great variability
in the usage of UKA. The revision rate of UKA is much higher than TKA and so some
surgeons conclude that UKA should not be performed. Other surgeons
believe that the main reason for the high revision rate is that
UKA is easy to revise and, therefore, the threshold for revision
is low. They also believe that UKA has many advantages over TKA
such as a faster recovery, lower morbidity and mortality and better
function. They therefore conclude that UKA should be undertaken
whenever appropriate. The solution to this argument is to minimise the revision rate
of UKA, thereby addressing the main disadvantage of UKA. The evidence
suggests that this will be achieved if surgeons use UKA for at least
20% of their knee arthroplasties and use implants that are appropriate
for these broad indications. Cite this article:
Total knee replacement (TKR) is an operation
that can be performed with or without the use of a tourniquet. Meta-analyses
of the available Level-1 studies have demonstrated that the use
of a tourniquet leads to a significant reduction in blood loss.
The opponents for use of a tourniquet cite development of complications
such as skin bruising, neurovascular injury, and metabolic disturbance
as drawbacks. Although there may certainly be reason for concern
in arteriopathic patients, there is little evidence that routine
use of a tourniquet during TKR results in any of the above complications.
The use of a tourniquet, on the other hand, provides a bloodless
field that allows the surgeon to perform the procedure with expediency
and optimal visualisation. Blood conservation has gained great importance
in recent years due to increased understanding of the problems associated
with blood transfusion, such as increased surgical site infection
(due to immunomodulation effect), increased length of hospital stay
and increased cost. Based on the authors’ understanding of the available
evidence, the routine use of a tourniquet during TKR is justified
as good surgical practice. Cite this article:
We wanted to investigate regional variations in the organisms
reported to be causing peri-prosthetic infections and to report
on prophylaxis regimens currently in use across England. Analysis of data routinely collected by Public Health England’s
(PHE) national surgical site infection database on elective primary
hip and knee arthroplasty procedures between April 2010 and March
2013 to investigate regional variations in causative organisms.
A separate national survey of 145 hospital Trusts (groups of hospitals
under local management) in England routinely performing primary
hip and/or knee arthroplasty was carried out by standard email questionnaire.Objectives
Methods
This study reports on the first 150 consecutive
Oxford cementless unicompartmental knee arthroplasties (UKA) performed
in an independent centre (126 patients). All eligible patients had
functional scores (Oxford knee score and high activity arthroplasty
score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically
aligned radiographs were taken at five years and analysed for any
evidence of radiolucent lines (RLLs), subsidence or loosening. The
mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%)
males. Excellent functional scores were maintained at five years
and there were no progressive RLLs demonstrated on radiographs.
Two patients underwent revision to a total knee arthroplasty giving
a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84)
component years with overall component survivorship of 98.7% at
five years. There were a further four patients who underwent further
surgery on the same knee, two underwent bearing exchanges for dislocation
and two underwent lateral UKAs for disease progression. This was
a marked improvement from other UKAs reported in New Zealand Joint
Registry data and supports the designing centre’s early results. Cite this article:
The aim of this study was to analyse the gait
pattern, muscle force and functional outcome of patients who had undergone
replacement of the proximal tibia for tumour and alloplastic reconstruction
of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide
local excision of a primary sarcoma of the proximal tibia, proximal
tibial replacement and reconstruction of the extensor mechanism
using the patellar-loop technique in 18 patients. Of these, nine
were available for evaluation after a mean of 11.6 years (0.5 to
21.6). The strength of the knee extensors was measured using an
Isobex machine and gait analysis was undertaken in our gait assessment
laboratory. Functional outcome was assessed using the American Knee
Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time,
flexion heel strike, maximal flexion loading response and total
sagittal plane excursion. The mean maximum active flexion was 91°
(30° to 110°). The overall mean extensor lag was 1° (0° to 5°).
