Advertisement for orthosearch.org.uk
Results 421 - 429 of 429
Results per page:
Bone & Joint 360
Vol. 5, Issue 2 | Pages 13 - 16
1 Apr 2016


Bone & Joint 360
Vol. 5, Issue 1 | Pages 14 - 16
1 Feb 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1455 - 1456
1 Nov 2012
Oussedik S Gould K Stockley I Haddad FS

Peri-prosthetic infection remains a leading cause of revision surgery. Recent publications from the American Musculoskeletal Infection Society have sought to establish a definition of peri-prosthetic infection based on clinical findings and laboratory investigations. The limitations of their approach are discussed and an alternative definition is proposed, which it is felt may better reflect the uncertainties encountered in clinical practice.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1024 - 1030
1 Aug 2015
Whitehouse MR Endo M Zachara S Nielsen TO Greidanus NV Masri BA Garbuz DS Duncan CP

Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty (THA). Modular junctions are a potential source of such wear products and are associated with secondary pseudotumour formation.

We present a consecutive series of 17 patients treated at our unit for this complication following metal-on-highly cross-linked polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as infection, and present the aggregate laboratory results and pathological findings in this series.

The clinical presentation was pain, swelling or instability. Solid, cystic and mixed soft-tissue lesions were noted on imaging and confirmed intra-operatively. Corrosion at the head–neck junction was noted in all cases. No bacteria were isolated on multiple pre- and intra-operative samples yet the mean erythrocyte sedimentation rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and stromal polymorphonuclear cell counts were noted in nine cases.

Adverse soft–tissue reactions can occur in MoP THA owing to corrosion products released from the head–neck junction. The diagnosis should be carefully considered when investigating pain after THA. This may avoid the misdiagnosis of periprosthetic infection with an unidentified organism and mitigate the unnecessary management of these cases with complete single- or two-stage exchange.

Cite this article: Bone Joint J 2015;97-B:1024–1030.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 244 - 249
1 Feb 2013
Puig-Verdié L Alentorn-Geli E González-Cuevas A Sorlí L Salvadó M Alier A Pelfort X Portillo ME Horcajada JP

The purpose of this study was to compare the diagnostic accuracy for the detection of infection between the culture of fluid obtained by sonication (SFC) and the culture of peri-implant tissues (PITC) in patients with early and delayed implant failure, and those with unsuspected and suspected septic failure. It was hypothesised that SFC increases the diagnostic accuracy for infection in delayed, but not early, implant failure, and in unsuspected septic failure. The diagnostic accuracy for infection of all consecutive implants (hardware or prostheses) that were removed for failure was compared between SFC and PITC. This prospective study included 317 patients with a mean age of 62.7 years (9 to 97). The sensitivity for detection of infection using SFC was higher than using PITC in an overall comparison (89.9% versus 67%, respectively; p < 0.001), in unsuspected septic failure (100% versus 48.5%, respectively; p < 0.001), and in delayed implant failure (88% versus 58%, respectively; p < 0.001). PITC sensitivity dropped significantly in unsuspected compared with suspected septic failure (p = 0.007), and in delayed compared with early failure (p = 0.013). There were no differences in specificity.

Sonication is mainly recommended when there is implant failure with no clear signs of infection and in patients with delayed implant failure. In early failure, SFC is not superior to PITC for the diagnosis of infection and, therefore, is not recommended as a routine diagnostic test in these patients.

Cite this article: Bone Joint J 2013;95-B:244–9.


Bone & Joint 360
Vol. 3, Issue 6 | Pages 12 - 16
1 Dec 2014

The December 2014 Knee Roundup360 looks at: national guidance on arthroplasty thromboprophylaxis is effective; unicompartmental knee replacement has the edge in terms of short-term complications; stiff knees, timing and manipulation; neuropathic pain and total knee replacement; synovial fluid α-defensin and CRP: a new gold standard in joint infection diagnosis?; how to assess anterior knee pain?; where is the evidence? Five new implants under the spotlight; and a fresh look at ACL reconstruction


Bone & Joint Research
Vol. 3, Issue 8 | Pages 246 - 251
1 Aug 2014
Chang YH Tai CL Hsu HY Hsieh PH Lee MS Ueng SWN

Objectives

The objective of this study was to compare the elution characteristics, antimicrobial activity and mechanical properties of antibiotic-loaded bone cement (ALBC) loaded with powdered antibiotic, powdered antibiotic with inert filler (xylitol), or liquid antibiotic, particularly focusing on vancomycin and amphotericin B.

Methods

Cement specimens loaded with 2 g of vancomycin or amphotericin B powder (powder group), 2 g of antibiotic powder and 2 g of xylitol (xylitol group) or 12 ml of antibiotic solution containing 2 g of antibiotic (liquid group) were tested.


Bone & Joint 360
Vol. 3, Issue 2 | Pages 8 - 9
1 Apr 2014

The April 2014 Hip & Pelvis Roundup360 looks at: Recent arthroplasty and flight; whether that squeak could be a fracture; diagnosing early infected hip replacement; impaction grafting at a decade; whether squeaking is more common than previously thought; femoral offset associated with post THR outcomes; and periprosthetic fracture stabilisation.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 65 - 69
1 Jan 2014
Gutowski CJ Zmistowski BM Clyde CT Parvizi J

The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts.

The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.

Cite this article: Bone Joint J 2014;96-B:65–9.