Advertisement for orthosearch.org.uk
Results 401 - 420 of 709
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 248 - 260
1 May 1957
Smillie IS

1. The record is presented of an attempt to treat osteochondritis dissecans on idealistic lines. 2. The operative technique to be adopted in the various circumstances likely to be encountered in the knee joint is described. Two cases affecting the talus are recorded. 3. The radiological appearance has become virtually normal in twenty-seven cases (the remaining four are recent); healing has been observed directly in seven cases in which a second operation to remove the means of internal fixation was necessary; and the patients' complaints have been eliminated, but the long term results of treatment are unknown. 4. Suggestions are made for possible developments in the technique of operation


Bone & Joint Research
Vol. 8, Issue 2 | Pages 41 - 48
1 Feb 2019
Busse P Vater C Stiehler M Nowotny J Kasten P Bretschneider H Goodman SB Gelinsky M Zwingenberger S

Objectives

Intra-articular injections of local anaesthetics (LA), glucocorticoids (GC), or hyaluronic acid (HA) are used to treat osteoarthritis (OA). Contrast agents (CA) are needed to prove successful intra-articular injection or aspiration, or to visualize articular structures dynamically during fluoroscopy. Tranexamic acid (TA) is used to control haemostasis and prevent excessive intra-articular bleeding. Despite their common usage, little is known about the cytotoxicity of common drugs injected into joints. Thus, the aim of our study was to investigate the effects of LA, GC, HA, CA, and TA on the viability of primary human chondrocytes and tenocytes in vitro.

Methods

Human chondrocytes and tenocytes were cultured in a medium with three different drug dilutions (1:2; 1:10; 1:100). The following drugs were used to investigate cytotoxicity: lidocaine hydrochloride 1%; bupivacaine 0.5%; triamcinolone acetonide; dexamethasone 21-palmitate; TA; iodine contrast media; HA; and distilled water. Normal saline served as a control. After an incubation period of 24 hours, cell numbers and morphology were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 991 - 997
1 Sep 2004
Scheibel M Bartl C Magosch P Lichtenberg S Habermeyer P

We performed eight osteochondral autologous transplantations from the knee joint to the shoulder. All patients (six men, two women; mean age 43.1 years) were documented prospectively. In each patient the stage of the osteochondral lesion was Outerbridge grade IV with a mean size of the affected area of 150 mm. 2. All patients were assessed by using the Constant score for the shoulder and the Lysholm score for the knee. Standard radiographs, magnetic resonance imaging and second-look arthroscopy were used to assess the presence of glenohumeral osteoarthritis and the integrity of the grafts. After a mean of 32.6 months (8 to 47), the mean Constant score increased significantly. Magnetic resonance imaging revealed good osseointegration of the osteochondral plugs and congruent articular cartilage at the transplantation site in all but one patient. Second-look arthroscopy performed in two cases revealed a macroscopically good integration of the autograft with an intact articular surface. Osteochondral autologous transplantation in the shoulder appears to offer good clinical results for treating full-thickness osteochondral lesions of the glenohumeral joint. However, our study suggests that the development of osteoarthritis and the progression of pre-existing osteoarthritic changes cannot be altered by this technique


Bone & Joint Research
Vol. 8, Issue 2 | Pages 65 - 72
1 Feb 2019
Cowie RM Aiken SS Cooper JJ Jennings LM

Objectives

Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation.

Methods

A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 13 - 16
1 Feb 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 206 - 209
1 Apr 1982
Narang I Mysorekar V Mathur B

A 14-year-old girl with a congenitally deformed and shortened right leg and foot is described. The patient could not bear weight on the deformed limb and had to hop on the left leg. The deformed foot faced backwards and had nine toes. The right leg was shorter than the left by 26 centimetres. Radiologically, the lower end of the right femur was ill-developed and there was no knee joint. There were two fibulae and the tibia and the patella were absent. A through-knee disarticulation was done and a prosthesis fitted later. The amputated leg and foot were dissected. Many of the muscles in the leg and foot were duplicated. There were two calcanei, one talus, one navicular, two cuboids and four cuneiforms. Ther were nine metatarsals, and all the toes had three phalanges except for one which had two


