Tsang SJ Simpson AHRW


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 186 - 188
1 Feb 2007
Rodriguez-Merchan EC

The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late deep infection which required a two-stage revision arthroplasty, with a good final result. The incidence of infection in HIV-positive and negative patients was thus similar. One knee in a patient with inhibitor had excessive bleeding due to a pseudoaneurysm which required embolisation. The results were excellent in 27 knees (77%), good in six (17%) and fair in two (6%). The survival rate at 7.5 years taking removal of the prosthesis for loosening or infection as the end-point was 97%. The mechanical survival of total knee replacements in haemophiliacs is very good. Our results confirm that this is a reproducible procedure in haemophilia, even in HIV-positive patients with a CD4 count > 200 mm. 3. and those with inhibitors. Our rate of infection was lower than previously reported. This could be due to better control of the HIV status with highly active anti-retroviral therapy and the use of antibiotic-loaded cement


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 777 - 781
1 Nov 1989
Nilsson L Stromqvist B Thorngren K

We report a series of 640 consecutive cervical hip fractures which were followed prospectively for two years after primary internal fixation with two hook-pins. Secondary arthroplasties were performed as salvage procedures in 75 cases and the early outcome of these was studied retrospectively. The mean time in hospital was 25 days for prosthetic replacement, though 60% of the patients had other medical conditions considered as risk factors. Mortality was 5% after six months and 8% after one year. Dislocation was seen in 11% and additional surgery was required in 4%. There was one case of deep infection and one supracondylar femoral fracture. In some cases there was considerable delay between the primary and secondary operation due to lack of awareness of functional deterioration, but although many patients had poor mobility before the secondary operation this was greatly improved within six weeks of the arthroplasty. We conclude that elective secondary hip arthroplasty for failure of fracture fixation is a safe and successful procedure. Once the decision to perform an arthroplasty is taken, this should be done without delay to avoid deterioration of function


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 359 - 363
1 Apr 2001
Back DL Cannon SR Hilton A Bankes MJK Briggs TWR

We reviewed the outcome of 422 primary cemented Kinemax total knee arthroplasties implanted into 369 patients over a period of five years, from January 1989. The operations were carried out at two NHS district general hospitals and one teaching hospital by 31 surgeons. During the period of review, 49 patients died and ten knees were lost to follow-up (68 knees). The mean Knee Society score improved from 28 before to 89 after surgery, and the mean function score increased from 23 to 79. The range of flexion improved from 92° to 105°. These improvements were maintained throughout the period of study. At the latest review radiolucent lines of 1 mm were seen around 15% of tibial components, 1.4% of patellar components and 9.5% of femoral components. In no case were these changes progressive. Using revision as the endpoint, cumulative survival was 99% after five years and 96.95% after nine years. All revisions were undertaken for deep infection or secondary trauma. Our study has shown that the Kinemax total knee replacement, when carried out with retention of the posterior cruciate ligament by surgeons of varying experience, produces very satisfactory results in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 177 - 182
1 Mar 2001
Taylor AH Shannon M Whitehouse SL Lee MB Learmonth ID

We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 ± 14.7 to 94 ± 6.8. Radiologically, there was no evidence of acetabular migration. The rate of revision for the femoral component was 8.6%, three being undertaken for loosening and three to allow downsizing of the femoral head. The rate of revision for the acetabular component was 7.1% (five cups). At the time of revision none of the cups was clinically loose, and only required the liner to be changed. The rate of complications was low with no case of deep infection or dislocation, but nine of the 76 hips (11.8%) showed grade-III heterotopic ossification. Previous studies of patients undergoing cemented total hip arthroplasty for the treatment of advanced avascular necrosis have indicated a high incidence of loosening of the acetabular component. Our findings show good medium-term results using the Harris Galante Porous cup for acetabular reconstruction, together with a variety of cemented femoral components, for the treatment of this difficult problem


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 299 - 302
1 Mar 1995
Deo S Gibbons C Emerton M Simpson A

