Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
Delayed diagnosis is a well-known complication of a Monteggia
fracture-dislocation. If left untreated, the dislocated radial head
later becomes symptomatic. The purposes of this study were firstly,
to evaluate the clinical and radiological results of open reduction
of the radial head and secondly, to identify the factors that may
affect the outcome of this procedure. This retrospective study evaluated 30 children with a chronic
Monteggia lesion. There were 18 boys and 12 girls with a mean age
of 7.4 years (4 to 13) at the time of open reduction. The mean interval
to surgery, after the initial fracture, was 23.4 months (6 to 120).
Clinical grading used a Kim modified elbow score: radiological outcome
was recorded. The effect of the patient’s age, gender, duration
from initial injury, Bado classification, and annular ligament reconstruction
were analyzed. The mean follow-up was 42.2 months (15 to 20).Aims
Materials and Methods
Our aim was to describe the mid-term appearances of the repair
process of the Achilles tendon after tenotomy in children with a
clubfoot treated using the Ponseti method. A total of 15 children (ten boys, five girls) with idiopathic
clubfoot were evaluated at a mean of 6.8 years (5.4 to 8.1) after
complete percutaneous division of the Achilles tendon. The contour
and subjective thickness of the tendon were recorded, and superficial
defects and its strength were assessed clinically. The echogenicity,
texture, thickness, peritendinous irregularities and potential for
deformation of the tendon were evaluated by ultrasonography.Aims
Patients and Methods
Gastrocnemius tightness predisposes to musculoskeletal pathology
and may require surgical treatment. However, it is not clear what
proportion of patients with foot and ankle pathology have clinically
significant gastrocnemius tightness. The aim of this study was to
compare the prevalence and degree of gastrocnemius tightness in
a control group of patients with a group of patients with foot and
ankle pathology. This prospective, case-matched, observational study compared
gastrocnemius tightness, as assessed by the lunge test, in a control
group and a group with foot and ankle pathology. Gastrocnemius tightness
was calculated as the difference in dorsiflexion of the ankle with
the knee extended and flexed.Aims
Patients and Methods
We present a case series of five patients who had revision surgery
following magnetic controlled growing rods (MGCR) for early onset
scoliosis. Metallosis was found during revision in four out of five
patients and we postulated a mechanism for rod failure based on
retrieval analysis. Retrieval analysis was performed on the seven explanted rods.
The mean duration of MCGR from implantation to revision was 35 months
(17 to 46). The mean age at revision was 12 years (7 to 15; four
boys, one girl).Aims
Patients and Methods
The aim of this study was to present a series of patients with
aseptic failure of a total ankle arthroplasty (TAA) who were treated
with fusion of the hindfoot using a nail. A total of 23 TAAs, in 22 patients, were revised for aseptic
loosening and balloon osteolysis to a hindfoot fusion by a single
surgeon (NH) between January 2012 and August 2014. The procedure
was carried out without bone graft using the Phoenix, Biomet Hindfoot
Arthrodesis Nail. Preoperative investigations included full blood
count, CRP and ESR, and radiological investigations including plain
radiographs and CT scans. Postoperative plain radiographs were assessed
for fusion. When there was any doubt, CT scans were performed.Aims
Patients and Methods
The primary aim of this study was to determine the morbidity
of a tibial strut autograft and characterize the rate of bony union
following its use. We retrospectively assessed a series of 104 patients from a single
centre who were treated with a tibial strut autograft of > 5 cm
in length. A total of 30 had a segmental reconstruction with continuity
of bone, 27 had a segmental reconstruction without continuity of
bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity
was defined as any event that required a modification of the postoperative
management. Union was assessed clinically and radiologically at
a median of 36 months (IQR, 14 to 74).Aims
Patients and Methods
This study reviews the use of a titanium mesh cage (TMC) as an
adjunct to intramedullary nail or plate reconstruction of an extra-articular
segmental long bone defect. A total of 17 patients (aged 17 to 61 years) treated for a segmental
long bone defect by nail or plate fixation and an adjunctive TMC
were included. The bone defects treated were in the tibia (nine),
femur (six), radius (one), and humerus (one). The mean length of
the segmental bone defect was 8.4 cm (2.2 to 13); the mean length
of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and
radiological records of the patients were analyzed retrospectively.Aims
Patients and Methods
Stable fractures of the ankle can be safely treated
non-operatively. It is also gradually being recognised that the integrity
of the ‘medial column’ is essential for the stability of the fracture.