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 315 - 318
1 Aug 1978
Cavendish M Wright J

This is a preliminary report of the results of knee joint replacements using the Liverpool Mark II knee joint system which consists of a bicondylar prosthesis and a set of stereotactic instruments. The prosthesis has been developed from Gunston's concept, and the special instruments ensure its accurate insertion through meniscectomy-type incisions placed on either side of the patella. Particular features of the prosthesis are near-normal articulation, and the simplicity of the operation. Sixty-two knee replacements were implanted in forty-two patients between the spring of 1974 and January 1977. After the operation fifty-six knees were painless and four others produced only slight pain. Full extension was obtained in fifty-eight knees, and none showed a valgus or varus deformity. Collateral laxity was absent in all knees. There were two failures. These early results are most encouraging


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 110 - 114
1 Feb 1974
Persson BM

1. A sagittal technique for below-knee amputation for ischaemic gangrene based on mediolateral musculo-cutaneous flaps is described, similar to the one independently presented by Tracy (1966). 2. The results with this method are illustrated by the evolution of the below-knee healing rate over six years in 172 patients with ischaemic gangrene. 3. A comparison between sagittal and conventional flap techniques shows a reamputation rate of six out of fifty-eight in the former and sixteen out of forty-one in the latter. 4. The overall relative knee joint preservation during 1971 was 82 per cent, and the frequency of attempted below-knee amputation was 93 per cent. 5. It is concluded that the sagittal technique has several advantages in comparison to the posterior flap technique, and that the potential for healing is on the same high level. 6. A fully controlled comparison between different techniques is proposed


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 576 - 582
1 Aug 1989
Doi K DeSantis G Singer D Hurley J O'Brien B McKay S Hickey M Murphy B

Five vascularised allografts of the knee joint were performed in dogs immunosuppressed with cyclosporin A and azathioprine. Three survived with normal function for 3 to 4 months after operation. One of the unsuccessful grafts had a failed vascular anastomosis, the other an inadequate blood level of cyclosporin A. All three successful grafts healed well. In two, bone scans, radiographs and biopsies were indistinguishable from successful autografts; in the third the blood supply to the graft failed despite patent anastomoses but the graft healed well with good function. All three grafts were rejected within 2 to 3 weeks of withdrawal of cyclosporin A and azathioprine. In non-immunosuppressed dogs, allografts of the knee, both vascularised and non-vascularised, were rejected within a few days of operation. In two non-vascularised allografts, administration of cyclosporin and azathioprine had no apparent effect on the rate of rejection of the graft


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 1 | Pages 59 - 62
1 Feb 1975
Phillips H Taylor JG

Eighty-three Waildius arthroplasties, performed by one surgeon as a salvage operation on the knee joint between 1966 and 1972, were independently reviewed. The fifty-seven living patients with sixty-seven arthroplasties were interviewed and examined and the clinical records of the deceased patients were inspected. Sixty-seven arthroplasties (81 per cent) were successful and sixteen failed (19 per cent). Acrylic cement was used to secure the prosthesis on eight occasions only. There were two primary infections (24 per cent) and two delayed (24 per cent). Major loosening occurred in three arthroplasties (36 per cent). Minor loosening was compatible with a good result. Arthrodesis was successful on the two occasions on which it became necessary to remove the implant. There were no disasters. On the basis of these results it is considered that the Walidius arthroplasty can justifiably be offered as an alternative to primary arthrodesis of the knee


Bone & Joint Research
Vol. 7, Issue 3 | Pages 252 - 262
1 Mar 2018
Nishida K Matsushita T Takayama K Tanaka T Miyaji N Ibaraki K Araki D Kanzaki N Matsumoto T Kuroda R

Objectives

This study aimed to examine the effects of SRT1720, a potent SIRT1 activator, on osteoarthritis (OA) progression using an experimental OA model.