The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that
in the non-operated leg (p <
0.001). The mean functional scores
were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional
score). In summary, the results show that reconstruction of the extensor
mechanism using this technique gives good biomechanical and functional
results. The patients’ gait pattern is close to normal, except for
a somewhat stiff knee gait pattern. The strength of the extensor
mechanism is reduced, but sufficient for walking. Cite this article:
The June 2015 Knee Roundup360 looks at: Cruciate substituting
Osteoporosis and abnormal bone metabolism may prove to be significant
factors influencing the outcome of arthroplasty surgery, predisposing
to complications of aseptic loosening and peri-prosthetic fracture.
We aimed to investigate baseline bone mineral density (BMD) and
bone turnover in patients about to undergo arthroplasty of the hip
and knee. We prospectively measured bone mineral density of the hip and
lumbar spine using dual-energy X-ray absorptiometry (DEXA) scans
in a cohort of 194 patients awaiting hip or knee arthroplasty. We
also assessed bone turnover using urinary deoxypyridinoline (DPD),
a type I collagen crosslink, normalised to creatinine.Aims
Methods
Blood loss during total knee replacement (TKR)
remains a significant concern. In this study, 114 patients underwent TKR,
and were divided into two groups based on whether they received
a new generation fibrin sealant intra-operatively, or a local infiltration
containing adrenaline. Groups were then compared for mean calculated
total blood volume (TBV) loss, transfusion rates, and knee range
of movement. Mean TBV loss was similar between groups: fibrin sealant
mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml
(261 to 2308) (p = 0.929). Overall, significantly fewer units of
blood were transfused in the fibrin sealant group (seven units)
compared with the local adrenaline group (15 units) (p = 0.0479).
Per patient transfused, significantly fewer units of blood were transfused
in the fibrin sealant group (1.0 units) compared with the local
adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin
sealant may reduce the need for multiple unit transfusions. Knee
range of movement was similar between groups. From our results,
it appears that application of this newer fibrin sealant results
in blood loss and transfusion rates that are low and similar to
previously applied fibrin sealants. Cite this article:
Revision knee arthroplasty presents a number
of challenges, not least of which is obtaining solid primary fixation
of implants into host bone. Three anatomical zones exist within
both femur and tibia which can be used to support revision implants.
These consist of the joint surface or epiphysis, the metaphysis
and the diaphysis. The methods by which fixation in each zone can
be obtained are discussed. The authors suggest that solid fixation
should be obtained in at least two of the three zones and emphasise
the importance of pre-operative planning and implant selection. Cite this article:
This cohort study investigated the influence
of psychological factors, including perception of illness, anxiety
and depression on recovery and functional outcome after total knee
replacement surgery. A total of 100 patients (55 male; 45 female) with a mean age
of 71 (42 to 92) who underwent a primary total knee replacement
for osteoarthritis were recruited into this study. In all 97 participants
completed the six week and 87 the one year follow-up questionnaires. Pre-operatively patients completed the revised Illness Perception
Questionnaire, Hospital Anxiety and Depression Scale and Recovery
Locus of Control Scale. Function was assessed pre-operatively, at
six weeks and one year using Oxford Knee Score (OKS) and the goniometer-measured
range of movement (ROM). The results showed that pre-operative function had the biggest
impact on post-operative outcome for ROM and OKS. In addition questionnaire
variables and depression had an impact on the OKS at six weeks.
Depression and anxiety were also associated with a higher (worse)
knee score at one year but did not influence the ROM at either six weeks
or one year. Recovery from total knee replacement can be difficult to predict.