Of 1197 renal transplant recipients on the Oxford Transplant Programme, 25 (2%) needed arthroplasties for painful osteonecrosis of the hip. Nine of them had bilateral operations, giving a total of 34 primary total hip replacements (THR). The mean time from onset of symptoms to THR was 2.4 years and from transplantation to THR 5.1 years. The mean follow-up was 5.1 (1 to 14) years. THR relieved the pain in all the patients, but survival analysis indicated a lower survival rate than is usual for primary THR. There were eight major complications. One graft-related problem, early acute tubular necrosis, resolved rapidly after immediate treatment. One patient developed deep infection at 3.5 years after THR which settled with conservative treatment. Five hips developed aseptic loosening requiring revision arthroplasty at a mean of 8.8 years' follow-up. One patient had a non-fatal pulmonary embolism. THR is the treatment of choice for patients with painful osteonecrosis of the hip after renal transplant, but has higher rates of both early and late complications. Surgery should be performed in close association with a renal transplant unit


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 34 - 39
1 Jan 1994
Izquierdo R Northmore-Ball M

We report a clinical and radiological survival analysis of 148 consecutive revisions of hip arthroplasties. All patients referred were offered revision if it was indicated and they were medically fit. About one-third (32%) had had at least one previous revision, and about one-third had an established deep infection. The revisions were performed in ultra-clean air with body-exhaust suits. The usual method of fixation was by contained and pressurised cement of standard viscosity, to which appropriate antibiotics had been added in infected cases. Some patients had cementless revision. Clinical failure meant that one or both of the implants had been removed; radiological failure was assessed from serial radiographs. The clinical survival at ten years was 95%. The Merle D'Aubigne and Postel rating for pain improved from a mean of 2.9 to 5.2; and in Charnley group A and B cases, walking ability improved from 2.3 to 4.3. In contrast to some reports we also found good radiological survival; this was 90.5% for cemented femoral stems. Isoelastic revision stems inserted without cement gave poor results


Bone & Joint Research
Vol. 9, Issue 11 | Pages 778 - 788
1 Nov 2020
Xu H Yang J Xie J Huang Z Huang Q Cao G Pei F

Aims

The efficacy and safety of intrawound vancomycin for preventing surgical site infection in primary hip and knee arthroplasty is uncertain.

Methods

A systematic review of the literature was conducted, indexed from inception to March 2020 in PubMed, Web of Science, Cochrane Library, Embase, and Google Scholar databases. All studies evaluating the efficacy and/or safety of intrawound vancomycin in patients who underwent primary hip and knee arthroplasty were included. Incidence of periprosthetic joint infection (PJI), superficial infection, aseptic wound complications, acute kidney injury, anaphylactic reaction, and ototoxicity were meta-analyzed. Results were reported as odds ratios (ORs) and 95% confidence intervals (CIs). The quality of included studies was assessed using the risk of bias in non-randomized studies of interventions (ROBINS-I) assessment tool.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 822 - 831
1 Jul 2020
Kuroda Y Saito M Çınar EN Norrish A Khanduja V

Aims

This paper aims to review the evidence for patient-related factors associated with less favourable outcomes following hip arthroscopy.

Methods

Literature reporting on preoperative patient-related risk factors and outcomes following hip arthroscopy were systematically identified from a computer-assisted literature search of Pubmed (Medline), Embase, and Cochrane Library using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines and a scoping review.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 19 - 26
1 Jan 2011
Kim Y Kim J Park J Joo J

Our aim was to determine the success rate of repeated debridement and two-stage cementless revision arthroplasty according to the type of infected total hip replacement (THR). We enrolled 294 patients (294 hips) with an infected THR in the study. There were 222 men and 72 women with a mean age of 55.1 years (24.0 to 78.0). The rate of control of infection after the initial treatment and after repeated debridement and two-stage revisions was determined. The clinical (Harris hip score) and radiological results were evaluated. The mean follow-up was 10.4 years (5.0 to 14.0). The eventual rate of control of infection was 100.0% for early superficial post-operative infection, 98.4% for early deep post-operative infection, 98.5% for late chronic infection and 91.0% for acute haematogenous infection. Overall, 288 patients (98%) maintained a functioning THR at the latest follow-up. All the allografts appeared to be united and there were no failures. These techniques effectively controlled infection and maintained a functional THR with firm fixation in most patients. Repeated debridement and two-stage or repeated two-stage revisions further improved the rate of control of infection after the initial treatment and increased the likelihood of maintaining a functional THR


Bone & Joint 360
Vol. 9, Issue 5 | Pages 44 - 46
1 Oct 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 190 - 194
1 Mar 2004
Bizot P Hannouche D Nizard R Witvoet J Sedel L