Methods

Osteoarthritis was surgically induced by destabilization of the medial meniscus in eight-week-old C57BL/6 male mice. SRT1720 was administered intraperitoneally twice a week after surgery. Osteoarthritis progression was evaluated histologically using the Osteoarthritis Research Society International (OARSI) score at four, eight, 12 and 16 weeks. The expression of SIRT1, matrix metalloproteinase 13 (MMP-13), a disintegrin and metalloproteinase with thrombospondin motifs-5 (ADAMTS-5), cleaved caspase-3, PARP p85, and acetylated nuclear factor (NF)-κB p65 in cartilage was examined by immunohistochemistry. Synovitis was also evaluated histologically. Primary mouse epiphyseal chondrocytes were treated with SRT1720 in the presence or absence of interleukin 1 beta (IL-1β), and gene expression changes were examined by real-time polymerase chain reaction (PCR).


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 319 - 336
1 May 1959
Helfet AJ

1. The semilunar cartilages are part of the rotator mechanism of the knee joint. 2. Movement of the weight-bearing knee comprises synchronous lateral rotation of the tibia with extension and medial rotation of the tibia with flexion. 3. When this synchrony is disturbed, injuries to the semilunar cartilages result. 4. Damage to the anterior two-thirds of the medial cartilage blocks lateral rotation of the tibia, with consequent physical signs that are pathognomonic of the retracted and the bowstring cartilage, which are the most common types of injury. 5. Each type of cartilage injury produces its own pattern of erosion of articular cartilage and its own sequence of symptoms as so-called arthritis develops. 6. The sequence of symptoms may be halted and often reversed by removal of the torn cartilage. Operation is warranted in most cases however long the history and whatever the age of the patient. 7. The development of medial retropatellar arthritis is explained. The symptoms are often relieved by removal of the medial semilunar cartilage and adequate post-operative rehabilitation


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 388 - 400
1 May 1959
Jebens EH Monk-Jones ME

1. The results of viscosity measurements on a number of normal, traumatic and osteoarthritic synovial fluids from human knee joints are described and discussed. 2. A decrease of the viscosity of normal synovial fluid with age has been found. 3. The decrease of the viscosity with age and in the pathological groups is analysed and its relation to the viscous anomaly is considered (Fig. 6). 4. The question whether dilution or depolymerisation is the important factor in decrease of viscosity in these groups, and the value of viscosity measurements as a whole, are discussed. 5. Measurements of pH have been made on the same groups of synovial fluids and on the blood of patients in these groups. 6. The mean values for blood and synovial fluid differ significantly, and the pH of the synovial fluid of adolescents is significantly higher than at other ages. 7. There is no significant difference between the traumatic and osteoarthritic groups, but both are significantly less than the normal. 8. In both fluids the peak frequency in all three groups is the same, that for blood being 7·3 to 7·5 and that for synovial fluid being 7·5 to 7·7 (Fig. 7)


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 109 - 113
1 Jan 1997
Kuster MS Wood GA Stachowiak GW Gächter A

Estimates of knee joint loadings were calculated for 12 normal subjects from kinematic and kinetic measures obtained during both level and downhill walking. The maximum tibiofemoral compressive force reached an average load of 3.9 times body-weight (BW) for level walking and 8 times BW for downhill walking, in each instance during the early stance phase. Muscle forces contributed 80% of the maximum bone-on-bone force during downhill walking and 70% during level walking whereas the ground reaction forces contributed only 20% and 30% respectively. Most total knee designs provide a tibiofemoral contact area of 100 to 300 mm. 2. The yield point of these polyethylene inlays will therefore be exceeded with each step during downhill walking. Future evaluation of total knee designs should be based on a tibiofemoral joint load of 3.5 times BW at 20° knee flexion, 8 times BW at 40° and 6 times BW at 60°


Bone & Joint 360
Vol. 7, Issue 6 | Pages 39 - 40
1 Dec 2018


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1128 - 1133
1 Nov 2003
Fukui N Nakagawa T Murakami S Hiraoka H Nakamura K