This study has identified psychological factors that play an important
role in recovery from surgery and functional outcome. These should
be taken into account when considering patients for total knee replacement. Cite this article:
The February 2015 Knee Roundup360 looks at: Intra-operative sensors for knee balance; Mobile bearing no advantage; Death and knee replacement: a falling phenomenon; The swings and roundabouts of unicompartmental arthroplasty; Regulation, implants and innovation; The weight of arthroplasty responsibility!; BMI in arthroplasty
The outcome of total knee replacement (TKR) using
components designed to increase the range of flexion is not fully
understood. The short- to mid-term risk of aseptic revision in high
flexion TKR was evaluated. The endpoint of the study was aseptic
revision and the following variables were investigated: implant
design (high flexion In a cohort of 64 000 TKRs, high flexion components were used
in 8035 (12.5%). The high flexion knees with tibial liners of thickness
>
14 mm had a density of revision of 1.45/100 years of observation,
compared with 0.37/100 in non-high flexion TKR with liners ≤ 14
mm thick. Relative to a standard fixed PS TKR, the NexGen (Zimmer,
Warsaw, Indiana) Gender Specific Female high flexion fixed PS TKR
had an increased risk of revision (hazard ratio (HR) 2.27 (95% confidence
interval (CI) 1.48 to 3.50)), an effect that was magnified when
a thicker tibial insert was used (HR 8.10 (95% CI 4.41 to 14.89)). Surgeons should be cautious when choosing high flexion TKRs,
particularly when thicker tibial liners might be required. Cite this article:
The outcome of high tibial osteotomy (HTO) deteriorates
with time, and additional procedures may be required. The aim of
this study was to compare the clinical and radiological outcomes
between unicompartmental knee replacement (UKR) and total knee replacement
(TKR) after HTO as well as after primary UKR. A total of 63 patients (63
knees) were studied retrospectively and divided into three groups:
UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18)
and primary UKR (group C; n = 22). The Oxford knee score (OKS),
Knee Society score (KSS), hip–knee–ankle angles, mechanical axis
and patellar height were evaluated pre- and post-operatively. At
a mean of 64 months (19 to 180) post-operatively the mean OKS was
43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups
A, B and C, respectively (p = 0.73). The mean KSS knee score was
88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups
A, B and C, respectively (p = 0.65), and the mean KSS function score
was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and
79.3 (50 to 100) in group C (p = 0.48). Radiologically the results
were comparable for all groups except for patellar height, with
a higher incidence of patella infra following a previous HTO (p
= 0.02). Cite this article:
The June 2013 Knee Roundup360 looks at: knee arthroplasty in diabetic patients; whether TKR is a timebomb; the use of antidepressants for knee OA; trochleoplasty; articulated spacers; mental health and joint replacement; and the use of physiotherapy for meniscal tear.
Instability after total knee replacement (TKR)
accounts for 10% to 22% of revision procedures. All patients who
present for evaluation of instability require a thorough history to
be taken and physical examination, as well as appropriate imaging.
Deep periprosthetic infection must be ruled out by laboratory testing
and an aspiration of the knee must be carried out. The three main
categories of instability include flexion instability, extension instability
(symmetric and asymmetric), and genu recurvatum. Most recently,
the aetiologies contributing to, and surgical manoeuvres required
to correct, flexion instability have been elucidated. While implant
design and patient-related factors may certainly contribute to the
aetiology, surgical technique is also a significant factor in all
forms of post-operative instability. Cite this article:
Metaphyseal bone loss is common with revision
total knee replacement (RTKR). Using the Anderson Orthopaedic Research
Institute (AORI) classification, type 2-B and type 3 defects usually
require large metal blocks, bulk structural allograft or highly
porous metal cones. Tibial and femoral trabecular metal metaphyseal
cones are a unique solution for large bone defects. These cones
substitute for bone loss, improve metaphyseal fixation, help correct
malalignment, restore the joint line and may permit use of a shorter
stem. The technique for insertion involves sculpturing of the remaining
bone with a high speed burr and rasp, followed by press-fit of the
cone into the metaphysis. The fixation and osteoconductive properties
of the porous cone outer surface allow ingrowth and encourage long-term
biological fixation. The revision knee component is then cemented
into the porous cone inner surface, which provides superior fixation
compared with cementing into native but deficient metaphyseal bone.