Between 1990 and 1992, we implanted 71 hybrid alumina-on-alumina hip arthroplasties in 62 consecutive patients under the age of 55 years, with a mean age of 46 years at surgery. There were 56 primary and 15 secondary procedures. The prostheses involved a cemented titanium alloy stem, a 32 mm alumina head, and a press-fit metal-backed socket with an alumina insert. Three patients (four hips) died from unrelated causes. Four hips had revision surgery for either deep infection, unexplained persistent pain, fracture of the alumina head, or aseptic loosening of the socket. The nine-year survival rate was 93.7% with revision for any cause as the end-point and 98.4% with revision for aseptic loosening as the end-point. The outcome in the surviving patients (50 patients, 57 hips) with a minimum five-year follow-up (mean eight years) was excellent in 47 hips (82.5%), very good in eight (14%), good in one and fair in one. A thin, partial, lucent line, mainly in zone III was present in 38% of the sockets and one socket had a complete lucency less than 1 mm thick. One stem had isolated femoral osteolysis. There was no detectable component migration nor acetabular osteolysis. This hybrid arthroplasty gave satisfactory medium-term results in active patients. The press-fit metal-backed socket appeared to have reliable fixation in alumina-on-alumina hip arthroplasty. The excellent results using cemented fixation of the stem may be related to the low production of wear debris


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 538 - 542
1 Aug 1985
Kakkar V Fok P Murray W Paes T Merenstein D Dodds R Farrell R Crellin R Thomas E Morley T et A

A prospective study involving 500 consecutive patients undergoing hip replacement was performed to find out whether a combination of heparin and dihydroergotamine was effective in preventing postoperative fatal and non-fatal emboli. Deep-vein thrombosis was demonstrated in 131 cases (26.2%), in 99 of whom thrombi were confined to the ipsilateral (operated) limb and in 13 to the contralateral limb; 19 patients developed bilateral thrombi. Nine patients (1.8%) died during the first four weeks after operation, before they were discharged from hospital; in one, major emboli were demonstrated in the right pulmonary artery. Three of the 500 patients developed non-fatal pulmonary emboli. Excessive bleeding occurred in 21 (4.2%) and in 19 of these prophylaxis was discontinued. Wound haematomas developed in 25 patients (5.0%); only six required evacuation but in none of these six did deep infection occur while in hospital; in three patients, however, the wound haematoma prolonged the stay in hospital. Thus the combination of heparin and dihydroergotamine proved an effective prophylaxis against pulmonary embolism in patients undergoing total hip replacement. The risk of bleeding complications is wholly acceptable when balanced against the advantages of the therapy


Bone & Joint Open
Vol. 1, Issue 7 | Pages 405 - 414
15 Jul 2020
Abdelaal A Munigangaiah S Trivedi J Davidson N

Aims

Magnetically controlled growing rods (MCGR) have been gaining popularity in the management of early-onset scoliosis (EOS) over the past decade. We present our experience with the first 44 MCGR consecutive cases treated at our institution.

Methods

This is a retrospective review of consecutive cases of MCGR performed in our institution between 2012 and 2018. This cohort consisted of 44 children (25 females and 19 males), with a mean age of 7.9 years (3.7 to 13.6). There were 41 primary cases and three revisions from other rod systems. The majority (38 children) had dual rods. The group represents a mixed aetiology including idiopathic (20), neuromuscular (13), syndromic (9), and congenital (2). The mean follow-up was 4.1 years, with a minimum of two years. Nine children graduated to definitive fusion. We evaluated radiological parameters of deformity correction (Cobb angle), and spinal growth (T1-T12 and T1-S1 heights), as well as complications during the course of treatment.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 184 - 191
1 Jan 2021
Perrin DL Visgauss JD Wilson DA Griffin AM Abdul Razak AR Ferguson PC Wunder JS

Aims

Local recurrence remains a challenging and common problem following curettage and joint-sparing surgery for giant cell tumour of bone (GCTB). We previously reported a 15% local recurrence rate at a median follow-up of 30 months in 20 patients with high-risk GCTB treated with neoadjuvant Denosumab. The aim of this study was to determine if this initial favourable outcome following the use of Denosumab was maintained with longer follow-up.