Axial radiographs were obtained under valgus and external rotation stress at 45° of knee flexion with and without contraction of the quadriceps muscle in order to assess the dynamics of patellar subluxation or dislocation. The radiography was performed on 82 knees in 61 patients with patellofemoral instability, and on 44 normal knees. The lateral patellofemoral angle and the congruence angle were measured and compared with the conventional Merchant views. Both parameters showed greater differences between symptomatic and normal knees on the stress radiographs obtained without quadriceps contraction. There was a major difference in the lateral patellofemoral angles between the groups, which clearly distinguished symptomatic knees from normal controls. Congruence angles on stress radiography had a significant correlation with the functional scores obtained after a period of conservative treatment and a positive correlation with the frequency of patellar subluxation. When the quadriceps contracted, two patterns of patellar shift were observed. While the patella reduced into the trochlear groove in all normal knees and about 70% of the symptomatic knees, contraction of the quadriceps caused further subluxation of the patella in the remaining symptomatic knees. All the knee joints which showed this displacement failed to respond to conservative treatment and eventually required surgical treatment. Thus, this technique of stress radiography is a simple, cost-effective and useful method of evaluating patellar instability and predicting the prognosis


Bone & Joint Research
Vol. 8, Issue 4 | Pages 179 - 188
1 Apr 2019
Chen M Chang C Yang L Hsieh P Shih H Ueng SWN Chang Y

Objectives

Prosthetic joint infection (PJI) diagnosis is a major challenge in orthopaedics, and no reliable parameters have been established for accurate, preoperative predictions in the differential diagnosis of aseptic loosening or PJI. This study surveyed factors in synovial fluid (SF) for improving PJI diagnosis.

Methods

We enrolled 48 patients (including 39 PJI and nine aseptic loosening cases) who required knee/hip revision surgery between January 2016 and December 2017. The PJI diagnosis was established according to the Musculoskeletal Infection Society (MSIS) criteria. SF was used to survey factors by protein array and enzyme-linked immunosorbent assay to compare protein expression patterns in SF among three groups (aseptic loosening and first- and second-stage surgery). We compared routine clinical test data, such as C-reactive protein level and leucocyte number, with potential biomarker data to assess the diagnostic ability for PJI within the same patient groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 287 - 290
1 Aug 1976
Goodfellow J Hungerford D Zindel M

Cadaver knee joints were mounted so that life-like forces of weight-bearing were simulated. The patello-femoral contact areas were defined under load throughout the range of movement by the dye method. During movement from extension to 90 degrees of flexion a band of contact sweeps across the patella from inferior to superior pole, but the odd facet makes no contact. At about 135 degrees of flexion separate medial and lateral contact areas form, the medial one limited to the odd facet. From extension to 90 degrees of flexion the patella holds the quadriceps tendon away from the femur, but in further degrees of flexion an extensive "tendo-femoral" contact area forms. Between 90 degrees and 135 degrees of flexion the patella rotates and the ridge between the medial and odd facets engages the femoral condyle. The odd facet is shown to be a habitual non-contact area and the ridge to be subject to high load, observations which correlate with cartilage lesions described in Part 2 of the paper


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 710 - 716
1 Nov 1972
Myers DB Palmer DG

1. Joint compliance estimations were made on the knee joints of fourteen patients with rheumatoid arthritis, three patients with osteoarthritis and three healthy volunteers. 2. Diminishing values for capsular compliance were found in the normal volunteers, the patients under the age of thirty-five years with rheumatoid arthritis, the patients with osteoarthritis and the patients over the age of forty years with rheumatoid arthritis respectively. 3. In the young adult normal volunteers the average compliance was 8·1 cubic centimetres per millimetre of mercury at an intra-articular pressure of 5 millimetres of mercury and 0·7 cubic centimetre per millimetre of mercury at 50 millimetres of mercury. In the older patients with rheumatoid disease the average compliance was 2·1 cubic centimetres per millimetre of mercury at 5 millimetres of mercury and 0·4 cubic centimetre per millimetre of mercury at 50 millimetres of mercury. 4. Both the effects of ageing and the effects of disease appeared to be responsible for the low capsular compliance observed in patients over the age of forty years with rheumatoid arthritis, but duration of disease did not seem to be a contributing factor