It is generally thought that bi- and tri-malleolar fractures are
unstable, as are pronation external rotation injuries resulting
in an isolated high fibular fracture (Weber type-C), where the deltoid
ligament is damaged or the medial malleolus fractured. However,
how best to identify unstable, isolated, trans-syndesmotic Weber
type-B supination external rotation (SER) fractures of the lateral
malleolus remains controversial. We provide a rationale as to how to classify SER distal fibular
fractures using weight-bearing radiographs, and how this can help
guide the management of these common injuries. Cite this article:
To compare the structural durability of hydroxyapatite-tricalcium
phosphate (HATCP) to autologous iliac crest bone graft in calcaneal
lengthening osteotomy (CLO) for pes planovalgus in childhood. We present the interim results of ten patients (HATCP, n = 6
and autograft, n = 5) with a mean age of 11.5 years (8.2 to 14.2)
from a randomised controlled non-inferiority trial with six months
follow-up. The primary outcome was the stability of the osteotomy
as measured by radiostereometric analysis. A non-inferiority margin
of ≤ 2 mm osteotomy compression was set.Aims
Patients and Methods
This prospective cohort study aims to determine if the size of
the tendon gap following acute rupture of the Achilles tendon shows
an association with the functional outcome following non-operative
treatment. All patients presenting within two weeks of an acute unilateral
rupture of the Achilles tendon between July 2012 and July 2015 were
considered for the study. In total, 38 patients (nine female, 29
male, mean age 52 years; 29 to 78) completed the study. Dynamic
ultrasound examination was performed to confirm the diagnosis and
measure the gap between ruptured tendon ends. Outcome was assessed
using dynamometric testing of plantarflexion and the Achilles tendon
Total Rupture score (ATRS) six months after the completion of a
rehabilitation programme.Aims
Patients and Methods
The aim of this study was to report the clinical, functional
and radiological outcomes of children and adolescents with tibial
fractures treated using the Ilizarov method. Between 2013 and 2016 a total of 74 children with 75 tibial fractures
underwent treatment at our major trauma centre using an Ilizarov
frame. Demographic and clinical information from a prospective database
was supplemented by routine functional and psychological assessment
and a retrospective review of the notes and radiographs.Aims
Patients and Methods
This review explores recent advances in fixator design and used in contemporary orthopaedic practice including the management of bone loss, complex deformity and severe isolated limb injury.
This study compared the long-term results following Salter osteotomy
and Pemberton acetabuloplasty in children with developmental dysplasia
of the hip (DDH). We assessed if there was a greater increase in
pelvic height following the Salter osteotomy, and if this had a
continued effect on pelvic tilt, lumbar curvature or functional outcomes. We reviewed 42 children at more than ten years post-operatively
following a unilateral Salter osteotomy or Pemberton acetabuloplasty.
We measured the increase in pelvic height and the iliac crest tilt
and sacral tilt at the most recent review and at an earlier review
point in the first decade of follow-up. We measured the lumbar Cobb angle
and the Short Form-36 (SF-36) and Harris hip scores were collected
at the most recent review.Aims
Patients and Methods
After intercalary resection of a bone tumour from the femur,
reconstruction with a vascularized fibular graft (VFG) and massive
allograft is considered a reliable method of treatment. However,
little is known about the long-term outcome of this procedure. The
aims of this study were to determine whether the morbidity of this
procedure was comparable to that of other reconstructive techniques,
if it was possible to achieve a satisfactory functional result, and
whether biological reconstruction with a VFG and massive allograft
could achieve a durable, long-lasting reconstruction. A total of 23 patients with a mean age of 16 years (five to 40)
who had undergone resection of an intercalary bone tumour of the
femur and reconstruction with a VFG and allograft were reviewed
clinically and radiologically. The mean follow-up was 141 months
(24 to 313). The mean length of the fibular graft was 18 cm (12 to
29). Full weight-bearing without a brace was allowed after a mean
of 13 months (seven to 26).Aims
Patients and Methods
In arthritis of the varus knee, a high tibial
osteotomy (HTO) redistributes load from the diseased medial compartment
to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women)
with 42 varus, arthritic knees who underwent HTO and dynamic correction
using a Garches external fixator until they felt that normal alignment
had been restored. The mean age of the patients was 54.11 years
(34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3
to 10) post-operatively. Radiographs, gait analysis and visual analogue
scores for pain were measured pre- and post-operatively, at one
year and at medium-term follow-up (mean six years; 2 to 10). Failure
was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal
groups with high (17 patients) or low (19 patients) adductor moments.
After correction, a statistically significant (p <
0.001, At final follow-up, after a mean of 15.9 years (12 to 20), there
was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of
adductor moment group, with a mean time to conversion to knee arthroplasty
of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment
of medial compartment osteoarthritis of the knee but does not last
in the long-term. Cite this article:
Single-event multilevel surgery (SEMLS) has been used as an effective
intervention in children with bilateral spastic cerebral palsy (BSCP)
for 30 years. To date there is no evidence for SEMLS in adults with
BSCP and the intervention remains focus of debate. This study analysed the short-term outcome (mean 1.7 years, standard
deviation 0.9) of 97 ambulatory adults with BSCP who performed three-dimensional
gait analysis before and after SEMLS at one institution. Aims
Methods
The aims of this study were to examine the rate at which the
positioning of the acetabular component, leg length discrepancy
and femoral offset are outside an acceptable range in total hip
arthroplasties (THAs) which either do or do not involve the use
of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients
before and 50 patients after the integration of an intra-operative
digital imaging system in THA. The demographics of the two groups
were comparable for body mass index, age, laterality and the indication
for surgery. The digital imaging group had more men than the group without.
Surgical data and radiographic parameters, including the inclination
and anteversion of the acetabular component, leg length discrepancy,
and the difference in femoral offset compared with the contralateral
hip were collected and compared, as well as the incidence of altering
the position of a component based on the intra-operative image.Aims
Patients and Methods