Methods

Patients with GCTB of the limb considered high-risk for unsuccessful joint salvage, due to minimal periarticular and subchondral bone, large soft tissue mass, or pathological fracture, were treated with Denosumab followed by extended intralesional curettage with the goal of preserving the joint surface. Patients were followed for local recurrence, metastasis, and secondary sarcoma.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 67 - 72
1 Jan 1995
Morrey B Adams R

We have reviewed 36 of 39 consecutive patients with an average age of 68 years who had semiconstrained elbow replacement for distal humeral nonunion at an average follow-up of 50.4 months (24 to 127). Of these, 31 (86%) had satisfactory results, three (8%) had fair, and two (6%) had poor results; 32 patients (88%) had moderate or severe pain before and 91% had no or only mild discomfort after the procedure. Motion had improved from a mean arc of 29 degrees to 103 degrees before operation to 16 degrees to 127 degrees after surgery. All five flail extremities were stable at last assessment. There were seven complications (18%): two patients had deep infection, two had particulate synovitis, two had ulnar neuropathy and one had worn polyethylene bushes. Five of these seven, excluding the two with transient nueropathy, required reoperation (13%). Joint replacement arthroplasty can be a safe and reliable treatment for this difficult clinical condition, seen most commonly in elderly patients. This is a significant advance, since repeated osteosynthesis has been shown to be ineffective in most patients


Bone & Joint 360
Vol. 9, Issue 5 | Pages 37 - 41
1 Oct 2020


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 280 - 284
1 Mar 2020
Ogura K Boland PJ Fabbri N Healey JH

Aims

Although internal hemipelvectomy is associated with a high incidence of morbidity, especially wound complications, few studies have examined rates of wound complications in these patients or have identified factors associated with the consequences. The present study aimed to: 1) determine the rate of wound and other complications requiring surgery after internal hemipelvectomy; and 2) identify factors that affect the rate of wound complications and can be used to stratify patients by risk of wound complications.

Methods

The medical records of 123 patients undergoing internal hemipelvectomy were retrospectively reviewed, with a focus on both overall complications and wound complications. Logistic regression analyses were performed to examine the association between host, tumour, and surgical factors and rates of postoperative wound complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 220 - 225
1 Mar 1996
Abernethy PJ Robinson CM Fowler RM

We reviewed 1567 elective knee replacements performed between 1980 and 1990, using either the Total Condylar prosthesis with an all-plastic tibial component, or the Kinematic prosthesis which has a metal tibial tray. The ten-year probability of survival was 92.1% for the Total Condylar design and 87.9% for the Kinematic. The difference was mainly due to 16 revisions required in the Kinematic series for fracture of the metal base-plate. This was the most common cause of aseptic failure in this group. These fractures were strongly associated with a preoperative varus deformity (hazard ratio (HR) 8.8) and there was a slightly increased risk in males (HR 1.9) and in osteoarthritic knees (HR 1.8). In the nine fractures which occurred within four years of primary implantation (group 1), failure to correct adequately a preoperative varus deformity and the use of a bone graft to correct such a deformity were both strongly associated with fracture (HR 13.9 and 15.8, respectively). In eight fractures which occurred more than five years after primary replacement (group 2) we could detect no significant risk factors. Early complications occurred in two patients after the 16 revision procedures for tray fracture. One had a deep infection and the other refracture of the tray


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 178 - 184
1 Mar 1996
Marston RA Cobb AG Bentley G

From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including femoral head size with longevity. There were 213 Stanmore hips and 200 Charnley prostheses. At five to ten years (mean 6.5) 76 patients had died and 16 arthroplasties had required revision. Seven were radiologically loose in asymptomatic patients. There was only one case of deep infection. We found no difference statistically in the clinical outcome or in the revision rate of 4% in the two types of prosthesis. The revision rate was greater for trainees than for senior operating surgeons, and there were recognisable technical errors in seven of the nine Stanmore, and four of the seven Charnley replacements which required revision. Retrospective radiological analysis of a random subset of 51 Charnley and 57 Stanmore femoral components showed no difference in femoral subsidence, but in 14 patients who had had bilateral replacements with one femoral component of each type, there was greater early subsidence of the Stanmore prosthesis. Our results confirm that conventional cemented total hip replacements give acceptable results in a general teaching unit, and we found no evidence of any effect of the size of the femoral head on wear or loosening at five to ten years