The advantages of the cone compared with allograft include: technical
ease, biological fixation, no resorption, and possibly a lower risk
of infection. The disadvantages include: difficult extraction and
relatively short-term follow-up. Several studies using cones report
promising short-term results for the reconstruction of large bone
defects in RTKR. Cite this article:
The Unified Classification System (UCS) was introduced
because of a growing need to have a standardised universal classification
system of periprosthetic fractures. It combines and simplifies many
existing classification systems, and can be applied to any fracture
around any partial or total joint replacement occurring during or
after operation. Our goal was to assess the inter- and intra-observer
reliability of the UCS in association with knee replacement when
classifying fractures affecting one or more of the femur, tibia
or patella. We used an international panel of ten orthopaedic surgeons with
subspecialty fellowship training and expertise in adult hip and
knee reconstruction (‘experts’) and ten residents of orthopaedic
surgery in the last two years of training (‘pre-experts’). They
each received 15 radiographs for evaluation. After six weeks they
evaluated the same radiographs again but in a different order. The reliability was assessed using the Kappa and weighted Kappa
values. The Kappa values for inter-observer reliability for the experts
and the pre-experts were 0.741 (95% confidence interval (CI) 0.707
to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted
Kappa values for intra-observer reliability for the experts and
pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI
0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near
perfect’ intra-observer reliability when used for periprosthetic
fractures in association with knee replacement in the hands of experienced
and inexperienced users. Cite this article:
Previous studies of failure mechanisms leading
to revision total knee replacement (TKR) performed between 1986 and
2000 determined that many failed early, with a disproportionate
amount accounted for by infection and implant-associated factors
including wear, loosening and instability. Since then, efforts have
been made to improve implant performance and instruct surgeons in
best practice. Recently our centre participated in a multi-centre evaluation
of 844 revision TKRs from 2010 to 2011. The purpose was to report
a detailed analysis of failure mechanisms over time and to see if
failure modes have changed over the past 10 to 15 years. Aseptic
loosening was the predominant mechanism of failure (31.2%), followed
by instability (18.7%), infection (16.2%), polyethylene wear (10.0%),
arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to
failure was 5.9 years (ten days to 31 years), 35.3% of all revisions
occurred at less than two years, and 60.2% in the first five years.
With improvements in implant and polyethylene manufacture, polyethylene
wear is no longer a leading cause of failure. Early mechanisms of
failure are primarily technical errors. In addition to improving
implant longevity, industry and surgeons must work together to decrease
these technical errors. All reports on failure of TKR contain patients
with unexplained pain who not infrequently have unmet expectations.
Surgeons must work to achieve realistic patient expectations pre-operatively,
and therefore, improve patient satisfaction post-operatively. Cite this article:
The December 2012 Knee Roundup360 looks at: the demand for knee replacement; a Japanese knee outcome score; smoking and TKR; coronal alignment as a determinant of outcome in TKR; fixed flexion; MRI detected knee lesions; and lateral domed Oxford unicompartmental knee replacements.
The optimal timing of total knee replacement
(TKR) in patients with osteoarthritis, in relation to the severity
of disease, remains controversial. This prospective study was performed
to investigate the effect of the severity of osteoarthritis and
other commonly available pre- and post-operative clinical parameters
on the clinical outcome in a consecutive series of cemented TKRs.
A total of 176 patients who underwent unilateral TKR were included
in the study. Their mean age was 68 years (39 to 91), 63 (36%) were
male and 131 knees (74%) were classified as grade 4 on the Kellgren–Lawrence
osteoarthritis scale. A total of 154 patients (87.5%) returned for
clinical review 12 months post-operatively, at which time the outcome
was assessed using the Knee Society score. A low radiological severity of osteoarthritis was not associated
with pain 12 months post-operatively. However, it was significantly
associated with an inferior level of function (p = 0.007), implying
the need for increased focus on all possible reasons for pain in
the knee and the forms of conservative treatment which are available
for patients with lower radiological severity of osteoarthritis. Cite this article: